The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500-3000 Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant.
- MeSH
- acetabulum fyziologie chirurgie MeSH
- analýza metodou konečných prvků MeSH
- analýza selhání vybavení metody MeSH
- biologické modely * MeSH
- kyčelní protézy MeSH
- lidé středního věku MeSH
- lidé MeSH
- mechanický stres MeSH
- modul pružnosti fyziologie MeSH
- náhrada kyčelního kloubu přístrojové vybavení metody MeSH
- oscilometrie metody MeSH
- počítačová simulace MeSH
- protetické vybavení metody MeSH
- reprodukovatelnost výsledků MeSH
- senzitivita a specificita MeSH
- vibrace MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Structure and properties of several ultrahigh-molecular-weight polyethylenes (UHMWPEs), which were crosslinked either by standard, single-step irradiation or by newer, several-step irradiation (sequential irradiation), were compared. To verify the results, the same characterization was carried out for commercially available UHMWPE liners made of sequentially irradiated polymer (X3™, Stryker, Mahwah, NJ) and one-step irradiated polymer (denoted as PE-IMC, produced by Beznoska, Kladno, Czech Republic). The structure was studied by a number of spectroscopic, diffraction, thermal, and microscopic methods. Mechanical properties were assessed by small-punch, microhardness and, wear testing. Our results suggested that sequential irradiation followed by annealing did not lead to unusual structure at the molecular or supermolecular level. Consequently, all measured mechanical properties, including wear resistance, were comparable with one-step irradiated UHMWPEs.
Aloplastika velkých kloubů je v dnešní době nepostradatelnou a stěžejní součástí moderní ortopedie. S rozvojem operační techniky, kvality implantátů, prodlužováním průměrného věku, ale i s rostoucími nároky pacientů dochází k nárůstu primoimplantací všech velkých kloubů. V posledních desetiletích k tomu došlo především u primoimplantací kyčelního a kolenního kloubu. V současné době se ale výrazně zvyšuje i počet náhrad ramenního, hlezenného i loketního kloubu. S tím souvisí i nárůst reimplantací jednotlivých kloubních náhrad. Tento trend klade nároky zejména na zvyšování kvality artikulačních materiálů používaných pro kloubní náhrady. Vysokomolekulární polyetylén (ultra-high molecular weight polyethylene – UHMWPE) je v dnešní době nejčastěji používaným materiálem pro výrobu artikulačních komponent kloubních náhrad. Kvalita jednotlivých komponent je jedním z rozhodujících faktorů, které ovlivňují celkovou životnost endoprotézy. V ortopedii je vysokomolekulární polyetylén používán již od 60. let minulého století. Vlastnosti UHMWPE jsou od počátku cílem řady vědeckých studií, které vedly k postupnému zdokonalování jeho vlastností a tudíž prodloužení jeho životnosti in vivo. Práce informuje nejen o vývoji polyetylénových komponent kloubních náhrad ve světě, ale zároveň poukazuje na vývoj tuzemský, který doposud dokázal držet krok s nejmodernějšími světovými trendy v oblasti artikulačních komponent kloubních náhrad. Hlavním cílem tohoto přehledového článku je čtenáře seznámit se základními vlastnosti vysokomolekulárního polyetylénu, možnostmi jeho modifikace a sterilizace. Důležitou částí je nastínění vývoje jednotlivých generací UHMWPE a rozdílů mezi nimi. Seznámení s nejnovějšími poznatky, obsaženými v této práci, by mělo pomoci operatérovi při volbě finálního výrobku tak, aby mohl minimalizovat riziko předčasného selhání kloubní náhrady.
Total joint arthroplasty is an essential and crucial part of modern orthopedics. The improvements in surgical techniques and implant quality, the growing average age of patients, and higher demands of patients contribute to the increasing number of primary implantations of all major joints. In the last decade the authors have witnessed a massive increase in primary replacements of the hip and knee joint. Also the numbers of shoulder, ankle and elbow replacements have been growing. This resulted in a higher number of prosthetic reimplantations. This trend imposes even higher requirements on improving the quality of articulation materials used for joint replacement. Ultra-high molecular weight polyethylene (UHMWPE) is nowadays the most commonly used material of articulation components of the joint replacement. The quality of UHMWPE components is one of the key factors that influence the overall life of the prosthesis. In the field of orthopedics UHMWPE has been used since the 1960s. From the very beginning, the structure and properties of UHMWPE were a subject of scientific studies that led to the gradual improvement of the polymer performance and its in vivo lifetime. This work summarizes the information about both historical and recent UHMWPE components of joint replacements in the world, but also refers to research in the Czech Republic, which so far has been keeping pace with the latest world trends. The main objective of this review is to introduce the reader into the basic properties of high-molecular polyethylene, the possibilities of its modification and sterilization. The authors also explain the difference among various types and generations of UHMWPE. This information should help an orthopedic surgeon in choosing a particular type of UHMWPE so that the risk of early failure of joint replacement was minimized.
- Klíčová slova
- totální endoprotéza kloubu, UHMWPE, vysokomolekulární polyetylén, etylénoxid, síťování, tepelné úpravy,
- MeSH
- lidé MeSH
- náhrada kyčelního kloubu * metody přístrojové vybavení MeSH
- protézy kloubů * MeSH
- vitamin E MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- přehledy MeSH
V článku věnujeme pozornost novému trendu v přípravě UHMWPE se zvýšenou odolností vůči otěru, obecně uváděnému jako síťování (crosslinking). Takto modifikovaný UHMWPE lze charakterizovat vyšším stupněm příčných vazeb a žádným, resp. minimálním počtem volných radikálů. Síťovaný UHMWPE se získává ve dvou krocích. Nejprve se UHMWPE za určitých, přesně daných podmínek ozáří ionizujícím zářením a následně prochází tepelnou úpravou, kterou se likvidují vzniklé zbytkové radikály. Správným způsobem modifikovaný polymer vykazuje výrazně vyšší odolnost vůči otěru.
In the article, we focus on a new trend in the preparation of UHMWPE, generally called cross-linking, that provides for a greater resistance to abrasion. UHMWPE thus modified features a higher degree of perpendicular fiber structure and none or rather minimal quantity of loose radicals. Cross-linked UHMWPE is produced in two steps. Firstly, UHMWPE is exposed to ionized radiation, under certain strictly controlled conditions and, subsequently, it undergoes thermal processing that liquidates any remaining loose radicals. Polymer properly modified in this manner possesses distinctly higher resistance to wear.
Závěrečná zpráva o řešení grantu Interní grantové agentury MZ ČR
12 l. : il. ; 30 cm
Jedná se o nový tvar lžíce laryngoskopu,který podstatně ovlivňuje jeho funkci.Změnou se laryngoskop stává použitelný pro obtížné intubace a nedochází k poškození zubů pacienta.Protože jde o nový tvar lžíce,je nutno výrobek ověřit v multicentrické studii.
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- otorinolaryngologie
- anesteziologie a intenzivní lékařství
- NLK Publikační typ
- závěrečné zprávy o řešení grantu IGA MZ ČR