Square wave voltammetry
Dotaz
Zobrazit nápovědu
The pungency of chili peppers, the most popular hot spice used worldwide, is caused by capsaicinoids (CPDs), the content of which can vary greatly due to varietal differences and growing conditions. For the first time, a novel simple method for the fast determination of CPDs in chili peppers and chili products was developed based on adsorptive transfer cyclic square-wave voltammetry (AdTCSWV), using adsorption of lipophilic CPDs on an unmodified glassy carbon electrode surface from methanolic extracts of chili pepper samples. The CSWV is based on short oxidation of adsorbed CPDs to quinoid products, and their subsequent reduction and re-oxidation to provide specific analytical signals with a linear range from 0.05 to 1.00 mg L-1. This principle was also implemented in tandem coulometric and amperometric detection of CPDs after HPLC separation. The two-step electrochemical detection provides increased selectivity for CPDs in case of CPDs co-elution with other electrochemically oxidizable components that cannot be reversibly reduced.
The analytical performance of the clay paste electrode and graphene paste electrode was compared using square wave voltammetry (SWV) and cyclic voltammetry (CV). The comparison was made on the basis of a paracetamol (PA) determination on both working electrodes. The influence of pH and SWV parameters was investigated. The linear concentration ranges were found to be 6.0 × 10-7-3.0 × 10-5 and 2.0 × 10-6-8.0 × 10-5 mol L-1 for clay paste electrode (ClPE) and graphene paste electrode (GrPE), respectively. The detection and quantification limits were calculated as 1.4 × 10-7 and 4.7 ×10-7 mol L-1 for ClPE and 3.7 × 10-7 and 1.2 × 10-6 mol L-1 for GrPE, respectively. Developed methods were successfully applied to pharmaceutical formulations analyses. Scanning electron microscopy and energy-dispersive X-ray spectroscopy were used to characterize ClPE and GrPE surfaces. Clay composition was examined with wavelength dispersive X-ray (WDXRF).
Highly stable, small-sized and evenly distributed solid mercury nanoparticles capped with ibuprofen (Ibu-HgNPs) were prepared via reduction with hydrazine and capped with ibuprofen as a stabilizing agent. Characterization of Ibu-HgNPs was carried out by UV-Vis spectrophotometry and transmission electron microscopy (TEM). The prepared Ibu-HgNPs were immobilized onto a glassy carbon electrode (GCE) and used for the first time as the sensing element for voltammetric determination of low concentrations of acrylamide (AA) in aqueous solutions. Various parameters such as the type of supporting electrolyte, voltammetric mode, frequency, deposition time, stirring rate and initial potential were optimized to obtain the highest peak current of AA. The sensor delivered the best results in combination with the square wave voltammetry (SWV) mode, with good repeatability (relative standard deviation (RSD) of 25 repetitions was 1.4% for 1000 ppb AA). The study further revealed that Ibu-HgNPs are strongly adhered to GCE and hence do not contaminate the environment even after several runs. The newly developed AA sensor provides linear calibration dependence in the range of 100-1300 ppb with an R2 value of 0.996 and limit of detection (LOD) of 8.5 ppb. Negligible interference was confirmed from several organic compounds, cations and anions. The developed sensor was successfully applied for AA determination in various types of environmental real water samples to prove its practical usefulness and applicability.
- MeSH
- akrylamid MeSH
- elektrochemické techniky MeSH
- elektrody MeSH
- ibuprofen MeSH
- nanočástice * MeSH
- rtuť * MeSH
- Publikační typ
- časopisecké články MeSH
Novel porous boron-doped diamond (BDDporous)-based materials have attracted lots of research interest due to their enhanced detection ability and biocompatibility, favouring them for use in neuroscience. This study reports on morphological, spectral, and electrochemical characterisation of three BDDporous electrodes of different thickness given by a number of deposited layers (2, 3 and 5). These were prepared using microwave plasma-enhanced chemical vapour deposition on SiO2 nanofiber-based scaffolds. Further, the effect of number of layers and poly-l-lysine coating, commonly employed in neuron cultivation experiments, on sensing properties of the neurotransmitter dopamine in a pH 7.4 phosphate buffer media was investigated. The boron doping level of ∼2 × 1021 atoms cm-3 and increased content of non-diamond (sp2) carbon in electrodes with more layers was evaluated by Raman spectroscopy. Cyclic voltammetric experiments revealed reduced working potential windows (from 2.4 V to 2.2 V), higher double-layer capacitance values (from 405 μF cm-2 to 1060 μF cm-2), enhanced rates of electron transfer kinetics and larger effective surface areas (from 5.04 mm2 to 7.72 mm2), when the number of porous layers increases. For dopamine, a significant boost in analytical performance was recognized with increasing number of layers using square-wave voltammetry: the highest sensitivity of 574.1 μA μmol-1 L was achieved on a BDDporous electrode with five layers and dropped to 35.9 μA μmol-1 L when the number of layers decreased to two. Consequently, the lowest detection limit of 0.20 μmol L-1 was obtained on a BDDporous electrode with five layers. Moreover, on porous electrodes, enhanced selectivity for dopamine detection in the presence of ascorbic acid and uric acid was demonstrated. The application of poly-l-lysine coating on porous electrode surface resulted in a decrease in dopamine peak currents by 17% and 60% for modification times of 1 h and 15 h, respectively. Hence, both examined parameters, the number of deposited porous layers and the presence of poly-l-lysine coating, were proved to considerably affect the characteristics and performance of BDDporous electrodes.
Significant improvements in the voltammetric determination of β-carotene (BCA) have been achieved, mainly by the replacement of toxic dichloromethane with acetone and using non-mercury electrode. The respective procedure is based on anodic oxidation of BCA at a gold electrode in the disc configuration, when using square-wave voltammetry in pure acetone (99.8%) with 0.1 mol L-1 LiClO4 as the supporting electrolyte. The method comprises extraction of the analyte from the sample with acetone, thus avoiding the usually used highly toxic solvents. Analytically, it can be characterized by a linear range from 6.0 × 10-6 to 5.9 × 10-4 mol L-1 with regression equation Ipa = 0.0184c -0.1631 and correlation coefficient, R2 = 0.9998, limits of detection and quantification LOD = 1.6 × 10-6 mol L-1 and LOQ = 5.4 × 10-6 mol L-1, respectively; both being obtained at a potential step of 5 mV, with the pulse amplitude of 25 mV, and a frequency of 80 Hz. After optimization, the method was evaluated in series of analyses; namely, with two samples of vegetables and two pharmaceutical preparations (capsules), when the results could be compared to those of a reference spectrophotometric method. Due to a simple instrumentation, including sample preparation, the voltammetric method for the determination of BCA can be recommended as a quick screening assay in food and pharmaceutical analysis.
- MeSH
- beta-karoten MeSH
- elektrochemie MeSH
- elektrody MeSH
- tobolky MeSH
- zelenina * MeSH
- zlato * MeSH
- Publikační typ
- časopisecké články MeSH
A new electroanalytical methodology was developed for the sensitive and selective determination of formaldehyde in wood-based products (WBPs), featuring an extraction process using a Headspace Liquid Acceptor System (HLAS), and detection by square-wave voltammetry (SWV) on unmodified screen-printed carbon electrodes (SPCEs). HLAS, here presented for the first time, captures and derivatizes formaldehyde released from the sample by using the acetylacetone reagent as acceptor solution. The product of formaldehyde with acetylacetone, in the presence of ammonium salt, is 3,5-diacetyl-1,4-dihydrolutidine (DDL) which we have found to be electrochemically active at unmodified SPCEs, generating a selective oxidation peak at +0.4 V. Detection and quantification limits of 0.57 and 1.89 mg kg-1 were obtained, together with intra- and inter-day precisions below 10% (as relative standard deviation, RSD). The methodology was used to determine formaldehyde content in seven WBPs, with similar results being obtained by the developed HLAS-SPCE method and the European standard method EN 717-3, with a profound reduction of total analysis time. The developed HLAS-SPCE combines the use of a new sample preparation procedure for volatiles with, as far as we know, the first determination of formaldehyde (as the derivative product, DDL) on unmodified SPCEs, offering a promising alternative for the determination of formaldehyde in WBPs and other samples.
- Publikační typ
- časopisecké články MeSH
Compounds containing vicinal diol (glycol) groups, including saccharides, could be modified with sixvalent osmium complexes with nitrogenous ligands, particularly with N,N,N',N'-tetramethylethylenediamine (Os(VI)tem). The modification products are electrochemically active. Here we show that aminosaccharides can also be modified by Os(VI)tem. We studied chitosan oligosaccharides in their acetylated and deacetylated form in 0.2 M Na-phosphate, pH 6.9. Deacetylated chitosan oligosaccharides with free amino groups modified by Os(VI)tem yielded two peaks (peak I' at -0.15 V and peak II' at about -0.38 V) despite the fact that these oligomers contain only one glycol group on the non-reducing end of the molecule. The electrochemical behavior of Os(VI)tem modified deacetylated chitosan oligomers differs from Os(VI)tem modified simple saccharides, containing only glycol groups, predominantly in peak I'. Our results suggest that free amino groups are involved in Os(VI)tem modification of chitosan oligomers.
Haemophilus Influenza leads to respiratory infections such as sinusitis, acute otitis media, pneumonia and bronchitis. In addition, it causes invasive infections such as cellulite, septic arthritis, and meningitis. Therefore, quick and sensitive detection of H. influenza is of great importance in medical microbiology. In this study, a novel DNA-based bioassay was developed to the monitoring of Haemophilus influenza genome in human plasma samples using binding of pDNA with cDNA. DNA hybridization strategy was used to investigation of DNAs binding. For this purpose, silver nanoparticle doped graphene quantum dots inks functionalized by D-penicillamine (Ag NPs-DPA-GQDs) were synthesized and deposited on the surface of glass carbon electrode (GCE). Also, gold nanoparticles functionalized with cysteamine (CysA-AuNPs) were deposited on the surface of the Ag-DPA-GQDs modified GCE. Afterward, thiolated DNA probe was immobilized on the surface of the modified electrode. DNA hybridization was monitored using square wave voltammetry (SWV) technique. Engineered genosensor indicated good performance with high specificity and sensitivity for detection of Haemophilus influenza genome. Under optimal conditions, linear range and low limit of quantitation (LLOQ) were obtained as target concentrations ranging from 1 pM-1 ZM and 1 ZM, respectively. The designed biosensor also showed high capability of discriminating one-base, two-base and three-base mismatched sequences. Also, the prepared genosensor could be easily regenerated and reused to evaluate hybridization process.
- MeSH
- biosenzitivní techniky MeSH
- elektrochemické techniky MeSH
- genom bakteriální * MeSH
- Haemophilus influenzae genetika MeSH
- hybridizace nukleových kyselin metody MeSH
- komplementární DNA * MeSH
- kovové nanočástice ultrastruktura MeSH
- kvantové tečky MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- volné cirkulující nukleové kyseliny * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
A novel sensor based on a modification of glassy carbon electrode (GCE) with NH2-functionalized multi-walled carbon nano-tubes (NH2fMWCNTs) is reported and its applicability to the electrochemical sensing of Propafenone (PPF) demonstrated. The electrochemical catalytic activity was also utilized as a sensitive detection method for the investigation of the detailed redox mechanism of PFF using cyclic and and differential pulse voltammetry. The surface morphology of the sensor was investigated by SEM armed with EDX probe. Electrochemical impedance spectroscopy was employed as well to define the electron transfer capability of modified and bare electrodes. Key experimental and instrumental conditions related to electrochemical determination by cyclic, differential pulse, and square wave voltammetry, such as amount of modifier, pH, scan rate, accumulation time and potential were studied and optimized. The results have shown a significant enhancement of the peak current after modifying the electrode; the calibration curves of PPF offering good linearity from 0.1 to 10 μM, limit of quantification (LOQ) being 0.03 μM and limit of detection (LOD) 0.01 μM, both when using DPV technique. The proposed sensor was successfully applied to the determination of PFF in dosage form without any special purification, separation or pre-treatment steps. The results of analyses obtained with the proposed sensor were satisfactory and fully statistically relevant.
- MeSH
- antiarytmika MeSH
- elektrody MeSH
- farmaceutická technologie přístrojové vybavení metody MeSH
- impedanční spektroskopie MeSH
- kalibrace MeSH
- koncentrace vodíkových iontů MeSH
- kyslík chemie MeSH
- lékové formy * MeSH
- limita detekce MeSH
- mikroskopie elektronová rastrovací MeSH
- nanomedicína MeSH
- nanotrubičky uhlíkové chemie MeSH
- propafenon aplikace a dávkování MeSH
- uhlík chemie MeSH
- Publikační typ
- časopisecké články MeSH
A completely new voltammetric method has been developed for quantitative determination of food additive Taurine (Tau) in energy drinks. This electroanalytical method is based on voltammetric oxidation of o-phthalaldehyde-ethanthiol derivative of Tau at glassy carbon electrode in 95% methanol containing 0.1 mol L-1 lithium perchlorate. Working conditions necessary for quantitative Tau derivatization reaction and electrochemical detection using square wave voltammetry were optimized. Linear range from 1.0 × 10-5 to 1.0 × 10-4 mol L-1 characterized by coefficient of determination 0.9998, limits of quantification 6.8 × 10-6 mol L-1 and detection 2.1 × 10-6 mol L-1 were obtained at pulse amplitude 50 mV and frequency 80 Hz. Analytical method of calibration curve was used for evaluation of Tau content in several commercially available energy drinks. The procedure was validated using standard reference high performance liquid chromatography (HPLC) method. Both methods showed nearly identical Tau content, around 0.35% (w/w). Besides its reliability to the Tau determination, that is totally comparable to reference method used, present voltammetric approach is more advantageous on the economic and simplicity basis. Finally, developed voltammetric method could find employment in food quality control.