multielectrode array
Dotaz
Zobrazit nápovědu
We present a custom-made multielectrode array for the recording of evoked potentials during acute experiments in rats, which offers a quick and reliable estimation of the cortical tonotopy. The array consists of electrodes represented by insulated copper wires of 0.09 mm diameter fixed in epoxy resin in a 3 x 5 arrangement, with final impedances of 410-800 kOhm. The array was placed on the brain surface of anesthetized rats approximately at the location of the auditory cortex (AC) and the cortical evoked potentials (middle-latency responses, MLR) were elicited by a series of tone pips of different frequencies at 50 dB of sound pressure level (SPL) intensity. The frequency that evoked the highest MLR amplitude (best frequency, BF) was identified for each electrode. The obtained distribution of the BFs characterized the cortical tonotopy, and it correlated with the frequency selectivity of neurons recorded at the same positions by an extracellular microelectrode. Although the space resolution of the array did not allow for the identification of AC sub regions, the array proved to be a reliable tool for a quick estimation and prediction of areas of interest for the subsequent measurements of neurons by more precise techniques.
- MeSH
- akustická stimulace metody MeSH
- časové faktory MeSH
- implantované elektrody * MeSH
- krysa rodu rattus MeSH
- mapování mozku přístrojové vybavení metody MeSH
- potkani Long-Evans MeSH
- sluchové evokované potenciály fyziologie MeSH
- sluchové korové centrum fyziologie MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- fibrilace síní * chirurgie patofyziologie MeSH
- katetrizační ablace * metody přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- převodní systém srdeční patofyziologie MeSH
- recidiva MeSH
- senioři MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Preclinical studies have revealed that pulsed field ablation (PFA) lesion dimensions increase with repetitive applications at a similar electric field. OBJECTIVES: This study investigated whether pulmonary vein isolation (PVI) durability varies with single vs repetitive pulsed field (PF) applications. METHODS: Atrial fibrillation patients underwent PVI using a spherical multielectrode array PFA catheter delivered with a 19-F deflectable sheath under intracardiac echocardiographic guidance. Esophagogastroduodenoscopy and brain magnetic resonance imaging were performed within 1 to 3 days, and invasive remapping at ∼2 to 3 months. RESULTS: The patient cohort (n = 21; age 63 ± 11 years; 67% women) underwent PVI in either of 2 groups: group 1 (n = 11)-single PF application/PV; and group 2 (n = 10)-3 PF applications/PV. In both groups, PVI was acutely successful in all (100%) patients. Despite significantly longer pulse delivery times (75.2 ± 7.4 s/patient vs 24.5 ± 5.5 s/patient) the procedure times (73.2 ± 13.7 minutes vs 93.7 ± 18.5 minutes) were shorter with group 2 vs group 1. There was no stroke/transient ischemic attack, pericardial effusion, phrenic nerve injury, or esophageal complications. Esophagogastroduodenoscopy was normal in both groups of patients (n = 9). Screening brain magnetic resonance imaging revealed asymptomatic cerebral lesions (diffusion weighted imaging+/fluid attenuated inversion recovery-) in 3 of 16 (18.7%) patients. PV remapping revealed durable PVI in 62.5% PVs in group 1 (n = 10), compared with all 100% PVs in group 2 (n = 9); this translates to all PVs being durably isolated in 30% vs 100% (P < 0.05) of patients in groups 1 and 2, respectively. CONCLUSIONS: In his first-in-human trial, the "single-shot" spherical array PFA catheter was shown to safely isolate PVs. Repetitive PF application is key for lesion consolidation to maximize PVI durability.
- MeSH
- časové faktory MeSH
- katetrizační ablace * metody MeSH
- katétry MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- srdeční frekvence MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
In this study the MEA (multielectrode array) system was used to record electrical responses of intact and halved traps, and other trap-free tissues of two aquatic carnivorous plants, Aldrovanda vesiculosa and Utricularia reflexa. They exhibit rapid trap movements and their traps contain numerous glands. Spontaneous generation of spikes with quite uniform shape, propagating across the recording area, has been observed for all types of sample. In the analysis of the electrical network, higher richer synchronous activity was observed relative to other plant species and organs previously described in the literature: indeed, the time intervals between the synchronized clusters (the inter-spike intervals) create organized patterns and the propagation times vary non-linearly with the distance due to this synchronization. Interestingly, more complex electrical activity was found in traps than in trap-free organs, supporting the hypothesis that the nature of the electrical activity may reflect the anatomical and functional complexity of different organs. Finally, the electrical activity of functionally different traps of Aldrovanda (snapping traps) and Utricularia (suction traps) was compared and some differences in the features of signal propagation were found. According to these results, a possible use of the MEA system for the study of different trap closure mechanisms is proposed.
- MeSH
- akční potenciály * MeSH
- Droseraceae fyziologie MeSH
- hluchavkotvaré fyziologie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The recently introduced orientation selective deep brain stimulation (OS-DBS) technique freely controls the direction of the electric field's spatial gradient by using multiple contacts with independent current sources within a multielectrode array. The goal of OS-DBS is to align the electrical field along the axonal track of interest passing through the stimulation site. Here we utilized OS-DBS with a planar 3-channel electrode for stimulating the rat entorhinal cortex (EC) and medial septal nucleus (MSN), two promising areas for DBS treatment of Alzheimer's disease. The brain responses to OS-DBS were monitored by whole brain functional magnetic resonance imaging (fMRI) at 9.4 T with Multi-Band Sweep Imaging with Fourier Transformation (MB-SWIFT). Varying the in-plane OS-DBS stimulation angle in the EC resulted in activity modulation of multiple downstream brain areas involved in memory and cognition. Contrary to that, no angle dependence of brain activations was observed when stimulating the MSN, consistent with predictions based on the electrode configuration and on the main axonal directions of the targets derived from diffusion MRI tractography and histology. We conclude that tuning the OS-DBS stimulation angle modulates the activation of brain areas relevant to Alzheimer's disease, thus holding great promise in the DBS treatment of the disease.
- MeSH
- Alzheimerova nemoc * diagnostické zobrazování terapie MeSH
- cortex entorhinalis diagnostické zobrazování fyziologie MeSH
- hluboká mozková stimulace * metody MeSH
- kognice MeSH
- krysa rodu rattus MeSH
- magnetická rezonanční tomografie metody MeSH
- mozek MeSH
- septální jádra * MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
RASopathies are a group of genetic disorders caused by mutations in genes encoding components and regulators of the RAS/MAPK signaling pathway, resulting in overactivation of signaling. RASopathy patients exhibit distinctive facial features, cardiopathies, growth and skeletal abnormalities, and varying degrees of neurocognitive impairments including neurodevelopmental delay, intellectual disabilities, or attention deficits. At present, it is unclear how RASopathy mutations cause neurocognitive impairment and what their neuron-specific cellular and network phenotypes are. Here, we investigated the effect of RASopathy mutations on the establishment and functional maturation of neuronal networks. We isolated cortical neurons from RASopathy mouse models, cultured them on multielectrode arrays and performed longitudinal recordings of spontaneous activity in developing networks as well as recordings of evoked responses in mature neurons. To facilitate the analysis of large and complex data sets resulting from long-term multielectrode recordings, we developed MATLAB-based tools for data processing, analysis, and statistical evaluation. Longitudinal analysis of spontaneous network activity revealed a convergent developmental phenotype in neurons carrying the gain-of-function Noonan syndrome-related mutations Ptpn11D61Y and KrasV14l. The phenotype was more pronounced at the earlier time points and faded out over time, suggesting the emergence of compensatory mechanisms during network maturation. Nevertheless, persistent differences in excitatory/inhibitory balance and network excitability were observed in mature networks. This study improves the understanding of the complex relationship between genetic mutations and clinical manifestations in RASopathies by adding insights into functional network processes as an additional piece of the puzzle.
- Publikační typ
- časopisecké články MeSH
Electrical stimulation of peripheral nerves is a cornerstone of bioelectronic medicine. Effective ways to accomplish peripheral nerve stimulation (PNS) noninvasively without surgically implanted devices are enabling for fundamental research and clinical translation. Here, it is demonstrated how relatively high-frequency sine-wave carriers (3 kHz) emitted by two pairs of cutaneous electrodes can temporally interfere at deep peripheral nerve targets. The effective stimulation frequency is equal to the offset frequency (0.5 - 4 Hz) between the two carriers. This principle of temporal interference nerve stimulation (TINS) in vivo using the murine sciatic nerve model is validated. Effective actuation is delivered at significantly lower current amplitudes than standard transcutaneous electrical stimulation. Further, how flexible and conformable on-skin multielectrode arrays can facilitate precise alignment of TINS onto a nerve is demonstrated. This method is simple, relying on the repurposing of existing clinically-approved hardware. TINS opens the possibility of precise noninvasive stimulation with depth and efficiency previously impossible with transcutaneous techniques.
- MeSH
- elektrická stimulace MeSH
- myši MeSH
- nervus ischiadicus fyziologie MeSH
- transkutánní elektrická neurostimulace * metody MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Cardiac side effects of some pulmonary drugs are observed in clinical practice. Aminophylline, a methylxanthine bronchodilator with documented proarrhythmic action, may serve as an example. Data on the action of aminophylline on cardiac cell electrophysiology and contractility are not available. Hence, this study was focused on the analysis of changes in the beat rate and contraction force of human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) and HL-1 cardiomyocytes in the presence of increasing concentrations of aminophylline (10 μM-10 mM in hPSC-CM and 8-512 μM in HL-1 cardiomyocytes). Basic biomedical parameters, namely, the beat rate (BR) and contraction force, were assessed in hPSC-CMs using an atomic force microscope (AFM). The beat rate changes under aminophylline were also examined on the HL-1 cardiac muscle cell line via a multielectrode array (MEA). Additionally, calcium imaging was used to evaluate the effect of aminophylline on intracellular Ca2+ dynamics in HL-1 cardiomyocytes. The BR was significantly increased after the application of aminophylline both in hPSC-CMs (with 10 mM aminophylline) and in HL-1 cardiomyocytes (with 256 and 512 μM aminophylline) in comparison with controls. A significant increase in the contraction force was also observed in hPSC-CMs with 10 μM aminophylline (a similar trend was visible at higher concentrations as well). We demonstrated that all aminophylline concentrations significantly increased the frequency of rhythm irregularities (extreme interbeat intervals) both in hPSC-CMs and HL-1 cells. The occurrence of the calcium sparks in HL-1 cardiomyocytes was significantly increased with the presence of 512 μM aminophylline. We conclude that the observed aberrant cardiomyocyte response to aminophylline suggests an arrhythmogenic potential of the drug. The acquired data represent a missing link between the arrhythmic events related to the aminophylline/theophylline treatment in clinical practice and describe cellular mechanisms of methylxanthine arrhythmogenesis. An AFM combined with hPSC-CMs may serve as a robust platform for direct drug effect screening.
- Publikační typ
- časopisecké články MeSH