TL detectors
Dotaz
Zobrazit nápovědu
The aim of this paper is to investigate the possibility of using detectors based on LaBr3(Ce) scintillation crystal as part of gamma spectrometry systems for field use and possibly as part of a monitoring network around nuclear power plants, i.e. whether LaBr3(Ce) detectors can follow the classical scintillation detectors based on NaI (Tl). For this purpose, the Monte Carlo simulation of the IPROL-1 probe response was performed in the simplified geometry of the radionuclides-contaminated atmosphere. A study shows that a LaBr3(Ce)-based probe is usable for this purpose and results are at least comparable to those with a conventional NaI (Tl)-based probe.
- MeSH
- dávka záření MeSH
- havárie elektrárny Fukušima MeSH
- jaderné elektrárny * MeSH
- lidé MeSH
- metoda Monte Carlo MeSH
- monitorování radiace přístrojové vybavení metody MeSH
- počítačová simulace * MeSH
- radiační expozice analýza MeSH
- radioaktivní látky znečišťující vzduch analýza MeSH
- záření gama MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The paper describes a method of pulse height spectrum measurement in a wide energy range. The LVR‑15 research reactor building was chosen to demonstrate this method. Pulse height spectra were measured on the third floor of the reactor building. Two types of scintillation detectors, NaI (Tl) and a plastic scintillator, were used. The detectors were placed for about 25 m from the reactor core, thus, separated from the primary circuit water in the reactor pool, biological shielding, building wall and other constructional materials. Spectra were measured in a wide energy range from 30 keV to 1000 MeV, in which signals were recorded from natural and man-made radionuclides, prompt gamma radiation and cosmic radiation. Experimental data were collected both while the reactor was in operation and while it was out of operation. This study confirms that differences in these spectra can be detected remotely over relatively large distances from the reactor core by adequately simple detection means.
- MeSH
- dávka záření MeSH
- konstrukční materiály MeSH
- kosmické záření * MeSH
- lidé MeSH
- plastické hmoty MeSH
- scintilace - počítání přístrojové vybavení metody MeSH
- záření gama * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
A new triple-to-double coincidence ratio (TDCR) system has been established at CMI as an additional technique for primary activity standardisation. Details of the detectors and the electronics are given. Construction of the optical chamber was validated using measurement of a (3)H standard-the efficiency achieved with Ultima Gold was 58%. Several methods of efficiency variation (coloured bands painted on vial, positioning and photomultipliers defocussing) are compared. Activity concentrations of (204)Tl and (45)Ca were determined with the TDCR method and with the efficiency tracer technique. Advantages of the TDCR method compared to the efficiency tracing method and agreement between results are shown.
- MeSH
- analýza selhání vybavení MeSH
- dávka záření MeSH
- design vybavení MeSH
- internacionalita MeSH
- poločas MeSH
- radioizotopy thallia analýza normy MeSH
- radioizotopy vápníku analýza normy MeSH
- radiometrie přístrojové vybavení normy MeSH
- referenční hodnoty MeSH
- referenční standardy MeSH
- Publikační typ
- časopisecké články MeSH
Cíl: Cílem práce je shrnutí prvních zkušeností s vyšetřováním klinicky indikovaných vyšetření výpočetní tomografií pomocí jedno-zdrojového prototypu photon-counting detektor CT. Metodika: Vyšetření byla prováděna na jednozdrojovém přístroji s detektorovou soustavou na bázi photon-counting detektoru. Hodnocena byla vyšetření u 50 vyšetřených pacientů, 20 vyšetření plic, 15 vyšetření dvoufázového vyšetření břicha, deset vyšetření tepen hlavy a krku a pět vyšetření hlavy včetně kosti spánkové, vyšetření byla prováděna pomocí akvizice datových stop s šíří elementu 0,4 nebo 0,2 mm. Byla hodnocena spolehlivost akvizice a kvalita zobrazení anatomických struktur Výsledky: U neselektovaných nemocných indikovaných pro vyšetření výpočetní tomografií byla získána zobrazení, která jsou klinicky minimálně rovnocenným zobrazením ke konvenčnímu CT. Vzhledem k vynikajícímu rozlišení je možné získat zobrazení jemných struktur těla, jakými jsou distální větvení bronchů, kvalitní separace cév a skeletu v oblasti báze lební, zobrazení skloubení sluchových kůstek. U všech vyšetření plic s referenční hodnotou 10 mAs byla dosažena hodnota pod 1 mSv, podobně i u vyšetření CTA hlavy, CT mozku i kosti spánkové, u vyšetření břicha bylo dosaženo srovnatelných hodnot jako u obvyklých při vyšetření konvenčním detektorem. Závěr: Zobrazení photon-counting detektor CT jsou klinicky plně využitelná, radiační zátěž je u většiny vyšetření snížená ve srovnání s použitím konvenčního přístroje CT. Je možné spolehlivě zobrazit submilimetrové detaily anatomických struktur.
Aim: The aim of the study is to summarize the first experience with the imaging using prototype of single-source photon-counting-detector CT in clinically indicated examinations. Method: All examinations were performed using single-source CT equipped with photon-counting detector. The sample of examinations in 50 patients were evaluated. There were 20 lung parenchyma examinations in diffuse lung diseases (including 10 with ultrahigh resolution mode with slice resolution 0.2 mm), 15 examinations of the abdomen in arterial and portal venous phase (incl. 5 ultrahigh resolution mode with slice resolution of 0.2 mm), 10 examinations of cervical and intracranial arteries, five brain examinations including ultrahigh resolution of the temporal bone. The data acquisition was made using resolution of 0.4 mm for a standard mode and 0.2 mm for ultrahigh resolution. Results: In non-selected patients with the indication for a clinical imaging, there were obtained images fully useful for a clinical assessment. Those images were minimally at the same level as made with conventional CT, or better. Thanks to the excellent resolution, it could be possible to visualize the tiny anatomical structures like bronchi on sub-segmental level of higher generation, the high quality display of vascular structures and articulations of middle ear ossicles. The effective dose equivalent reaches value less than one mSv in all lung, cervical and intracranial arteries, brain and temporal bone, those examinations of the abdomen did not exceed the for conventional CT typical levels of mSv. Conclusion: The imaging using photon-counting-detector CT were acquired with full clinical usefulness, radiation doses burden to the scanned individual are lower than those in conventional CT in most of indication. The subtle, submillimeter details of the anatomical structures could be visualized with the high certainty.
The article discusses an autonomous and flexible robotic system for radiation monitoring. The detection part of the system comprises two NaI(Tl) scintillation detectors: one of these is collimated to allow directionally sensitive measurements and the other is used to calculate the dose rate and provides sufficient sensitivity. Special algorithms for autonomous operation of an unmanned ground vehicle were developed, utilizing radiation characteristics acquired by the implemented detection system. The system was designed to operate in three modes: radiation mapping, localization of discrete sources and inspection of a region of interest. All of the modes were verified experimentally. In the localization mode, the time required to localize ionizing radiation sources was reduced by half compared to the field mapping mode exploiting parallel trajectories; the localization accuracy remained the same. In the inspection mode, the desired functionality was achieved, and the changes in the sources arrangement were detected reliably in the experiments.
- MeSH
- algoritmy * MeSH
- ionizující záření * MeSH
- lidé MeSH
- monitorování radiace přístrojové vybavení MeSH
- robotika metody MeSH
- scintilace - počítání přístrojové vybavení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The procedure accounts for uncertainties in the measurement and in the mass energy transfer coefficients needed for the calculation. The WinBUGS program (Spiegelhalter et al., 1999) was used. The results show that the relative uncertainties in the Air Kerma estimate are of about 1%, and that the choice of unfolding procedure may lead to an estimate systematic error of 3%.
The radon concentration in underground workplaces may reach tens of thousands of Bq m(-3). A simple MCNPXTM Monte Carlo (MC) model of a cave was developed to estimate the influence of radon on the in situ gamma spectrometry results in various geometries and radon concentrations. The detector total count rate was obtained as the sum of the individual count rates due to 214Bi in the air, radon in the walls and deposition of radon daughters on surfaces. The MC model was then modified and used in the natural conditions of the Mladeč Caves, Czech Republic. The content of 226Ra was calculated from laboratory gamma spectrometry measurements, and the concentrations of unattached and attached 214Bi were measured using the FRITRA4 device (SMM-Prague). We present a comparison of the experimental results with results calculated by the MCNPXTM model of the Gamma Surveyor spectrometry probe (GF Instruments) with a 3″×3″ NaI(Tl) detector and a 2″×2″ BGO detector.
- MeSH
- dceřiné produkty radonu MeSH
- jeskyně chemie MeSH
- lidé MeSH
- metoda Monte Carlo * MeSH
- monitorování radiace * MeSH
- radioaktivní znečišťující látky analýza MeSH
- radon analýza MeSH
- spektrometrie gama přístrojové vybavení metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
This paper reports on the structure of the autonomous station for monitoring artificial gamma activity in surface water bodies for the purposes of emergency preparedness of the Czech Republic. A simple design based on the NaI(Tl) submersible detector powered by a combined solar and wind source has been employed. Data transfer is provided by a satellite connection. The detection capabilities of the device have been tested for various unfavourable conditions, and the detection limits have been lowered by using the noise adjustment singular value decomposition (NASVD) method. The detection capabilities of the device fulfil the legal requirements for emergency monitoring, and are almost equal to the detection capabilities of other available devices with a more complicated and less versatile structure.
- MeSH
- monitorování radiace přístrojové vybavení MeSH
- radioaktivní látky znečišťující vodu analýza MeSH
- radioizotopy cesia analýza MeSH
- radioizotopy jodu analýza MeSH
- spektrometrie gama přístrojové vybavení MeSH
- záření gama MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
Vyšetření pomocí výpočetní tomografie (CT) je založeno na měření absorpce svazku rentgenového záření v tenké vrstvě vyšetřované oblasti těla. CT přístroj tvoří systém rotující rentgenky a sektoru detektorů na obvodu vyšetřovacího kruhu CT přístroje (gantry). Matematickým výpočtem je určena výše absorpce rentgenového záření, zobrazená v odstínech šedi. K určení rozsahu denzity (míry absorpce a rozptylu záření) v dané oblasti se používají Hounsfieldovy jednotky (HU). V článku jsou rozebrány typy CT vyšetření, jeho indikace v jednotlivých částech těla, příprava nemocného před vyšetřením, možnosti použití kontrastní látky.
Computerized tomography examination (CT) is based on the measurement of absorption of X-ray beam in a thin layer of the investigated area of the body. CT machine consists of a system of rotating X-ray tube and sector of detectors localized on the ring of examination circle of CT device (gantry). Mathematical calculation determines the amount of X-ray absorption shown in shades of gray. To determine the density range (extent of absorption of radiation and scattering radiation) in the area Hounsfield´s units (HU) are used. The article discusses types of CT examinations, its indications in different parts of the body, preparation of the patient before the examination, the possibility of using contrast media.
To help operators acknowledge patient dose during interventional procedures, EURADOS WG-12 focused on measuring patient skin dose using XR-RV3 gafchromic films, thermoluminescent detector (TLD) pellets or 2D TL foils and on investigating possible correlation to the on-line dose indicators such as fluoroscopy time, Kerma-area product (KAP) and cumulative air Kerma at reference point (CK). The study aims at defining non-centre-specific European alert thresholds for skin dose in three interventional procedures: chemoembolization of the liver (CE), neuroembolization (NE) and percutaneous coronary interventions (PCI). Skin dose values of >3 Gy (ICRP threshold for skin injuries) were indeed measured in these procedures confirming the need for dose indicators that correlate with maximum skin dose (MSD). However, although MSD showed fairly good correlation with KAP and CK, several limitations were identified challenging the set-up of non-centre-specific European alert thresholds. This paper presents preliminary results of this wide European measurement campaign and focuses on the main challenges in the definition of European alert thresholds.
- MeSH
- absorpce radiace MeSH
- fyziologie kůže účinky záření MeSH
- intervenční radiografie metody MeSH
- kardiovaskulární chirurgické výkony metody MeSH
- kůže radiografie MeSH
- lidé MeSH
- maximální přípustná koncentrace MeSH
- radiometrie přístrojové vybavení metody MeSH
- rentgenové záření * MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- srovnávací studie MeSH