Endocardial pacing
Dotaz
Zobrazit nápovědu
BACKGROUND: A total of 30% to 40% of patients with congestive heart failure eligible for cardiac resynchronization therapy (CRT) either do not respond to conventional CRT or remain untreated due to an inability or impediment to coronary sinus (CS) lead implantation. The WiSE-CRT system (EBR Systems, Sunnyvale, California) was developed to address this at-risk patient population by performing biventricular pacing via a wireless left ventricular (LV) endocardial pacing electrode. OBJECTIVES: The SELECT-LV (Safety and Performance of Electrodes implanted in the Left Ventricle) study is a prospective multicenter non-randomized trial assessing the safety and performance of the WiSE-CRT system. METHODS: A total of 35 patients indicated for CRT who had "failed" conventional CRT underwent implantation of an LV endocardial pacing electrode and a subcutaneous pulse generator. System performance, clinical efficacy, and safety events were assessed out to 6 months post-implant. RESULTS: The procedure was successful in 97.1% (n = 34) of attempted implants. The most common indications for endocardial LV pacing were difficult CS anatomy (n =12), failure to respond to conventional CRT (n = 10), and a high CS pacing threshold or phrenic nerve capture (n = 5). The primary performance endpoint, biventricular pacing on the 12-lead electrocardiogram at 1 month, was achieved in 33 of 34 patients. A total of 28 patients (84.8%) had improvement in the clinical composite score at 6 months, and 21 (66%) demonstrated a positive echocardiographic CRT response (≥5% absolute increase in LV ejection fraction). There were no pericardial effusions, but serious procedure/device-related events occurred in 3 patients (8.6%) within 24 h, and 8 patients (22.9%) between 24 h and 1 month. CONCLUSIONS: The SELECT-LV study demonstrates the clinical feasibility for the WiSE-CRT system, and provided clinical benefits to a majority of patients within an otherwise "failed" CRT population. (Safety and Performance of Electrodes Implanted in the Left Ventricle [SELECT-LV]; NCT01905670).
- MeSH
- lidé středního věku MeSH
- lidé MeSH
- neúspěšná terapie MeSH
- prospektivní studie MeSH
- prostředky srdeční resynchronizační terapie škodlivé účinky statistika a číselné údaje MeSH
- senioři MeSH
- srdeční resynchronizační terapie škodlivé účinky statistika a číselné údaje MeSH
- srdeční selhání terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
Acta medica Scandinavica, ISSN 0001-3101 suppl. 502
110 s. : tab., il. ; 24 cm
AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.
PURPOSE OF REVIEW: To review and prioritize data on pediatric cardiac pacing published during the period of the last 18 months. RECENT FINDINGS: New approaches to preservation of ventricular function in pediatric pacing are based on recent publications confirming major influence of the ventricular pacing site on left ventricular (LV) function and synchrony. Current studies on epicardial vs. transvenous pacing continue to show survival superiority of endocardial leads. Long-term outcome of epicardial pacing may, however, be positively influenced by technical refinements. Recent amendments of the guidelines for cardiac resynchronization therapy (CRT) in adult idiopathic and ischemic cardiomyopathy are likely to influence CRT indications in children. Novel data give interesting insights into implantable cardioverter-defibrillator (ICD) lead survival as well as the use of ICDs in young patients with hypertrophic cardiomyopathy. SUMMARY: Pediatric cardiac pacing and ICD therapy is still a developing field likely to improve with technical refinements, proper lead placement and more specific therapy indications. The current review will give the reader information about recent developments and directions for the future.
- MeSH
- defibrilátory implantabilní MeSH
- dítě MeSH
- funkce levé komory srdeční MeSH
- kardiomyopatie komplikace MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- srdeční arytmie etiologie terapie MeSH
- srdeční resynchronizační terapie metody MeSH
- srdeční selhání etiologie terapie MeSH
- vrozené srdeční vady komplikace MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT system; EBR Systems, Sunnyvale, CA), without the requirement for lifelong anticoagulation. OBJECTIVE: The purpose of this study was to assess the safety and efficacy of the WiSE-CRT system during real-world clinical use in an international registry. METHODS: Data were prospectively collected from 14 centers implanting the WiSE-CRT system as part of the WiCS-LV Post Market Surveillance Registry. (ClinicalTrials.gov Identifier: NCT02610673). RESULTS: Ninety patients from 14 European centers underwent implantation with the WiSE-CRT system. Patients were predominantly male, age 68.2 ± 10.5 years, left ventricular ejection fraction 30.6% ± 8.9%, mean QRS duration 180.7 ± 27.0 ms, and 40% with ischemic etiology. Successful implantation and delivery of BiV ENDO pacing was achieved in 94.4% of patients. Acute (<24 hours), 1- to 30-day, and 1- to 6-month complications rates were 4.4%, 18.8%, and 6.7%, respectively. Five deaths (5.6%) occurred within 6 months (3 procedure related). Seventy percent of patients had improvement in heart failure symptoms. CONCLUSION: BiV ENDO pacing with the WiSE-CRT system seems to be technically feasible, with a high success rate. Three procedural deaths occurred during the study. Procedural complications mandate adequate operator training and implantation at centers with immediately available cardiothoracic and vascular surgical support.
- MeSH
- design vybavení MeSH
- endokard MeSH
- funkce levé komory srdeční fyziologie MeSH
- lidé MeSH
- prospektivní studie MeSH
- prostředky srdeční resynchronizační terapie * MeSH
- registrace * MeSH
- senioři MeSH
- srdeční komory patofyziologie MeSH
- srdeční resynchronizační terapie metody MeSH
- srdeční selhání patofyziologie terapie MeSH
- tepový objem fyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Leadless pacemakers (PMs) were recently introduced to address the complication rate of standard PMs with transvenous leads. METHODS AND RESULTS: A 34-year old male with a history of intravenous substance abuse and a chronic type C hepatitis developed a complete atrioventricular block after cardiac surgery for infective endocarditis. Repeatedly, endo- and epi-cardially implanted PMs had to be explanted due to infection. A leadless MICRA pacemaker was successfully implanted with a dislocation into pulmonary artery several days after implantation. The PM was successfully retrieved using a single-loop retrieval snare guided by a steerable sheath. Subsequently, another Micra PM was successfully implanted with no further issues. CONCLUSION: In the case of a Micra leadless pacemaker dislocation, a conventional gooseneck snare in combination with a steerable sheath can be used to retrieve the device, improving the overall safety of leadless pacemakers.
- MeSH
- bakteriální endokarditida etiologie chirurgie MeSH
- design vybavení MeSH
- dospělí MeSH
- implantace protézy škodlivé účinky metody MeSH
- kardiostimulátor škodlivé účinky mikrobiologie MeSH
- lidé MeSH
- následné studie MeSH
- odstranění implantátu metody MeSH
- srdeční arytmie patofyziologie chirurgie MeSH
- srdeční resynchronizační terapie metody MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
AIMS: To assess the acute side-effects of right ventricular (RV) stimulation applied in apex and mid-septum, in order to establish the optimal lead location in clinical practice. METHODS: During pacemaker implantation, the ventricular lead was temporarily fixed in the apex and then moved to mid-septum. In both positions, surface and endocardial electrograms and transvalvular impedance (32 cases), left ventricular (LV) pressure (23), and transthoracic echocardiography (10) were acquired with intrinsic activity and VDD pacing. RESULTS: A larger increase in QRS duration was noticed with apical than septal pacing (65±25 vs. 45±29 ms; P<10(-4)). The proportion of cases where RV stimulation affected the transvalvular impedance waveform was higher with apical lead location (56% vs. 20%; P<0.02). VDD pacing at either site reduced the maximum dP/dt by 6% with respect to intrinsic AV conduction (IAVC; P<0.005). The maximum pressure drop taking place in 100 ms was reduced by 6 and 8%, respectively, with apical and septal pacing (P<0.01 vs. IAVC). Apical VDD decreased mitral annulus velocity in early diastole (E') from 7.5±1.4 to 5.9±0.9 cm/s (P<0.02) and prolonged the E-wave deceleration time (DT) from 156±33 to 199±54 ms (P<0.02), while septal pacing induced non-significant modifications in E' and DT. CONCLUSION: Ventricular stimulation acutely impairs LV systolic and diastolic performance, independent of the pacing site. Septal lead location preserves RV contraction mechanics and reduces the electrical interventricular delay.
- MeSH
- echokardiografie MeSH
- elektrická impedance škodlivé účinky terapeutické užití MeSH
- elektrokardiografie MeSH
- hemodynamika fyziologie MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- lidé MeSH
- srdce - funkce komor fyziologie MeSH
- srdeční komory patofyziologie MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Right ventricular apical pacing has a detrimental effect on left ventricular (LV) function. More optimal pacing site may be found by invasive measurement of LV mechanical performance during pacing from different RV pacing sites. We aimed to investigate the effect of RV pacing lead location on invasive indices of LV mechanical performance. METHODS AND RESULTS: Patients undergoing catheter ablation for persistent atrial fibrillation were enrolled. Single-site endocardial pacing from the lateral LV region was periodically switched to pacing from the mapping catheter navigated to different RV sites within the three-dimensional electroanatomical RV map. SystIndex, DiastIndex, and PPIndex were defined as the ratio of LV dP/dtmax, LV dP/dtmin, and arterial pulse pressure during RV pacing to corresponding values from adjacent periods of LV pacing. Haemodynamic data were analysed in 18 RV segments created by dividing RV horizontally (basal, mid, and apical portion), vertically (inferior, mid, and superior portion) and frontally (septum and free wall). Eight patients (58 ± 7 years; 2 females; 26 ± 4 RV pacing sites per patient) were enrolled into the study. Compared with LV pacing, the best RV pacing values of SystIndex and DiastIndex were achieved in basal-mid-septal segment (+6.9%, P = 0.02 and +3.4%, P = 0.36, respectively) while the best PPIndex was obtained in superior-mid-septal segment of RV (+4.5%, P = 0.02). All indices were fairly concordant showing significant improvement of haemodynamics during RV pacing in the direction from free wall to septum, from apex to base, and from inferior to superior segments. CONCLUSION: The best LV mechanical performance was achieved by RV septal pacing in the non-apical mid-to-superior segments.
- MeSH
- časové faktory MeSH
- diastola * MeSH
- elektrofyziologické techniky kardiologické MeSH
- elektrokardiografie MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- funkce levé komory srdeční * MeSH
- funkce pravé komory srdeční * MeSH
- kardiostimulace umělá metody MeSH
- katetrizační ablace MeSH
- krevní tlak MeSH
- lidé středního věku MeSH
- lidé MeSH
- mezikomorová přepážka patofyziologie MeSH
- prediktivní hodnota testů MeSH
- srdeční komory patofyziologie MeSH
- systola * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH