ECG lead comparison
Dotaz
Zobrazit nápovědu
Inverse ECG imaging methods typically require 32-250 leads to create body surface potential maps (BSPM), limiting their routine clinical use. This study evaluated the accuracy of PaceView inverse ECG method to localize the left or right ventricular (LV and RV, respectively) pacing leads using either a 99-lead BSPM or the 12-lead ECG. A 99-lead BSPM was recorded in patients with cardiac resynchronization therapy (CRT) during sinus rhythm and sequential LV/RV pacing. The non-contrast CT was performed to localize precisely both ECG electrodes and CRT leads. From a BSPM, nine signals were selected to obtain the 12-lead ECG. Both BSPM and 12-lead ECG were used to localize the RV and LV lead, and the localization error was calculated. Consecutive patients with dilated cardiomyopathy, previously implanted with a CRT device, were enrolled (n = 19). The localization error for the RV/LV lead was 9.0 [IQR 4.8-13.6] / 7.7 [IQR 0.0-10.3] mm using the 12-lead ECG and 9.1 [IQR 5.4-15.7] / 9.8 [IQR 8.6-13.1] mm for the BSPM. Thus, the noninvasive lead localization using the 12-lead ECG was accurate enough and comparable to 99-lead BSPM, potentially increasing the capability of 12-lead ECG for the optimization of the LV/RV pacing sites during CRT implant or for the most favorable programming.
- MeSH
- elektrokardiografie metody MeSH
- infarkt myokardu diagnóza MeSH
- Publikační typ
- srovnávací studie MeSH
- MeSH
- elektrokardiografie metody MeSH
- infarkt myokardu diagnóza MeSH
- Publikační typ
- srovnávací studie MeSH
In this work we present a comparative study, testing selected methods for clustering and classification of holter electrocardiogram (ECG). More specifically we focus on the task of discriminating between normal 'N' beats and premature ventricular 'V' beats Some of the tested methods represent the state of the art in pattern analysis, while others are novel algorithms developed by us. All the algorithms were tested on the same datasets, namely the MIT-BIH and the AHA databases. The results for all the employed methods are compared and evaluated using the measures of sensitivity and specificity.
- MeSH
- algoritmy MeSH
- elektrokardiografie MeSH
- financování organizované MeSH
- lidé MeSH
- nemoci srdce klasifikace patofyziologie MeSH
- počítačové zpracování signálu MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- srovnávací studie MeSH
- MeSH
- benzofurany MeSH
- biomedicínský výzkum MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- senioři MeSH
- srdeční frekvence MeSH
- thyreotropin krev MeSH
- thyroxin metabolismus MeSH
- trijodthyronin krev MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- senioři MeSH
- ženské pohlaví MeSH
- MeSH
- dýchání MeSH
- elektroencefalografie MeSH
- elektrokardiografie MeSH
- lidé MeSH
- pletysmografie MeSH
- vazomotorický systém inervace MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- srovnávací studie MeSH