- Klíčová slova
- hygienické stanice,
- MeSH
- COVID-19 * prevence a kontrola MeSH
- epidemie prevence a kontrola MeSH
- identifikační systémy pacientů MeSH
- informační systémy MeSH
- koronavirové infekce prevence a kontrola MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- populární práce MeSH
Závěrečná práce NCONZO
1 svazek : grafy, tabulky ; 30 cm + 1 CD
- MeSH
- akreditace organizace a řízení MeSH
- ambulantní kliniky nemocniční organizace a řízení MeSH
- bezpečnost pacientů MeSH
- chybná zdravotní péče prevence a kontrola MeSH
- identifikační systémy pacientů metody trendy MeSH
- průzkumy a dotazníky MeSH
- zajištění kvality zdravotní péče organizace a řízení MeSH
- Konspekt
- Veřejné zdraví a hygiena
- NLK Publikační typ
- závěrečné práce
Tracking individual animals with small-sized passive integrated transponder tags (PIT tags) has become a popular and widespread method, one which can be used for investigating life history traits, including dispersal patterns of small protected animals such as newts. In this study, we tested the applicability of PIT tag usage for individual marking with the Great crested newt (Triturus cristatus) as a model amphibian species, and to test the detection of the newts in nature using a passive telemetry system. Clove oil was used as an anaesthetic before surgery. We implanted PIT tags under the skin of 140 newts. The survival rate of newts was 98.57%. X-ray images were taken to check the exact positions of the PIT tags. Since approximately 15.71% of the newts were capable of expelling the tag from their bodies, tag loss has to be accounted for in future behavioural studies dealing with newts and other amphibians potentially capable of frequent tag expulsion. Lastly, we detected by passive telemetry 97 individuals out of 100 released into a natural breeding pond. Males had higher activity (13 detected males vs 7 females per hour) than females, thus males could be detected if present with more certainty. The result of the movement behaviour showed that e.g. the male of T. cristatus in a breeding pond can travel up to 20 m in 78 seconds. In summary, this promising method could allow the automatic data collection of marked newts in aquatic as well as in terrestrial biotopes, providing data on their dispersal, diurnal activity and movement behaviour.
- MeSH
- chování zvířat MeSH
- identifikace na rádiové frekvenci - prostředky * MeSH
- rybníky MeSH
- technologie dálkového snímání přístrojové vybavení MeSH
- telemetrie přístrojové vybavení MeSH
- Triturus anatomie a histologie fyziologie chirurgie MeSH
- zvířata MeSH
- Check Tag
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
x
x
- Klíčová slova
- identifikační a třídící karta, třídící metoda START,
- MeSH
- first responder výchova MeSH
- hromadné neštěstí MeSH
- identifikační systémy pacientů metody využití MeSH
- katastrofy MeSH
- odborná způsobilost MeSH
- plánování postupu v případě katastrof MeSH
- průzkumy a dotazníky využití MeSH
- třídění pacientů MeSH
- urgentní zdravotnické služby pracovní síly MeSH
Závěrečná práce NCONZO
1 svazek : grafy, tabulky, ilustrace ; 30 cm + 1 CD-ROM
- Klíčová slova
- technologie RFID, Masarykův onkologický ústav,
- MeSH
- antitumorózní látky MeSH
- bezpečnost pacientů MeSH
- cytostatické látky MeSH
- hygiena práce MeSH
- identifikace na rádiové frekvenci - prostředky MeSH
- nemocniční informační systémy organizace a řízení MeSH
- nemocniční lékárny organizace a řízení MeSH
- příprava léků metody MeSH
- průzkumy a dotazníky MeSH
- Konspekt
- Farmacie. Farmakologie
The strongest and best-documented risk factor for drug hypersensitivity (DH) is the history of a previous reaction. Accidental exposures to drugs may lead to severe or even fatal reactions in sensitized patients. Preventable prescription errors are common. They are often due to inadequate medical history or poor risk assessment of recurrence of drug reaction. Proper documentation is essential information for the doctor to make sound therapeutic decision. The European Network on Drug Allergy and Drug Allergy Interest Group of the European Academy of Allergy and Clinical Immunology have formed a task force and developed a drug allergy passport as well as general guidelines of drug allergy documentation. A drug allergy passport, a drug allergy alert card, a certificate, and a discharge letter after medical evaluation are adequate means to document DH in a patient. They are to be handed to the patient who is advised to carry the documentation at all times especially when away from home. A drug allergy passport should at least contain information on the culprit drug(s) including international nonproprietary name, clinical manifestations including severity, diagnostic measures, potential cross-reactivity, alternative drugs to prescribe, and where more detailed information can be obtained from the issuer. It should be given to patients only after full allergy workup. In the future, electronic prescription systems with alert functions will become more common and should include the same information as in paper-based documentation.
- MeSH
- čipové karty ve zdravotnictví * MeSH
- dokumentace * metody MeSH
- léková alergie diagnóza etiologie prevence a kontrola MeSH
- lidé MeSH
- průzkumy a dotazníky MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
Při léčbě onkologicky nemocných jsou používány látky s rizikem karcinogenity a mutagenity - tzv. cytostatika, která obecně patří k velmi nebezpečným látkám s nízkým terapeutickým indexem, to znamená léčiva s malým rozdílem mezi terapeutickou a toxickou dávkou. Z toho vyplývá, že špatně zvolená dávka může pacienta bezprostředně ohrozit na životě. Jednou z cest, jak minimalizovat možná lidská pochybení, je zajistit maximální kontrolu a zamezit vzniku chyb při přípravě a podání léku. Přesná evidence přípravy a podání cytotoxických léčiv je rovněž vyžadována ze zákona. V Masarykově onkologickém ústavu se od roku 2010 používá v rámci celého procesu přípravy a aplikace chemoterapie tzv. radiofrekvenční identifikace (RFID), která mimo jiné přináší sestrám naprostou jistotu při aplikaci léčiva a okamžitě je upozorní na možné neshody.
- MeSH
- antitumorózní látky * aplikace a dávkování MeSH
- identifikace na rádiové frekvenci - prostředky * metody využití MeSH
- informační systémy v klinické farmacii přístrojové vybavení MeSH
- lidé MeSH
- nemocniční informační systémy MeSH
- nemocniční komunikační systémy MeSH
- příprava léků metody přístrojové vybavení MeSH
- systémy medikace v nemocnici * MeSH
- Check Tag
- lidé MeSH
Praktik
Vydání první 230 stran : ilustrace ; 21 cm
- MeSH
- čipové karty ve zdravotnictví zákonodárství a právo MeSH
- důvěrnost informací zákonodárství a právo MeSH
- identifikace na rádiové frekvenci - prostředky zákonodárství a právo MeSH
- identifikační systémy pacientů zákonodárství a právo MeSH
- občanská práva MeSH
- soukromí zákonodárství a právo MeSH
- Publikační typ
- monografie MeSH
- Geografické názvy
- Česká republika MeSH
- Konspekt
- Ústavní právo. Správní právo
- NLK Obory
- právo, zákonodárství
- technika