CE method for the baseline separation of structurally similar flavonolignans silybin A, silybin B, isosilybin A, isosilybin B, silychristin, silydianin, and their precursor taxifolin in silymarin complex has been developed and validated. The optimized background electrolyte was 100 mmol/L boric acid (pH 9.0) containing 5 mmol/L heptakis(2,3,6-tri-O-methyl)-β-CD and 10% (v/v) of methanol. The separation was carried out in an 80.5/72 cm (50 μm id) fused silica capillary at +25 kV with UV detection at 200 nm. Genistein (10 μg/mL) was used as internal standard. The resolution between the diastereomers of silybin and isosilybin was 1.73 and 2.59, respectively. The method was validated for each analyte in a concentration range of 2.5-50 μg/mL. The calibration curves were rectilinear with correlation coefficients ≥0.9972. The method was applied to determine flavonolignans in two dietary supplements containing Silybum marianum extract. The accuracy was evaluated by comparing the results of the CE analyses of the dietary supplements with those of the reference United States Pharmacopeial HPLC method. The unpaired t-test did not show a statistically significant difference between the results of both the proposed CE and the reference method (p > 0.05, n = 3).
A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm-2 h-1 for Canesten, 35 µg cm-2 h-1 for Clotrimazol AL, and 7.2 µg cm-2 h-1 for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.
We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes. Packing of ca. 4.4 mg microSPE columns from Oasis HLB® sorbent slurry was performed for each sample analysis using a simple microcolumn adapted to the Lab-On-Valve manifold to achieve low backpressure during loading. Eluted analytes were injected into online coupled HPLC with subsequent separation on a Symmetry C18 column in isocratic mode. The optimized method was highly reproducible, with RSD values of 3.2% to 7.6% on 20 µg L-1 level. Linearity was confirmed up to 200 µg L-1 and LOD values were between 0.06 and 1.98 µg L-1. Recovery factors between 91 and 109% were obtained in the analysis of spiked surface water samples.
The new screening method for rapid evaluation of major phenolic compounds in apples has been developed. Suitability of coupling HPLC/UHPLC separation with the diode-array detection and universal charged aerosol detection with respect to the presence of interfering substances was tested. Characteristics of both detection techniques were compared and method linearity, limits of detection and quantitation, and selectivity of them determined. Student t-test based on slopes of calibration plots was applied for the detailed comparison. The diode-array detection provided the best results regarding sensitivity and selectivity of the developed method in terms of evaluation of phenolics profiles. The response of the charged aerosol detector was negatively affected by co-eluting substances during rapid-screening analyses. Coulometric detection was used for advanced characterization of extracts in terms of antioxidant content and strength to obtain more complex information concerning sample composition. This detection also allowed evaluation of unidentified compounds with antioxidant activity. HPLC/UHPLC separation using a combination of diode-array and coulometric detectors thus represented the best approach enabling quick, yet complex characterization of bioactive compounds in apples.
- MeSH
- Aerosols chemistry MeSH
- Antioxidants chemistry MeSH
- Chromatography methods MeSH
- Electrochemistry methods MeSH
- Phenol chemistry MeSH
- Phenols analysis MeSH
- Calibration MeSH
- Limit of Detection MeSH
- Malus metabolism MeSH
- Food Technology MeSH
- Reproducibility of Results MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Publication type
- Journal Article MeSH
Fipronil is an insecticide that is not approved in the European Union in food. In 2017, fipronil was involved in a European health alert due to its presence in fresh hen eggs because of an illicit use in poultry farms, so reliable methods are needed to determine fipronil and its main metabolites in these matrixes. In this work, we report the first approach to the study of fipronil and two metabolites, fipronil-sulfone and fipronil-sulfide by CE. MEKC mode was employed using a solution of 50 mM ammonium perfluorooctanoate pH 9.0 with 10% (v/v) methanol as background electrolyte. The proposed method was combined with a simple sample treatment based on salting-out assisted LLE (SALLE) using acetonitrile as extraction solvent and ammonium sulfate as salt. The SALLE-MEKC-UV method allowed the simultaneous quantification of fipronil and fipronil-sulfone. Validation parameters yielded satisfactory results, with precision, expressed as relative SD, below 14% and recoveries higher than 83%. Limits of detection were 90 µg/kg for fipronil and 150 µg/kg for fipronil-sulfone, so in terms of sensitivity further studies of sample treatments allowing extra preconcentration or the use of more sensitive detection, such as MS, would be needed.
- MeSH
- Acetonitriles MeSH
- Chromatography, Micellar Electrokinetic Capillary methods MeSH
- Insecticides MeSH
- Chickens MeSH
- Limit of Detection MeSH
- Linear Models MeSH
- Pyrazoles analysis MeSH
- Reproducibility of Results MeSH
- Eggs analysis MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The new ultra-high performance liquid chromatography method with tandem mass spectrometry detection (UHPLC-MS/MS) has been optimized to allow fast, selective, and high-throughput analysis of two Candida albicans quorum sensing molecules (QSM), farnesol and tyrosol. The problem of the presence of the interference in the samples and system was successfully solved by careful optimization of chromatographic conditions. Charged hybrid stationary phase modified with pentafluorophenyl group and optimized gradient elution provided adequate separation selectivity and peak shapes. The impurity was identified as dibutyl phthalate and had the same m/z ions as farnesol leading to an important interference on selected reaction monitoring channel. Two different types of biological matrices originating from vaginal fluid, supernatant and sediment, were analysed. Micro-solid phase extraction in pipette tips was optimized for the selective isolation of QSM from the supernatant. The insufficient retention of farnesol on the extraction sorbent was improved when 1% of organic solvent was added prior to extraction, while the retention of tyrosol was only possible when using combined C8 and polymer sorbent type. Strong retention of farnesol had to be solved by increasing elution solvent strength and volume up to 600 μL. However, this approach did not allow the pretreatment of sediment samples due to the sorbent clogging. Therefore, our previously developed protein precipitation method was modified and validated to analyse the sediments. New developed UHPLC-MS/MS method provided suitable accuracy and precision for the determination of QSM in vaginal fluid while using only 50 μL sample volume and two different sample preparation methods.
- MeSH
- Candida albicans isolation & purification MeSH
- Adult MeSH
- Farnesol analysis MeSH
- Phenylethyl Alcohol analogs & derivatives analysis MeSH
- Middle Aged MeSH
- Humans MeSH
- Limit of Detection MeSH
- Young Adult MeSH
- Tandem Mass Spectrometry methods MeSH
- Vagina chemistry microbiology MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Validation Study MeSH