OBJECTIVES: A simple, cost-effective, and fast gas chromatography method with mass spectrometry detection (GC-MS) for simultaneous measurement of ethylene glycol, 1,2-propylene glycol and glycolic acid was developed and validated for clinical toxicology purposes. DESIGN AND METHODS: Successful derivatization of glycolic acid with isobutyl chloroformate was achieved directly in serum/urine while glycols are simultaneously derivatized by phenylboronic acid. The entire sample preparation procedure is completed within 10 min. RESULTS: The assay was proved to be quadratic in the range of 50 to 5000 mgL(-1) with adequate accuracy (96.3-105.8%) and precision (CV ≤ 8.9%). CONCLUSION: The method was successfully applied to quantify the selected compounds in serum of patients from emergency units and the results correlated well with parallel GC-FID measurements (R(2) 0.9933 for ethylene glycol and 0.9943 for glycolic acid).
- MeSH
- analýza nákladů a výnosů * MeSH
- časové faktory MeSH
- ethylenglykol krev moč MeSH
- glykoláty krev moč MeSH
- lidé MeSH
- náhlé příhody MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí ekonomika metody MeSH
- toxikologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A simple, cost effective, and fast gas chromatography method with mass spectrometry detection (GC-MS) for simultaneous measurement of formic acid, glycolic acid, methoxyacetic acid, ethoxyacetic acid and 2-hydroxyethoxyacetic acid in serum and urine was developed and validated. This multi-analyte method is highly suitable for clinical and emergency toxicology laboratory diagnostic, allowing identification and quantification of five most common acidosis inducing organic acids present in cases of alcohol intoxication. Furthermore, when patients are admitted to emergency unit at late stage of toxic alcohol intoxication, the concentration of parent compound may be already low or not detectable. This new method employs a relatively less used class of derivatization agents - alkyl chloroformates, allowing the efficient and rapid derivatization of carboxylic acids within seconds. The entire sample preparation procedure is completed within 5 min. The optimal conditions of derivatization procedure have been found using chemometric approach (design of experiment). The calibration dependence of the method was proved to be quadratic in the range of 25-3000 mg L(-1), with adequate accuracy (97.3-108.0%) and precision (<12.8%). The method was successfully applied for identification and quantification of the selected compounds in serum of patients from emergency units.
- MeSH
- acetáty krev moč MeSH
- acidóza diagnóza MeSH
- analýza moči metody MeSH
- biochemická analýza krve metody MeSH
- chemické techniky analytické MeSH
- formiáty krev moč MeSH
- glykoláty krev moč MeSH
- kalibrace MeSH
- lidé MeSH
- limita detekce MeSH
- otrava alkoholem krev moč MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí metody MeSH
- reprodukovatelnost výsledků MeSH
- toxikologie metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A simple, cost effective, and fast gas chromatography method with flame ionization detection (GC-FID) for simultaneous measurement of ethylene glycol, 1,2-propylene glycol and glycolic acid was developed and validated for clinical toxicology purposes. This new method employs a relatively less used class of derivatization agents - alkyl chloroformates, allowing the efficient and rapid derivatization of carboxylic acids within seconds while glycols are simultaneously derivatized by phenylboronic acid. The entire sample preparation procedure is completed within 10 min. To avoid possible interference from naturally occurring endogenous acids and quantitation errors 3-(4-chlorophenyl) propionic acid was chosen as an internal standard. The significant parameters of the derivatization have been found using chemometric procedures and these parameters were optimized using the face-centered central composite design. The calibration dependence of the method was proved to be quadratic in the range of 50-5000 mg mL(-1), with adequate accuracy (92.4-108.7%) and precision (9.4%). The method was successfully applied to quantify the selected compounds in serum of patients from emergency units.
- MeSH
- chromatografie plynová metody MeSH
- ethylenglykol krev otrava moč MeSH
- glykoláty krev otrava moč MeSH
- lidé MeSH
- plamínková ionizace metody MeSH
- propylenglykol krev otrava moč MeSH
- sérum chemie MeSH
- studie případů a kontrol MeSH
- toxikologie metody MeSH
- urgentní zdravotnické služby * MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Ethylene glycol monobutyl ether (EGBE), an industrial solvent, is absorbed by the body not only by inhalation but also by dermal absorption (liquid or vapour). EGBE is metabolized to butoxyacetic acid (BAA). Pooled freeze-dried urine candidate reference material (RM) was prepared from urine obtained from persons occupationally exposed to EGBE. This material has the advantage of containing butoxyacetic acid in both the free and conjugated (glutamine and glycine) forms, as found in native urine. In all GC method modifications used, acid hydrolysis was used to release BAA from its conjugated form. The amount of butoxyacetic acid in homogeneity and stability testing was measured by GC after derivatisation with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. Detection was by MS in EI mode, in the authors' laboratory. For interlaboratory comparison of the reference material GC methods with MS, FID, and ECD were used. Different extraction solvents (dichloromethane-isopropanol 2:1, ethyl acetate, or dichloromethane) and derivatisation reagents (trimethylsilyldiazomethane, N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) were used. Using ANOVA (at the statistical level alpha = 0.05) no changes were found in the concentration of butoxyacetic acid during fifteen month isochronous stability testing, or in homogeneity testing. The uncertainty contributions were u (h) = 8.8 mg L(-1) and u (s) = 6.5 mg L(-1). The concentration of butoxyacetic acid in freeze-dried urine RM was evaluated from the results of eight laboratory data sets within an interlaboratory comparison by use of the interactive statistical software IPECA. The contribution to total uncertainty derived from interlaboratory comparison was u (i) = 12.7 mg L(-1). The reference value (c = 273 +/- 33 mg L(-1)) is an unweighted arithmetic average of accepted results. The value is traceable to the pure butoxyacetic acid (98% w/w; Acros Organic #257760010) used as calibrant. The uncertainty given is combined expanded uncertainty derived from the results from interlaboratory comparison, and from homogeneity and stability tests (k = 2). The reference material will be used to verify method performance in the biological monitoring of occupational exposure to EGBE.
- MeSH
- ethylenglykoly metabolismus MeSH
- glykoláty normy moč MeSH
- lidé MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí metody MeSH
- pracovní expozice MeSH
- referenční standardy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH