"Medical Diagnostics"
Dotaz
Zobrazit nápovědu
OBJECTIVES: To assess the diagnostic performance and interobserver agreement of CT pulmonary angiography (CTPA) in the detection of chronic thromboembolic pulmonary hypertension (CTEPH) and its features among radiologists of different levels of experience. MATERIALS AND METHODS: In this retrospective, single-center, single-blinded study, three radiologists with different levels of experience in CT imaging (R1:15 years, R2:6 years, and R3:3 years) evaluated CTPA of 51 patients ultimately diagnosed with CTEPH (European Society of Cardiology guidelines) and 49 patients without CTEPH in random order to assess the presence of CTEPH, its features in the pulmonary artery tree, proximal level of involvement, bronchial artery hypertrophy, mosaic perfusion, and right heart overload. RESULTS: CTPAs of 51 patients with CTEPH (median age, 66 years (IQR 56-72), 28 men) and 49 patients without CTEPH (median age, 65 years (IQR 50-74), 25 men) were evaluated. The sensitivity and specificity for the detection of CTEPH was 100% (all radiologists) and 100% (R1), 96% (R2), and 96% (R3) with almost perfect agreement (κ = 0.95). The sensitivity and specificity for detecting CTEPH by mosaic perfusion would be 89% (95%CI 83-93%) and 81% (74-87%). The level of pulmonary artery involvement was reported with moderate agreement (κ = 0.54, 95%CI 0.40-0.65). Substantial agreement was found in the evaluation of mosaic attenuation (κ = 0.75, 95%CI 0.64-0.84), right heart overload (κ = 0.68, 95%CI 0.56-0.79), and bronchial artery hypertrophy (0.71, 95%CI 0.59-0.82) which were the best predictors of CTEPH (p < 0.0001). CONCLUSIONS: CTPA has high sensitivity and specificity in detecting CTEPH and almost perfect agreement among radiologists of different levels of expertise. CLINICAL RELEVANCE: CT pulmonary angiography can be used as a first-line imaging modality in patients with suspected chronic thromboembolic pulmonary hypertension (CTEPH) even when interpreted by non-CTEPH experts. KEY POINTS: • CT pulmonary angiography has high sensitivity and specificity in detecting chronic thromboembolic pulmonary hypertension (CTEPH) and almost perfect interobserver agreement among radiologists of different levels of expertise. • Substantial agreement exists in the assessment of mosaic attenuation, right heart overload, and bronchial artery hypertrophy, which are the best predictors of CTEPH.
- MeSH
- angiografie metody MeSH
- chronická nemoc MeSH
- hypertrofie MeSH
- jednoduchá slepá metoda MeSH
- lidé středního věku MeSH
- lidé MeSH
- plicní embolie * komplikace diagnostické zobrazování MeSH
- plicní hypertenze * komplikace diagnostické zobrazování MeSH
- počítačová rentgenová tomografie metody MeSH
- retrospektivní studie MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: To quantify extraprostatic findings (EPFs) on prostate MRI, estimate the proportion of reported and unreported EPFs, assess their clinical importance, and propose standardized reporting of EPFs. MATERIALS AND METHODS: Prostate 3-T MRI studies, reports, and clinical data from 623 patients (age 67.9 ± 8.2 years) were retrospectively analyzed and re-evaluated for the presence of EPFs and their clinical significance: E1-no finding or findings that have no clinical significance; E2-potentially significant findings; and E3-significant findings. RESULTS: Secondary reading identified 1236 EPFs in 593 patients (1.98 ± 1.13 EPFs per patient, no EPFs in 30 patients), from which 468 (37.8%) were mentioned in the original report. The most common findings included diverticulosis (44% of patients), hydrocele (34%), inguinal fat hernia (16%), and bladder wall trabecular hypertrophy (15%). There were 80 (6.5%) E2 EPFs and 30 (2.4%) E3 EPFs. From E3 EPFs, 10 (33%) were not originally reported. A workup was suggested in 35 (52%) of the 67 originally reported E2 and E3 findings with follow-up and performed in 20 (30%). Fourteen (21%) EPFs in 11 patients influenced their management. Four experienced radiologists originally reported 1.8 to 2.5 findings per patient (p < 0.0001). CONCLUSIONS: EPFs on prostate MRI are frequent, but only 2.4% are clinically significant (E3), and 33% of these are not reported. Only 30% of E2 and E3 findings are further explored, and 21% influence patient management. We suggest that an "E" category should be attached to the PI-RADS system to identify the presence of EPFs that require further workup. CRITICAL RELEVANCE STATEMENT: Extraprostatic findings on prostate MRI are frequent, but only 2.4% are clinically significant (E3), and 33% of these are not reported. We advocate standardized reporting of extraprostatic findings indicating their clinical significance. KEY POINTS: • Extraprostatic findings on prostate MRI are frequent with an average of two findings per patient. • 2.4% of extraprostatic findings are significant, and 33% of these are not reported. • There is a significant variability among experienced radiologists in reporting extraprostatic findings.
- Publikační typ
- časopisecké články MeSH
This study aimed to evaluate the efficacy of cryopreserved amniotic membrane (AM) grafts in chronic wound healing, including the mean percentage of wound closure per one AM application, and to determine whether the healing efficiency differs between AM grafts obtained from different placentas. A retrospective study analyzing inter-placental differences in healing capacity and mean wound closure after the application of 96 AM grafts prepared from nine placentas. Only the placentas from which the AM grafts were applied to patients suffering from long-lasting non-healing wounds successfully healed by AM treatment were included. The data from the rapidly progressing wound-closure phase (p-phase) were analyzed. The mean efficiency for each placenta, expressed as an average of wound area reduction (%) seven days after the AM application (baseline, 100%), was calculated from at least 10 applications. No statistical difference between the nine placentas' efficiency was found in the progressive phase of wound healing. The 7-day average wound reduction in particular placentas varied from 5.70 to 20.99% (median from 1.07 to 17.75) of the baseline. The mean percentage of wound surface reduction of all analyzed defects one week after the application of cryopreserved AM graft was 12.17 ± 20.12% (average ± SD). No significant difference in healing capacity was observed between the nine placentas. The data suggest that if there are intra- and inter-placental differences in AM sheets' healing efficacy, they are overridden by the actual health status of the subject or even the status of its individual wounds.
- MeSH
- amnion * transplantace MeSH
- hojení ran MeSH
- kryoprezervace MeSH
- lidé MeSH
- placenta * MeSH
- retrospektivní studie MeSH
- těhotenství MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
This article explores the development and application of innovative piezoelectric sensors in point-of-care diagnostics. It highlights the significance of bedside tests, such as lateral flow and electrochemical tests, in providing rapid and accurate results directly at the patient's location. This paper delves into the principles of piezoelectric assays, emphasizing their ability to detect disease-related biomarkers through mechanical stress-induced electrical signals. Various applications of piezoelectric chemosensors and biosensors are discussed, including their use in the detection of cancer biomarkers, pathogens, and other health-related analytes. This article also addresses the integration of piezoelectric materials with advanced sensing technologies to improve diagnostic accuracy and efficiency, offering a comprehensive overview of current advances and future directions in medical diagnostics.
- MeSH
- biologické markery analýza MeSH
- biosenzitivní techniky * MeSH
- elektrochemické techniky MeSH
- lidé MeSH
- vyšetření u lůžka MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
This paper covers a brief review of both the advantages and disadvantages of the implementation of various smoothing filters in the analysis of electroencephalography (EEG) data for the purpose of potential medical diagnostics. The EEG data are very prone to the occurrence of various internal and external artifacts and signal distortions. In this paper, three types of smoothing filters were compared: smooth filter, median filter and Savitzky-Golay filter. The authors of this paper compared those filters and proved their usefulness, as they made the analyzed data more legible for diagnostic purposes. The obtained results were promising, however, the studies on finding perfect filtering methods are still in progress.
- MeSH
- algoritmy MeSH
- artefakty MeSH
- dospělí MeSH
- elektroencefalografie metody MeSH
- filtrace MeSH
- lidé MeSH
- mladý dospělý MeSH
- mozek diagnostické zobrazování fyziologie MeSH
- počítačové zpracování signálu přístrojové vybavení MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Data Analytics provides various methods and approaches to extract hidden and poten-tially useful knowledge for different purposes. It means that we can use this knowledge for decision support, e.g. to identify crucial inputs and relations, to predict some future state, to confirm or reject our hypothesis. The medical diagnostics deals with all the mentioned tasks to provide a right diagnosis for the patient and to ensure the effective diagnostic process. In this paper, we briefly describe some of our activi-ties oriented to support medical diagnostics by means of Data Analytics approaches; we selected only key points here, more details can be found in our previously pub-lished articles.