INTRODUCTION: Epilepsy surgery is the only curative treatment for patients with drug-resistant focal epilepsy. Stereoelectroencephalography (SEEG) is the gold standard to delineate the seizure-onset zone (SOZ). However, up to 40% of patients are subsequently not operated as no focal non-eloquent SOZ can be identified. The 5-SENSE Score is a 5-point score to predict whether a focal SOZ is likely to be identified by SEEG. This study aims to validate the 5-SENSE Score, improve score performance by incorporating auxiliary diagnostic methods and evaluate its concordance with expert decisions. METHODS AND ANALYSIS: Non-interventional, observational, multicentre, prospective study including 200 patients with drug-resistant epilepsy aged ≥15 years undergoing SEEG for identification of a focal SOZ and 200 controls at 22 epilepsy surgery centres worldwide. The primary objective is to assess the diagnostic accuracy and generalisability of the 5-SENSE in predicting focality in SEEG in a prospective cohort. Secondary objectives are to optimise score performance by incorporating auxiliary diagnostic methods and to analyse concordance of the 5-SENSE Score with the expert decisions made in the multidisciplinary team discussion. ETHICS AND DISSEMINATION: Prospective multicentre validation of the 5-SENSE score may lead to its implementation into clinical practice to assist clinicians in the difficult decision of whether to proceed with implantation. This study will be conducted in accordance with the Tri-Council Policy Statement: Ethical Conduct for Research Involving Humans (2014). We plan to publish the study results in a peer-reviewed full-length original article and present its findings at scientific conferences. TRIAL REGISTRATION NUMBER: NCT06138808.
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: This study was undertaken to develop a standardized grading system based on expert consensus for evaluating the level of confidence in the localization of the epileptogenic zone (EZ) as reported in published studies, to harmonize and facilitate systematic reviews in the field of epilepsy surgery. METHODS: We conducted a Delphi study involving 22 experts from 18 countries, who were asked to rate their level of confidence in the localization of the EZ for various theoretical clinical scenarios, using different scales. Information provided in these scenarios included one or several of the following data: magnetic resonance imaging (MRI) findings, invasive electroencephalography summary, and postoperative seizure outcome. RESULTS: The first explorative phase showed an overall interrater agreement of .347, pointing to large heterogeneity among experts' assessments, with only 17% of the 42 proposed scenarios associated with a substantial level of agreement. A majority showed preferences for the simpler scale and single-item scenarios. The successive Delphi voting phases resulted in a majority consensus across experts, with more than two thirds of respondents agreeing on the rating of each of the tested single-item scenarios. High or very high levels of confidence were ascribed to patients with either an Engel class I or class IA postoperative seizure outcome, a well-delineated EZ according to all available invasive EEG (iEEG) data, or a well-delineated focal epileptogenic lesion on MRI. MRI signs of hippocampal sclerosis or atrophy were associated with a moderate level of confidence, whereas a low level was ascribed to other MRI findings, a poorly delineated EZ according to iEEG data, or an Engel class II-IV postoperative seizure outcome. SIGNIFICANCE: The proposed grading system, based on an expert consensus, provides a simple framework to rate the level of confidence in the EZ reported in published studies in a structured and harmonized way, offering an opportunity to facilitate and increase the quality of systematic reviews and guidelines in the field of epilepsy surgery.
The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) and focal-to-bilateral tonic-clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
- MeSH
- ambulantní monitorování přístrojové vybavení metody normy MeSH
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- nositelná elektronika * normy MeSH
- předškolní dítě MeSH
- senioři MeSH
- záchvaty diagnóza patofyziologie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- předškolní dítě MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- směrnice pro lékařskou praxi MeSH
The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy, on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) and focal-to-bilateral tonic-clonic seizures (FBTCS) and recommend use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found moderate level of evidence for seizure types without GTCs or FBTCs. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
- MeSH
- epilepsie diagnóza MeSH
- konsensuální konference jako téma MeSH
- lidé MeSH
- neurofyziologický monitoring přístrojové vybavení metody normy MeSH
- nositelná elektronika normy MeSH
- směrnice pro lékařskou praxi jako téma * MeSH
- společnosti lékařské MeSH
- záchvaty diagnóza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
OBJECTIVE: Resective surgery is effective in treating drug-resistant focal epilepsy, but it remains unclear whether improved diagnostics influence postsurgical outcomes. Here, we compared practice and outcomes over 2 periods 15 years apart. METHODS: Sixteen European centers retrospectively identified 2 cohorts of children and adults who underwent epilepsy surgery in the period of 1997 to 1998 (n = 562) or 2012 to 2013 (n = 736). Data collected included patient (sex, age) and disease (duration, localization and diagnosis) characteristics, type of surgery, histopathology, Engel postsurgical outcome, and complications, as well as imaging and electrophysiologic tests performed for each case. Postsurgical outcome predictors were included in a multivariate logistic regression to assess the strength of date of surgery as an independent predictor. RESULTS: Over time, the number of operated cases per center increased from a median of 31 to 50 per 2-year period (p = 0.02). Mean disease duration at surgery decreased by 5.2 years (p < 0.001). Overall seizure freedom (Engel class 1) increased from 66.7% to 70.9% (adjusted p = 0.04), despite an increase in complex surgeries (extratemporal and/or MRI negative). Surgeries performed during the later period were 1.34 times (adjusted odds ratio; 95% confidence interval 1.02-1.77) more likely to yield a favorable outcome (Engel class I) than earlier surgeries, and improvement was more marked in extratemporal and MRI-negative temporal epilepsy. The rate of persistent neurologic complications remained stable (4.6%-5.3%, p = 0.7). CONCLUSION: Improvements in European epilepsy surgery over time are modest but significant, including higher surgical volume, shorter disease duration, and improved postsurgical seizure outcomes. Early referral for evaluation is required to continue on this encouraging trend.
- MeSH
- časové faktory MeSH
- dítě MeSH
- dospělí MeSH
- elektrofyziologické jevy MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- neurochirurgické výkony statistika a číselné údaje MeSH
- neurozobrazování MeSH
- pooperační komplikace epidemiologie MeSH
- předškolní dítě MeSH
- refrakterní epilepsie epidemiologie chirurgie MeSH
- retrospektivní studie MeSH
- výsledek terapie * MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
We explored the current practice with respect to the neuropsychological assessment of surgical epilepsy patients in European epilepsy centers, with the aim of harmonizing and establishing common standards. Twenty-six epilepsy centers and members of "E-PILEPSY" (a European pilot network of reference centers in refractory epilepsy and epilepsy surgery), were asked to report the status of neuropsychological assessment in adults and children via two different surveys. There was a consensus among these centers regarding the role of neuropsychology in the presurgical workup. Strong agreement was found on indications (localization, epileptic dysfunctions, adverse drugs effects, and postoperative monitoring) and the domains to be evaluated (memory, attention, executive functions, language, visuospatial skills, intelligence, depression, anxiety, and quality of life). Although 186 different tests are in use throughout these European centers, a core group of tests reflecting a moderate level of agreement could be discerned. Variability exists with regard to indications, protocols, and paradigms for the assessment of hemispheric language dominance. For the tests in use, little published evidence of clinical validity in epilepsy was provided. Participants in the survey reported a need for improvement concerning the validity of the tests, tools for the assessment of everyday functioning and accelerated forgetting, national norms, and test co-normalization. Based on the present survey, we documented a consensus regarding the indications and principles of neuropsychological testing. Despite the variety of tests in use, the survey indicated that there may be a core set of tests chosen based on experience, as well as on published evidence. By combining these findings with the results of an ongoing systematic literature review, we aim for a battery that can be recommended for the use across epilepsy surgical centers in Europe.
- MeSH
- epilepsie komplikace epidemiologie chirurgie MeSH
- kognitivní poruchy * diagnóza epidemiologie etiologie MeSH
- lidé MeSH
- mezinárodní spolupráce MeSH
- neuropsychologické testy normy MeSH
- neurozobrazování MeSH
- průzkumy zdravotní péče statistika a číselné údaje MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa epidemiologie MeSH
PURPOSE: The European Union-funded E-PILEPSY network aims to improve awareness of, and accessibility to, epilepsy surgery across Europe. In this study we assessed current clinical practices in epilepsy monitoring units (EMUs) in the participating centers. METHOD: A 60-item web-based survey was distributed to 25 centers (27 EMUs) of the E-PILEPSY network across 22 European countries. The questionnaire was designed to evaluate the characteristics of EMUs, including organizational aspects, admission, and observation of patients, procedures performed, safety issues, cost, and reimbursement. RESULTS: Complete responses were received from all (100%) EMUs surveyed. Continuous observation of patients was performed in 22 (81%) EMUs during regular working hours, and in 17 EMUs (63%) outside of regular working hours. Fifteen (56%) EMUs requested a signed informed consent before admission. All EMUs performed tapering/withdrawal of antiepileptic drugs, 14 (52%) prior to admission to an EMU. Specific protocols on antiepileptic drugs (AED) tapering were available in four (15%) EMUs. Standardized Operating Procedures (SOP) for the treatment of seizure clusters and status epilepticus were available in 16 (59%). Safety measures implemented by EMUs were: alarm seizure buttons in 21 (78%), restricted patient's ambulation in 19 (70%), guard rails in 16 (59%), and specially designated bathrooms in 7 (26%). Average costs for one inpatient day in EMU ranged between 100 and 2200 Euros. CONCLUSION: This study shows a considerable diversity in the organization and practice patterns across European epilepsy monitoring units. The collected data may contribute to the development and implementation of evidence-based recommended practices in LTM services across Europe.
- MeSH
- dítě MeSH
- dospělí MeSH
- elektroencefalografie statistika a číselné údaje MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- monitorování fyziologických funkcí statistika a číselné údaje MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- refrakterní epilepsie diagnóza MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
OBJECTIVE: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. METHODS: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. RESULTS: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. SIGNIFICANCE: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.
- MeSH
- epilepsie diagnostické zobrazování patofyziologie chirurgie MeSH
- lidé MeSH
- mezinárodní spolupráce MeSH
- neurozobrazování * metody statistika a číselné údaje trendy MeSH
- počítačové zpracování obrazu MeSH
- průzkumy a dotazníky MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa epidemiologie MeSH
Our inability to adequately treat many patients with refractory epilepsy caused by focal cortical dysplasia (FCD), surgical inaccessibility and failures are significant clinical drawbacks. The targeting of physiologic features of epileptogenesis in FCD and colocalizing functionality has enhanced completeness of surgical resection, the main determinant of outcome. Electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) and magnetoencephalography are helpful in guiding electrode implantation and surgical treatment, and high-frequency oscillations help defining the extent of the epileptogenic dysplasia. Ultra high-field MRI has a role in understanding the laminar organization of the cortex, and fluorodeoxyglucose-positron emission tomography (FDG-PET) is highly sensitive for detecting FCD in MRI-negative cases. Multimodal imaging is clinically valuable, either by improving the rate of postoperative seizure freedom or by reducing postoperative deficits. However, there is no level 1 evidence that it improves outcomes. Proof for a specific effect of antiepileptic drugs (AEDs) in FCD is lacking. Pathogenic mutations recently described in mammalian target of rapamycin (mTOR) genes in FCD have yielded important insights into novel treatment options with mTOR inhibitors, which might represent an example of personalized treatment of epilepsy based on the known mechanisms of disease. The ketogenic diet (KD) has been demonstrated to be particularly effective in children with epilepsy caused by structural abnormalities, especially FCD. It attenuates epigenetic chromatin modifications, a master regulator for gene expression and functional adaptation of the cell, thereby modifying disease progression. This could imply lasting benefit of dietary manipulation. Neurostimulation techniques have produced variable clinical outcomes in FCD. In widespread dysplasias, vagus nerve stimulation (VNS) has achieved responder rates >50%; however, the efficacy of noninvasive cranial nerve stimulation modalities such as transcutaneous VNS (tVNS) and noninvasive (nVNS) requires further study. Although review of current strategies underscores the serious shortcomings of treatment-resistant cases, initial evidence from novel approaches suggests that future success is possible.
- MeSH
- antikonvulziva terapeutické užití MeSH
- elektroencefalografie metody MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- malformace mozkové kůry diagnóza epidemiologie terapie MeSH
- refrakterní epilepsie diagnóza epidemiologie terapie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
Epilepsy is both a disease of the brain and the mind. Here, we present the second of two papers with extended summaries of selected presentations of the Third International Congress on Epilepsy, Brain and Mind (April 3-5, 2014; Brno, Czech Republic). Humanistic, biologic, and therapeutic aspects of epilepsy, particularly those related to the mind, were discussed. The extended summaries provide current overviews of epilepsy, cognitive impairment, and treatment, including brain functional connectivity and functional organization; juvenile myoclonic epilepsy; cognitive problems in newly diagnosed epilepsy; SUDEP including studies on prevention and involvement of the serotoninergic system; aggression and antiepileptic drugs; body, mind, and brain, including pain, orientation, the "self-location", Gourmand syndrome, and obesity; euphoria, obsessions, and compulsions; and circumstantiality and psychiatric comorbidities.
- MeSH
- agrese psychologie MeSH
- antikonvulziva terapeutické užití MeSH
- bolest diagnóza farmakoterapie psychologie MeSH
- epilepsie diagnóza farmakoterapie psychologie MeSH
- internacionalita * MeSH
- kognitivní poruchy diagnóza farmakoterapie psychologie MeSH
- kompulzivní chování diagnóza farmakoterapie psychologie MeSH
- kongresy jako téma * trendy MeSH
- lidé MeSH
- metafyzické vztahy mezi duší a tělem * MeSH
- mozek patologie patofyziologie MeSH
- myoklonická epilepsie juvenilní diagnóza farmakoterapie psychologie MeSH
- náhlá smrt prevence a kontrola MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Geografické názvy
- Česká republika MeSH