BACKGROUND: Distal embolization (DE) is a common complication of endovascular treatment (EVT). We investigated the association of radiological thrombus characteristics and treatment details with DE. METHODS: Patients with thin-slice (≤2.5 mm) baseline noncontrast computed tomography and computed tomography angiography from the ESCAPE-NA1 trial (Efficacy and Safety of Nerinetide for the Treatment of Acute Ischemic Stroke) were included. Thrombus annotation was performed manually on coregistered scans by experienced readers. We assessed thrombus location, distance from internal carotid artery terminus, length, perviousness, absolute attenuation, and hyperdense artery sign. In addition, we evaluated balloon guide catheter use during EVT, first-line EVT approach, the number of thrombectomy passes, and prior intravenous thrombolysis administration. DE was defined as the occurrence of emboli distal to the target artery or in new territories during EVT. The association between thrombus characteristics, treatment details, and DE was evaluated using descriptive statistics and multivariable mixed-effects logistic regression, resulting in adjusted odds ratios (aOR) with 95% CI. Interaction between IVT and radiological thrombus characteristics was assessed by adding interaction terms in separate models. RESULTS: In total, 496 out of 1105 (44.9%) ESCAPE-NA1 patients were included. DE was detected in 251 out of 496 patients (50.6%). Patients with DE had longer thrombi (median, 28.5 [interquartile range, 20.8-42.3] mm versus 24.4 [interquartile range, 17.1-32.4] mm; P<0.01). There were no statistically significant differences in the other thrombus characteristics. Factors associated with DE were thrombus length (aOR, 1.02 [95% CI, 1.01-1.04]), balloon guide catheter use (aOR, 0.49 [95% CI, 0.29-0.85]), and number of passes (aOR, 1.24 [95% CI, 1.04-1.47]). In patients with hyperdense artery sign, IVT was associated with reduced odds of DE (aOR, 0.55 [95% CI, 0.31-0.97]), P for interaction=0.04. CONCLUSIONS: DE was associated with longer thrombi, no balloon guide catheter use, and more EVT passes. IVT was associated with a reduced risk of DE in patients with hyperdense artery sign. These findings may support treatment decisions on IVT and EVT approaches.
- MeSH
- cévní mozková příhoda * terapie MeSH
- endovaskulární výkony * škodlivé účinky MeSH
- ischemická cévní mozková příhoda * etiologie MeSH
- ischemie mozku * terapie MeSH
- lidé MeSH
- trombektomie MeSH
- trombolytická terapie metody MeSH
- trombóza * etiologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Infarct lesion volume (ILV) may serve as an imaging biomarker for clinical outcomes in the early post-treatment stage in patients with acute ischemic stroke. The aim of this study was to evaluate the inter- and intra-rater reliability of manual segmentation of ILV on follow-up non-contrast CT (NCCT) scans. METHODS: Fifty patients from the Prove-IT study were randomly selected for this analysis. Three raters manually segmented ILV on 24-h NCCT scans, slice by slice, three times. The reference standard for ILV was generated by the Simultaneous Truth And Performance Level estimation (STAPLE) algorithm. Intra- and inter-rater reliability was evaluated, using metrics of intraclass correlation coefficient (ICC) regarding lesion volume and the Dice similarity coefficient (DSC). RESULTS: Median age of the 50 subjects included was 74.5 years (interquartile range [IQR] 67-80), 54% were women, median baseline National Institutes of Health Stroke Scale was 18 (IQR 11-22), median baseline ASPECTS was 9 (IQR 6-10). The mean reference standard ILV was 92.5 ml (standard deviation (SD) ± 100.9 ml). The manually segmented ILV ranged from 88.2 ± 91.5 to 135.5 ± 119.9 ml (means referring to the variation between readers, SD within readers). Inter-rater ICC was 0.83 (95%CI: 0.76-0.88); intra-rater ICC ranged from 0.85 (95%CI: 0.72-0.92) to 0.95 (95%CI: 0.91-0.97). The mean DSC among the three readers ranged from 65.5 ± 22.9 to 76.4 ± 17.1% and the mean overall DSC was 72.8 ± 23.0%. CONCLUSION: Manual ILV measurements on follow-up CT scans are reliable to measure the radiological outcome despite some variability.
- MeSH
- algoritmy MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- ischemická cévní mozková příhoda * MeSH
- lidé MeSH
- počítačová rentgenová tomografie metody MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: CT angiography (CTA) is the imaging standard for large vessel occlusion (LVO) detection in patients with acute ischemic stroke. StrokeSENS LVO is an automated tool that utilizes a machine learning algorithm to identify anterior large vessel occlusions (LVO) on CTA. The aim of this study was to test the algorithm's performance in LVO detection in an independent dataset. METHODS: A total of 400 studies (217 LVO, 183 other/no occlusion) read by expert consensus were used for retrospective analysis. The LVO was defined as intracranial internal carotid artery (ICA) occlusion and M1 middle cerebral artery (MCA) occlusion. Software performance in detecting anterior LVO was evaluated using receiver operator characteristics (ROC) analysis, reporting area under the curve (AUC), sensitivity, and specificity. Subgroup analyses were performed to evaluate if performance in detecting LVO differed by subgroups, namely M1 MCA and ICA occlusion sites, and in data stratified by patient age, sex, and CTA acquisition characteristics (slice thickness, kilovoltage tube peak, and scanner manufacturer). RESULTS: AUC, sensitivity, and specificity overall were as follows: 0.939, 0.894, and 0.874, respectively, in the full cohort; 0.927, 0.857, and 0.874, respectively, in the ICA occlusion cohort; 0.945, 0.914, and 0.874, respectively, in the M1 MCA occlusion cohort. Performance did not differ significantly by patient age, sex, or CTA acquisition characteristics. CONCLUSION: The StrokeSENS LVO machine learning algorithm detects anterior LVO with high accuracy from a range of scans in a large dataset.
- MeSH
- arteriální okluzní nemoci * MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- CT angiografie metody MeSH
- infarkt arteria cerebri media diagnostické zobrazování MeSH
- ischemická cévní mozková příhoda * MeSH
- ischemie mozku * MeSH
- lidé MeSH
- retrospektivní studie MeSH
- software MeSH
- strojové učení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: We aimed to explore the preference of stroke physicians to treat patients with primary medium vessel occlusion (MeVO) stroke with immediate endovascular treatment (EVT) in an international cross-sectional survey, as there is no clear guideline recommendation for EVT in these patients. METHODS: In the survey MeVO-Finding Rationales and Objectifying New Targets for IntervEntional Revascularization in Stroke (MeVO-FRONTIERS), participants were shown four cases of primary MeVOs (six scenarios per case) and asked whether they would treat those patients with EVT. Multivariable logistic regression with clustering by respondent was performed to assess factors influencing the decision to treat. Dominance analysis was performed to assess the influence of factors within the scenarios on decision making. RESULTS: Overall, 366 participants (56 women; 15%) from 44 countries provided 8784 answers to 24 scenarios. Most physicians (59.2%) would treat patients immediately with EVT. Younger patient age (incidence rate ratio (IRR) 1.24, 99% CI 1.19 to 1.30), higher National Institutes of Health Stroke Scale (NIHSS) score (IRR 1.69, 99% CI 1.57 to 1.82), and small core volume (IRR 1.35, 99% CI 1.24 to 1.46) were positively associated with the decision to treat with EVT. Interventionalists (IRR 1.26, 99% CI 1.01 to 1.56) were more likely to treat patients with MeVO immediately with EVT. In the dominance analysis, factors influencing the decision in favor of EVT were (in order of importance): baseline NIHSS, core volume, alteplase use, patients' age, and occlusion site. CONCLUSIONS: Most physicians in this survey were interventionalists and would treat patients with MeVO stroke immediately with EVT. This finding supports the need for robust clinical evidence.
BACKGROUND: Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. METHODS: Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b-3 per attempt. The secondary outcome was successful reperfusion eTICI 2b-3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. RESULTS: Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24-3.40 and OR 1.92; 95% CI: 1.16-3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07-2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47-5.35 and OR 2.05; 95% CI: 1.09-3.84, respectively) was associated with first-pass eTICI 2b-3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b-3 reperfusion (OR 1.95; 95% CI: 1.10-3.46). CONCLUSION: The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.