OBJECTIVE: Systematic review and meta-analysis on laboratory studies aimed to answer whether there is a difference in fracture resistance and fracture mode of structurally compromised teeth restored with direct composite restorations reinforced with short glass-fiber or bidirectional polyethylene fiber substructure, and between the two different fiber-reinforcement types. METHODS: An electronic literature search was conducted in Medline, Scopus, Web of Science, Lilacs, Google Scholar, Cochrane Library, and University Library databases. The last search was conducted on 16 November 2023. Only studies looking at Ribbond-reinforced restorations and/ or the use of EverX Posterior within restorations were included. Data were categorized and analyzed based on specific outcome measures including fracture resistance and fracture mode. Data from individual studies were divided into premolars and molars for each material category and then collated to compare the mean differences in fracture resistance between control groups (composite restorations) and intervention groups (fiber-reinforced composite restorations). RESULTS: From the initial 1266 articles identified, 23 laboratory-based studies were included for quantitative analysis. Twenty articles had an overall low risk of bias and 3 had an overall unclear risk of bias. The pooled estimate of the effect favored the intervention groups as having statistically significant higher fracture resistance when compared to control groups. CONCLUSIONS: Both fiber types improve fracture resistance and the fracture mode of structurally compromised teeth is equally efficient. Application technique deserves attention. Ribbond could be placed in a single layer at the cavity floor, whereas EverX Posterior should replace missing dentin in an anatomically shaped way.
- MeSH
- fraktury zubů * prevence a kontrola MeSH
- lidé MeSH
- polyethyleny MeSH
- sklo chemie MeSH
- složené pryskyřice * terapeutické užití chemie MeSH
- trvalá zubní náhrada * metody MeSH
- zubní materiály chemie MeSH
- zuby-sanace - selhání MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- práce podpořená grantem MeSH
- systematický přehled MeSH
OBJECTIVES: Comparisons of material hardness may be affected by the indentation size effect (ISE), which is characterized by increasing hardness values at decreasing loads. This study aimed to assess the influence of load, dwell time and measurement method on ISE in dental resin-based composites with different filler content. METHODS: Knoop (HK) and Vickers (HV) microindentation hardness of Filtek Ultimate Universal Restorative (FU) and Filtek Supreme Flowable Restorative (FF) was measured under different loads (0.098-2.96 N, i.e. 10-300 gf) and dwell times (5-30 s). Their effects on HK and HV were evaluated using repeated measures ANOVA, which was also used to compare the measurement methods. Coefficients of Meyer's equation, proportional specimen resistance (PSR) model and a modified PSR model were calculated using regression analyses. RESULTS: ISE was more pronounced for the highly-filled FU than for the less-filled FF, and HK was more susceptible to ISE than HV. The effect of dwell time was similar for both materials and measurement methods; hardness values decreased with dwell time, significantly between 5 s and 30 s. SIGNIFICANCE: The possible presence of ISE should be considered when determining measurement conditions for the microindentation hardness of dental resin-based composites. HV was found to be less sensitive to ISE and provided stable hardness values at lower loads than HK. Due to the high variability of composites, any hardness measurement should be preceded by mapping the effect of load to ensure that load-independent hardness is measured. If hardness values continue to decrease in the whole range of increasing loads, load-independent hardness can be calculated using the PSR model.
- MeSH
- složené pryskyřice * chemie MeSH
- testování materiálů * MeSH
- testy tvrdosti MeSH
- tvrdost * MeSH
- Publikační typ
- časopisecké články MeSH
The color-matching ability of single-shade composites Omnichroma (OMN) and Omnichroma Flow (OCF) is ensured by structural color, which arises from monodisperse 260 nm spherical fillers. This study evaluated how filler load influences the color adjustment potential of composite restorations to human teeth of various shades. The performance of composites containing the 260 nm spherical fillers -OMN (79 wt%), OCF (71 wt%), and experimental composites R1 (65 wt%), and R2 (60 wt%)- was compared to two conventional A2-shade composites and a transparent composite. Additionally, the translucency parameter, spectral reflectance, and light transmission properties were assessed. Composites with a lower load of the 260 nm spherical fillers exhibited lower light diffusion and lower reflectance in the yellow-to-red range (580-650 nm), which is characteristic for the structural color of OMN and OCF. The best color adjustment was achieved with OCF, presumably due to its high translucency and uniform spectral reflectance.
- MeSH
- barva MeSH
- lidé MeSH
- složené pryskyřice * chemie MeSH
- testování materiálů MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The recently introduced resin composites with a universal shade are claimed to match any tooth color. In this study, it was examined how composite thickness affects the color adjustment of conventional and universal-shade composites to background dentin. Thirty sound human central incisors of various shade were used, and color differences between their intact labial surfaces, exposed dentin surfaces and composite restorations (thickness 1-3 mm) were evaluated. In addition, the translucency, light transmission characteristics, and spectral reflectance of the composites were measured. The results showed that universal-shade composites outperformed conventional composites of A2 shade in the adjustment of hue and chroma (p<0.05) but not in lightness (p>0.05). The color adjustment potential of all composites significantly decreased as their thickness increased (p<0.05). The effect of thickness on Omnichroma and Omnichroma Flow was less marked, presumably because of their higher translucency (p<0.05) and structural coloration which induces light reflectance in the yellow-to-red range.
- MeSH
- barva MeSH
- dentin * MeSH
- lidé MeSH
- složené pryskyřice * chemie MeSH
- testování materiálů MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
STATEMENT OF PROBLEM: The bonding of light-activated adhesives to root canal dentin with an additional touch-polymerization activator has been insufficiently examined. PURPOSE: The purpose of this in vitro study was to investigate the effect of touch-polymerization activators and extended light-irradiation time on the microtensile bond strength (μTBS) of light-activated adhesives. MATERIAL AND METHODS: Post cavities were prepared in 50 extracted mandibular premolars and bonded using Prime&Bond Universal (PBU); PBU+Self Cure Activator (SCA); Clearfil SE Bond 2 (SEB); SEB+Clearfil DC Activator (DCA); or Clearfil Universal Bond Quick ER (UBQ). After light-irradiation for 10 or 20 seconds, the post cavities were filled with dual-activated resin core materials. Eight beams were prepared per specimen and subjected to the μTBS test. The μTBS data were analyzed by using 3-way ANOVAs with the Bonferroni correction (α=.05). RESULTS: The 3-way ANOVAs indicated that the use of touch-polymerization activators (SCA and DCA) significantly increased the μTBS of PBU and SEB in both the coronal (P=.015) and apical (P=.001) regions. The extension of light-irradiation time to 20 seconds significantly improved their μTBS in the apical region (P<.001), but not in the coronal region (P=.09). Light-irradiation for 20 seconds increased the μTBS of UBQ significantly in the coronal region (P=.014). CONCLUSIONS: Touch-polymerization activators improved the bond strength of light-activated adhesives to root canal dentin, especially when combined with an extended light-irradiation time.
Dental composite materials often contain monomers with bisphenol A (BPA) structure in their molecules, e.g. bisphenol-A glycidyl dimethacrylate (Bis-GMA). In this study, it was examined whether dental restorative composites could be a low-dose source of BPA or alternative bisphenols, which are known to have endocrine-disrupting effects. Bis-GMA-containing composites Charisma Classic (CC) and Filtek Ultimate Universal Restorative (FU) and "BPA-free" Charisma Diamond (CD) and Admira Fusion (AF) were examined. Specimens (diameter 6 mm, height 2 mm, n=5) were light-cured from one side for 20 s and stored at 37 °C in methanol which was periodically changed over 130 days to determine the kinetics of BPA release. BPA concentrations were measured using a dansyl chloride derivatization method with liquid chromatography - tandem mass spectrometry detection. The amounts of BPA were expressed in nanograms per gram of composite (ng/g). BPA release from Bis-GMA-containing CC and FU was significantly higher compared to "BPA-free" CD and AF. The highest 1-day release was detected with FU (15.4+/-0.8 ng/g), followed by CC (9.1+/-1.1 ng/g), AF (2.1+/-1.3 ng/g), and CD (1.6+/-0.8 ng/g), and the release gradually decreased over the examined period. Detected values were several orders of magnitude below the tolerable daily intake (4 microg/kg body weight/day). Alternative bisphenols were not detected. BPA was released even from "BPA-free" composites, although in significantly lower amounts than from Bis-GMA-containing composites. Despite incubation in methanol, detected amounts of BPA were substantially lower than current limits suggesting that dental composites should not pose a health risk if adequately polymerized.
- MeSH
- benzhydrylové sloučeniny analýza MeSH
- bisfenol A-glycidyl methakrylát chemie MeSH
- fenoly analýza MeSH
- lidé MeSH
- methakryláty chemie MeSH
- siloxany chemie MeSH
- složené pryskyřice chemie MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- zubní materiály chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Klíčová slova
- GRADIA PLUS,
- MeSH
- dentální adheziva tuhnoucí světlem metody MeSH
- inleje metody MeSH
- inzerce jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- moláry MeSH
- složené pryskyřice chemie terapeutické užití MeSH
- trvalá zubní náhrada metody MeSH
- zubní implantáty jednotlivých zubů * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
OBJECTIVE: To measure the Knoop microhardness at the bottom of four posterior resin-based composites (RBCs): Tetric EvoCeram Bulk Fill (Ivoclar Vivadent), SureFil SDR flow (DENTSPLY), SonicFill (Kerr), and x-tra fil (Voco). METHODS: The RBCs were expressed into metal rings that were 2, 4, or 6-mm thick with a 4-mm internal diameter at 30°C. The uncured specimens were covered by a Mylar strip and a Bluephase 20i (Ivoclar Vivadent) polywave(®) LED light-curing unit was used in high power setting for 20s. The specimens were then removed and placed immediately on a Knoop microhardness-testing device and the microhardness was measured at 9 points across top and bottom surfaces of each specimen. Five specimens were made for each condition. RESULTS: As expected, for each RBC there was no significant difference in the microhardness values at the top of the 2, 4 and 6-mm thick specimens. SureFil SDR Flow was the softest resin, but was the only resin that had no significant difference between the KHN values at the bottom of the 2 and 4-mm (Mixed Model ANOVA p<0.05). Although the KHN of SureFil SDR Flow was only marginally significantly different between the 2 and 6-mm thickness, the bottom at 6-mm was only 59% of the hardness measured at the top. CLINICAL SIGNIFICANCE: This study highlights that clinicians need to consider how the depth of cure was evaluated when determining the depth of cure. SureFil SDR Flow was the softest material and, in accordance with manufacturer's instructions, this RBC should be overlaid with a conventional resin.
- MeSH
- akrylové pryskyřice chemie účinky záření MeSH
- analýza zatížení zubů MeSH
- bisfenol A-glycidyl methakrylát chemie účinky záření MeSH
- dentální adheziva tuhnoucí světlem přístrojové vybavení metody MeSH
- methakryláty chemie účinky záření MeSH
- polymerizace účinky záření MeSH
- polyurethany chemie účinky záření MeSH
- povrchové vlastnosti účinky záření MeSH
- složené pryskyřice chemie účinky záření MeSH
- stomatologické polymerizační lampy * MeSH
- testování materiálů MeSH
- zubní materiály chemie účinky záření MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- MeSH
- lidé MeSH
- nanokompozity * MeSH
- složené pryskyřice chemie terapeutické užití MeSH
- zubní materiály * MeSH
- Check Tag
- lidé MeSH