AIMS: To present a new method of dynamic Purkinje-metry and to verify it by comparison with a commercially available anterior segment optical coherence tomography CASIA2. PATIENTS AND METHODS: A dynamic Purkinje-meter with a movable fixation target was assembled. A coaxial circular pattern formed by infrared LEDs was projected onto the eye and evoked Purkinje images (1st, 3rd, 4th = P1, P3, P4). The measurement was performed on 29 eyes with an implanted toric IOL (intraocular lens), under mydriatic conditions, with reference to the visual axis. The IOL tilt was calculated from the position of a fixation target at the moment of P3 and P4 superposition. The IOL decentration was determined based on the relative position of P1 during on-axis fixation and of P3 and P4 superposition during off-axis fixation. A custom-developed software was used for distance measurements. Using CASIA2, the IOL position was fully calculated by the device. RESULTS: The mean absolute difference between CASIA2 and Purkinje-meter values was 0.6° ± 0.4° for the tilt magnitude and 10° ± 10° for the tilt direction, and 0.11 mm ± 0.08 mm for the decentration magnitude and 16° ± 14° for the decentration direction. There was no statistically significant difference between the values determined by the two methods for the tilt and decentration direction. The differences were statistically significant for the tilt and decentration magnitude. CONCLUSION: The values of IOL tilt and decentration direction are similar for both devices. The values of IOL tilt and decentration magnitude measured by Purkinje-meter are higher than those from CASIA2, but overall, they correspond to the values presented in other published studies.
- MeSH
- algoritmy MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitrooční čočky * MeSH
- optická koherentní tomografie MeSH
- optické zobrazování * přístrojové vybavení metody MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- srovnávací studie MeSH
- MeSH
- dospělí MeSH
- fluorescence MeSH
- impedanční spektroskopie přístrojové vybavení MeSH
- interproximální technika přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- optické zobrazování metody přístrojové vybavení MeSH
- senioři MeSH
- statistika jako téma MeSH
- zubní kaz diagnostické zobrazování MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- senioři MeSH
- Publikační typ
- srovnávací studie MeSH
- Geografické názvy
- Dánsko MeSH
Because of their obvious advantages, active and passive optoelectronic sensor concepts are being investigated by biomedical research groups worldwide, particularly their camera-based variants. Such methods work noninvasively and contactless, and they provide spatially resolved parameter detection. We present 2 techniques: the active photoplethysmography imaging (PPGI) method for detecting dermal blood perfusion dynamics and the passive infrared thermography imaging (IRTI) method for detecting skin temperature distribution. PPGI is an enhancement of classical pulse oximetry. Approved algorithms from pulse oximetry for the detection of heart rate, heart rate variability, blood pressure-dependent pulse wave velocity, pulse waveform-related stress/pain indicators, respiration rate, respiratory variability, and vasomotional activity can easily be adapted to PPGI. Although the IRTI method primarily records temperature distribution of the observed object, information on respiration rate and respiratory variability can also be derived by analyzing temperature change over time, for example, in the nasal region, or through respiratory movement. Combined with current research areas and novel biomedical engineering applications (eg, telemedicine, tele-emergency, and telemedical diagnostics), PPGI and IRTI may offer new data for diagnostic purposes, including assessment of peripheral arterial and venous oxygen saturation (as well as their differences). Moreover, facial expressions and stress and/or pain-related variables can be derived, for example, during anesthesia, in the recovery room/intensive care unit and during daily activities. The main advantages of both monitoring methods are unobtrusive data acquisition and the possibility to assess vital variables for different body regions. These methods supplement each other to enable long-term monitoring of physiological effects and of effects with special local characteristics. They also offer diagnostic advantages for intensive care patients and for high-risk patients in a homecare/outdoor setting. Selected applications have been validated at our laboratory using optical PPGI and IRTI techniques in a stand-alone or hybrid configuration. Additional research and validation is required before these preliminary results can be introduced for clinical applications.
- MeSH
- ambulantní monitorování přístrojové vybavení metody MeSH
- časové faktory MeSH
- design vybavení MeSH
- fotopletysmografie * přístrojové vybavení MeSH
- hemodynamika * MeSH
- infračervené záření MeSH
- kůže krevní zásobení MeSH
- lidé MeSH
- mechanika dýchání * MeSH
- měniče MeSH
- optické zobrazování * přístrojové vybavení MeSH
- oxymetrie * přístrojové vybavení MeSH
- prediktivní hodnota testů MeSH
- regionální krevní průtok MeSH
- reprodukovatelnost výsledků MeSH
- rychlost toku krve MeSH
- teploměry MeSH
- teplota kůže * MeSH
- termografie * přístrojové vybavení MeSH
- výraz obličeje * MeSH
- zdravotní stav MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Článek mapuje fascinující historické milníky diagnostiky diabetické retinopatie. V souvislosti s jejím objevem pak představuje některé významné postavy oftalmologie a dokumentuje vývoj diagnostických prostředků, konzervativní léčby, ale i laserové a chirurgické terapie tohoto závažného onemocnění.
The article surveys the fascinating historical milestones of the diagnosis of diabetic retinopathy. In the context of the discovery then it represents some of the famous characters of ophthalmology and documents the evolution of diagnostics, conservative treatment, as well as laser and surgical therapy for this serious disease
- MeSH
- diabetická retinopatie * dějiny diagnóza terapie MeSH
- fluorofotometrie MeSH
- fundus oculi MeSH
- laserová terapie metody přístrojové vybavení využití MeSH
- lidé MeSH
- makulární edém dějiny diagnóza patofyziologie MeSH
- optická koherentní tomografie metody přístrojové vybavení MeSH
- optické zobrazování metody přístrojové vybavení MeSH
- vaskulární endoteliální růstové faktory MeSH
- vitrektomie metody MeSH
- Check Tag
- lidé MeSH