OBJECTIVES: To investigate 4-year, post-transcatheter aortic valve implantation (TAVI) survival and predictors of survival by sex, in a real-world cohort that underwent transfemoral TAVI with SAPIEN 3 transcatheter heart valve. BACKGROUND: Previous TAVI investigations of first-generation devices demonstrated an early- to mid-term survival advantage in women compared with men. METHODS: SOURCE 3 (SAPIEN 3 Aortic Bioprosthesis European Outcome) is a post-approval, multicentre, observational registry. Patients (N = 1,694, 49.2% women, age 81.7 ± 6.7 years) with severe aortic stenosis and high surgical risk (logistic EuroSCORE 17.8%) underwent TAVI between 2014 and 2015. Kaplan-Meier event estimates were used to determine mortality by sex. Predictors of overall mortality were identified using a cox multivariate proportional hazard model. RESULTS: At 4 years, women had lower all-cause mortality than men (36.0 vs 39.7%; p = .0911; HR: 0.87 [95% CI: 0.75-1.02]). No difference was observed for cardiac mortality between women 24.2% and men 24.7% (p = .76; HR: 0.97 [95% CI: 0.79-1.19]). When adjusted for baseline characteristics (age, height, weight, NYHA functional class, renal insufficiency, EuroScore, and tricuspid regurgitation), sex had no impact on mortality. CONCLUSIONS: In this large, real-world cohort, all-cause mortality trended lower in women than men at 4 years post TAVI; however, several baseline factors, but not sex, were predictors of mortality. No difference between sexes was observed for cardiovascular mortality.
- MeSH
- Aortic Valve diagnostic imaging surgery MeSH
- Aortic Valve Stenosis * diagnostic imaging surgery MeSH
- Humans MeSH
- Registries MeSH
- Risk Factors MeSH
- Heart Valve Prosthesis * MeSH
- Transcatheter Aortic Valve Replacement * adverse effects MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
BACKGROUND: Transcatheter aortic valve implantation via the transfemoral route (TF-TAVI) is commonly performed as a treatment for severe aortic stenosis (AS) in patients at high surgical risk. Pre-deployment balloon aortic valvuloplasty (BAV) has generally been considered an essential step for preparing the valve landing zone for receipt of the prosthesis. However, there is little evidence supporting the clinical value of BAV, while several associated complications have been documented. This has provoked several groups to evaluate the feasibility and safety of omitting BAV form the TF-TAVI procedure (direct TF-TAVI), with encouraging results. However, studies comparing the clinical outcomes of direct TF-TAVI to standard TF-TAVI are lacking. METHODS: EASE-IT TF is a prospective, observational, two-armed, multicentre registry designed to gather data on procedural aspects, adverse events and survival rates associated with direct TF-TAVI using the Edwards SAPIEN 3 balloon-expandable prosthesis. DISCUSSION: EASE-IT-TF data will be analysed firstly to determine the risks and benefits associated with direct TF-TAVI vs. standard TF-TAVI, and secondly to identify associations between patient variables and specific outcomes. This may assist identification of patients who stand to benefit from direct TF-TAVI, therefore contributing to clinical reductions in TF-TAVI-associated morbidity and mortality rates in high-risk AS patients. TRIAL REGISTRATIONS: Clinictrials.gov: NCT02760771.
- MeSH
- Aortic Valve surgery MeSH
- Aortic Valve Stenosis diagnosis surgery MeSH
- Femoral Artery MeSH
- Time Factors MeSH
- Surgery, Computer-Assisted methods MeSH
- Equipment Design MeSH
- Fluoroscopy MeSH
- Humans MeSH
- Follow-Up Studies MeSH
- Prospective Studies MeSH
- Prosthesis Design MeSH
- Registries * MeSH
- Aged MeSH
- Cardiac Catheterization methods MeSH
- Severity of Illness Index MeSH
- Transcatheter Aortic Valve Replacement instrumentation MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Controlled Clinical Trial MeSH
- Multicenter Study MeSH
BACKGROUND: Current trials and registries of transcatheter valve implantation (TAVI) mostly include patients older than 75 years. Little is known about younger patients who undergo this treatment. We investigated comorbidities among patients < 75 years old who underwent TAVI in the SAPIEN 3™ European post-approval SOURCE 3 Registry, and analysed outcomes at 30 days and 1 year. METHODS AND RESULTS: Three age groups of patients were analysed for outcomes and characteristics: < 75 (n = 235), 75-80 (n = 391) and ≥ 80 years (n = 1320). Overall, the mean age was 81.6 ± 6.7 years; transfemoral access was used in 87.1% of patients treated with SAPIEN 3 transcatheter heart valves. The mean logistic EuroSCORE increased according to age group (12.6%, 17.3% and 19.7%, respectively, p < 0.001). Younger patients had a higher incidence of comorbidities, particularly those not included in surgical risk score assessment tools, e.g., severe liver disease, previous radiation therapy, and porcelain aorta. Mortality rates were similar between age groups at 30 days (1.7%, 2.0% and 2.3%, respectively, p = 0.79) and 1 year (14.2%, 9.3% and 13.3%, respectively, p = 0.08). However, sudden cardiac death rates were higher in the < 75 years age group compared with the ≥ 85 years age group (20.7% vs. 4.8%, p = 0.010). CONCLUSIONS: In current TAVI practice, patients younger than 75 years are a minority (12%). Despite younger age and lower surgical risk scores, this cohort was characterized by comorbidities not accounted for by traditional surgical risk scores. More data are needed for this age group to guide the appropriate decision between surgery and TAVI. CLINICALTRIAL. GOV NUMBER: NCT02698956.
- MeSH
- Aortic Valve surgery MeSH
- Aortic Valve Stenosis mortality surgery MeSH
- Risk Assessment methods MeSH
- Incidence MeSH
- Humans MeSH
- Survival Rate trends MeSH
- Postoperative Complications epidemiology MeSH
- Cause of Death trends MeSH
- Registries * MeSH
- Risk Factors MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Transcatheter Aortic Valve Replacement methods MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Observational Study MeSH
- Geographicals
- Europe MeSH
BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) for treating aortic stenosis (AS) has increased exponentially in recent years. Despite the availability of clinical practice guidelines for the management of valvular heart disease, disparities in quality of care (QoC) for TAVI patients remain widespread across Europe. Tailored QoC measures will help to reduce resource utilization and improve patient outcomes without compromising patient safety. Using a clear set of QoC measures, the BENCHMARK registry aims to document the progress that can be achieved if such tailored QoC measures are implemented. METHODS: The BENCHMARK registry (BENCHMARK) is a non-interventional, multicenter registry in patients with severe symptomatic AS undergoing TAVI with a 1- and 12-months follow-up. BENCHMARK will be conducted at 30 centers across Europe and will enroll a total of 2400 consecutive TAVI patients. Patients suffering from severe symptomatic AS who undergo TAVI with a balloon-expandable transcatheter aortic valve will be included. The registry will comprise four phases: (1) a retrospective baseline evaluation phase; (2) an education phase; (3) an implementation phase; and (4) a prospective effect documentation phase (prospective phase). The registry's primary objectives are to reduce the length of hospital stay and accelerate the post-procedural patient recovery pathway, but without compromising safety. The study started in April 2021 and has an estimated completion date of May 2023. DISCUSSION: BENCHMARK will establish QoC measures to reduce resource utilization, intensive care unit bed occupancy, and overall length of hospitalization with uncompromised patient safety post-TAVI (ClinicalTrials.gov Identifier: NCT04579445).
- MeSH
- Aortic Valve surgery MeSH
- Aortic Valve Stenosis * surgery MeSH
- Benchmarking MeSH
- Time Factors MeSH
- Humans MeSH
- Prospective Studies MeSH
- Registries MeSH
- Retrospective Studies MeSH
- Transcatheter Aortic Valve Replacement * adverse effects MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Geographicals
- Europe MeSH
BACKGROUND: Elderly patients with aortic stenosis (AS) not only have a reduced life expectancy but also a reduced quality of life (QoL). The benefits of an AS intervention may be considered a balance between a good QoL and a reasonably extended life. However, the different questionnaires being used to determine the QoL were generally not developed for the specific situation of patients with AS and come with strengths and considerable weaknesses. The objective of this article was to provide an overview of the available QoL instruments in AS research, describe their strengths and weaknesses, and provide our assessment of the utility of the available scoring instruments for QoL measurements in AS. SUMMARY: We identified and reviewed the following instruments that are used in AS research: Short Form Health Survey (SF-36/SF-12), EuroQol-5D (EQ-5D), the Illness Intrusiveness Rating Scale (IIRS), the HeartQoL, the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Minnesota Living with Heart Failure Questionnaire (MLHF), the MacNew Questionnaire, and the Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ). KEY MESSAGES: There is no standardized assessment of QoL in patients with AS. Many different questionnaires are being used, but they are rarely specific for AS. There is a need for AS-specific research into the QoL of patients as life prolongation may compete for an improved QoL in this elderly patient group.
- MeSH
- Aortic Valve Stenosis * MeSH
- Quality of Life MeSH
- Humans MeSH
- Surveys and Questionnaires MeSH
- Aged MeSH
- Heart Failure * MeSH
- Check Tag
- Humans MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Review MeSH
The transcatheter aortic valve implantation (TAVI) treatment pathway is complex, leading to procedure-related delays. Dedicated TAVI coordinators can improve pathway efficiency. COORDINATE was a pilot observational prospective registry at three German centers that enrolled consecutive elective patients with severe aortic stenosis undergoing TAVI to investigate the impact a TAVI coordinator program. Pathway parameters and clinical outcomes were assessed before (control group) and after TAVI coordinator program implementation (intervention phase). The number of repeated diagnostics remained unchanged after implementation. Patients with separate hospitalizations for screening and TAVI had long delays, which increased after implementation (65 days pre- vs. 103 days post-implementation); hospitalizations combining these were more efficient. The mean time between TAVI and hospital discharge remained constant. Nurse (p = 0.001) and medical technician (p = 0.008) working hours decreased. Patient satisfaction increased, and more consistent/intensive contact between patients and staff was reported. TAVI coordinators provided more post-TAVI support, including discharge management. No adverse effects on post-procedure or 30-day outcomes were seen. This pilot suggests that TAVI coordinator programs may improve aspects of the TAVI pathway, including post-TAVI care and patient satisfaction, without compromising safety. These findings will be further investigated in the BENCHMARK registry.
- Publication type
- Journal Article MeSH
Background: Patients with severe aortic stenosis (AS) have a reduced life expectancy and quality of life (QoL), owing to advanced age and the presence of multiple comorbidities. Currently, there is no AS-specific QoL measurement tool, which prevents an accurate assessment of how this chronic condition and its treatment affect patients. The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) was developed in order to address this deficiency. Methods: The present trial protocol was designed to enable validation of the TASQ, which has been produced in five languages (English, French, German, Italian and Spanish) to increase usability. Patients with severe AS who are undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI) will be asked to complete the TASQ and, for comparative purposes, the Kansas City Cardiomyopathy Questionnaire and the general health-related QoL Short Form-12 questionnaire. The questionnaires will be completed prior to the intervention, at discharge, as well as at 30 days and 3 months follow-up. A total of 290 patients will be recruited across one Canadian and nine European centres. Overall, the protocol validation aims to include 120 patients undergoing transfemoral TAVI (TF-TAVI), 120 undergoing SAVR and up to 50 being treated medically. The primary objective of the registry is to validate the TASQ in five different languages. The secondary objective is to assess the utility of the TASQ for assessing differences in QoL outcome between patients undergoing TF-TAVI, SAVR or medical management for their AS. Discussion: Validation and roll-out of the TASQ will enable clinicians to capture an accurate assessment of how AS and its management affects the QoL of patients and will help them to determine the most appropriate treatment strategy for individual patients. Trial registration number: NCT03186339.
- Publication type
- Journal Article MeSH
BACKGROUND: The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) is a validated instrument for assessing quality of life (QoL) in patients with severe aortic stenosis (AS). In this study, we evaluated health status outcomes, based on the TASQ, in patients with severe AS undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). METHODS: The TASQ registry was a prospective observational registry. Patients with severe AS from nine centres in Europe and one in Canada underwent either SAVR or transfemoral TAVR. Patients completed the TASQ, Kansas City Cardiomyopathy Questionnaire and Short Form-12 V.2 prior to the intervention, predischarge, and at 30-day and 3-month follow-ups. Primary end point was the TASQ score. RESULTS: In both the TAVR (n=137) and SAVR (n=137) cohorts, significant increases were observed in all three scores. The overall TASQ score improved as did all but one of the individual domains at 3 months after the intervention (p<0.001). TASQ health expectations were the only domain which worsened (p<0.001). Across TASQ subscores, significant changes were evident from the time of discharge in the TAVR and 30-day follow-up in the SAVR cohort. In a categorical analysis of the TASQ, 39.7% of the TAVR group and 35.0% of the SAVR group had a substantially improved health status at 3 months compared with baseline. CONCLUSIONS: The TASQ captured changes in QoL among patients with severe AS who were treated with TAVR or SAVR. QoL improved substantially after either intervention, as indicated by changes in the TASQ overall score at 3 months. TRIAL REGISTRATION NUMBER: NCT03186339.
- MeSH
- Aortic Valve surgery MeSH
- Aortic Valve Stenosis epidemiology psychology surgery MeSH
- Quality of Life * MeSH
- Humans MeSH
- Morbidity trends MeSH
- Follow-Up Studies MeSH
- Postoperative Period MeSH
- Prospective Studies MeSH
- Surveys and Questionnaires * MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Transcatheter Aortic Valve Replacement psychology MeSH
- Health Status * MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Observational Study MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Europe MeSH
- Canada MeSH
AIMS: There is no quality of life tool specifically developed for patients with severe aortic stenosis (AS) to assess how this chronic condition and its treatment affect patients. The Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ) has been developed to overcome this gap. The results of the validation of the TASQ in patients undergoing treatment for severe AS are presented. METHODS AND RESULTS: Prospective study at 10 centres in Europe and Canada, which enrolled 274 patients with severe symptomatic AS undergoing surgical or transcatheter aortic valve replacement. Mean TASQ score at baseline was 71.2 points and increased to 88.9 three months after aortic valve implantation (P < 0.001). Increases were seen for the emotional impact (32.0 to 39.0; P < 0.001), physical limitations (14.8 to 22.0; P < 0.001), and physical symptoms (8.5 vs. 11.0; P < 0.001) domains. Internal consistency was good/excellent for overall TASQ score (α = 0.891) and for the physical limitation, emotional impact, and social limitation domains (α = 0.815-0.950). Test-retest reliability was excellent or strong for the overall TASQ (intraclass correlation coefficient of 0.883) and for the physical symptoms, physical limitation, emotional impact, and social limitation domains (intraclass correlation coefficient of 0.791-0.895). Responsiveness was medium overall (Cohen's d = 0.637) and medium/large for physical symptoms, emotional impact, and physical limitations (0.661-0.812). Sensitivity to change was significant for physical symptoms, physical limitations (both P < 0.001), emotional impact (P = 0.003), and social limitations (P = 0.038). CONCLUSIONS: The TASQ is a new, brief, self-administered, and clinically relevant health-specific tool to measure changes in quality of life in patients with AS undergoing an intervention.
- MeSH
- Aortic Valve MeSH
- Aortic Valve Stenosis * diagnosis surgery MeSH
- Quality of Life * MeSH
- Humans MeSH
- Prospective Studies MeSH
- Surveys and Questionnaires MeSH
- Reproducibility of Results MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Europe MeSH
- Canada MeSH
BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.
- MeSH
- Aortic Valve Stenosis * surgery MeSH
- Benchmarking * MeSH
- Patient Safety MeSH
- Length of Stay * statistics & numerical data MeSH
- Critical Pathways MeSH
- Humans MeSH
- Postoperative Complications epidemiology prevention & control MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Transcatheter Aortic Valve Replacement * methods MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Geographicals
- Europe MeSH