AIMS: Among patients with cardiogenic shock, immediate initiation of extracorporeal membrane oxygenation (ECMO) did not demonstrate any benefit at 30 days. The present study evaluated 1-year clinical outcomes of the Extracorporeal Membrane Oxygenation in the therapy of Cardiogenic Shock (ECMO-CS) trial. METHODS AND RESULTS: The ECMO-CS trial randomized 117 patients with severe or rapidly progressing cardiogenic shock to immediate initiation of ECMO or early conservative strategy. The primary endpoint for this analysis was 1-year all-cause mortality. Secondary endpoints included a composite of death, resuscitated cardiac arrest or implantation of another mechanical circulatory support device, duration of mechanical ventilation, and the length of intensive care unit (ICU) and hospital stays. In addition, an unplanned post-hoc subgroup analysis was performed. At 1 year, all-cause death occurred in 40 of 58 (69.0%) patients in the ECMO arm and in 40 of 59 (67.8%) in the early conservative arm (hazard ratio [HR] 1.02, 95% confidence interval [CI] 0.66-1.58; p = 0.93). The composite endpoint occurred in 43 (74.1%) patients in the ECMO group and in 47 (79.7%) patients in the early conservative group (HR 0.83, 95% CI 0.55-1.25; p = 0.29). The durations of mechanical ventilation, ICU stay and hospital stay were comparable between groups. Significant interaction with treatment strategy and 1-year mortality was observed in subgroups according to baseline mean arterial pressure (MAP) indicating lower mortality in the subgroup with low baseline MAP (<63 mmHg: HR 0.58, 95% CI 0.29-1.16; pinteraction = 0.017). CONCLUSIONS: Among patients with severe or rapidly progressing cardiogenic shock, immediate initiation of ECMO did not improve clinical outcomes at 1 year compared to the early conservative strategy. However, immediate ECMO initiation might be beneficial in patients with advanced haemodynamic compromise.
- MeSH
- časové faktory MeSH
- jednotky intenzivní péče MeSH
- kardiogenní šok * terapie mortalita MeSH
- lidé středního věku MeSH
- lidé MeSH
- mimotělní membránová oxygenace * metody MeSH
- míra přežití trendy MeSH
- senioři MeSH
- umělé dýchání metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- echokardiografie MeSH
- intervenční radiografie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé středního věku MeSH
- lidé MeSH
- odstranění implantátu * metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční katetrizace * metody přístrojové vybavení MeSH
- srdeční katétry MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.
BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly being used for circulatory support in patients with cardiogenic shock, although the evidence supporting its use in this context remains insufficient. The ECMO-CS trial (Extracorporeal Membrane Oxygenation in the Therapy of Cardiogenic Shock) aimed to compare immediate implementation of VA-ECMO versus an initially conservative therapy (allowing downstream use of VA-ECMO) in patients with rapidly deteriorating or severe cardiogenic shock. METHODS: This multicenter, randomized, investigator-initiated, academic clinical trial included patients with either rapidly deteriorating or severe cardiogenic shock. Patients were randomly assigned to immediate VA-ECMO or no immediate VA-ECMO. Other diagnostic and therapeutic procedures were performed as per current standards of care. In the early conservative group, VA-ECMO could be used downstream in case of worsening hemodynamic status. The primary end point was the composite of death from any cause, resuscitated circulatory arrest, and implementation of another mechanical circulatory support device at 30 days. RESULTS: A total of 122 patients were randomized; after excluding 5 patients because of the absence of informed consent, 117 subjects were included in the analysis, of whom 58 were randomized to immediate VA-ECMO and 59 to no immediate VA-ECMO. The composite primary end point occurred in 37 (63.8%) and 42 (71.2%) patients in the immediate VA-ECMO and the no early VA-ECMO groups, respectively (hazard ratio, 0.72 [95% CI, 0.46-1.12]; P=0.21). VA-ECMO was used in 23 (39%) of no early VA-ECMO patients. The 30-day incidence of resuscitated cardiac arrest (10.3.% versus 13.6%; risk difference, -3.2 [95% CI, -15.0 to 8.5]), all-cause mortality (50.0% versus 47.5%; risk difference, 2.5 [95% CI, -15.6 to 20.7]), serious adverse events (60.3% versus 61.0%; risk difference, -0.7 [95% CI, -18.4 to 17.0]), sepsis, pneumonia, stroke, leg ischemia, and bleeding was not statistically different between the immediate VA-ECMO and the no immediate VA-ECMO groups. CONCLUSIONS: Immediate implementation of VA-ECMO in patients with rapidly deteriorating or severe cardiogenic shock did not improve clinical outcomes compared with an early conservative strategy that permitted downstream use of VA-ECMO in case of worsening hemodynamic status. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02301819.
- MeSH
- hemodynamika MeSH
- kardiogenní šok diagnóza terapie MeSH
- lidé MeSH
- mimotělní membránová oxygenace * metody MeSH
- mortalita v nemocnicích MeSH
- retrospektivní studie MeSH
- srdeční zástava * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
Transcatheter aortic valve replacement (TAVR) is a minimally invasive therapeutic procedure with a consistent, linear increase in the number of implantations worldwide. Recently, TAVR has been rapidly expanding into lower-risk populations. Sporadic cases of late prosthesis-related Stanford type A dissection have been documented in self-expanding, as well as balloon-expandable TAVR valves, manifested primarily as acute aortic syndrome. We present the case of a 76-year-old male, who experienced refractory in-hospital cardiac arrest with non-shockable rhythm due to the obstruction of coronary flow caused by aortic dissection type A, with entry directly adjacent to the aortic prosthesis according to autopsy. The patient died despite the engagement of extracorporeal cardiopulmonary resuscitation. Aortic dissection developed one year after a transfemoral TAVR procedure using an Edwards SAPIEN 3 29 mm self-expanding valve. TAVR-associated late aortic dissection type A represents a rare, life-threatening condition with various clinical manifestations. The risk factors have not been well described and the differential diagnosis may be challenging. As the number of TAVR recipients and their life expectancy is increasing, we may face this complication more often in future.
- Publikační typ
- kazuistiky MeSH
There are substantial differences in autonomic nervous system activation among heart (cardiac) failure (CF) patients. The effect of acute CF on autonomic function has not been well explored. The aim of our study was to assess the effect of experimental acute CF on heart rate variability (HRV). Twenty-four female pigs with a mean body weight of 45 kg were used. Acute severe CF was induced by global myocardial hypoxia. In each subject, two 5-min electrocardiogram segments were analyzed and compared: before the induction of myocardial hypoxia and >60 min after the development of severe CF. HRV was assessed by time-domain, frequency-domain and nonlinear analytic methods. The induction of acute CF led to a significant decrease in cardiac output, left ventricular ejection fraction and an increase in heart rate. The development of acute CF was associated with a significant reduction in the standard deviation of intervals between normal beats (50.8 [20.5−88.1] ms versus 5.9 [2.4−11.7] ms, p < 0.001). Uniform HRV reduction was also observed in other time-domain and major nonlinear analytic methods. Similarly, frequency-domain HRV parameters were significantly changed. Acute severe CF induced by global myocardial hypoxia is associated with a significant reduction in HRV.