AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- echokardiografie MeSH
- intervenční radiografie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé středního věku MeSH
- lidé MeSH
- odstranění implantátu * metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční katetrizace * metody přístrojové vybavení MeSH
- srdeční katétry MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Pulmonary hypertension is a group of diseases characterized by elevated pulmonary artery pressure and pulmonary vascular resistance with significant morbidity and mortality. The most prevalent type is pulmonary hypertension secondary to left heart disease (PH-LHD). The available experimental models of PH-LHD use partial pulmonary clamping by technically nontrivial open-chest surgery with lengthy recovery. We present a simple model in which the reduction of the cross-sectional area of the ascending aorta is achieved not by external clamping but by partial intravascular obstruction without opening the chest. In anesthetized rats, a blind polyethylene tubing was advanced from the right carotid artery to just above the aortic valve. The procedure is quick and easy to learn. Three weeks after the procedure, left heart pressure overload was confirmed by measuring left ventricular end-diastolic pressure by puncture (1.3 ± 0.2 vs. 0.4 ± 0.3 mmHg in controls, mean ± SD, P < 0.0001). The presence of pulmonary hypertension was documented by measuring pulmonary artery pressure by catheterization (22.3 ± 2.3 vs. 16.9 ± 2.7 mmHg, P = 0.0282) and by detecting right ventricular hypertrophy and increased muscularization of peripheral pulmonary vessels. Contributions of a precapillary vascular segment and vasoconstriction to the increased pulmonary vascular resistance were demonstrated, respectively, by arterial occlusion technique and by normalization of resistance by a vasodilator, sodium nitroprusside, in isolated lungs. These changes were comparable, but not additive, to those induced by an established pulmonary hypertension model, chronic hypoxic exposure. Intravascular partial aortic obstruction offers an easy model of pulmonary hypertension induced by left heart disease that has a vasoconstrictor and precapillary component.NEW & NOTEWORTHY We present a new, simple model of a clinically important type of pulmonary hypertension, that induced by left heart failure. Left ventricular pressure overload is induced in rats by inserting a blinded cannula into the ascending aorta via carotid artery access. This partial intravascular aortic obstruction, which does not require opening of the chest and prolonged recovery, causes pulmonary hypertension, which has a precapillary and vasoconstrictor as well as a vascular remodeling component.
- MeSH
- aorta * patofyziologie patologie MeSH
- arteria pulmonalis patofyziologie patologie MeSH
- cévní rezistence MeSH
- hypertrofie pravé komory srdeční patofyziologie etiologie MeSH
- krysa rodu rattus MeSH
- modely nemocí na zvířatech * MeSH
- plicní hypertenze * patofyziologie etiologie MeSH
- potkani Sprague-Dawley MeSH
- potkani Wistar MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Wearable cardioverter-defibrillators (WCDs) are indicated in patients at risk of sudden cardiac arrest who are not immediate candidates for implantable defibrillator therapy. Limitations of existing WCDs include poor compliance and high false alarm rates. The Jewel is a novel patch-WCD (P-WCD) that addresses these limitations with an adhesive-based design for near-continuous wear and a machine learning algorithm designed to minimize inappropriate detections. This was a first-in-human study of the Jewel P-WCD conducted in an electrophysiology (EP) lab to determine the safety and effectiveness of the device in terminating ventricular tachycardia/ventricular fibrillation (VT/VF) with a single shock. The aim was to evaluate the safety and effectiveness of terminating VT/VF with a single shock using the Jewel P-WCD. METHODS AND RESULTS: This was a first-in-human, prospective, single-arm, single-centre study in patients scheduled for an EP procedure in which VT/VF was expected to either spontaneously occur or be induced. The Jewel P-WCD was placed on consented patients; upon confirmation of VT/VF, a single shock (150 J) was delivered via the device. A group sequential design and Pocock alpha spending function was used to measure the observed proportion of successful VT/VF single-shock terminations. The endpoint was achieved if the lower confidence limit exceeded the performance goal of 62%, using a one-sided lower 97.4% exact confidence bound. Of 18 eligible subjects, 16 (88.9%, 97.4% confidence bound: 65.4%) were successfully defibrillated with a single shock, exceeding the primary endpoint performance goal with no adverse events. CONCLUSION: This first-in-human evaluation of the Jewel P-WCD demonstrated the safety and effectiveness of terminating VT/VF. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/; Unique identifier: NCT05490459.
- MeSH
- defibrilátory * MeSH
- design vybavení MeSH
- dospělí MeSH
- elektrická defibrilace * přístrojové vybavení škodlivé účinky MeSH
- fibrilace komor * terapie diagnóza MeSH
- komorová tachykardie * terapie diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- nositelná elektronika * MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.
BACKGROUND: Anderson-Fabry disease (AFD) is an X-linked inherited lysosomal disease caused by a defect in the gene encoding lysosomal enzyme α-galactosidase A (GLA). Atrio-ventricular (AV) nodal conduction defects and sinus node dysfunction are common complications of the disease. It is not fully elucidated how frequently AFD is responsible for acquired AV block or sinus node dysfunction and if some AFD patients could manifest primarily with spontaneous bradycardia in general population. The purpose of study was to evaluate the prevalence of AFD in male patients with implanted permanent pacemaker (PM). METHODS: The prospective multicentric screening in consecutive male patients between 35 and 65 years with implanted PM for acquired third- or second- degree type 2 AV block or symptomatic second- degree type 1 AV block or sinus node dysfunction was performed. RESULTS: A total of 484 patients (mean age 54 ± 12 years at time of PM implantation) were enrolled to the screening in 12 local sites in Czech Republic. Out of all patients, negative result was found in 481 (99%) subjects. In 3 cases, a GLA variant was found, classified as benign: p.Asp313Tyr, p.D313Y). Pathogenic GLA variants (classical or non-classical form) or variants of unclear significance were not detected. CONCLUSION: The prevalence of pathogenic variants causing AFD in a general population sample with implanted permanent PM for AV conduction defects or sinus node dysfunction seems to be low. Our findings do not advocate a routine screening for AFD in all adult males with clinically significant bradycardia.
- MeSH
- atrioventrikulární blokáda * diagnóza epidemiologie terapie MeSH
- bradykardie komplikace terapie MeSH
- dospělí MeSH
- Fabryho nemoc * diagnóza epidemiologie genetika MeSH
- kardiostimulátor * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- syndrom chorého sinu diagnóza epidemiologie terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: During atrial fibrillation ablations using thermal energy, the treatment effect is attributed to not just pulmonary vein isolation (PVI), but also to modulation of the autonomic nervous system by ablation of cardiac ganglionated plexi (GP). OBJECTIVES: This study sought to assess the impact of pulsed field ablation (PFA) on the GP in patients undergoing PVI. METHODS: In the retrospective phase, heart rate was assessed pre- versus post-PVI using PFA, cryoballoon ablation, or radiofrequency ablation. In the prospective phase, a pentaspline PFA catheter was used in a protocol: 1) pre-PFA, high-frequency stimulation (HFS) identified GP sites by vagal effects; 2) PVI was performed assessing for repetitive vagal effects over each set of PF applications; 3) mapping defined PVI extent to identify those GP in the ablation zone; and 4) repeat HFS at GP sites to assess for persistence of vagal effects. RESULTS: Between baseline and 3 months, heart rates in the retrospective radiofrequency ablation (n = 40), cryoballoon (n = 40), and PFA (n = 40) cohorts increased by 8.9 ± 11.4, 11.1 ± 9.4, and -0.1 ± 9.2 beats/min, respectively (P= 0.01 PFA vs radiofrequency ablation; P= 0.01 PFA vs cryoballoon ablation). In the prospective phase, pre-PFA HFS in 20 additional patients identified 65 GP sites. During PFA, vagal effects were noted in 45% of first PF applications, persisting through all applications in 83%. HFS post-PFA reproduced vagal effects in 29 of 38 sites (76%) in low-voltage tissue. CONCLUSIONS: PFA has minimal effect on GP. Unlike with thermal ablation, the mechanism by which PFA treats atrial fibrillation is mediated solely by durable PVI.
- MeSH
- fibrilace síní * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé MeSH
- nervus vagus chirurgie MeSH
- prospektivní studie MeSH
- retrospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Publikační typ
- abstrakt z konference MeSH
BACKGROUND: Although pulmonary vein isolation (PVI) is an established procedure for atrial fibrillation (AF), non-PV foci play a crucial role in AF recurrence. Persistent left superior vena cava (PLSVC) has been reported as critical non-PV foci. However, the effectiveness of provocation of AF triggers from PLSVC remains unclear. This study was designed to validate the usefulness of provoking AF triggers from PLSVC. METHODS: This multicenter retrospective study included 37 patients with AF and PLSVC. To provoke triggers, AF was cardioverted, and re-initiation of AF was monitored under high-dose isoproterenol infusion. The patients were divided into two groups: those whose PLSVC had arrhythmogenic triggers initiating AF (Group A) and those whose PLSVC did not have triggers (Group B). Group A underwent isolation of PLSVC after PVI. Group B received PVI only. RESULTS: Group A had 14 patients, whereas Group B had 23 patients. After a 3-year follow-up, no difference in the success rate for maintaining sinus rhythm was observed between the two groups. Group A was significantly younger and had lower CHADS2-VASc scores than Group B. CONCLUSIONS: The provocation of arrhythmogenic triggers from PLSVC was effective for the ablation strategy. PLSVC electrical isolation would not be necessary if arrhythmogenic triggers are not provoked.
- Publikační typ
- časopisecké články MeSH