BACKGROUND: As the healthcare sector evolves, Artificial Intelligence's (AI's) potential to enhance laboratory medicine is increasingly recognized. However, the adoption rates and attitudes towards AI across European laboratories have not been comprehensively analyzed. This study aims to fill this gap by surveying European laboratory professionals to assess their current use of AI, the digital infrastructure available, and their attitudes towards future implementations. METHODS: We conducted a methodical survey during October 2023, distributed via EFLM mailing lists. The survey explored six key areas: general characteristics, digital equipment, access to health data, data management, AI advancements, and personal perspectives. We analyzed responses to quantify AI integration and identify barriers to its adoption. RESULTS: From 426 initial responses, 195 were considered after excluding incomplete and non-European entries. The findings revealed limited AI engagement, with significant gaps in necessary digital infrastructure and training. Only 25.6 % of laboratories reported ongoing AI projects. Major barriers included inadequate digital tools, restricted access to comprehensive data, and a lack of AI-related skills among personnel. Notably, a substantial interest in AI training was expressed, indicating a demand for educational initiatives. CONCLUSIONS: Despite the recognized potential of AI to revolutionize laboratory medicine by enhancing diagnostic accuracy and efficiency, European laboratories face substantial challenges. This survey highlights a critical need for strategic investments in educational programs and infrastructure improvements to support AI integration in laboratory medicine across Europe. Future efforts should focus on enhancing data accessibility, upgrading technological tools, and expanding AI training and literacy among professionals. In response, our working group plans to develop and make available online training materials to meet this growing educational demand.
- MeSH
- klinické laboratoře MeSH
- lidé MeSH
- průzkumy a dotazníky MeSH
- umělá inteligence * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
We present two cases from the neonatal department with cerebrospinal fluid examination. We revealed a striking discrepancy in polymorphonuclear (PMN) and mononuclear (MN) cell counts using conventional light microscopy in comparison with automated analyzer Sysmex XN-1000 (PMNs - 13 vs. 173x106/L, MNs - 200 vs. 67x106/L in case 1 and PMNs - 13 vs. 372x106/L, MNs - 411 vs. 179x106/L in case 2). We revealed the dominant presence of hemosiderophages in both cases in cytospin slide. Even though Sysmex XN-1000 offers fast examination with a low sample volume, there is possibility of misdiagnosis, with negative impact on the patient.
- MeSH
- leukocyty mononukleární patologie cytologie MeSH
- lidé MeSH
- mikroskopie * metody MeSH
- mozkomíšní mok cytologie MeSH
- neutrofily cytologie patologie MeSH
- novorozenec MeSH
- počet leukocytů MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
- srovnávací studie MeSH
OBJECTIVES: Both dimethylarginines are widely bound to chronic kidney disease (CKD). This study was focused to validate published LC-MS/MS method and compared the measured data with an immunoassay. DESIGN AND METHODS: The analysis was performed on a Dionex UltiMate 3000 UHPLC-Standard (Thermo Fisher Scientific, Waltham, Massachusetts, USA) with an amaZon SL ion trap (Bruker, Billerica, Massachusetts, USA). Comparison was evaluated by using Passing Bablok regression and Bland Altman plot. Healthy volunteers (n = 40) were used for validation and as control group to patients group (n = 40) with different stages of CKD. RESULTS: The results in healthy controls determined by the LC-MS/MS (ELISA) method were 0.52 ± 0.0892 with 95 % CI: 0.49-0.55 (0.61 ± 0.1213 with 95 % CI: 0.57-0.64) μmol/L for AD MA and 0.56 ± 0.0810 with 95 % CI: 0.53-0.58 (0.62 ± 0.0752 with 95 % CI: 0.57-0.65) μmol/L for SDMA. In the same way, the patient group values determined by the LC-MS/MS (ELISA) method were 0.82 ± 0.1604 with 95 % CI: 0.75-0.88 (1.06 ± 0.3002 with 95 % CI: 0.94-1.19) μmol/L and 2.14 ± 0.8778 with 95 % CI: 1.47-2.58 (1.65 ± 0.5160 with 95 % CI: 1.40-1.98) μmol/L for ADMA and SDMA, respectively. The correlation between the methods, expressed as the Spearman correlation coefficient (R), was 0.858 (0.8059) for ADMA (p < 0.0001) and 0.895 (0.9607) for SDMA (p < 0.0001). CONCLUSIONS: ADMA levels determined by the immunoassay were almost 30 % overestimated, in contrast to SDMA levels, which were 3 % underestimated. According to our findings, a better correlation could be obtained by simple sample dilution.
- Publikační typ
- časopisecké články MeSH
AIM: We present two cases with clearly discrepant results of clinical examination and cardiac troponin I (cTnI) and cardiac troponin T (cTnT) concentrations. In similar cases with discrepant results, the possibility of interference should be considered. METHODS: Due to the suspicion of the presence of macrotroponin I in both of the presented cases, the patients were invited to our laboratory and both cTnI (Architect i1000, Abbott) and cTnT (Cobas 8000, Roche) concentrations were analysed. The samples were treated by preincubation in a heterophilic antibodies blocking tube (HBT) and analysed. Precipitation with polyethylene glycol solution (PEG) and molecular weight separation by gel filtration on Sephadex G100 was performed and concentrations of cTnI were analysed. RESULTS: In the same blood sample, the cTnT and cTnI concentrations were 7 and 1782 ng/L, respectively, in Case 1, and 6 and 96 ng/L, respectively, in Case 2. Incubation of samples in HBT had no significant effect. CTnI concentrations after precipitation with PEG - presented as the percentage of initial concentrations - were 7.4% in Case 1 (and 26.8% in the control sample) and 1.4% in Case 2 (and 56.0% in the control sample). These results indicate a significant decrease in both cases, supporting presence of macrotroponin I. Finally, analyses of cTnI concentrations after gel filtration also supported the presence of macrotroponin I. CONCLUSION: The present cases show that the presence of macrotroponin can lead to unnecessary investigation of the patient. When the possibility of interference is suspected, cooperation with laboratory staff to help with interpretation or to perform more detailed analysis is crucial.
- MeSH
- biologické markery krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- troponin I * krev MeSH
- troponin T * krev MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
BACKGROUND: Even though electrical injuries are common in the emergency room, guidelines, consensus, and general recommendations for the management of these patients do not exist in Europe. Documented cases of delayed arrhythmias are rare and their connection with electrical injury has not been fully confirmed. We also use cardio-specific markers for the risk stratification of myocardial injury, but there is no significant study referring to their utility in this clinical situation. These reasons led us to retrospectively analyze all cases of electrical injuries over 23 years to determine the prevalence of cardiac arrhythmias (mainly malignant arrhythmias and delayed arrhythmias). METHODS: We retrospectively searched all patients admitted to the University Hospital in Pilsen, CZ, with a diagnosis of electric injury (ICD diagnostic code T754) from 1997 to 2020. The hospital ́s information system was used to research the injury; data were drawn from patient medical records. RESULTS: We identified 333 cases of electrical injury in our hospital. Men accounted for about two-thirds, and women one-third. Children accounted for about one-third of cases. Most were low-voltage injuries (< 1000 V, 91.6%). All participants had an initial ECG, and 77.5% of patients had continuous ECG monitoring, usually lasting 24 h. Cardiac arrhythmias were noticed in 39 patients (11.7%). The most frequent arrhythmias were: ventricular fibrillation, sinus tachycardia, bradycardia and arrhythmia, atrial fibrillation, and supraventricular tachycardia. The ECG showed cardiac conduction abnormalities in 28 patients (8.1%), and ten patients (3%) had supraventricular or ventricular extrasystoles. In ten cases (3%), we found changes in ST segments and T waves on the initial ECG. Thirty-one patients (9.3%) suffered a loss of consciousness and 50 patients (15.02%) reported paresthesia. The most frequent ion disbalances were hypokalemia (18%) and hypocalcemia (3.3%). Patients with an ion disbalance had significantly more arrhythmias and newly diagnosed cardiac conduction abnormalities. Troponin levels (cTnI or hs-cTnT) were measured in 258 cases (77.48%) and found to be elevated above the 99th percentile in 19 cases (5.7%). Almost one-third of patients had burns of various degrees of seriousness, and 41 patients (12.3%) had concomitant traumatic injuries. Eleven patients underwent pre-hospital resuscitation, three died in the hospital, and another died as result of intracranial hemorrhage. CONCLUSION: All malignant arrhythmias occurred immediately after the electrical injury, delayed life-threatening arrhythmias were not observed, and no predictive factors of malignant arrhythmias were found. While elevations of cardiac troponins were observed sporadically, they did not appear helpful for risk stratification. In patients with arrhythmias, ion disbalance may be more critical. We concluded that asymptomatic, uninjured adult and pediatric patients with normal initial ECG findings do not need continuous ECG monitoring and may be discharged home. Recommendations for high-risk patients and patients with mild ECG abnormalities at admission are less obvious.
- MeSH
- dítě MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- fibrilace síní * komplikace MeSH
- lidé MeSH
- nemoci převodního systému srdečního komplikace MeSH
- poranění elektrickým proudem * komplikace diagnóza epidemiologie MeSH
- retrospektivní studie MeSH
- sinusová tachykardie MeSH
- úrazy a nehody MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Immunochemical reactions are fast, can be automated, and generally do not require pretreatment of biological material. Based on these advantages, they are widely used. On the other hand, they are susceptible to analytical interference that can lead to inaccurate results. These factors include the presence of anti-mouse antibodies, causing false positive (or sometimes false negative) results. Although the anti-mouse antibodies over many decades have been repeatedly identified to be the causative source but due to the rarity of such encounters they remain insufficiently considered. Here we show a case, a 45 year-old female who was mis-diagnosed with pregnancy due to falsely elevated human chorionic gonadotropin (hCG) due to anti-mouse antibodies. This led to the patient undergoing two ultrasound examinations and laparoscopy before the hCG was repeated on alternative assays which showed negative results, preventing the patient from methotrexate treatment. Here we describe the details of the case, outline the assay principal, supporting the finding from literature and outlining a process on how to identify such interferences in timely manner.
- MeSH
- choriogonadotropin * MeSH
- falešně pozitivní reakce MeSH
- lidé středního věku MeSH
- lidé MeSH
- protilátky * MeSH
- těhotenství MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH