pulsed-field ablation
Dotaz
Zobrazit nápovědu
INTRODUCTION: Atrial fibrillation (AF) can cause or aggravate heart failure (HF). Catheter ablation (CA) is an effective treatment for AF. This study focused on the feasibility and outcomes of emergent AF ablation performed during hospitalization for acute HF. METHODS AND RESULTS: We retrospectively investigated patients who underwent emergent CA for AF during hospitalization for acute HF in 2018-2024. Arrhythmia recurrence was the primary endpoint. The combination of arrhythmia recurrence, HF hospitalization, and all-cause death was the secondary endpoint. Patients were censored 1 year after the index procedure. We included 46 patients, 35% females, with median age of 67 [interquartile rage: 61, 72] years and left ventricular ejection fraction (LVEF) of 25 [23, 28]%. Thermal CA was performed in 14 patients, and pulsed field ablation (PFA) in 32 patients. Procedure time was significantly shorter with PFA compared to thermal CA (77 [57, 91] vs. 166 [142, 200] minutes, p < 0.001). Fluoroscopy time was longer with PFA (9.5 [7.6, 12.0] vs. 3.9 [2.9, 6.0] minutes, p < 0.001), with a borderline trend towards higher radiation dose (75 [53, 170] vs. 50 [30, 94] μGy.m2, p = 0.056). Extrapulmonary ablation was frequent (86% and 84% for thermal CA and PFA, p > 0.9). The estimated freedom from the primary endpoint was 79% after PFA and 64% after thermal CA (p = 0.44). The estimated freedom from the secondary endpoint was 76% after PFA and 57% after thermal CA (p = 0.43). LVEF improved by 24% ± 2% (p < 0.001) in patients with the first manifestation of HF and by 14% ± 4% (p = .004) in patients with decompensated HF diagnosed earlier. CONCLUSIONS: Emergent CA of AF during acute HF hospitalization is safe and associated with improved LVEF and good clinical outcomes. In the PFA era, the rate of these procedures is progressively increasing as they are readily available and easy to perform compared to thermal ablation.
- MeSH
- akční potenciály MeSH
- akutní nemoc MeSH
- časové faktory MeSH
- fibrilace síní * patofyziologie chirurgie diagnóza MeSH
- funkce levé komory srdeční * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva * MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční frekvence MeSH
- srdeční selhání * patofyziologie diagnóza terapie mortalita MeSH
- studie proveditelnosti * MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: Pulsed field ablation (PFA) of atrial fibrillation is a new method in clinical practice. Despite a favorable safety profile of PFA in atrial fibrillation ablation, rare cases of renal failure, probably due to hemolysis, have recently been reported. OBJECTIVE: The aim of this study was to determine the rate of hemolysis and cardiac cell death during in vitro PFA with different electric field intensities. METHODS: Blood samples from healthy volunteers and mouse HL-1 cardiomyocyte cell lines were subjected to in vitro irreversible electroporation using 216 bipolar pulses, each lasting 2 μs with intervals of 5 μs, repeated 20 times at a frequency of 1 Hz. These pulses varied from 500 V to 1500 V. Cell-free hemoglobin levels were assessed spectrophotometrically, and red blood cell microparticles were evaluated by flow cytometry. Cardiomyocyte death was quantified with propidium iodide. RESULTS: Pulsed field energy (1000 V/cm, 1250 V/cm, and 1500 V/cm) was associated with a significant increase in cell-free hemoglobin (0.32 ± 0.16 g/L, 2.2 ± 0.96 g/L, and 5.7 ± 0.39 g/L; P < .01) and similar increase in the concentration of red blood cell microparticles. Significant rates of cardiomyocyte death were observed at electric field strengths of 750 V/cm, 1000 V/cm, 1250 V/cm, and 1500 V/cm (26.5% ± 5.9%, 44.3% ± 6.2%, 55.5% ± 6.9%, and 74.5% ± 17.8% of cardiomyocytes; P < .01). CONCLUSION: The most effective induction of cell death in vitro was observed at 1500 V/cm. This intensity was also associated with a significant degree of hemolysis.
- MeSH
- elektroporace * metody MeSH
- fibrilace síní patofyziologie chirurgie MeSH
- hemolýza * fyziologie MeSH
- kardiomyocyty * metabolismus MeSH
- kultivované buňky MeSH
- lidé MeSH
- myši MeSH
- průtoková cytometrie MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Pulsed-field ablation (PFA) represents a new, nonthermal ablation energy for the ablation of atrial fibrillation (AF). Ablation energies producing thermal injury are associated with an inflammatory response, platelet activation, and coagulation activation. OBJECTIVES: This study aimed to compare the systemic response in patients undergoing pulmonary vein isolation (PVI) using pulsed-field and radiofrequency (RF) energy. METHODS: Patients with AF indicated for PVI were enrolled and randomly assigned to undergo PVI using RF (CARTO Smart Touch, Biosense Webster) or pulsed-field (Farapulse, Boston-Scientific) energy. Markers of myocardial damage (troponin I), inflammation (interleukin-6), coagulation (D-dimers, fibrin monomers, von Willebrand antigen and factor activity), and platelet activation (P-selectin, activated GpIIb/IIIa antigen) were measured before the procedure (T1), after trans-septal puncture (T2), after completing the ablation in the left atrium (T3), and 1 day after the procedure (T4). RESULTS: A total of 65 patients were enrolled in the pulsed-field ablation (n = 33) and RF ablation (n = 32) groups. Both groups were similar in baseline characteristics (age 60.5 ± 12.7 years vs 64.0 ± 10.7 years; paroxysmal AF: 60.6% vs 62.5% patients). Procedural and left atrial dwelling times were substantially shorter in the PFA group (55:09 ± 11:57 min vs 151:19 ± 41:25 min; P < 0.001; 36:00 ± 8:05 min vs 115:58 ± 36:49 min; P < 0.001). Peak troponin release was substantially higher in the PFA group (10,102 ng/L [IQR: 8,272-14,207 ng/L] vs 1,006 ng/L [IQR: 603-1,433ng/L]). Both procedures were associated with similar extents (>50%) of platelet and coagulation activation. The proinflammatory response 24 h after the procedure was slightly but nonsignificantly higher in the RF group. CONCLUSIONS: Despite 10 times more myocardial damage, pulsed-field ablation was associated with a similar degree of platelet/coagulation activation, and slightly lower inflammatory response. (The Effect of Pulsed-Field and Radiofrequency Ablation on Platelet, Coagulation and Inflammation; NCT05603637).
AIMS: Catheter ablation is an effective treatment method for recurrent ventricular tachycardias (VTs). However, at least in part, procedural and clinical outcomes are limited by challenges in generating an adequate lesion size in the ventricular myocardium. We investigated procedural and clinical outcomes of VT ablation using a novel 'large-footprint' catheter that allows the creation of larger lesions either by radiofrequency (RF) or by pulsed field (PF) energy. METHODS AND RESULTS: In prospectively collected case series, we describe our initial experience with VT ablation using a lattice-tip, dual-energy catheter (Sphere-9, Medtronic), and a compatible proprietary electroanatomical mapping system (Affera, Medtronic). The study population consisted of 18 patients (aged 55 ± 15 years, one woman, structural heart disease: 94%, ischaemic heart disease: 56%, left ventricular ejection fraction: 34 ± 10%, electrical storm: 22%) with recurrent sustained VTs and ≥1 previously failed endocardial RF ablation with conventional irrigated-tip catheter in 66% of patients. On average, 12 ± 7 RF and 8 ± 9 PF applications were delivered per patient. In three-fourths of patients undergoing percutaneous epicardial ablation, spasms in coronary angiography were observed after PF applications. All resolved after intracoronary administration of nitrates. No acute phrenic nerve palsy was noted. One patient suffered from a stroke that resolved without sequelae. Post-ablation non-inducibility of VT was achieved in 89% of patients. Ventricular-arrhythmia-free survival at three months was 78%. CONCLUSION: VT ablation using a dual-energy lattice-tip catheter and a novel electroanatomical mapping system is feasible. It allows rapid mapping and effective substrate modification with good outcomes during short-term follow-up.
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- design vybavení MeSH
- doba přežití bez progrese choroby MeSH
- dospělí MeSH
- elektrofyziologické techniky kardiologické * MeSH
- katetrizační ablace * metody přístrojové vybavení škodlivé účinky MeSH
- komorová tachykardie * chirurgie patofyziologie diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- srdeční katétry * MeSH
- studie proveditelnosti * MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Pulsed electric field (PEF) has emerged as a promising energy source for catheter ablation of atrial fibrillation (AF). However, data regarding the in-vivo effect of PEF energy on erythrocytes during AF ablation procedures are scarce. This study aimed to quantify the impact of PEF energy on erythrocyte damage during AF ablation by assessing specific hemolytic biomarkers. METHODS: A total of 60 patients (age: 68 years, males: 72%, serum creatinine: 91 μmol/L) with AF underwent catheter ablation of AF using PEF energy delivered by a multipolar pentaspline Farawave catheter (Farapulse, Boston Scientific, Inc.). Ablation beyond pulmonary vein isolation was performed at the operator's discretion. Peripheral venous blood was sampled for assessing the plasma levels of free hemoglobin (fHb), direct (conjugated) bilirubin, lactate dehydrogenase (LDH), and creatinine before, immediately after the ablation, and on the next day. RESULTS: Following the PEF ablation with duration of [median (interquartile range)] 75 (58, 95) min, with 74 (52, 92) applications and PVI only in 27% of patients, fHb, LDH, and direct bilirubin significantly increased, from 40 (18, 65) to 493 (327, 848) mg/L, from 3.1 (2.6, 3.6) to 6.8 (5.0, 7.9) μkat/L, and from 12 (9, 17) to 28 (16, 44) μmol/L, respectively (all p < .0001). A strong linear correlation was found between the peak fHb and the number of PEF applications (R = 0.81, p < .001). The major hemolysis (defined as fHb >500 mg/L) was predicted by the number of PEF applications with the corresponding area under the receiver operating characteristic curve of 0.934. The optimum cut-off value of >74 PEF applications predicted the major hemolysis with 89% sensitivity and 87% specificity. CONCLUSION: Catheter ablation of AF using PEF energy delivered from a pentaspline catheter is associated with significant intravascular hemolysis. More than 74 PEF applications frequently resulted in major hemolysis. However, the critical amount of PEF energy that may cause kidney injury in susceptible patients remains to be investigated.
- MeSH
- bilirubin krev MeSH
- biologické markery * krev MeSH
- časové faktory MeSH
- design vybavení MeSH
- erytrocyty MeSH
- fibrilace síní * chirurgie diagnóza patofyziologie krev MeSH
- hemoglobiny metabolismus MeSH
- hemolýza * MeSH
- katetrizační ablace * škodlivé účinky přístrojové vybavení MeSH
- kreatinin krev MeSH
- L-laktátdehydrogenasa krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční katétry MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Management of hypertrophic obstructive cardiomyopathy (HOCM) is often challenging, depending on clinical manifestation. This case report illustrates the complex treatment of HOCM with associated recurrent ventricular arrhythmias. CASE SUMMARY: A 54-year-old female with HOCM diagnosed in 2012 underwent a failed attempt for alcohol septal ablation, implantation of an implantable cardioverter-defibrillator, and repeated radiofrequency ablations (including ablation of the septal bulge to reduce LV obstruction). For ventricular tachycardia (VT) recurrences, she had stereotactic arrhythmia radioablation with subsequent epicardial cryoablation from mini-thoracotomy, and endocardial ablation with pulsed field energy. The situation was finally solved by mechanical support and heart transplantation. DISCUSSION: A few important lessons can be learned from the case. First, radiofrequency ablation was used successfully to decrease left outflow tract obstruction. Second, stereotactic radiotherapy has been used after four previous endo/epicardial catheter ablations to decrease the recurrences of VT. Third, mini-thoracotomy was used after previous epicardial ablation with subsequent adhesions to modify the epicardial substrate with cryoenergy. Fourth, pulsed field ablation of atrial fibrillation resulted in an excellent therapeutic effect. Fifth, pulsed field ablation was also used to modify the substrate for VT, and was complicated by transient AV block with haemodynamic deterioration requiring mechanical support. Finally, a heart transplant was the ultimate solution in the management of recurrent VT.
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
- MeSH
- fibrilace síní * chirurgie terapie MeSH
- kardiochirurgické výkony metody škodlivé účinky MeSH
- katetrizační ablace * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- perikard chirurgie MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.
- MeSH
- fibrilace síní * chirurgie terapie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- pooperační komplikace epidemiologie etiologie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.
- MeSH
- elektrofyziologické techniky kardiologické MeSH
- jizva etiologie MeSH
- katetrizační ablace * metody škodlivé účinky MeSH
- komorová tachykardie * chirurgie patofyziologie MeSH
- komorové extrasystoly * chirurgie patofyziologie diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- fibrilace síní * chirurgie patofyziologie MeSH
- katetrizační ablace * metody přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- převodní systém srdeční patofyziologie MeSH
- recidiva MeSH
- senioři MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH