OBJECTIVE: Approximately 3.4% of adults aged >75 years suffer from aortic stenosis (AS). Guideline indications for aortic valve replacement (AVR) distinguish between patients with symptomatic and asymptomatic severe AS. The present analysis aims to assess contemporary practice in the treatment of severe AS across Europe and identify characteristics associated with treatment decisions, namely denial of AVR in symptomatic patients and assignment of asymptomatic patients to AVR. METHODS: Participants of the prospective, multinational IMPULSE database of patients with severe AS were grouped according to AS symptoms, and stratified into subgroups based on assignment to/denial of AVR. RESULTS: Of 1608 symptomatic patients, 23.8% did not undergo AVR and underwent medical treatment. Denial was independently associated with multiple factors, including severe frailty (p=0.024); mitral (p=0.002) or tricuspid (p=0.004) regurgitation grade III/IV, and the presence of renal impairment (p=0.017). Of 392 asymptomatic patients, 86.5% had no prespecified indication for AVR. Regardless, 36.3% were assigned to valve replacement. Those with an indexed aortic valve area (AVA; p=0.045) or left ventricular ejection fraction (LVEF; p<0.001) below the study median; or with a left ventricular end systolic diameter above the study median (p=0.007) were more likely to be assigned to AVR. CONCLUSIONS: There may be considerable discrepancies between guideline-based recommendations and clinical practice decision-making in the treatment of AS. It appears that guidelines may not fully capture the complete clinical spectrum of patients with AS. Thus, there is a need to find ways to increase their acceptance and the rate of adoption.
- MeSH
- aortální stenóza diagnóza chirurgie MeSH
- echokardiografie MeSH
- kvalita zdravotní péče * MeSH
- lidé MeSH
- management nemoci * MeSH
- následné studie MeSH
- prospektivní studie MeSH
- senioři MeSH
- směrnice pro lékařskou praxi jako téma * MeSH
- stupeň závažnosti nemoci MeSH
- transkatetrální implantace aortální chlopně normy MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
AIMS: There is an increasing awareness of gender-related differences in patients with severe aortic stenosis and their outcomes after surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI). METHODS: Data from the IMPULSE registry were analysed. Patients with severe aortic stenosis (AS) were enrolled between March 2015 and April 2017 and stratified by gender. A subgroup analysis was performed to assess the impact of age. RESULTS: Overall, 2171 patients were enrolled, and 48.0% were female. Women were characterised by a higher rate of renal impairment (31.7 vs 23.3%; p<0.001), were at higher surgical risk (EuroSCORE II: 4.5 vs 3.6%; p=0.001) and more often in a critical preoperative state (7.0vs 4.2%; p=0.003). Men had an increased rate of previous cardiac surgery (9.4 vs 4.7%; p<0.001) and a reduced left ventricular ejection fraction (4.9 vs 1.3%; p<0.001). Concomitant mitral and tricuspid valve disease was substantially more common among women. Symptoms were highly prevalent in both women and men (83.6 vs 77.3%; p<0.001). AVR was planned in 1379 cases. Women were more frequently scheduled to undergo TAVI (49.3 vs 41.0%; p<0.001) and less frequently for SAVR (20.3 vs 27.5%; p<0.001). CONCLUSIONS: The present data show that female patients with severe AS have a distinct patient profile and are managed in a different way to males. Gender-based differences in the management of patients with severe AS need to be taken into account more systematically to improve outcomes, especially for women.
- MeSH
- aortální chlopeň chirurgie MeSH
- aortální stenóza epidemiologie chirurgie MeSH
- časové faktory MeSH
- hodnocení rizik metody MeSH
- incidence MeSH
- lidé MeSH
- následné studie MeSH
- registrace * MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sexuální faktory MeSH
- srdeční chlopně umělé * MeSH
- stupeň závažnosti nemoci MeSH
- transkatetrální implantace aortální chlopně metody MeSH
- věkové faktory MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: Contemporary data regarding the impact of comorbidities on the clinical presentation and management of patients with severe aortic stenosis (AS) are scarce. METHODS: Prospective registry of severe patients with AS across 23 centres in nine European countries. RESULTS: Of the 2171 patients, chronic kidney disease (CKD 27.3%), left ventricular ejection fraction (LVEF) <50% (22.0%), atrial fibrillation (15.9%) and chronic obstructive pulmonary disease (11.4%) were the most prevalent comorbidities (49.3% none, 33.9% one and 16.8% ≥2 of these). The decision to perform aortic valve replacement (AVR) was taken in a comparable proportion (67%, 72% and 69%, in patients with 0, 1 and ≥2 comorbidities; p=0.186). However, the decision for TAVI was more common with more comorbidities (35.4%, 54.0% and 57.0% for no, 1 and ≥2; p<0.001), while the decision for surgical AVR (SAVR) was decreased with increasing comorbidity burden (31.9%, 17.4% and 12.3%; p<0.001). The proportion of patients with planned AVRs that were performed within 3 months was significantly higher in patients with 1 or ≥2 comorbidities than in those without (8.7%, 10.0% and 15.7%; p<0.001). Furthermore, the mean time to AVR was significantly shorter in patients with one (30.5 days) or ≥2 comorbidities (30.8 days) than in those without (35.7 days; p=0.012). Patients with reduced LVEF tended to be offered an AVR more frequently and with a shorter delay while patients with CKD were less frequently treated. CONCLUSIONS: Comorbidities in severe patients with AS affect the presentation and management of patients with severe AS. TAVI was offered more often than SAVR and performed within a shorter time period.
- MeSH
- aortální stenóza epidemiologie patofyziologie chirurgie MeSH
- čas zasáhnout při rozvinutí nemoci trendy MeSH
- časové faktory MeSH
- chirurgická náhrada chlopně trendy MeSH
- chronická obstrukční plicní nemoc epidemiologie MeSH
- chronická renální insuficience epidemiologie MeSH
- fibrilace síní epidemiologie MeSH
- funkce levé komory srdeční MeSH
- hodnocení rizik MeSH
- klinické rozhodování MeSH
- komorbidita MeSH
- lidé MeSH
- prevalence MeSH
- prospektivní studie MeSH
- registrace MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- tepový objem MeSH
- transkatetrální implantace aortální chlopně trendy MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
Background Many patients with severe aortic stenosis are referred late with advanced symptoms or inappropriately denied intervention. The objective was to investigate whether a structured communication to referring physicians (facilitated data relay) might improve the rate and timeliness of intervention. Methods and Results A prospective registry of consecutive patients with severe aortic stenosis at 23 centers in 9 European countries with transcatheter as well as surgical aortic valve replacement being available was performed. The study included a 3-month documentation of the status quo (phase A), a 6-month intervention phase (implementing facilitated data relay), and a 3-month documentation of a legacy effect (phase-B). Two thousand one hundred seventy-one patients with severe aortic stenoses were enrolled (phase A: 759; intervention: 905; phase-B: 507). Mean age was 77.9±10.0 years, and 80% were symptomatic, including 52% with severe symptoms. During phase A, intervention was planned in 464/696 (67%), 138 (20%) were assigned to watchful waiting, 8 (1%) to balloon aortic valvuloplasty, 60 (9%) were listed as not for active treatment, and in 26 (4%), no decision was made. Three hundred sixty-three of 464 (78%) patients received the planned intervention within 3 months. Timeliness of the intervention improved as shown by the higher number of aortic valve replacements performed within 3 months (59% versus 51%, P=0.002) and a significant decrease in the time to intervention (36±38 versus 30±33 days, P=0.002). Conclusions A simple, low-cost, facilitated data relay improves timeliness of treatment for patients diagnosed with severe aortic stenosis, resulting in a shorter time to transcatheter aortic valve replacement. This effect was mainly driven by a significant improvement in timeliness of intervention in transcatheter aortic valve replacement but not surgical aortic valve replacement. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02241447.
- MeSH
- aortální stenóza diagnostické zobrazování ošetřování terapie MeSH
- balónková valvuloplastika * škodlivé účinky MeSH
- čas zasáhnout při rozvinutí nemoci * MeSH
- časové faktory MeSH
- chirurgická náhrada chlopně * škodlivé účinky MeSH
- echokardiografie MeSH
- klinické rozhodování MeSH
- konziliární vyšetření a konzultace * MeSH
- lidé MeSH
- pozorné vyčkávání * MeSH
- prospektivní studie MeSH
- průřezové studie MeSH
- registrace MeSH
- role ošetřovatelky * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- transkatetrální implantace aortální chlopně * škodlivé účinky MeSH
- určení vhodnosti pacienta MeSH
- výběr pacientů MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
OBJECTIVES: The authors sought to evaluate the accuracy of instantaneous wave-Free Ratio (iFR) pullback measurements to predict post-percutaneous coronary intervention (PCI) physiological outcomes, and to quantify how often iFR pullback alters PCI strategy in real-world clinical settings. BACKGROUND: In tandem and diffuse disease, offline analysis of continuous iFR pullback measurement has previously been demonstrated to accurately predict the physiological outcome of revascularization. However, the accuracy of the online analysis approach (iFR pullback) remains untested. METHODS: Angiographically intermediate tandem and/or diffuse lesions were entered into the international, multicenter iFR GRADIENT (Single instantaneous wave-Free Ratio Pullback Pre-Angioplasty Predicts Hemodynamic Outcome Without Wedge Pressure in Human Coronary Artery Disease) registry. Operators were asked to submit their procedural strategy after angiography alone and then after iFR-pullback measurement incorporating virtual PCI and post-PCI iFR prediction. PCI was performed according to standard clinical practice. Following PCI, repeat iFR assessment was performed and the actual versus predicted post-PCI iFR values compared. RESULTS: Mean age was 67 ± 12 years (81% male). Paired pre- and post-PCI iFR were measured in 128 patients (134 vessels). The predicted post-PCI iFR calculated online was 0.93 ± 0.05; observed actual iFR was 0.92 ± 0.06. iFR pullback predicted the post-PCI iFR outcome with 1.4 ± 0.5% error. In comparison to angiography-based decision making, after iFR pullback, decision making was changed in 52 (31%) of vessels; with a reduction in lesion number (-0.18 ± 0.05 lesion/vessel; p = 0.0001) and length (-4.4 ± 1.0 mm/vessel; p < 0.0001). CONCLUSIONS: In tandem and diffuse coronary disease, iFR pullback predicted the physiological outcome of PCI with a high degree of accuracy. Compared with angiography alone, availability of iFR pullback altered revascularization procedural planning in nearly one-third of patients.
- MeSH
- hemodynamika * MeSH
- hyperemie patofyziologie MeSH
- klinické rozhodování MeSH
- koronární angiografie MeSH
- koronární angioplastika MeSH
- koronární cévy diagnostické zobrazování patofyziologie MeSH
- koronární cirkulace * MeSH
- lidé středního věku MeSH
- lidé MeSH
- nemoci koronárních tepen diagnóza diagnostické zobrazování patofyziologie terapie MeSH
- prediktivní hodnota testů MeSH
- prospektivní studie MeSH
- registrace MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srdeční katetrizace metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
OBJECTIVES: To evaluate the first experience of real-time instantaneous wave-free ratio (iFR) measurement by clinicians. BACKGROUND: The iFR is a new vasodilator-free index of coronary stenosis severity, calculated as a trans-lesion pressure ratio during a specific period of baseline diastole, when distal resistance is lowest and stable. Because all previous studies have calculated iFR offline, the feasibility of real-time iFR measurement has never been assessed. METHODS: Three hundred ninety-two stenoses with angiographically intermediate stenoses were included in this multicenter international analysis. Instantaneous wave-free ratio and fractional flow reserve (FFR) were performed in real time on commercially available consoles. The classification agreement of coronary stenoses between iFR and FFR was calculated. RESULTS: Instantaneous wave-free ratio and FFR maintain a close level of diagnostic agreement when both are measured by clinicians in real time (for a clinical 0.80 FFR cutoff: area under the receiver operating characteristic curve [ROC(AUC)] 0.87, classification match 80%, and optimal iFR cutoff 0.90; for a ischemic 0.75 FFR cutoff: iFR ROC(AUC) 0.90, classification match 88%, and optimal iFR cutoff 0.85; if the FFR 0.75-0.80 gray zone is accounted for: ROC(AUC) 0.93, classification match 92%). When iFR and FFR are evaluated together in a hybrid decision-making strategy, 61% of the population is spared from vasodilator while maintaining a 94% overall agreement with FFR lesion classification. CONCLUSION: When measured in real time, iFR maintains the close relationship to FFR reported in offline studies. These findings confirm the feasibility and reliability of real-time iFR calculation by clinicians.
- MeSH
- frakční průtoková rezerva myokardu MeSH
- koronární angiografie metody MeSH
- koronární cirkulace * MeSH
- koronární stenóza diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- plocha pod křivkou MeSH
- ROC křivka MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- srdeční katetrizace metody MeSH
- studie případů a kontrol MeSH
- stupeň závažnosti nemoci MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- MeSH
- balónková koronární angioplastika metody využití MeSH
- finanční podpora výzkumu jako téma MeSH
- koronární angiografie využití MeSH
- koronární restenóza prevence a kontrola MeSH
- lidé MeSH
- revaskularizace myokardu metody využití MeSH
- sirolimus aplikace a dávkování terapeutické užití MeSH
- stenty využití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- multicentrická studie MeSH