graphene derivatives
Dotaz
Zobrazit nápovědu
In response to the growing need for development of modern biomaterials for applications in regenerative medicine strategies, the research presented here investigated the biological potential of two types of polymer nanocomposites. Graphene oxide (GO) and partially reduced graphene oxide (rGO) were incorporated into a poly(ε-caprolactone) (PCL) matrix, creating PCL/GO and PCL/rGO nanocomposites in the form of membranes. Proliferation of osteoblast-like cells (human U-2 OS cell line) on the surface of the studied materials confirmed their biological activity. Fluorescence microscopy was able to distinguish the different patterns of interaction between cells (depending on the type of material) after 15 days of the test run. Raman micro-spectroscopy and two-dimensional correlation spectroscopy (2D-COS) applied to Raman spectra distinguished the nature of cell-material interactions after only 8 days. Combination of these two techniques (Raman micro-spectroscopy and 2D-COS analysis) facilitated identification of a much more complex cellular response (especially from proteins) on the surface of PCL/GO. The presented approach can be regarded as a method for early study of the bioactivity of membrane materials.
- MeSH
- grafit * farmakologie chemie MeSH
- lidé MeSH
- osteoblasty MeSH
- polyestery chemie MeSH
- polymery MeSH
- Ramanova spektroskopie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Graphene-based bionanocomposites are employed in several ailments, such as cancers and infectious diseases, due to their large surface area (to carry drugs), photothermal properties, and ease of their functionalization (owing to their active groups). Modification of graphene-derivatives with polysaccharides is a promising strategy to decrease their toxicity and improve target ability, which consequently enhances their biotherapeutic efficacy. Herein, functionalization of graphene-based materials with carbohydrate polymers (e.g., chitosan, starch, alginate, hyaluronic acid, and cellulose) are presented. Subsequently, recent advances in graphene nanomaterial/polysaccharide-based bionanocomposites in infection treatment and cancer therapy are comprehensively discussed. Pharmacogenomic and toxicity assessments for these bionanocomposites are also highlighted to provide insight for future optimized and smart investigations and researches.
- MeSH
- farmakogenetika * MeSH
- grafit chemie MeSH
- lidé MeSH
- nádory farmakoterapie genetika patologie MeSH
- nanokompozity aplikace a dávkování chemie MeSH
- nežádoucí účinky léčiv etiologie patologie MeSH
- polysacharidy chemie farmakologie MeSH
- protinádorové látky chemie farmakologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
With the increased demand for beef in emerging markets, the development of quality-control diagnostics that are fast, cheap and easy to handle is essential. Especially where beef must be free from pork residues, due to religious, cultural or allergic reasons, the availability of such diagnostic tools is crucial. In this work, we report a label-free impedimetric genosensor for the sensitive detection of pork residues in meat, by leveraging the biosensing capabilities of graphene acid - a densely and selectively functionalized graphene derivative. A single stranded DNA probe, specific for the pork mitochondrial genome, was immobilized onto carbon screen-printed electrodes modified with graphene acid. It was demonstrated that graphene acid improved the charge transport properties of the electrode, following a simple and rapid electrode modification and detection protocol. Using non-faradaic electrochemical impedance spectroscopy, which does not require any electrochemical indicators or redox pairs, the detection of pork residues in beef was achieved in less than 45 min (including sample preparation), with a limit of detection of 9% w/w pork content in beef samples. Importantly, the sample did not need to be purified or amplified, and the biosensor retained its performance properties unchanged for at least 4 weeks. This set of features places the present pork DNA sensor among the most attractive for further development and commercialization. Furthermore, it paves the way for the development of sensitive and selective point-of-need sensing devices for label-free, fast, simple and reliable monitoring of meat purity.
This study provides a review of the therapeutic potential of graphene dressing scaffolds and mesenchymal stem cells (MSCs) and their synergistic effects with respect to cutaneous wound healing. This study also considers their putative action mechanism based on the antibacterial, immunomodulating, angiogenic, matrix remodeling effects of materials belonging to the graphene family and MSCs during the wound healing process. In addition, this study discusses the cytocompatibility of graphene, its uses as a platform for skin substitutes, the properties it possesses with respect to providing protection against microbial invasion as well as strategies aimed at minimizing the chance of the occurrence of sepsis. MSCs are capable of secreting several factors that exert a therapeutic impact on reparative processes and tissue regeneration. In light of experiments conducted to date, graphene combined with MSCs appears to have the potential to enhance both the wound healing process and infection control at the injury site.
- MeSH
- grafit chemie farmakologie MeSH
- hojení ran účinky léků MeSH
- imunomodulace účinky léků MeSH
- kůže účinky léků zranění patologie MeSH
- lidé MeSH
- mezenchymální kmenové buňky cytologie účinky léků MeSH
- transplantace mezenchymálních kmenových buněk * MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
The cytocompatibility of cardiomyocytes derived from embryonic stem cells and neural progenitors, which were seeded on the surface of composite films made of graphene oxide (GO) and polypyrrole (PPy-GO) or poly(3,4-ethylenedioxythiophene) (PEDOT-GO) are reported. The GO incorporated in the composite matrix contributes to the patterning of the composite surface, while the electrically conducting PPy and PEDOT serve as ion-to-electron transducers facilitating electrical stimulation/sensing. The films were fabricated by a simple one-step electropolymerization procedure on electrically conducting indium tin oxide (ITO) and graphene paper (GP) substrates. Factors affecting the cell behaviour, i.e. the surface topography, wettability, and electrical surface conductivity, were studied. The PPy-GO and PEDOT-GO prepared on ITO exhibited high surface conductivity, especially in the case of the ITO/PPy-GO composite. We found that for cardiomyocytes, the PPy-GO and PEDOT-GO composites counteracted the negative effect of the GP substrate that inhibited their growth. Both the PPy-GO and PEDOT-GO composites prepared on ITO and GP significantly decreased the cytocompatibility of neural progenitors. The presented results enhance the knowledge about the biological properties of electroactive materials, which are critical for tissue engineering, especially in context stimuli-responsive scaffolds.
- MeSH
- bicyklické sloučeniny heterocyklické chemie MeSH
- elektrická vodivost * MeSH
- elektrochemie * MeSH
- grafit farmakologie MeSH
- kardiomyocyty cytologie účinky léků MeSH
- myši MeSH
- nervové kmenové buňky cytologie účinky léků MeSH
- neurogeneze účinky léků MeSH
- polymery chemie farmakologie MeSH
- pyrroly chemie MeSH
- voda chemie MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Graphene oxide (GO) as the most studied hydrophilic graphene derivative can be deployed in a broad spectrum of environmental technologies opening the issue of its ecotoxicity. Nevertheless, the information about its behavior in complex aquatic environment is still not sufficient. Here, we studied the interaction of three differently oxidized GO systems with planktonic and benthic crustaceans. By standard toxicity tests, we observed the importance of feeding strategy as well as the surface oxidation of GO with respect to GO's ecotoxicity. However, to gain a clearer insight into GO's environmental fate, we introduced a pre-treatment with algae as the most common source of food for crustaceans. Such an adjustment mimicking the conditions in real aquatic ecosystems resulted in complete mitigation of acute toxicity of GOs to all organisms and, more importantly, to the eradication of oxidative stress caused by GOs. We argue, that the pre-exposition of food is a crucial factor in GO's overall environmental fate, even though this fact has been completely neglected in recent studies. These experiments proved that GO is not a hazardous material in complex aquatic environments because its acute toxicity can be successfully mitigated through the interaction with algae even at very high concentrations (25 mg/L).
- MeSH
- chemické látky znečišťující vodu * toxicita MeSH
- ekosystém MeSH
- grafit * toxicita MeSH
- plankton MeSH
- testy toxicity MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Androgen receptor (AR) signalling is triggered by androgens that have lipophilic nature. Since it was indicated that graphene oxide (GO) might facilitate passive diffusion of lipophilic compounds probably via Trojan horse-like mechanism, we tested the hypothesis if this suggestion would apply for androgens as well. Thus, we investigated if GO affects dihydrotestosterone (DHT)-triggered signalling of AR in two prostate cancer-derived cell lines, 22Rv1 and LNCaP. These cell lines differ in number of AR variants, i.e. there are two variants in 22Rv1 cells (full length and truncated) but only one in LNCaP cells (full length). Graphene oxide had no effect on basal luciferase activity but significantly decreased DHT-inducible AR-dependent luciferase activity in stably transfected cells. In 22Rv1 cells, it induced concentration-dependent decrease of DHT-inducible KLK3 mRNA and PSA protein after 24 h. While there was no effect on UBE2C mRNA (regulated by truncated variant), there was synergistic effect of DHT and GO on UBE2C protein level. Translocation of full-length AR (AR-FL) was potentiated by GO in the presence of DHT in 22Rv1 cells but it was suppressed in LNCaP cells. DHT-stimulated enrichment of AR-FL on KLK3 promoter was not significantly affected by GO in any tested cell line neither was KLK3 mRNA at 4 h of incubation. In conclusion, GO affects DHT-triggered signalling in both types of cells in similar manner, but ligand-triggered redistribution of AR-FL is affected differently. One of the reasons may be the presence of truncated variant of androgen receptor.
- MeSH
- androgenní receptory * genetika MeSH
- androgeny MeSH
- dihydrotestosteron farmakologie MeSH
- grafit MeSH
- lidé MeSH
- nádorové buněčné linie MeSH
- nádory prostaty * MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Since biological applications and toxicity of graphene-based materials are structure dependent, studying their interactions with the biological systems is very timely and important. We studied short-term (1, 24, and 48 h) effects of ultrapure (GO) and Mn2+-contaminated (GOS) graphene oxide on normal human dermal fibroblasts (NHDF) and adenocarcinomic human alveolar basal epithelial cells (A549) using selected oxidative stress markers and cytokines: glutathione reductase (GR) and catalase (CAT) activity, total antioxidative capacity (TAC), and malondialdehyde (MDA) concentration, levels of vascular endothelial growing factor (VEGF), tumor necrosis factor-alpha (TNF-α), platelet-derived growth factor-BB (PDGF-BB), and eotaxin. GOS induced higher levels of oxidative stress, measured with CAT activity, TAC, and MDA concentration than GO in both cell lines when compared to control cells. GR activity decreased in time in NHDF cells but increased in A549 cells. The levels of cytokines were related to the exposure time and graphene oxide type in both analyzed cell lines and their levels comparably increased over time. We observed higher TNF-α levels in NHDF and higher levels of VEGF and eotaxin in the A549 cell line. Both types of cells showed similar susceptibility to GO and GOS. We concluded that the short-time exposure to GOS induced the stronger response of oxidative stress markers without collapsing the antioxidative systems of analysed cells. Increased levels of inflammatory cytokines after GO and GOS exposure were similar both in NHDF and A549 cells.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: High-resolution continuum source AAS is an emerging technique for the determination of trace elements in clinical analysis. We aimed to develop a method for the direct determination of platinum (Pt) in pleural effusions that could deepen the understanding of the dynamics of intrapleural Pt concentration during cytostatic therapy. MATERIALS AND METHODS: Samples were collected by thoracic drainage from five patients with lung cancer undergoing platinum based chemotherapy. A simple dilute-and-shoot method for Pt determination in the pleural effusions was developed. Ashing of the sample in an oxygen flow in a graphite tube allowed for direct analysis without prior mineralization. The trueness of the method was verified using an independent technique (ICP-MS). As platinum derivatives are only active in its free form (not bound to proteins), Pt in samples was further divided into free and protein-bound forms by means of ultrafiltration. RESULTS: Using the proposed method, Pt contents (free and total) were determined in samples collected at different times after the intravenous application of the Pt derivative. The concentration of total Pt reached values of up to 5,000 μg/L and different patterns of its dynamics in intrapleural fluid were observed. CONCLUSIONS: The developed method enables the fast and simple determination of Pt in biological fluids. It may be applied on a large scale to improve the understanding of Pt dynamics during cytostatic therapy, and also to determine the optimal timing of both thoracic drainage and administration of systemic chemotherapy.
- MeSH
- cytostatické látky * MeSH
- grafit * MeSH
- lidé MeSH
- nádory plic * MeSH
- platina MeSH
- pleurální výpotek * farmakoterapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: The aim of this study was to determine fluence corrections necessary to convert absorbed dose to graphite, measured by graphite calorimetry, to absorbed dose to water. Fluence corrections were obtained from experiments and Monte Carlo simulations in low- and high-energy proton beams. METHODS: Fluence corrections were calculated to account for the difference in fluence between water and graphite at equivalent depths. Measurements were performed with narrow proton beams. Plane-parallel-plate ionization chambers with a large collecting area compared to the beam diameter were used to intercept the whole beam. High- and low-energy proton beams were provided by a scanning and double scattering delivery system, respectively. A mathematical formalism was established to relate fluence corrections derived from Monte Carlo simulations, using the fluka code [A. Ferrari et al., "fluka: A multi-particle transport code," in CERN 2005-10, INFN/TC 05/11, SLAC-R-773 (2005) and T. T. Böhlen et al., "The fluka Code: Developments and challenges for high energy and medical applications," Nucl. Data Sheets 120, 211-214 (2014)], to partial fluence corrections measured experimentally. RESULTS: A good agreement was found between the partial fluence corrections derived by Monte Carlo simulations and those determined experimentally. For a high-energy beam of 180 MeV, the fluence corrections from Monte Carlo simulations were found to increase from 0.99 to 1.04 with depth. In the case of a low-energy beam of 60 MeV, the magnitude of fluence corrections was approximately 0.99 at all depths when calculated in the sensitive area of the chamber used in the experiments. Fluence correction calculations were also performed for a larger area and found to increase from 0.99 at the surface to 1.01 at greater depths. CONCLUSIONS: Fluence corrections obtained experimentally are partial fluence corrections because they account for differences in the primary and part of the secondary particle fluence. A correction factor, F(d), has been established to relate fluence corrections defined theoretically to partial fluence corrections derived experimentally. The findings presented here are also relevant to water and tissue-equivalent-plastic materials given their carbon content.
- MeSH
- algoritmy MeSH
- cyklotrony MeSH
- dávka záření MeSH
- grafit MeSH
- kalorimetrie přístrojové vybavení metody MeSH
- metoda Monte Carlo MeSH
- nejistota MeSH
- počítačová simulace MeSH
- protonová terapie přístrojové vybavení metody MeSH
- protony MeSH
- teplota MeSH
- tlak MeSH
- voda MeSH
- Publikační typ
- časopisecké články MeSH