The extraction efficiencies of thirty types of fibers produced by meltblown, alternating current electrospinning, and meltblown-co-electrospinning technologies were tested as advanced sorbents for on-line solid-phase extraction in a high-performance liquid chromatography system have been tested and compared with a commercial C18 sorbent. The properties of each fiber, which were often depended on the production process, and their applicability were demonstrated with the extraction of the model analytes nitrophenols and chlorophenols from various matrices including river water and to purify complex matrix human serum and bovine serum albumin from macromolecular ballast. Polycaprolactone fibers outperformed other polymers and were selected for subsequent modifications including (i) incorporation of hybrid carbon nanoparticles, i.e., graphene, activated carbon, and carbon black into the polymer prior to fiber fabrication, and (ii) surface modification by dip coating with polyhydroxy modifiers including graphene oxide, tannin, dopamine, hesperidin, and heparin. These novel fibrous sorbents were comparable to commercial C18 sorbent and provided excellent analyte recoveries of 70-112% even from the protein-containing matrices.
- MeSH
- Solid Phase Extraction methods MeSH
- Environmental Pollutants * MeSH
- Humans MeSH
- Nanofibers * chemistry MeSH
- Polymers chemistry MeSH
- Rivers chemistry MeSH
- Fresh Water MeSH
- Water MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Advanced solid phase extraction (SPE) fibrous sorbents including polyethylene, polypropylene poly (hydroxybutyrate), and polyamide 6 nanofibers, polycaprolactone microfibers/nanofibers, polycaprolactone microfibers/polyvinylidene difluoride nanofibers, and poly (hydroxybutyrate) microfibers/polypropylene microfibers composites, as well as commercial molecularly imprinted polymers and restricted access media sorbent were compared in terms of bisphenols extraction from milk and their clean-up efficiency. Three on-line SPE-HPLC methods were completely validated for the extraction and detection of bisphenols A, AF, C, A diglycidyl ether, and F diglycidyl ether in bovine milk. Polycaprolactone composite nanofibers compared favorably to restricted access media, enabled excellent clean-up of bisphenols from the proteinaceous matrix, and yielded recoveries 98.0-124.5% and 93.0-115.0%, respectively, with RSD less than 10%. Total analysis time including on-line SPE step lasted only 12 min, which represents a significant reduction in time compared with previously reported as well as official European Union and AOAC methods defined for the determination of bisphenols in various matrices.
- MeSH
- Adsorption MeSH
- Ethers MeSH
- Solid Phase Extraction methods MeSH
- Hydroxybutyrates MeSH
- Milk MeSH
- Molecularly Imprinted Polymers MeSH
- Molecular Imprinting * methods MeSH
- Nanofibers * chemistry MeSH
- Polypropylenes MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques. It mainly focuses on modern techniques such as extraction across supported liquid membrane, electroextraction, single drop microextraction, head space microextraction, and microdialysis with high spatial and temporal resolution. Finally, the design of sequential electrophoretic analysers and fabrication of SPE microcartridges with monolithic and molecularly imprinted polymeric sorbents are discussed. Applications include the monitoring of metabolites, neurotransmitters, peptides and proteins in body fluids and tissues to study processes in living organisms, as well as the monitoring of nutrients, minerals and waste compounds in food, natural and wastewater.
- MeSH
- Electrophoresis, Capillary methods MeSH
- Electrophoresis, Microchip * methods MeSH
- Microdialysis MeSH
- Publication type
- Journal Article MeSH
- Review MeSH
A double-stage Lab-In-Syringe automated extraction procedure coupled online to HPLC for the determination of four sulfonamides in urine has been developed. Our method is based on homogeneous liquid-liquid extraction at pH 3 using water-miscible acetonitrile with induction of phase separation by the addition of a saturated solution of kosmotropic salts MgSO4 and NaCl. The procedure allowed extraction of the moderately polar model analytes and the use of a solvent that is compatible with the used separation technique. The automated sample preparation system based on the stirring-assisted Lab-In-Syringe approach was coupled on-line with HPLC-UV for the subsequent separation of the sulfonamide antibiotics. To improve both preconcentration factor and extract cleanup, the analytes were trapped at pH 10 in an anion-exchange resin cartridge integrated into the HPLC injection loop thus achieving a double-stage sample clean-up. Analytes were eluted using an acidic HPLC mobile phase in gradient elution mode. Running the analytes separation and the two-step preparation of the following sample in parallel reduced the total time of analysis to mere 13.5 min. Limits of detection ranged from 5.0 to 7.5 μg/L with linear working ranges of 50-5000 μg/L (r2 > 0.9997) and RSD ≤ 5% (n = 6) at a concentration level of 50 μg/L. Average recovery values were 102.7 ± 7.4% after spiking of urine with sulfonamides at concentrations of 2.5 and 5 mg/L followed by 5 times dilution. To the best of our knowledge, the use of Lab-In-Syringe for the automation of coupled homogeneous liquid-liquid extraction and SPE for preparation of the complex matrices suitable for separation techniques is here presented for the first time.
Oxandrolone, a synthetic testosterone analog, is used for the treatment of several diseases associated with weight loss. Unfortunately, oxandrolone is abused by many athletes and bodybuilders due to its strong anabolic effect. We have developed and validated a highly sensitive and rapid on-line SPE-UHPLC-MS/MS method for the determination of oxandrolone and simultaneous identification of its major metabolite 17-epi-oxandrolone in urine matrices. Enrichment of the analytes via an integrated solid-phase extraction was achieved using an Acquity UPLC BEH C18 Column. Subsequently, the chromatographic separation of the on-line preconcentrated sample fraction was achieved using an Acquity HSS T3 C18 Column. For the structural identification of these analytes, a high-resolution mass spectrometer Synapt-G2Si coupled to the Acquity M-class nano-LC system with ionKey source was used. A highly sensitive determination of oxandrolone was achieved using a tandem quadrupole mass spectrometer XEVO TQD. The method was successfully validated in the linear range of oxandrolone from 81.63 pg·mL-1 (limit of quantification, LOQ) to 5000 pg·mL-1 in the human urine matrix. It was applied to the analysis of real urine samples obtained from a healthy volunteer after the oral administration of one dose (10 mg) of oxandrolone. Concentration vs. time dependence was tested in the time interval of 4 h-12 days (after oral administration) to demonstrate the ability of the method to detect the renal elimination of oxandrolone from the human body. Favorable performance parameters along with successful application indicate the usefulness of the proposed method for its routine use in antidoping control labs.
According to the EU legislation, ochratoxin A contamination is controlled in wines. Tokaj wine is a special type of sweet wine produced from botrytized grapes infected by "noble rot" Botrytis cinerea. Although a high contamination was reported in sweet wines and noble rot grapes could be susceptible to coinfection with other fungi, including ochratoxigenic species, no screening of Tokaj wines for mycotoxin contamination has been carried out so far. Therefore, we developed an analytical method for the determination of ochratoxin A (OTA) and ochratoxin B (OTB) involving online SPE coupled to HPLC-FD using column switching to achieve the fast and sensitive control of mycotoxin contamination. The method was validated with recoveries ranging from 91.6% to 99.1% with an RSD less than 2%. The limits of quantification were 0.1 and 0.2 µg L-1 for OTA and OTB, respectively. The total analysis time of the online SPE-HPLC-FD method was a mere 6 min. This high throughput enables routine analysis. Finally, we carried out an extensive investigation of the ochratoxin contamination in 59 Slovak Tokaj wines of 1959-2017 vintage. Only a few positives were detected. The OTA content in most of the checked wines did not exceed the EU maximum tolerable limit of 2 µg L-1, indicating a good quality of winegrowing and storing.
- MeSH
- Food Analysis methods MeSH
- Chromatography, Liquid MeSH
- Solid Phase Extraction MeSH
- Food Contamination analysis MeSH
- Ochratoxins analysis MeSH
- Quality Control MeSH
- Sensitivity and Specificity MeSH
- Wine analysis MeSH
- Vitis chemistry MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
On-line SPE HPLC method using nanofibrous sorbents for the extraction and determination of resveratrol in wine was developed and validated. Different types of nanofibrous and microfibrous polymers were tested and compared with commercial monolithic C18 sorbent. Polyamide and polyacrylonitrile nanofibers and composite materials composed of respective polycaprolactone and poly(vinylidene difluoride) nanofibers at microfibrous scaffold were included among tested materials. Two different polycaprolactone-based materials were prepared and their effect on the extraction properties studied. Alternatively, dopamine-coated polycaprolactone fibers were also used. Poly(vinylidene difluoride) nanofibers/polycaprolactone microfibers composite was found as the most effective sorbent and utilized for the method validation. Resveratrol in red wine was determined using our validated on-line SPE HPLC method.
Effective process, including a cartridge packing polypropylene fiber sorbent modified by following on-line polydopamine coating, for on-line solid phase extraction in 2D UHPLC system has been developed. Hydrophobic surface of mechanically stable polypropylene fibers was hydrophilized using an automated and reproducible in situ coating process to enable good wettability and effective extraction of polar compounds. Polymerization mixture consisting dopamine and TRIS buffer was circulated through the cartridge containing polypropylene fibers using a peristaltic pump to achieve polymerization. This process was optimized in terms of dopamine amount in the polymerization mixture, its flow rate, and polymerization time. Best results were obtained with 25 mL polymerization mixture containing 20 mg dopamine circulated through the cartridge at a flow rate of 2.07 mL min-1 for 60 min. Prepared cartridges were evaluated via measurement of the recovery and reproducibility using chlorogenic acid as a model compound. Overall reproducibility of our multistep process including eight cartridges in 2D UHPLC system, each measured in triplicate, was 3.61% (n = 24).
- Publication type
- Journal Article MeSH
Polycaprolactone composite nanofibers coated with a polydopamine layer are introduced as a new type of absorption material for on-line solid phase extraction (SPE) in chromatographic system. A hybrid technology combining the electrospinning and melt blowing was used for the preparation of 3D-structured microfiber/nanofibrous polycaprolactone composite. The dopamine coating was then applied to functionalize the micro/nanofibers. Polydopamine-coated polycaprolactone fibers were tested as an extraction phase in on-line SPE prior to HPLC separation and UV detection. Four groups of biologically active substances including bisphenols (Bisphenol S, Bisphenol AF, Bisphenol A, Bisphenol C, Bisphenol AP, Bisphenol Z, Bisphenol BP, and Bisphenol M), betablockers (Timolol, Metoprolol, Labetalol, and Propranolol), nonsteroidal antiphlogistic drugs (Salicylic acid, Ketoprofen, Naproxen, Indomethacin, Diclofenac, Ibuprophen, and Meclofenamic acid), and phenolic acids (Chlorogenic acid, Caffeic acid, Sinapic acid, m-Coumaric acid, Benzoic acid, and Cinnamic acid) were used as the model analytes. Neat and coated fibers were compared and applied as sorbents for the on-line extraction set-up. Both materials produced good extraction potential for the determination of bisphenols and nonsteroidal drugs in model biological and environmental samples including river water, human urine, and blood serum. However, the polydopamine layer significantly increased the extraction efficiency of polar drugs. Typical repeatability of on-line extraction procedure on polydopamine coated fibers was in the range 0.12-4.11% for bisphenols, 0.55-1.41% for antiphlogistic drugs, 0.59-2.52% for phenolic acids, and 1.01-1.65% for betablockers. Graphical abstract Schematic representation of polycaprolactone composite nanofibers coated with a polydopamine layer as an advanced absorption material for on-line solid phase extraction in chromatography.
- MeSH
- Anti-Inflammatory Agents, Non-Steroidal analysis isolation & purification MeSH
- Adrenergic beta-Antagonists analysis isolation & purification MeSH
- Water Pollutants, Chemical analysis isolation & purification MeSH
- Cinnamates analysis isolation & purification MeSH
- Solid Phase Extraction methods MeSH
- Phenols analysis isolation & purification MeSH
- Indoles chemistry MeSH
- Nanofibers chemistry MeSH
- Polyesters chemistry MeSH
- Polymerization MeSH
- Polymers chemistry MeSH
- Rivers chemistry MeSH
- Reproducibility of Results MeSH
- Chromatography, High Pressure Liquid MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH