The extraction efficiencies of thirty types of fibers produced by meltblown, alternating current electrospinning, and meltblown-co-electrospinning technologies were tested as advanced sorbents for on-line solid-phase extraction in a high-performance liquid chromatography system have been tested and compared with a commercial C18 sorbent. The properties of each fiber, which were often depended on the production process, and their applicability were demonstrated with the extraction of the model analytes nitrophenols and chlorophenols from various matrices including river water and to purify complex matrix human serum and bovine serum albumin from macromolecular ballast. Polycaprolactone fibers outperformed other polymers and were selected for subsequent modifications including (i) incorporation of hybrid carbon nanoparticles, i.e., graphene, activated carbon, and carbon black into the polymer prior to fiber fabrication, and (ii) surface modification by dip coating with polyhydroxy modifiers including graphene oxide, tannin, dopamine, hesperidin, and heparin. These novel fibrous sorbents were comparable to commercial C18 sorbent and provided excellent analyte recoveries of 70-112% even from the protein-containing matrices.
- MeSH
- extrakce na pevné fázi metody MeSH
- látky znečišťující životní prostředí * MeSH
- lidé MeSH
- nanovlákna * chemie MeSH
- polymery chemie MeSH
- řeky chemie MeSH
- sladká voda MeSH
- voda MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Advanced solid phase extraction (SPE) fibrous sorbents including polyethylene, polypropylene poly (hydroxybutyrate), and polyamide 6 nanofibers, polycaprolactone microfibers/nanofibers, polycaprolactone microfibers/polyvinylidene difluoride nanofibers, and poly (hydroxybutyrate) microfibers/polypropylene microfibers composites, as well as commercial molecularly imprinted polymers and restricted access media sorbent were compared in terms of bisphenols extraction from milk and their clean-up efficiency. Three on-line SPE-HPLC methods were completely validated for the extraction and detection of bisphenols A, AF, C, A diglycidyl ether, and F diglycidyl ether in bovine milk. Polycaprolactone composite nanofibers compared favorably to restricted access media, enabled excellent clean-up of bisphenols from the proteinaceous matrix, and yielded recoveries 98.0-124.5% and 93.0-115.0%, respectively, with RSD less than 10%. Total analysis time including on-line SPE step lasted only 12 min, which represents a significant reduction in time compared with previously reported as well as official European Union and AOAC methods defined for the determination of bisphenols in various matrices.
- MeSH
- adsorpce MeSH
- ethery MeSH
- extrakce na pevné fázi metody MeSH
- hydroxybutyráty MeSH
- mléko MeSH
- molekulárně imprintované polymery MeSH
- molekulový imprinting * metody MeSH
- nanovlákna * chemie MeSH
- polypropyleny MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions. The extract is then separated and diluted in-syringe before being submitted to online coupled UHPLC-MS/MS. A 1 mL glass syringe containing a small stir bar for solution mixing at up to 3000 rpm, was used to deal with sample volumes as small as 100 μL. A sample throughput of 7 h-1 was achieved by performing the chromatographic run and sample preparation procedure in parallel. Linear working ranges were obtained for all analytes between 5 and 100 ng mL-1, with LOD values ranging from 0.4 to 1.5 ng mL-1. Accuracy values in the range of 88.2-106% and high precision of <11% RSD suggest applicability for routine analysis that can be further improved using deuterated standards.
Para Red (PR) and Sudan dyes have been illegally used as colorants to adulterate certain foods by enhancing their red/orange colour. In addition, they are toxic and carcinogenic. This work presents the development of a simple flow injection chromatographic method combined with chemometric tools to perform the determination of PR, Sudan I (SI) and Sudan II (SII) in food samples. The flow chromatographic system consisted of a low-pressure manifold coupled to a reverse phase monolithic column. A Partial Least Square (PLS) model was applied to resolve overlapped absorption spectra registered for each dye at the corresponding retention time. The relative errors of calibration (RMSECV, %) were 0.49, 0.85 and 0.23, and the relative errors of prediction (RMSEP, %) were 1.12, 0.75 and 0.33 for PR, SI and SII, respectively. The residual predictive deviation (RPD) values obtained were higher than 3.00 for all analytes. The method was successfully applied to quantify the dyes in six different commercial spices samples. The results were compared with the HPLC reference method concluding that there were no significant differences at the studied confidence level (α = 0.05). The proposed method can be used to rapidly determine the analytes in a simple, reliable, low-cost and environmentally-friendly manner.Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-021-05299-8.
- Publikační typ
- časopisecké články MeSH
A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations. The steady-state flux values for the tested formulations were 52 µg cm-2 h-1 for Canesten, 35 µg cm-2 h-1 for Clotrimazol AL, and 7.2 µg cm-2 h-1 for Delcore measured in 4 min sampling intervals. A simplified approach for the evaluation of the initial rate based on the gradient between the second and third sampling points was used for the first time and was found to correspond well with the results of the conventional methods. A comparison based on the ratio of the steady-state flux and the initial rate values for Canesten and Clotrimazol AL proved the similarity of the obtained results. The proposed alternative was successfully implemented for the comparison of short-term kinetic profiles. Consequently, a faster and simpler approach for dissolution/liberation testing can be used.