The aim of this study was to investigate the absorbed dose and the linear energy transfer (LET) of a scanning proton pencil beam at the Proton Therapy Center Czech, applied to phantoms containing metal implants. We investigated two different phantoms composed of commonly used metals with a known chemical composition. Two rectangular phantoms consisted of water-equivalent environment material with a 65 mm thickness surrounding the 2, 5, 10 and 15 mm inserts of grade-2 and grade-5 Titanium. Track-etched detectors (TEDs) were placed behind the phantoms to gather the data. The measured LET spectra behind the implants were compared with Monte Carlo simulations using the Geant4 toolkit, version 10.03.p01. The simulations were used to provide additional information regarding the contribution of each type of particles to the LET spectra (protons, alpha particles, deuteron, neutrons, photons, and electrons) and to estimate the LET spectra above the TED's detection threshold. We used two different beam energies to study the most pertinent irradiation scenarios, one in the Bragg curve plateau and one at the maximum. The measurement of the LET spectra behind phantoms irradiated with a proton beam in the plateau region of the Bragg curve led to the detection of numerous particles with a very high LET. Lateral dose enhancement at the border between implants and the plastic material was detected when the phantoms were exposed to a proton beam and the data were recorded in the Bragg peak maximum. In this area, the dose increased 13 times for grade-2 Ti and 12 times for grade-5 Ti. The performed experimental study highlights the effect of dental implants on the LET spectra and absorbed dose when a proton pencil beam is crossing high-density titanium.
Measurements described in this article were carried out with the aim of evaluating risks of the patient exposure to secondary neutrons during treatment at the Proton Therapy Centre Prague. The neutron spectral fluence was measured by means of the extended Bonner sphere spectrometer (EBS). The article presents secondary neutron spectral fluences obtained by the EBS with passive thermoluminescent detectors, i.e. pairs of (6)LiF and (7)LiF chips. Measurements were performed in two positions: the first one behind the Nylon 6 phantom, and the second one close to the range shifter to evaluate their contribution to the generation of neutrons. Both the Nylon 6 phantom and the range shifter were irradiated with a pencil beam of protons 4 mm in diameter and the energy of 200 MeV. The results are supplemented with the values of effective dose derived from neutron spectral fluences.
Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth-dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u(-1) in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8-10 keV µm(-1), while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams.
- MeSH
- částice - urychlovače přístrojové vybavení MeSH
- dávka záření MeSH
- design vybavení MeSH
- elektrony MeSH
- kalibrace MeSH
- lineární přenos energie účinky záření MeSH
- mikrotechnologie metody MeSH
- počítačová simulace MeSH
- polymethylmethakrylát chemie MeSH
- radiometrie přístrojové vybavení MeSH
- těžké ionty * MeSH
- uhlík * MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Předmět sdělení: Kouření je nejvýznamnější jednotlivý preventabilní rizikový faktor mnoha nemocí, včetně zhoršeného orálního zdraví. Řada studií opakovaně dokumentovala vyšší prevalenci zubního kazu, nemocí parodontu, ztrát zubů a rakoviny hlavy a krku u kuřáků. Kouření může přispívat k iniciaci a progresi nemocí v dutině ústní jak nepřímo (horší výživou kuřáků i horší péčí o hygienu v dutině ústní), tak přímo. Škodlivé účinky kouření v dutině ústní jsou následkem akumulace zubních povlaků a zvýšené resorpce alveolární kosti. Jako hlavní kauzální mechanismy se uplatňují hypoxie, zánět, narušená imunita, minerální a bakteriální disbalance. Cytotoxický účinek tabákového kouře na lidské gingivální fibroblasty snižuje jejich adhezivní a proliferační kapacitu. Ve srovnání s nekuřáky je u kuřáků obvykle méně úspěšná léčba pomocí implantátů, vyskytuje se u ní řada komplikací a zhoršené hojení. Závěr: V mnoha rozvinutých zemích zubní lékaři aktivně podporují nekuřácké chování a motivují své kouřící pacienty k zanechání kouření. Tento přístup by mohl být výzvou i pro zubní lékaře v České republice. Klíčová slova: kouření – orální zdraví – ztráta zubů - mechanismy
Background: Smoking is the most important single preventable risk factor for many diseases, including impaired oral health. Many studies have repeatedly documented the higher prevalence of caries, periodontitis, tooth loss and head-neck cancer among smokers. Smoking can contribute to the initiation and progression of diseases in oral cavity both indirectly (by smokers´ bad nutrition and oral hygiene) and directly. The deleterious effect of smoking in the oral cavity is due to plaque accumulation and increased alveolar bone resorption. Main causal pathways are hypoxemia, inflammation, impaired immunity, mineral and bacterial imbalance. Cytotoxic effect of tobacco smoke on human gingival fibroblasts decreases their capacity for adhesion and proliferation. Compared to no-smokers, the outcome of implant treatment is among smokers usually less successful, as it is associated with many complications and poor healing. Conclusion: In many developed countries, dentists are active in the support of no-smoking behaviour and in motivation their smoking patients to smoking cessation. Such approach may be the challenge also for dentists in the Czech Republic. Keywords: smoking – oral health – teeth loss - pathways
- MeSH
- hojení ran MeSH
- kouření * škodlivé účinky MeSH
- lidé MeSH
- nemoci parodontu komplikace MeSH
- orální hygiena MeSH
- pooperační komplikace MeSH
- ztráta zubů * etiologie MeSH
- zubní implantáty MeSH
- zuby-sanace - selhání * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
Dose delivered outside the proton field during radiotherapy can potentially lead to secondary cancer development. Measurements with a 170-MeV proton beam were performed with passive detectors (track etched detectors and thermoluminescence dosemeters) in three different depths along the Bragg curve. The measurement showed an uneven decrease of the dose outside of the beam field with local enhancements. The major contribution to the delivered dose is due to high-energy protons with linear energy transfer (LET) up to 10 keV µm(-1). However, both measurement and preliminary Monte Carlo calculation also confirmed the presence of particles with higher LET.
- MeSH
- celková dávka radioterapie * MeSH
- design vybavení MeSH
- fantomy radiodiagnostické MeSH
- lidé MeSH
- lineární přenos energie MeSH
- metoda Monte Carlo MeSH
- neutrony MeSH
- plánování radioterapie pomocí počítače MeSH
- polymethylmethakrylát chemie MeSH
- protonová terapie škodlivé účinky MeSH
- protony * MeSH
- radiometrie přístrojové vybavení metody MeSH
- radioterapie škodlivé účinky MeSH
- reprodukovatelnost výsledků MeSH
- termoluminiscenční dozimetrie přístrojové vybavení metody MeSH
- vysokoenergetická radioterapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Rusko MeSH
PURPOSE: The aim of this work was to prospectively analyze the outcome of combined hormonal treatment and radical radiotherapy in high risk non metastatic prostate cancer patients (T1=4, N0-1, M0). METHODS: Between April 2003 and December 2007 196 patients with high risk prostate cancer were treated with curative intent. The treatment consisted of 2-month neoadjuvant hormonal treatment (LHRH analog), radical radiotherapy (68-78 Gy, conformal technique) and an optional 2-year adjuvant hormonal treatment. RESULTS: The median follow up time was 59 months. Fiveyear overall survival was 86% and 5-year biochemical disease free survival (DFS) 70%. Factors found to be statistically significant relative to outcomes were Gleason score (p=0.017), initial PSA value (p=0.039) and adjuvant hormonal treatment (p=0.035). There was no significant association between radiotherapy dose or volume and biochemical DFS (bDFS). Late genitourinary and gastrointestinal toxicity was acceptable. CONCLUSION: Treatment combining hormonal therapy and radical radiotherapy can be recommended for this subgroup of prostate cancer patients. Adjuvant hormonal treatment should also be used.
- MeSH
- adenokarcinom mortalita patologie terapie MeSH
- antitumorózní látky hormonální terapeutické užití MeSH
- celková dávka radioterapie MeSH
- chemoradioterapie * MeSH
- dospělí MeSH
- konformní radioterapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- míra přežití MeSH
- nádory prostaty mortalita patologie terapie MeSH
- následné studie MeSH
- neoadjuvantní terapie MeSH
- prognóza MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- staging nádorů MeSH
- stupeň nádoru MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
Autoři popisují metodu navigované bronchoskoie s využitím systému super Dimension Bronchus. Rozšířená bronchoskopie, dosahující periferních partií plic, využívá tzv. CT mapy s vytvořeným obrazem 3D virtuální bronchoskopie, navigovanou sondu, řiditelnou v rozsahu 360°, prodloužený pracovní kanál a lokalizační elektromagnetickou desku. K tvorbě virtuálního bronchoskopického obrazu se používají data z multidetektorových CT přístrojů nebo z hybridního PET/CT přístroje. Navigovaná bronchoskopie je prováděna v analgosedaci nebo v celkové anestezii, autoři preferují druhý z uvedených způsobů. V článku popisujeme postup vyšetření, jeho indikace a perspektivy, uvádíme čtyři kazuistiky vlastních vyšetřených pacientů.
The authors describe the method of navigation bronchoscopy using the super Dimension Bronchus system. Bronchoscopy reaching the peripheral lung regions uses the so-called CT maps with produced images of 3D virtual bronchoscopy, a navigated probe controllable in the 360° range, a longer working channel and an electromagnetic location board. To obtain virtual bronchoscopy images, data from multidetector CT or hybrid PET/CT devices are used. Navigation bronchoscopy is performed under sedation analgesia or general anaesthesia; the latter is preferred by the authors. In the article, the course of examination, its indications and outlooks sire described and four case reports are presented.
- MeSH
- bronchoskopie metody využití MeSH
- chirurgie s pomocí počítače metody trendy MeSH
- lidé MeSH
- počítačová rentgenová tomografie trendy využití MeSH
- pozitronová emisní tomografie metody využití MeSH
- zobrazování trojrozměrné metody trendy využití MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- kazuistiky MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH