Aortic dissection is a biomechanical phenomenon associated with a failure of internal cohesion, which manifests itself through the delamination of the aortic wall. The goal of this study is to deepen our knowledge of the delamination strength of the aorta. To achieve this, 661 peeling experiments were carried out with strips of the human aorta collected from 46 cadavers. The samples were ordered into groups with respect to (1) anatomical location, (2) orientation of the sample, and (3) extension rate used within the experiment. The obtained results are in accordance with the hypothesis that delamination resistance is not sensitive to the extension rates 0.1, 1, 10, and 50 mms-1. We arrived at this conclusion for all positions along the aorta investigated in our study. These were the thoracic ascending (AAs), thoracic descending (ADs), and the abdominal aorta (AAb), simultaneously considering both the longitudinal (L) as well as the circumferential (C) orientations of the samples. On the other hand, our results showed that the delamination strength differs significantly with respect to the anatomical position and orientation of the sample. The medians of the delamination strength were as follows, 4.1 in AAs-L, 3.2 in AAs-C, 3.1 in ADs-L, 2.4 in ADs-C, AAb-L in 3.6, and 2.7 in AAb-C case (all values are in 0.01·Nmm-1). This suggests that resistance to crack propagation should be an anisotropic property and that the aorta is inhomogeneous along its length from the point of view of delamination resistance. Finally, correlation analysis proved that the delamination strength of the human aorta significantly decreases with age.
- MeSH
- anizotropie MeSH
- aorta abdominalis MeSH
- aorta thoracica MeSH
- biomechanika MeSH
- disekce aorty * MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
This work concerns a biomechanical study aiming to ascertain the optimal type of joint resection when performing a joint arthrodesis. A 3-dimensional digital model of the first metatarsophalangeal joint including the entire first metatarsal bone and proximal phalanx using CT scans of the forefoot was created. Using this computer model, 4 types of resections; ball-and-socket, flat-on-flat, wedge 90°, and wedge 100° were simulated. Parameters measured using this model were the force necessary to separate the 2 fused surfaces, the surface area of the resected surfaces and the shortening of the first ray. By measuring the reactive force necessary to separate the phalanx from the first metatarsal, the 90° wedge resection was found to be the most stable, with comparable results in the case of the 100° wedge resection. Wedge resections are also more favorable when comparing the shortening of the first ray. Wedge resections, though being more technically difficult to perform prove to be the most stable for metatarsophalangeal joint-1 arthrodesis using this model.
Úvod: Cílem studie byla laboratorní „in vitro“ modelace zatížení defektu předního sloupce páteře ošetřeného transpedikulární fixací na kadaverozním preparátu a jeho biomechanické měření. Materiál a metoda: Celkem byly získány 4 kadaverozní modely hrudní páteře v rozsahu Th3-L2. Anatomická preparace byla provedena se zachováním základních kostních a vazivových struktur. Pro vlastní měření byly připraveny celkem 3modely, celkem 1 preparát byl ošetřen transpedikulární instrumentací 1+1 a celkem 2 preparáty ošetřeny instrumentací 2+2. V průběhu vlastního měření a kalibrace přístroje byl na úrovni Th6/7 proveden vlastní defekt předního sloupce resekcí meziobratlové ploténky. Pro vlastní měření byl využit testovací systém MTS 858,2 Mini Bionix v sestavě s víceosým simulátorem. K měření deformací fixace byl použit extenzometr MTS s pracovním rozsahem +/- 0,4 mm. Z tuhostních charakteristik jednotlivých pohybů je možné odečíst základní parametry měřeného vzorku tj. neutrální zóna, elastická zóna, rozsah pohybu soustavy. Výsledky: Hodnocení tuhosti soustavy fl./ext. a dukce po vytvoření defektu předního sloupce páteře dochází k progresi nárůstu hodnocených parametrů bez ohledu na vzorek nebo typ montáže s výslednou směrovou asymetrií ve směru převahy extenze proti flexi a jednotlivých směrů dukce. V hodnocení napětí na fixačních tyčích vykazuje také nárůst napětí po provedení defektu předního sloupce páteře. Z hlediska absolutních hodnot je nejméně zatížena instrumentace vzorku 1+1. Diskuze: Z vyhodnocení napětí na fixačních tyčích je možné interpretovat dva obecné závěry. Prvním výsledkem je zvýšení napětí na spojovací tyči konstrukce po destabilizaci páteře, druhým závěrem je nezanedbatelná asymetrie výsledných hodnot na pravé a levé tyči. V tuhostních charakteristikách vzorku se v celém rozsahu zatížení nevyskytují žádné skokové změny tuhosti, které by ukazovaly k možnému selhání konstrukce.
Introduction: The aim of the biomechanical study was laboratory „in-vitro“ testing and measurement of spinal column axial loading. The biomechanical simulation tested the thoracolumbar spinal cadaver with anterior column defect instrumented by the transpedicular fixation. Material and method: The study group (4 spinal cadavers Th3-L2) were anatomically prepared in the anatomy lab conserving the bone, disc and ligament structures and subsuquently instrumented by the transpedicular fixation. There were 2groups (2 + 2 cadavers), the first group were transpediculary instrumented 1+1 segment and the second by 2+2 segments. One spinal cadaver from the first group was unable for the final biomechanical testing, because of spinal deformity, rest 3 cadavers were finally measured. The proper biomechanical testing, were done on the testing system MTS 858,2 Mini-Bionix with extensometr MTS, tested the axial loading of spinal column (flexion, extension, duction) with parametric results of total range of motion, neutral, elastic zone a rod deformation. The anterior column defects were done during the proper testing by the disc Th6/7 resection. Results: There were progression in all assessed parametres /range of motion, elastic, neutral zone, rod deformation) with considerable asymetry direction in extension to flexion and duction in spinal column loading with anterior defect. The rod deformation decrease with extent of transpedicular instrumentation. Discussion: The range of motion (elastic zone, neutral zone) and instrumentation rod strain in the measured system (spinal cadaver) increase in plane asymetry in the spinal column with anterior defect. The rigidity of the spinal transpedicular instrumentation (rod deformation) increase continuously without any skip transmutations and there is no risk factor of possible loosening of constructions in calibrated conditions.
- Klíčová slova
- celkový rozsah pohybu, elastická zóna, instantní centrum rotace, neutrální zóna,
- MeSH
- biomechanika MeSH
- design vybavení MeSH
- interní fixátory MeSH
- lidé MeSH
- mrtvola MeSH
- ortopedické fixační pomůcky MeSH
- páteř chirurgie patofyziologie MeSH
- poranění páteře chirurgie MeSH
- testování materiálů metody přístrojové vybavení MeSH
- zatížení muskuloskeletálního systému MeSH
- Check Tag
- lidé MeSH
Persistence of immune response was assessed in adults aged >40 years (N = 596) following primary vaccination with combined hepatitis A/B vaccine or concomitant monovalent hepatitis A and B vaccines. Anti-hepatitis A virus antibody responses persisted for at least 4 years regardless of the vaccine used, with anti-hepatitis B surface antibody responses higher and more sustained in subjects who received the combined hepatitis A/B vaccine. Response rates to an additional dose of the same vaccine(s) used for priming were high.
- MeSH
- dospělí MeSH
- hepatitida A - protilátky krev MeSH
- hepatitida A prevence a kontrola MeSH
- hepatitida B - protilátky krev MeSH
- hepatitida B prevence a kontrola MeSH
- imunologická paměť MeSH
- kombinované vakcíny imunologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- sekundární imunizace MeSH
- vakcína proti hepatitidě A aplikace a dávkování imunologie MeSH
- vakcína proti hepatitidě B aplikace a dávkování imunologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
300 adolescents aged 12-15 years were randomised (1:1) into two groups to compare the long-term (10 years) immunogenicity profile of two doses of an Adult formulation [Group HAB_2D: 150; 0-6 months] vs. three doses of a Paediatric formulation [Group HAB_3D: 150; 0-1-6 months] of a combined hepatitis A and B (HAB) vaccine. At Year 10, anti-HAV seropositivity rate was 100% in both groups, while 85.9% and 85.1% subjects in the HAB_2D and HAB_3D groups, respectively, had anti-HBs antibody concentrations > or =10 mIU/mL. The anti-HAV antibody GMCs (HAB_2D: 429.3 mIU/mL; HAB_3D: 335.5 mIU/mL) and anti-HBs antibody GMCs (HAB_2D: 50.6 mIU/mL; HAB_3D: 60.1 mIU/mL) were similar in both groups. No vaccine-related serious adverse events were reported. Hence, with respect to long-term antibody persistence, the two-dose schedule of the combined HAB vaccine Adult formulation is an effective alternative to the conventional three-dose schedule of the Paediatric formulation in adolescents.
- MeSH
- hepatitida A - protilátky krev MeSH
- hepatitida A imunologie prevence a kontrola MeSH
- hepatitida B - protilátky krev MeSH
- hepatitida B imunologie prevence a kontrola MeSH
- kombinované vakcíny aplikace a dávkování imunologie MeSH
- lidé MeSH
- mladiství MeSH
- následné studie MeSH
- očkovací schéma MeSH
- vakcína proti hepatitidě A aplikace a dávkování imunologie MeSH
- vakcína proti hepatitidě B aplikace a dávkování imunologie MeSH
- Check Tag
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
- Klíčová slova
- WOBENZYM, PHLOGENZYM,
- MeSH
- enzymy aplikace a dávkování terapeutické užití MeSH
- gynekologická onemocnění farmakoterapie MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Klíčová slova
- WOBENZYM, PHLOGENZYM,
- MeSH
- enzymy terapeutické užití MeSH
- gynekologie MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH