The present paper is an extension to our earlier publication (Šochman et al. 2016) documenting a beneficial effect of renal sympathetic denervation on pharmacologically uncontrollable hypertension in a group of seven patients followed up for 1-2 years post-procedure. The same patients remained on ambulatory follow-up for another 5-6 years, with the beneficial effect persisting throughout the follow-up period while on the same medication.
- MeSH
- antihypertenziva terapeutické užití MeSH
- hypertenze diagnóza farmakoterapie chirurgie MeSH
- krevní tlak fyziologie MeSH
- ledviny inervace fyziologie chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- senioři MeSH
- sympatektomie trendy MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The concept of vena contracta space reduction in tricuspid valve position was tested in an animal model. Feasibility of specific artificial obturator body (REMOT) fixed to the right ventricular apex and interacting with tricuspid valve leaflets was evaluated in three different animal studies. Catheter-based technique was used in three series of experiment in 7 sheep. First acute study was designed for evaluation if the screwing mode of guide wire anchoring to the right ventricular apex is feasible for the whole REMOT body fixing. Longer study was aimed to evaluate stability of the REMOT body in desired position when fixing the screwing wire on its both ends (to the right ventricular apex and to the skin in the neck area). X-ray methods and various morphological methods were used. The third acute study was intended to the REMOT body deployment without any fixing wire. In all of 7 sheep the REMOT was successfully inserted into the right heart cavities and then fixed to the right ventricular apex area. When the REMOT was left in situ more than 6 months it was stable, induced adhesion to the tricuspid valve leaflet and was associated with a specific cell invasion. Releasing of the REMOT from the guiding tools was also successfully verified. Deployment of the obturator body in the aim to reduce the tricuspid valve orifice is feasible and well tolerated in the short and longer term animal model. Specific cell colonization including neovascularization of the obturator body was observed.
- MeSH
- chirurgická náhrada chlopně metody MeSH
- ovce MeSH
- pilotní projekty MeSH
- studie proveditelnosti MeSH
- trikuspidální chlopeň patologie chirurgie MeSH
- trikuspidální insuficience patologie chirurgie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
AIMS: The objective of this study was to compare long-term clinical effects of biventricular pacing with isolated left ventricular pacing. METHODS AND RESULTS: Forty consecutive patients with idiopathic dilated cardiomyopathy and indication for cardiac resynchronization therapy were randomized to biventricular or isolated left ventricular pacing. Clinical and echocardiographic parameters were studied regularly prior to implantation and during 1 year of follow-up. Patients with atrial fibrillation were excluded from the study. A retrospective cross-sectional outcome analysis was performed 4 years after the beginning of the study. Biventricular pacing was associated with more pronounced clinical and echocardiographic benefit compared with left ventricular pacing. Biventricular pacing was associated with significantly more distinct reverse remodelling. Left ventricular ejection fraction improved by 12.5 per cent-points (95% CI 7.3-17.7) compared with 5.1 per cent-points (95% CI 1.1-9.2) (P = 0.01) and left ventricular end-diastolic diameter decreased by 8.69 mm (95% CI 5.2-12.2) compared with 5.1 mm (95% CI 1.5-8.7) (P = 0.05) in the biventricular and left-ventricular pacing group, respectively. Semi-quantitative summarization of response points revealed a greater benefit in the biventricular vs. left ventricular pacing group [mean sum of response points 3.25 (95% CI 2.62-3.88) vs. 2.35 (95% CI 1.74-2.96), respectively, P = 0.06]. After 3 years of follow-up, there was no cardiovascular death in the biventricular pacing group compared with three cardiovascular deaths in the left ventricular pacing group. CONCLUSION: In patients with idiopathic dilated cardiomyopathy, biventricular pacing is associated with significantly more pronounced benefit in clinical outcomes and reverse remodelling. A retrospective analysis after 3 years of follow-up suggests that isolated left ventricular pacing may be associated with a higher mortality rate compared with biventricular pacing.
- MeSH
- dilatační kardiomyopatie mortalita patofyziologie terapie MeSH
- echokardiografie MeSH
- elektrokardiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- míra přežití MeSH
- následné studie MeSH
- průřezové studie MeSH
- retrospektivní studie MeSH
- senioři MeSH
- srdeční komory patofyziologie ultrasonografie MeSH
- srdeční resynchronizační terapie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
Efforts to modify cardiac valve defects using catheter-based techniques are increasing at the present time. We present observations on cardiac valve morphology and disease and review the progress being made to address valve defects with these innovative methods. Some new procedures developed through animal experimentation have already been put to use in clinical practice, but the newness of these techniques and the small number of cases in which they have been applied to date precludes an evaluation of their long-term durability. Although at the present time cardiac surgery remains the standard for treating most cases of valve disease, in certain situations a catheter-based treatment might provide a reasonable alternative, even if only temporary, especially for individuals with serious disease who are not suitable candidates for surgery.
- MeSH
- aortální chlopeň MeSH
- arteria pulmonalis MeSH
- chirurgická náhrada chlopně metody MeSH
- financování organizované MeSH
- katetrizační ablace metody MeSH
- lidé MeSH
- mitrální chlopeň MeSH
- modely kardiovaskulární MeSH
- nemoci srdečních chlopní chirurgie terapie MeSH
- plicní chlopeň MeSH
- protézy - design MeSH
- srdeční chlopně umělé MeSH
- trikuspidální chlopeň MeSH
- výsledek terapie MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- zvířata MeSH
- Publikační typ
- přehledy MeSH