- MeSH
- blokáda Tawarova raménka etiologie terapie MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční MeSH
- Hisův svazek * MeSH
- kardiomyopatie * etiologie terapie MeSH
- kardiostimulace umělá škodlivé účinky MeSH
- lidé MeSH
- srdeční komory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The conduction system of the human heart is composed of specialized cardiomyocytes that initiate and propagate the electric impulse with consequent rhythmic and synchronized contraction of the atria and ventricles, resulting in the normal cardiac cycle. Although the His-Purkinje system (HPS) was already described more than a century ago, there has been a recent resurgence of conduction system pacing (CSP), where pacing leads are positioned in the His bundle region and left bundle branch area to provide physiological cardiac activation as alternatives to the unnatural myocardial stimulation obtained with conventional right ventricular and biventricular pacing. In this review, we describe the fundamental anatomical and pathophysiological aspects of the specialized HPS along with the CSP technique's nuts and bolts to highlight its potential benefits in everyday clinical practice.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Right ventricular pacing (RVP) can result in pacing-induced cardiomyopathy (PICM). It is unknown whether specific biomarkers reflect differences between His bundle pacing (HBP) and RVP and predict a decrease in left ventricular function during RVP. AIMS: We aimed to compare the effect of HBP and RVP on the left ventricular ejection fraction (LVEF) and to study how they affect serum markers of collagen metabolism. METHODS: Ninety-two high-risk PICM patients were randomized to HBP or RVP groups. Their clinical characteristics, echocardiography, and serum levels of transforming growth factor β1 (TGF-β1), matrix metalloproteinase 9 (MMP-9), suppression of tumorigenicity 2 interleukin (ST2-IL), tissue inhibitor of metalloproteinase 1 (TIMP-1), and galectin 3 (Gal-3) were studied before pacemaker implantation and six months later. RESULTS: Fifty-three patients were randomized to the HBP group and 39 patients to the RVP group. HBP failed in 10 patients, who crossed over to the RVP group. Patients with RVP had significantly lower LVEF compared to HBP patients after six months of pacing (-5% and -4% in as-treated and intention-to-treat analysis, respectively). Levels of TGF-β1 after 6 months were lower in HBP than RVP patients (mean difference -6 ng/ml; P = 0.009) and preimplant Gal-3 and ST2-IL levels were higher in RVP patients, with a decline in LVEF ≥5% compared to those with a decline of <5% (mean difference 3 ng/ml and 8 ng/ml; P = 0.02 for both groups). CONCLUSION: In high-risk PICM patients, HBP was superior to RVP in providing more physiological ventricular function, as reflected by higher LVEF and lower levels of TGF-β1. In RVP patients, LVEF declined more in those with higher baseline Gal-3 and ST2-IL levels than in those with lower levels.
- MeSH
- biologické markery MeSH
- elektrokardiografie MeSH
- funkce levé komory srdeční * fyziologie MeSH
- Hisův svazek MeSH
- interleukin-1 receptor-like 1 protein MeSH
- kardiomyopatie * MeSH
- kardiostimulace umělá škodlivé účinky MeSH
- kolagen MeSH
- lidé MeSH
- tepový objem fyziologie MeSH
- tkáňový inhibitor metaloproteinasy 1 MeSH
- transformující růstový faktor beta1 MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: Left bundle branch area pacing (LBBAP) is an emerging technique to achieve cardiac resynchronization therapy (CRT), but its feasibility and safety in elderly patients with heart failure with reduced ejection fraction and left bundle branch block is hardly investigated. METHODS: We enrolled consecutive patients with an indication for CRT comparing pacing parameters and complication rates of LBBAP-CRT in elderly patients (≥ 75 years) versus younger patients (< 75 years) over a 6-month follow-up. RESULTS: LBBAP was successful in 55/60 enrolled patients (92%), among which 25(45%) were elderly. In both groups, LBBAP significantly reduced the QRS duration (elderly group: 168 ± 15 ms to 136 ± 12 ms, p < 0.0001; younger group: 166 ± 14 ms to 134 ± 11 ms, p < 0.0001) and improved LVEF (elderly group: 28 ± 5% to 40 ± 7%, p < 0.0001; younger group: 29 ± 5% to 41 ± 8%, p < 0.0001). The pacing threshold was 0.9 ± 0.8 V in the elderly group vs. 0.7 ± 0.5 V in the younger group (p = 0.350). The R wave was 9.5 ± 3.9 mV in elderly patients vs. 10.7 ± 2.7 mV in younger patients (p = 0.341). The fluoroscopic (elderly: 13 ± 7 min vs. younger: 11 ± 7 min, p = 0.153) and procedural time (elderly: 80 ± 20 min vs. younger: 78 ± 16 min, p = 0.749) were comparable between groups. Lead dislodgement occurred in 2(4%) patients, 1 in each group (p = 1.000). Intraprocedural septal perforation occurred in three patients (5%), 2(8%) in the elderly group (p = 0.585). One patient (2%) in the elderly group had a pocket infection. CONCLUSIONS: LBBAP is a feasible and safe technique for delivering physiological pacing in elderly patients who are candidates for CRT with suitable pacing parameters and low complication rates.
- MeSH
- elektrokardiografie metody MeSH
- Hisův svazek MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- lidé MeSH
- senioři MeSH
- srdeční resynchronizační terapie * metody MeSH
- studie proveditelnosti MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Device-based algorithms offer the potential for automated optimization of cardiac resynchronization therapy (CRT), but the process for accepting them into clinical use is currently still ad-hoc, rather than based on pre-clinical and clinical testing of specific features of validity. We investigated how the QuickOpt-guided VV delay (VVD) programming performs against the clinical and engineering heuristic of QRS complex shortening by CRT. METHODS: A prospective, 2-center study enrolled 37 consecutive patients with CRT. QRS complex duration (QRSd) was assessed during intrinsic atrioventricular conduction, synchronous biventricular pacing, and biventricular pacing with QuickOpt-proposed VVD. The measurements were done manually by electronic calipers in signal-averaged and magnified 12-lead QRS complexes. RESULTS: Native QRSd was 174 ± 22 ms. Biventricular pacing with empiric AVD and synchronous VVD resulted in QRSd 156 ± 20 ms, a significant narrowing from the baseline QRSd by 17 ± 27 ms, P = 0.0003. In 36 of 37 patients, the QuickOpt algorithm recommended left ventricular preexcitation with VVD of 42 ± 18 ms (median 40 ms; interquartile range 30-55 ms, P <0.00001). QRSd in biventricular pacing with QuickOpt-based VVD was significantly longer compared with synchronous biventricular pacing (168 ± 25 ms vs. 156 ± 20 ms; difference 12 ± 11ms; P <0.00001). This prolongation correlated with the absolute VVD value (R = 0.66, P <0.00001). CONCLUSIONS: QuickOpt algorithm systematically favours a left-preexcitation VVD which translates into a significant prolongation of the QRSd compared to synchronous biventricular pacing. There is no reason to believe that a manipulation that systematically widens QRSd should be considered to optimize physiology. Device-based CRT optimization algorithms should undergo systematic mechanistic pre-clinical evaluation in various scenarios before they are tested in large clinical studies.
AIMS: Permanent transseptal left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. However, data regarding safety, feasibility and capture type are limited to relatively small, usually single centre studies. In this large multicentre international collaboration, outcomes of LBBAP were evaluated. METHODS AND RESULTS: This is a registry-based observational study that included patients in whom LBBAP device implantation was attempted at 14 European centres, for any indication. The study comprised 2533 patients (mean age 73.9 years, female 57.6%, heart failure 27.5%). LBBAP lead implantation success rate for bradyarrhythmia and heart failure indications was 92.4% and 82.2%, respectively. The learning curve was steepest for the initial 110 cases and plateaued after 250 cases. Independent predictors of LBBAP lead implantation failure were heart failure, broad baseline QRS and left ventricular end-diastolic diameter. The predominant LBBAP capture type was left bundle fascicular capture (69.5%), followed by left ventricular septal capture (21.5%) and proximal left bundle branch capture (9%). Capture threshold (0.77 V) and sensing (10.6 mV) were stable during mean follow-up of 6.4 months. The complication rate was 11.7%. Complications specific to the ventricular transseptal route of the pacing lead occurred in 209 patients (8.3%). CONCLUSIONS: LBBAP is feasible as a primary pacing technique for both bradyarrhythmia and heart failure indications. Success rate in heart failure patients and safety need to be improved. For wider use of LBBAP, randomized trials are necessary to assess clinical outcomes.
- MeSH
- blokáda Tawarova raménka terapie etiologie MeSH
- bradykardie terapie etiologie MeSH
- elektrokardiografie metody MeSH
- Hisův svazek * MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- lidé MeSH
- senioři MeSH
- srdeční selhání * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: QRS complex shortening by cardiac resynchronization therapy (CRT) has been associated with improved outcomes. OBJECTIVE: We hypothesized that the absence of QRS duration (QRSd) prolongation by right ventricular mid-septal pacing (RVP) may indicate complete left bundle branch block (cLBBB). METHODS: We prospectively collected 12-lead surface electrocardiograms (ECGs) and intracardiac electrograms during CRT implant procedures. Digital recordings were edited and manually measured. The outcome measure was a change in QRSd induced by CRT (delta CRT). Several outcome predictors were investigated: native QRSd, cLBBB (by using Strauss criteria), interval between the onset of the QRS complex and the local left ventricular electrogram (Q-LV), and a newly proposed index defined by the difference between RVP and native QRSd (delta RVP). RESULTS: One hundred thirty-three consecutive patients were included in the study. Delta RVP was 27 ± 25 ms, and delta CRT was -14 ± 28 ms. Delta CRT correlated with native QRSd (r = -0.65), with the presence of ECG-based cLBBB (r = -0.40), with Q-LV (r = -0.68), and with delta RVP (r = 0.72) (P < .00001 for all correlations). In multivariable analysis, delta CRT was most strongly associated with delta RVP (P < .00001), followed by native QRSd and Q-LV, while ECG-based cLBBB became a nonsignificant factor. CONCLUSION: Baseline QRSd, delta RVP, and LV electrical lead position (Q-LV) represent strong independent predictors of ECG response to CRT. The absence of QRSd prolongation by RVP may serve as an alternative and more specific marker of cLBBB. Delta RVP correlates strongly with the CRT effect on QRSd and outperforms the predictive value of ECG-based cLBBB.
- MeSH
- blokáda Tawarova raménka diagnóza patofyziologie terapie MeSH
- elektrofyziologické techniky kardiologické metody MeSH
- funkce levé komory srdeční fyziologie MeSH
- lidé MeSH
- následné studie MeSH
- prediktivní hodnota testů MeSH
- převodní systém srdeční patofyziologie MeSH
- prospektivní studie MeSH
- senioři MeSH
- srdeční komory patofyziologie MeSH
- srdeční resynchronizační terapie metody MeSH
- tepový objem fyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: His-Bundle pacing (HBP) is an emerging technique for physiological pacing. However, its effects on right ventricle (RV) performance are still unknown. METHODS: We enrolled consecutive patients with an indication for pacemaker (PM) implantation to compare HBP versus RV pacing (RVP) effects on RV performance. Patients were evaluated before implantation and after 6 months by a transthoracic echocardiogram. RESULTS: A total of 84 patients (age 75.1±7.9 years, 64% male) were enrolled, 42 patients (50%) underwent successful HBP, and 42 patients (50%) apical RVP. At follow up, we found a significant improvement in RV-FAC (Fractional Area Change)% [baseline: HBP 34 IQR (31-37) vs. RVP 33 IQR (29.7-37.2),p = .602; 6-months: HBP 37 IQR (33-39) vs. RVP 30 IQR (27.7-35), p < .0001] and RV-GLS (Global Longitudinal Strain)% [baseline: HBP -18 IQR (-20.2 to -15) vs. RVP -16 IQR (-18.7 to -14), p = .150; 6-months: HBP -20 IQR(-23 to -17) vs. RVP -13.5 IQR (-16 to -11), p < .0001] with HBP whereas RVP was associated with a significant decline in both parameters. RVP was also associated with a significant worsening of tricuspid annular plane systolic excursion (TAPSE) (p < .0001) and S wave velocity (p < .0001) at follow up. Conversely from RVP, HBP significantly improved pulmonary artery systolic pressure (PASP) [baseline: HBP 38 IQR (32-42) mmHg vs. RVP 34 IQR (31.5-37) mmHg,p = .060; 6-months: HBP 32 IQR (26-38) mmHg vs. RVP 39 IQR (36-41) mmHg, p < .0001] and tricuspid regurgitation (p = .005) irrespectively from lead position above or below the tricuspid valve. CONCLUSIONS: In patients undergoing PM implantation, HBP ensues a beneficial and protective impact on RV performance compared with RVP.
- MeSH
- dysfunkce pravé srdeční komory patofyziologie terapie MeSH
- Hisův svazek patofyziologie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- senioři MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Z velkých randomizovaných kontrolovaných studií vyplývá, že implantabilní kardiovertery – defibrilátory (ICD) významně snižují mortalitu pacientů s vysokým rizikem náhlé srdeční smrti. I přes současné technologické pokroky jsou pacienti s ICD zatíženi rizikem neadekvátních výbojů pro jinou než život ohrožující arytmii. Výboje jsou pro pacienty nepříjemné, snižují kvalitu jejich života a mohou vyvolat jiné potenciálně závažné arytmie. Většina neadekvátních a zbytných intervencí ICD je způsobena příliš konzervativní programací, která je ošetřujícím lékařem často ponechána v podobě přednastavené antitachykardické terapie od výrobce. V tomto přehledu představujeme aktuální znalosti a doklady o možnostech programace ICD vedoucích ke snížení rizika neadekvátních a zbytných výbojů při zachování bezpečnosti a prospěchu pro pacienty.
Previous randomized controlled trials have shown that the implantable cardioverter–defibrillator (ICD) provides a significant mortality reduction in patients at high risk of sudden cardiac death. Despite technological advances, ICD patients still face a high incidence of therapies delivered for causes other that life-threatening ventricular arrhythmias. These unnecessary and inappropriate therapies, apart from being painful and psychologically disturbing, may also result in fatal tachyarrhythmias. A high proportion of unnecessary and inappropriate shocks is the result of a conservative and aggressive ICD programming. In this review we focus on recent evidences related to ICD programming and reduction of unnecessary/inappropriate therapies and propose ways to rational and evidence-based ICD programming of ICDs that can effectively reduce the number of unnecessary and/or inappropriate therapies and maximize benefit from this highly successful therapy.
- Klíčová slova
- neadekvátní výboje,
- MeSH
- algoritmy MeSH
- defibrilátory implantabilní * dějiny trendy využití MeSH
- hodnotící studie jako téma MeSH
- lidé MeSH
- náhlá srdeční smrt * prevence a kontrola MeSH
- primární prevence metody normy MeSH
- sekundární prevence metody normy MeSH
- směrnice pro lékařskou praxi jako téma MeSH
- software MeSH
- srdeční arytmie * prevence a kontrola MeSH
- statistika jako téma MeSH
- tachykardie prevence a kontrola MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH