Intoxikace vodou, která vede k hyponatremii, případně až hemolýze, je relativně vzácný, ale potenciálně smrtelný stav, jenž bývá nejčastěji pozorován u psů, kteří si rádi hrají ve vodě, je ale zaznamenána také např. u telat nebo lidí. Příznaky intoxikace vodou jsou nespecifické a nastupují poměrně rychle. Pokud nedojde k rychlému zásahu, jedinec upadá v důsledku edému mozku do kómatu a umírá.
Water intoxication that leads to hyponatraemia or even hemolysis is a relatively rare but potentially fatal condition that is most commonly observed in dogs who like to play in water, but is also described, for example, in calves or humans. The symptoms of water intoxication are non-specific and occur quite quickly. If there is no rapid intervention, the individual falls into a coma due to brain edema and dies.
- MeSH
- biologické markery analýza MeSH
- chybná diagnóza veterinární MeSH
- furosemid aplikace a dávkování MeSH
- hyponatremie etiologie veterinární MeSH
- insekticidy otrava MeSH
- intoxikace vodou * diagnóza etiologie farmakoterapie patofyziologie veterinární MeSH
- psi * MeSH
- výsledek terapie MeSH
- zvířata MeSH
- Check Tag
- mužské pohlaví MeSH
- psi * MeSH
- zvířata MeSH
- Publikační typ
- kazuistiky MeSH
- MeSH
- čelisti * inervace patofyziologie MeSH
- kočky MeSH
- nemoci zubů * diagnóza komplikace terapie MeSH
- odontogenní cysty diagnóza farmakoterapie chirurgie MeSH
- psi MeSH
- zvířata MeSH
- Check Tag
- kočky MeSH
- psi MeSH
- zvířata MeSH
- Publikační typ
- kazuistiky MeSH
- Klíčová slova
- Glucantime,
- MeSH
- ELISA MeSH
- játra patologie MeSH
- ledviny patologie MeSH
- Leishmania MeSH
- leishmanióza viscerální * diagnóza farmakoterapie patologie veterinární MeSH
- meglumin terapeutické užití MeSH
- nemoci psů * MeSH
- organokovové sloučeniny terapeutické užití MeSH
- protilátky protozoální krev MeSH
- psi MeSH
- slezina patologie MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- zvířata MeSH
- Publikační typ
- kazuistiky MeSH
- MeSH
- cizí tělesa * farmakoterapie chirurgie veterinární MeSH
- psi MeSH
- reakce na cizí těleso farmakoterapie chirurgie veterinární MeSH
- špičák MeSH
- ústní sliznice * zranění MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- zvířata MeSH
- Publikační typ
- kazuistiky MeSH
- MeSH
- acepromazin aplikace a dávkování škodlivé účinky MeSH
- alfa-2-adrenergní receptory - agonisté aplikace a dávkování škodlivé účinky MeSH
- anestetika * aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- anestezie a analgezie * metody veterinární MeSH
- centrálně působící myorelaxancia škodlivé účinky terapeutické užití MeSH
- diazepam aplikace a dávkování škodlivé účinky MeSH
- hypnotika a sedativa * škodlivé účinky terapeutické užití MeSH
- injekce intramuskulární MeSH
- midazolam aplikace a dávkování škodlivé účinky MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
Používání digitálních systémů s sebou přináší i výskyt artefaktů, které mohou zkreslit až znehodnotit diagnostickou hodnotu snímků. Některé jsou podobné těm, které vznikají u analogových filmových systémů, jiné výhradně u digitálních systémů. Digitální artefakty lze rozdělit podle toho, ve které fázi zpracování vznikly. Cílem článku je roztřídit a popsat artefakty vzniklé při použití DR a CR systémů, nalézt příčinu vzniku a snížit jejich výskyt. Klíčová slova: paměťový rozptyl, praskliny, neúplné vymazání, fantomový obraz, převrácená kazeta, sekundární záření, nevycentrovaná (obrácená) mřížka, dvojexpozice, zašumění snímku, saturace, průnik světla, vadnutí, nečistoty, znečištěný světlovod, vynechávání skenovanýchí řádků, moiré, chybný přenos, vymezení okrajů – hraniční detekce, diagnostická specifikace, ořez, prahová hustota, přestřel (überschwinger), paměť, mrtvé pixely, kalibrační maska, efekt paradoxní přeexpozice, pruhování, radiofrekvenční šum.
The using of digital systems brings the incidence of artifacts that can distort to degrade the diagnostic value of images. Some are similar to those that occur in film-screen systems, others exclusively in digital systems. Digital artifacts can be divided depending on what stage of processing incurred This article aims to describe and categorize artifacts arising from the use of DR and CR systems, to find the cause of origin and reduce their occurrence. Key words: storage scatter, cracks, partial erasure, phantom image, upside-down cassette, backscatter, grid cutoff, double exposure, quantum mottle, saturation, light leak, fading, debris, dirty light guide, skipped scan lines, moiré,faulty transfer, border detection, diagnostic specifier, clipping, density threshold, überschwinger, memory, dead pixels, calibration mask,paradoxic overexposure effect, planking, radiofrequency interference.
- MeSH
- artefakty * MeSH
- komprese dat MeSH
- počítačové zpracování obrazu MeSH
- radiologie * MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
Dostupnost digitální radiografie ve veterinární praxi rychle stoupá a tak v posledních letech dochází k rychlému přechodu od konvenční-filmové radiografie k digitálním systémům. Účelem tohoto článku je poskytnout informace, které jsou důležité zejména při rozhodování se o vhodnosti toho kterého zařízení pro danou praxi. Digitální radiografie se zpravidla dělí na nepřímou (CR) využívající kazety s paměťovou fólií a přímou (DR) využívající k vytvoření obrazu různé typy detektorů. Dalšími faktory podílejícími se na kvalitě snímku jsou parametry počítačové sestavy (procesor, grafícká karta, monitor) a programové vybavení - zpracování a archivace snímků. Kvalita obrazu je dána řadou parametrů, které spolu zce souvisí a jsou podobné jako v digitální fotografii (počet a velikostí pbcelu, velikost snímače, rozlišovací schopnost, dynamický rozsah), ale i dalších jako je např. detekční kvantová účinnost (DQE), specifický ukazatel udávající účinnost snímače. Porovnání diagnostické výtěžnosti hovoří jednoznačně ve prospěch digitální radiografie a snad jediná výhoda analogové rentgenografie - rozlišovací schopnost se s použitím nových materiálů v digitální rentgenografii postupně snižuje.
The availability of digital radiography equipment to veterinarians is increasing rapidly, and during the past several years, there has been a rapid transition from conventional film-screen radiography to digital systems.The purpose of this article is to provide information that is particularly important in determining the suitability of a device for the practice. Digital radiography is usually divided into indirect (CR) using storage-phosphor image plates and direct (DR) to create an image using different types of detectors. Additional factors involved in image quality parameters are computer configurations (processor, graphics card, display monitor) and software - processing and archiving of images.The image quality is determined by a number of parameters, which are dosely related and are similar to digital photography (number and pixel size, sensor size, resolution, dynamic range), but also other such as detective quantum efficiency (DQE), a specific indicator indicating the effectiveness of the sensor. Comparison of diagnostic yield speaks clearly in favor of digital radiography and perhaps the only advantage of analog radiography - resolution with the use of new materials in digital radiography gradually decreases.
- MeSH
- radiografie přístrojové vybavení MeSH
- veterinární lékařství MeSH
- vylepšení rentgenového snímku * přístrojové vybavení MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- přehledy MeSH