BACKGROUND: The quantitative assessment of neuroblastoma cell content in bone marrow aspirates for response evaluation has been introduced recently. Data on the concordance of interobserver reports are lacking so far. METHODS: Investigators of seven European countries representing national reference or large oncological centers convened in 2016. They agreed to quantitatively assess routine bone marrow smears of the participating institutions and to discuss the discrepant results in joint meetings. RESULTS: From 2017 through 2019, three cytology rounds with 24, 28, and 28 bone marrow samples were run evaluating the representativity of the smears (yes/[restricted]/no) and the presence of tumor cells (yes/no and %). The comparison of the reports using κ (Fleiss) and α (Krippendorff) statistics demonstrated no robust reliabilities. The agreement on the representativity was moderate to poor, on the presence of tumor cells moderate to good, and on the percentage of tumor cells slight to moderate. Though the value of cytology is unquestioned to detect even tiny metastatic cells in bone marrow, the investigators unanimously agreed that a reliable quantification of the tumor cell content in bone marrow smears is unrealistic. For the key issue of representativity, a new practical definition was developed. CONCLUSION: For any work with bone marrow aspirates, the representativity of the material is of paramount importance. A practical definition is proposed. A reliable quantitative cytological assessment of tumor cell content in bone marrow aspirates is not feasible in metastatic neuroblastoma. Therefore, its use as response criterion should be reconsidered.
Standard pharmacokinetic (PK) assessments are demanding for persons with hemophilia A, requiring a 72-hour washout and 5 to 11 timed blood samples. A no-washout, single-clinic visit, sparse sampling population PK (PPK) protocol is an attractive alternative. Here, we compared PK parameters obtained with a traditional washout, 6-sampling time point PPK protocol with a no-washout, single-clinic visit, reverse 2-sampling time point PPK protocol in persons with severe hemophilia A (SHA) receiving ADVATE. A total of 39 inhibitor-negative males with SHA (factor VIII activity [FVIII:C] < 2%) were enrolled in a prospective sequential design PK study. Participants completed a washout, 6-sampling time point PPK protocol as well as a no-washout, reverse 2-sampling time point protocol, with samples taken during a single 3-hour clinic visit 24 hours post home infusion of FVIII and then 3 hours post infusion in clinic. FVIII:C levels were analyzed by one-stage and chromogenic assays; blood group and von Willebrand factor antigen (VWF:Ag) were determined; and PK parameters were analyzed using the ADVATE myPKFiT dosing tool. There was moderate to almost perfect agreement for the PK parameters obtained with the 2- and the 6- point PPK protocols using a one-stage FVIII:C assay and a substantial to almost perfect agreement using a chromogenic FVIII:C assay. Significant associations between specific PK parameters and blood group and VWF:Ag were observed. The no-washout, single-clinic visit, reverse 2-sampling time point PPK protocol can be used in the routine clinical setting since it demonstrates sufficient accuracy compared with the more demanding and less practical washout, 6-sampling time point PPK protocol in persons with SHA receiving ADVATE.
- MeSH
- ambulantní péče MeSH
- biologické modely MeSH
- dítě MeSH
- dospělí MeSH
- faktor VIII aplikace a dávkování farmakokinetika MeSH
- hemofilie A krev diagnóza farmakoterapie MeSH
- hemokoagulace účinky léků MeSH
- klinické protokoly MeSH
- koagulancia aplikace a dávkování krev farmakokinetika MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- monitorování léčiv * MeSH
- prediktivní hodnota testů MeSH
- předškolní dítě MeSH
- prospektivní studie MeSH
- senioři MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- srovnávací studie MeSH
- Geografické názvy
- Austrálie MeSH
- Česká republika MeSH
- Kanada MeSH
Essentials Von Willebrand ristocetin cofactor activity (VWF:RCo) is not a completely reliable assay. Three automated VWF activity assays were compared within a von Willebrand disease (VWD) cohort. Raw values for all three assays were virtually the same. An overall problem within type 2A/IIE VWD using VWF:GPIb-binding activity/VWF:Ag was observed. SUMMARY: Background von Willebrand disease (VWD) is an inherited bleeding disorder caused by quantitative (type 1 and 3) or qualitative (type 2) von Willebrand factor (VWF) defect. VWD diagnosis and classification require numerous laboratory tests. VWF: glycoprotein Ib (GPIb)-binding activity assays are used to distinguish type 1 from type 2 VWD. Objectives Three different automated VWF:GPIb-binding activity assays were compared. Patients and methods BC-VWF:RCo (Siemens Healthcare Diagnostics), HemosIL® VWF:RCo (Instrumentation Laboratory) and INNOVANCE® VWF:Ac (Siemens Healthcare Diagnostics) were performed in a well typed VWD cohort (n = 142). Results Based on the three most used VWD parameters (FVIII:C, VWF:Ag and VWF:GPIb-binding activity) and using a cut-off of <0.70 for type 2 VWD revealed sensitivity and specificity of, respectively, 92% and 72.4% for VWF:RCo/VWF:Ag, 84% and 89.7% for VWF:GPIbR/VWF:Ag, and 92% and 85.1% for VWF:GPIbM/VWF:Ag, whereas a lowered cut-off of < 0.60 resulted in reduced sensitivity with increased specificity for all assays. Conclusion VWD classification based on FVIII:C, VWF:Ag and VWF:GPIb-binding activity revealed an overall problem with normal VWF:GPIb-binding activity/VWF:Ag within type 2, especially type 2A/IIE. Although all assays were practically identical, BC-VWF:RCo had higher %CV compared with both new assays but comparable lower limit of quantification (LLOQ) ~4 IU dL-1 . No clear improved distinction between type 1 and 2 VWD with new assays was seen. BC-VWF: RCo and HemosIL® are ristocetin dependent, whereas INNOVANCE® does not rely upon ristocetin and is not influenced by VWF polymorphisms increasing VWF:GPIb-binding activity levels. INNOVANCE® seems to be the best choice as a first-line VWF:GPIb-binding activity assay, providing the best balance between sensitivity and specificity for type 2 VWD.
- MeSH
- biologické markery krev MeSH
- design vybavení MeSH
- hematologické testy přístrojové vybavení metody MeSH
- laboratorní automatizace MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- průřezové studie MeSH
- reprodukovatelnost výsledků MeSH
- trombocytový glykoproteinový komplex Ib-IX metabolismus MeSH
- vazba proteinů MeSH
- von Willebrandova nemoc krev klasifikace diagnóza MeSH
- von Willebrandův faktor metabolismus MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- srovnávací studie MeSH
- Geografické názvy
- Belgie MeSH
- Česká republika MeSH
Objectives: In a separate document, we have provided specific guidance on performing individual pharmacokinetic (PK) studies using limited samples in persons with hemophilia with the goal to optimize prophylaxis with clotting factor concentrates. This paper, intended for clinicians, aims to describe how to interpret and apply PK properties obtained in persons with hemophilia. Methods: The members of the Working Party on population PK (PopPK) of the ISTH SSC Subcommittee on Factor VIII and IX and rare bleeding disorders, together with additional hemophilia and PK experts, completed a survey and ranking exercise whereby key areas of interest in the field were identified. The group had regular web conferences to refine the manuscript's scope and structure, taking into account comments from the external feedback to the earlier document. Results: Many clinical decisions in hemophilia are based on some form of explicit or implicit PK assessment. Individual patient PK profiles can be analyzed through traditional or PopPK methods, with the latter providing the advantage of fewer samples needing to be collected on any prophylaxis regimen, and without the need the for a washout period. The most useful presentation of PK results for clinical decision making are a curve of the factor activity level over time, the time to achieve a certain activity level, or related parameters like half-life or exposure (AUC). Software platforms have been developed to deliver this information to clinicians at the point of care. Key characteristics of studies measuring average PK parameters were reviewed, outlining what makes a credible head-to-head comparison among different concentrates. Large data collections of PK and treatment outcomes currently ongoing will advance care in the future. Conclusions: Traditionally used to compare different concentrates, PK can support tailoring of hemophilia treatment by individual profiling, which is greatly simplified by adopting a PopPK/Bayesian method and limited sampling protocol.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH