BACKGROUND: Strokes after left atrial appendage closure (LAAC) prophylaxis are generally less severe than those after warfarin prophylaxis-thought to be secondary to more hemorrhagic strokes with warfarin. Hemorrhagic strokes are similarly infrequent with direct oral anticoagulant (DOAC) prophylaxis, so the primary subtype after either LAAC or DOAC prophylaxis is ischemic stroke (IS). OBJECTIVES: The purpose of this study was to compare the severity of IS using the modified Rankin Scale in atrial fibrillation patients receiving prophylaxis with DOACs vs LAAC. METHODS: A retrospective analysis was performed of consecutive patients undergoing LAAC at 8 centers who developed an IS (ISLAAC) compared with contemporaneous consecutive patients who developed IS during treatment with DOACs (ISDOAC). The primary outcome was disabling/fatal stroke (modified Rankin Scale 3-5) at discharge and 3 months later. RESULTS: Compared with ISDOAC patients (n = 322), ISLAAC patients (n = 125) were older (age 77.2 ± 13.4 years vs 73.1 ± 11.9 years; P = 0.002), with higher HAS-BLED scores (3.0 vs 2.0; P = 0.004) and more frequent prior bleeding events (54.4% vs 23.6%; P < 0.001), but similar CHA2DS2-VASc scores (5.0 vs 5.0; P = 0.28). Strokes were less frequently disabling/fatal with ISLAAC than ISDOAC at both hospital discharge (38.3% vs 70.3%; P < 0.001) and 3 months later (33.3% vs 56.2%; P < 0.001). Differences in stroke severity persisted after propensity score matching. By multivariate regression analysis, ISLAAC was independently associated with fewer disabling/fatal strokes at discharge (OR: 0.22; 95% CI: 0.13-0.39; P < 0.001) and 3 months (OR: 0.25; 95% CI: 0.12-0.50; P < 0.001), and fewer deaths at 3 months (OR: 0.28; 95% CI: 0.12-0.64; P < 0.001). CONCLUSIONS: Ischemic strokes in patients with atrial fibrillation are less often disabling or fatal with LAAC than DOAC prophylaxis.
- MeSH
- antikoagulancia škodlivé účinky MeSH
- cévní mozková příhoda * epidemiologie etiologie prevence a kontrola MeSH
- fibrilace síní * komplikace farmakoterapie chirurgie MeSH
- hemoragická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- ischemická cévní mozková příhoda * chemicky indukované komplikace farmakoterapie MeSH
- krvácení chemicky indukované MeSH
- lidé středního věku MeSH
- lidé MeSH
- retrospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- uzávěr ouška levé síně MeSH
- výsledek terapie MeSH
- warfarin škodlivé účinky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .
- MeSH
- fibrilace síní * chirurgie terapie MeSH
- jednoduchá slepá metoda MeSH
- katetrizační ablace * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrofyziologické techniky kardiologické MeSH
- fibrilace síní * chirurgie patofyziologie diagnóza MeSH
- katetrizační ablace * metody přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva * MeSH
- senioři MeSH
- srdeční frekvence MeSH
- srdeční katétry * MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Because of its safety, "single-shot" pulsed field ablation (PFA) catheters have been developed for pulmonary vein isolation (PVI). However, most atrial fibrillation (AF) ablation procedures are performed with focal catheters to permit flexibility of lesion sets beyond PVI. OBJECTIVES: This study sought to determine the safety and efficacy of a focal ablation catheter able to toggle between radiofrequency ablation (RFA) or PFA to treat paroxysmal or persistent AF. METHODS: In a first-in-human study, a focal 9-mm lattice tip catheter was used for PFA posteriorly and either irrigated RFA (RF/PF) or PFA (PF/PF) anteriorly. Protocol-driven remapping was at ∼3 months postablation. The remapping data prompted PFA waveform evolution: PULSE1 (n = 76), PULSE2 (n = 47), and the optimized PULSE3 (n = 55). RESULTS: The study included 178 patients (paroxysmal/persistent AF = 70/108). Linear lesions, either PFA or RFA, included 78 mitral, 121 cavotricuspid isthmus, and 130 left atrial roof lines. All lesion sets (100%) were acutely successful. Invasive remapping of 122 patients revealed improvement of PVI durability with waveform evolution: PULSE1: 51%; PULSE2: 87%; and PULSE3: 97%. After 348 ± 652 days of follow-up, the 1-year Kaplan-Meier estimates for freedom from atrial arrhythmias were 78.3% ± 5.0% and 77.9% ± 4.1% for paroxysmal and persistent AF, respectively, and 84.8% ± 4.9% for the subset of persistent AF patients receiving the PULSE3 waveform. There was 1 primary adverse event-inflammatory pericardial effusion not requiring intervention. CONCLUSIONS: AF ablation with a focal RF/PF catheter allows efficient procedures, chronic lesion durability, and good freedom from atrial arrhythmias-for both paroxysmal and persistent AF. (Safety and Performance Assessment of the Sphere-9 Catheter and the Affera Mapping and RF/PF Ablation System to Treat Atrial Fibrillation; NCT04141007 and NCT04194307).
- MeSH
- ablace * MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- katétry MeSH
- lidé MeSH
- venae pulmonales * chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Background: A novel QDOT MICRO (Biosense Webster, Inc., Irvine, CA) catheter with optimized temperature control and microelectrodes was designed to incorporate real-time temperature sensing with contact force detection and microelectrodes to streamline ablation workflow. The QDOT-MICRO feasibility study evaluated the workflow, performance, and safety of temperature-controlled catheter ablation in patients with symptomatic paroxysmal atrial fibrillation with conventional ablation setting. Methods: This was a non-randomized, single-arm, first-in-human study. The primary outcome was pulmonary vein isolation (PVI), confirmed by entrance block after adenosine and/or isoproterenol challenge. Safety outcomes included incidences of early-onset primary adverse events (AEs) and serious adverse device effects (SADEs). Device performance was evaluated via physician survey. Results: All evaluated patients (n = 42) displayed 100% PVI. Two primary AEs (4.8%) were reported: 1 pericarditis and 1 vascular pseudoaneurysm. An additional SADE of localized infection was reported in 1 patient. No stroke, patient deaths, or other unanticipated AEs were reported. Average power delivered was 32.1±4.1 W, with a mean temperature of 40.8°C±1.6°C. Mean procedure (including 20-minute wait), fluoroscopy, and radiofrequency application times were 129.8, 6.7, and 34.0 minutes, respectively. On device performance, physicians reported overall satisfactory performance with the new catheter, with highest scores for satisfaction and usefulness of the temperature indicator. Conclusions: Initial clinical experience with the novel catheter showed 100% acute PVI success and acceptable safety and device performance in temperature-controlled ablation mode. There were no deaths, stroke, or unanticipated AEs. Fluoroscopy and procedural times were short and similar or better than reported for prior generation catheters.
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: DIAMOND-AF (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation) was a prospective, multicenter, noninferiority, randomized trial that compared the safety and effectiveness of the DTA system versus those of a force-sensing RF ablation system (control) for the treatment of patients with drug-refractory, recurrent, symptomatic paroxysmal atrial fibrillation (AF). BACKGROUND: Irrigated radiofrequency (RF) ablation catheters lose tissue temperature acuity, which is vital in assessing lesion formation. DiamondTemp Ablation (DTA) was designed to re-establish accurate tissue temperature measurements during ablation. METHODS: A total of 482 patients with paroxysmal AF were randomized (239 DTA, 243 control) to undergo pulmonary vein isolation and were followed up at 23 sites. Patients were screened for disease progression, cardiac characteristics, and prior interventions. Primary endpoints were effectiveness (freedom from atrial arrhythmia recurrence) and safety (composite of procedure- and device-related serious adverse events). RESULTS: The primary safety event rate was 3.3% in the DTA group versus 6.6% in the control group (p < 0.001 vs. 6.5% noninferiority margin). Primary effectiveness was met in 79.1% of DTA subjects and 75.7% of control subjects (p < 0.001 vs. -12.5% noninferiority margin). Secondary endpoint analysis found that off-drug effectiveness favored DTA compared with the control (142 [59.4%] vs. 120 [49.4%], respectively; p = 0.03). Total RF time and individual RF ablation duration were significantly shorter with less saline infused through the DTA catheter (p < 0.001). Both arms saw clinically meaningful improvements in quality of life at 12 months. CONCLUSIONS: Safety and efficacy of the DTA system proved noninferior to force-sensing RF ablation in a paroxysmal AF population. Efficiencies were observed using DTA with shorter total RF times, individual RF ablation durations, and less saline infusion. (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation; NCT03334630).
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * škodlivé účinky MeSH
- katétry MeSH
- kvalita života MeSH
- lidé MeSH
- prospektivní studie MeSH
- teplota MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: The tissue selectivity of pulsed field ablation (PFA) provides safety advantages over radiofrequency ablation in treating atrial fibrillation. One-shot PFA catheters have been shown capable of performing pulmonary vein isolation, but not flexible lesion sets such as linear lesions. A novel lattice-tip ablation catheter with a compressible 9-mm nitinol tip is able to deliver either focal radiofrequency ablation or PFA lesions, each in 2 to 5 s. METHODS: In a 3-center, single-arm, first-in-human trial, the 7.5F lattice catheter was used with a custom mapping system to treat paroxysmal or persistent atrial fibrillation. Toggling between energy sources, point-by-point pulmonary vein encirclement was performed using biphasic PFA posteriorly and either temperature-controlled irrigated radiofrequency ablation or PFA anteriorly (RF/PF or PF/PF, respectively). Linear lesions were created using either PFA or radiofrequency ablation. RESULTS: The 76-patient cohort included 55 paroxysmal and 21 persistent atrial fibrillation patients undergoing either RF/PF (40 patients) or PF/PF (36 patients) ablation. The pulmonary vein isolation therapy duration time (transpiring from first to last lesion) was 22.6±8.3 min/patient, with a mean of 50.1 RF/PF lesions/patient. Linear lesions included 14 mitral (4 RF/2 RF+PF/8 PF), 34 left atrium roof (12 RF/22 PF), and 44 cavotricuspid isthmus (36 RF/8 PF) lines, with therapy duration times of 5.1±3.5, 1.8±2.3, and 2.4±2.1 min/patient, respectively. All lesion sets were acutely successful, using 4.7±3.5 minutes of fluoroscopy. There were no device-related complications, including no strokes. Postprocedure esophagogastroduodenoscopy revealed minor mucosal thermal injury in 2 of 36 RF/PF and 0 of 24 PF/PF patients. Postprocedure brain magnetic resonance imaging revealed diffusion-weighted imaging+/fluid-attenuated inversion recovery- and diffusion-weighted imaging+/fluid-attenuated inversion recovery+ asymptomatic lesions in 5 and 3 of 51 patients, respectively. CONCLUSIONS: A novel lattice-tip catheter could safely and rapidly ablate atrial fibrillation using either a combined RF/PF approach (capitalizing on the safety of PFA and the years of experience with radiofrequency energy) or an entirely PF approach. Registration: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT04141007 and NCT04194307.
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrofyziologické techniky kardiologické MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace škodlivé účinky přístrojové vybavení MeSH
- léčebná irigace škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři MeSH
- srdeční frekvence MeSH
- srdeční katetrizace škodlivé účinky přístrojové vybavení MeSH
- srdeční katétry * MeSH
- venae pulmonales patofyziologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- audiovizuální média MeSH
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
- Litva MeSH
BACKGROUND: The RADIANCE first-in-man study evaluated acute (3-month) safety and design concept in terms of utility of a new multi-electrode radiofrequency (RF) balloon catheter (HELIOSTAR, Biosense Webster) to achieve pulmonary vein isolation (PVI). After study conclusion, a subset of patients was followed up to 12 months. METHODS: Patients with drug refractory paroxysmal atrial fibrillation were enrolled. Neurological assessment, cardiac and cerebral magnetic resonance imagings were performed pre and post procedure. Ablation was delivered at 15 Watts to each PV for 60 seconds (electrodes adjacent to the posterior wall limited to 20 seconds). Adenosine or isoproterenol was administered to confirm PVI. Esophageal endoscopy was performed 48 hours post procedure. Patients were clinically followed up for 12 months. RESULTS: Thirty-nine patients underwent catheter ablation from four centers. Mean age was 60.7 ± 10.0 years with 23 (57.5%) being male. Confirmation of PVI was performed in all PVs treated (152/152). Confirmation of isolation after one delivery was performed solely on 137 of 152 PVs of which 79.6% (109/137) achieved isolation with a single delivery of RF energy. Acute PV reconnection was seen in 4.6% (7/150) of PVs. Freedom from documented atrial arrhythmia at 12 months in those followed up was 86.4% (32/37). A total of 75.7% (28/37) of patients were free from atrial arrhythmia and off antiarrhythmic medications. CONCLUSION: The HELIOSTAR RF balloon catheter allows for rapid and safe PVI with majority of PVs only requiring one application.
- MeSH
- akční potenciály MeSH
- antiarytmika terapeutické užití MeSH
- časové faktory MeSH
- elektrody * MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- přežití bez známek nemoci MeSH
- prospektivní studie MeSH
- recidiva MeSH
- registrace MeSH
- senioři MeSH
- srdeční frekvence MeSH
- srdeční katétry * MeSH
- venae pulmonales patofyziologie chirurgie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
OBJECTIVES: This study sought to evaluate the safety and acute performance of the lattice tip for the treatment of atrial flutter and fibrillation (AF). BACKGROUND: A novel catheter using an expandable lattice structure with a wide thermal footprint incorporating multiple surface thermocouples/mini-electrodes has been designed for high-resolution mapping and high-current, temperature-controlled radiofrequency ablation (RFA). METHODS: Patients with typical right atrial flutter or AF were prospectively enrolled in a single-arm study at 3 centers. Patients with atrial flutter underwent cavotricuspid isthmus (CTI) ablation. Patients with paroxysmal AF underwent pulmonary vein isolation (PVI) and CTI if desired, and for patients with persistent AF, mitral isthmus and left atrial roof lines were also permitted. Mapping was performed with the lattice (Sphere-9) catheter and a novel compatible electroanatomic mapping system (Prism-1). RFA was performed in a point-by-point fashion (Tmax, 73°C to 80°C; range 2 to 7 s). Patients were followed for 3 months. RESULTS: A total of 71 patients underwent ablation: 65 PVI (38% with persistent AF) and 22 mitral isthmus, 24 roof, and 48 CTI lines. PVI was achieved in 64 of 65 (98.5%) by using the lattice alone and required a mean of 2.7 ± 0.70 RFA min. Mitral block was achieved in 100% by using 11.5 ± 10.7 applications and 1.0 ± 0.92 RFA min; only 1 patient required adjunctive epicardial coronary sinus ablation. Roof line and CTI block were achieved in 95.8% and 100% of patients, using 4.9 ± 1.9 and 5.9 ± 3.1 applications for 0.4 ± 0.16 and 0.5 ± 0.24 RFA min, respectively. At 3 months, there were no deaths, strokes, tamponade, or atrioesophageal fistula. CONCLUSIONS: This first-in-human study demonstrated clinical feasibility and safety for rapid high-current, temperature-controlled point-by-point PVI and linear ablation.
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * MeSH
- katétry MeSH
- lidé MeSH
- teplota MeSH
- venae pulmonales * chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVES: This study was designed to evaluate lesion durability on invasive electrophysiologic remapping. BACKGROUND: The lattice-tip catheter generates a large thermal footprint during temperature-controlled irrigated radiofrequency ablation. In a first-in-human study, this catheter performed rapid point-by-point pulmonary vein isolation (PVI) and other linear atrial ablations. METHODS: In a prospective 3-center single-arm study, paroxysmal or persistent atrial fibrillation patients underwent PVI and, as needed, linear ablation at the cavotricuspid isthmus (CTI), mitral isthmus (MI), and/or left atrial roof; no other atrial substrate was ablated. Using the lattice catheter and a custom electroanatomic mapping system, temperature-controlled (Tmax 73° to 80°C; 2 to 7 s) point-by-point ablation was performed. Patients were followed for 12 months. RESULTS: A total of 65 patients (61.5% paroxysmal/38.5% persistent) underwent ablation: PVI in 65, MI in 22, left atrial roof in 24, and CTI in 48 patients. At a median of 108 days after the index procedure, protocol-mandated remapping was performed in 27 patients. The pulmonary veins (PVs) remained durably isolated in all but 1 reconnected PV-translating to durable isolation in 99.1% of PVs, or 96.3% of patients with all PVs isolated. Of 47 linear atrial lesions initially placed during the index procedure, durability was observed in 10 of 11 (90.9%) MI lines, all 11 (100%) roof lines, and all 25 (100%) CTI lines. After a median follow-up of 270 days, the 12-month Kaplan-Meier estimate for freedom from atrial arrhythmias was 94.4 ± 3.2%. CONCLUSIONS: Temperature-controlled lattice-tip point-by-point ablation showed not only highly durable PVI lesion sets, but also durable contiguity of linear atrial lesions.
- MeSH
- katetrizační ablace * MeSH
- katétry MeSH
- lidé MeSH
- prospektivní studie MeSH
- teplota MeSH
- venae pulmonales * chirurgie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH