BACKGROUND: The acromion projects laterally in a curving orientation. When a fracture of the acromion occurs, despite being rare, matching the best-fit fixation plate is challenging due to few options and limited availability of fixation plate types. Alternative fixation methods can carry risk of nonunion complications. PURPOSE: The objective of this study was to investigate the morphological curvature pattern of the acromion to assess the level of the fixation plates fitness and provide the suitable imaging modalities for evaluating the acromion curvature. BASIC PROCEDURES: The correlation between the acromion curvature and five fixation plates were calculated and their fitness level was evaluated statistically. The curvature of acromion and the five available fixation plates were photographed and assessed digitally by software (FIJI ImageJ and Microsoft Excel). The method entails plotting seven points along the curving surface and margins of the acromion, while the Excel Solver function calculates the regression, ultimately giving curvature values. First, the acromion parameters were studied on 180 paired healthy dry scapulae. Then, the acromion curvature values were compared to the fixation plates curvatures. Likewise, the acromion curvature was assessed as applicable on 153 (100 AP- views, 50 Y- views, and 3 superior-views) retrospective plain X-rays and 40 3D-CT scapula reconstructions of healthy acromia. MAIN FINDINGS: The mean length of the acromion was 48.70 ± 5.29 mm, mean thickness was 8.51 ± 1.67 mm, and mean width was 25.97 ± 5.97 mm. The calculated values of the mean curvatures were 0.050 ± 0.015 mm-1 for the mean acromion surface, 0.042 ± 0.027 mm-1 for the internal margin, and 0.055 ± 0.010 mm-1 for the external margin. The curved geometry of the acromion was plotted on a graph giving a spectrum of curvature patterns with distribution values revealing fixation plates fitness represented by area under the curve with frequencies of 4.32 % for the acromion-specific fixation plate, 14.28 % for the large clavicle fixation plate, 0.26 % for the small clavicle fixation plate, 53.38 % for the flexible universal fixation plate, and none for the rigid universal fixation plate. PRINCIPAL CONCLUSIONS: Approximately 27.76 % of the acromion surface curvatures distribution does not overlap with any of our measured fixation plates. Evaluating the acromion surface curvature was possible on plain X-rays in the Y-view only.
- MeSH
- Acromion * diagnostic imaging injuries anatomy & histology surgery MeSH
- Fractures, Bone * surgery diagnostic imaging MeSH
- Bone Plates * MeSH
- Humans MeSH
- Scapula * diagnostic imaging anatomy & histology MeSH
- Radiography MeSH
- Fracture Fixation, Internal * methods instrumentation MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
Úvod: 3D tisk, koncept starý přes 40 let, nachází díky technologickému pokroku stále širší uplatnění v klinické praxi. Ve FN Ostrava je využíván k vytváření anatomických modelů konkrétních pacientů před chirurgickými výkony na základě dat ze zobrazovacích vyšetření. Kazuistiky: 3D tisk nachází uplatnění jako doplněk ke konvenčním zobrazovacím metodám s cílem zhotovit morfologicky přesné modely anatomických struktur konkrétních pacientů. Tyto modely slouží především pro předoperační přípravu v elektivní břišní, cévní a hrudní chirurgii. Využívají se rovněž při plánování osteosyntéz složitých zlomenin a korekčních osteotomií. Vícebarevný tisk, přestože zvyšuje časovou náročnost procesu, umožňuje lepší přehlednost a diferenciaci jednotlivých anatomických struktur v rámci jednoho modelu. Diskuze: 3D modely poskytují lepší prostorovou orientaci a rozpoznání operovaných struktur než 2D obrazy, což přispívá k lepším výsledkům zákroků. Jejich přínos je potvrzen studiemi napříč obory, od kardiochirurgie po traumatologii. Závěr: Po odstranění počátečních překážek se 3D tisk stal spolehlivou součástí arzenálu Chirurgické kliniky FN Ostrava pro elektivní chirurgii. I když 3D tisk nepředstavuje univerzální odpověď na všechny výzvy, kterým v medicíně čelíme, jeho role je v řadě indikovaných případů velmi přínosná a perspektivní.
Introduction: 3D printing, a concept over 40 years old, is finding broader application in clinical practice thanks to technological advancements. At University Hospital Ostrava, 3D printing is utilized to create anatomically accurate models of specific patients before surgical procedures based on imaging data. Case series: 3D printing is employed as a complement to conventional imaging methods to produce morphologically precise models of anatomical structures of individual patients. These models primarily serve for preoperative planning in elective abdominal, vascular, and thoracic surgery. They are also used in planning osteosynthesis of complex fractures and corrective osteotomies. Multicolor printing, although increasing the process‘s time demands, allows better clarity and differentiation of individual anatomical structures within a single model. Discussion: Compared to 2D images, 3D models provide better spatial orientation and awareness of the operated structures, contributing to improved surgical outcomes. The benefits of 3D printing in preoperative planning and patient education are confirmed by studies across the fields ranging from cardiac surgery to traumatology. Conclusion: After overcoming initial challenges, 3D printing has become a reliable component of the surgical arsenal at University Hospital Ostrava for elective surgery. While 3D printing does not represent a universal answer to all medical challenges, its role is highly beneficial and promising in many indicated cases.
... Brain Injury /129 -- B2.5.1 Diffuse Brain Injury /129 -- B2.5.2 Scalp Injury /130 -- B2.5.3 Skull Fractures ... ... /130 -- B2.5.4 Skull Base Fractures /132 -- B2.5.5 Epidural Haematoma /139 -- B2.5.6 Subdural Haematoma ... ... Bludovsky) /237 -- B7.1 Pathophysiology and Morphology /237 -- B7.1.1 Changes in the Paravertebral Muscles ... ... Injury according to Level /254 -- B8.6.1 Injuries to the Cervical Spine /254 -- B8.6.2 Thoracolumbar Fractures ... ... /256 -- B8.7 Osteoporotic Fractures /258 -- B8.8 Care for Patients with Spinal Cord Injuries in the ...
1. elektronické vydání 1 online zdroj (292 stran)
PURPOSE OF THE STUDY: To investigate the effects of anatomical variations on the mechanism of scaphoid fracture by comparing the radiologic parameters of the wrist of patients with and without scaphoid fracture after a fall on an outstretched hand. MATERIAL AND METHODS: Cross-sectional comparative retrospective analysis of radiographs of patients with (Group 1, n=169) and without scaphoid fracture (Group 2, n=188). Morphometric data were measured including radial inclination (RI), radial height (RH), ulnar variance (UV), carpal height (CH) ratio, revised carpal height (RCH) ratio and palmar tilt of the distal radius (PT). Receiver operating characteristics (ROC) curve analysis was used to assess the diagnostic performance for each variable with statistically significant difference. RESULTS: The mean RI and PT degrees and RH length were statistically significantly higher, and the mean UV was lower in Group 1 compared to Group 2. No difference was determined between the groups with respect to the CH ratio and RCH ratio. With ROC curve analysis, the cut-off value with the highest odds ratio was determined as RH (Cut-off value=10.77 mm, OR=21.886). CONCLUSIONS: Although higher RI, RH, PT values and more negative ulnar variance were observed in the scaphoid fracture group compared to the non-fracture group, ROC curve analysis showed that only increased RH can be considered as a possible risk factor for scaphoid fractures after fall on an outstretched hand. KEY WORDS: radiographs, risk factor, scaphoid fracture, wrist morphology.
- MeSH
- Scaphoid Bone * injuries diagnostic imaging MeSH
- Adult MeSH
- Fractures, Bone * diagnostic imaging etiology MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Wrist Injuries diagnostic imaging etiology MeSH
- Cross-Sectional Studies MeSH
- Radiography * methods MeSH
- Retrospective Studies MeSH
- Accidental Falls * MeSH
- Wrist Joint diagnostic imaging MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Comparative Study MeSH
Bosworth fracture (BF) is a special type of locked ankle fracture-dislocation, characterized by displacement of a fragment of the fractured fibula from the fibular notch behind the posterior surface of the distal tibia. BF is a complex injury affecting multiple structures of the ankle joint, which is still frequently misjudged even today, potentially leading to severe complications. CT examination, including 3D reconstructions, should be the diagnostic standard in BF, as it provides a complete picture of the fracture pathoanatomy, most prominently the morphology of the frequently associated posterior malleolar fracture. BF requires early reduction of the displaced fibular fragment without repeated attempts on closed reduction. Non-operative treatment of BF almost always fails. The standard treatment procedure is early open reduction internal fixation. Due to the relative severity and paucity of the injury, BF seems to be particularly prone to soft tissue complications, including compartment syndrome. The results of operative treatment are mixed. Many studies report persistent pain even after a short time interval, with limitations of the range of motion or even stiffness of the ankle joint, and development of degenerative changes. Larger studies with long-term results are still missing.
- Publication type
- Journal Article MeSH
- Review MeSH
STATEMENT OF PROBLEM: Fatigue failure of implant components is a common clinical problem. Plasma nitriding, an in situ surface-strengthening method, may improve fatigue properties of dental implants. PURPOSE: The purpose of this in vitro study was to evaluate the effect of plasma nitriding on the fatigue behavior of implant systems. MATERIAL AND METHODS: The preload and friction coefficient of plasma nitrided abutment screws, as well as settlement of the implant-abutment interface, were measured. Then, the reverse torque values and pullout force were evaluated after cyclic loading. Finally, the fatigue properties of the implant system were investigated with static fracture and dynamic fatigue life tests, and the morphology of the fracture on the surface of the implant system was observed. RESULTS: The plasma nitriding treatment reduced the friction coefficient; increased the preload, settlement value, reverse torque values, pullout force, and static fracture load; and prolonged fatigue life. Furthermore, abutment screws with plasma nitriding treatment showed a different fatigue fracture mode. CONCLUSIONS: Plasma nitriding improved mechanical performance and may be a suitable way to optimize the fatigue behavior of dental implants.
INTRODUCTION: Complex ankle fractures frequently include the posterior malleolus (PM). Despite advances in diagnostic and treatment strategies, PM fracture involvement still predisposes to worse outcomes. While not incorporated into the most common PM fracture classifications, the presence of an intercalary fragment (ICF) complicates treatment. This study aims to describe the incidence, morphology, and location of ICFs in PM fractures. MATERIALS AND METHODS: A total of 135 patients with a mean age of 54.4 (SD ± 18.9) years and PM fractures were analyzed for the presence of an ICF. Patients with an ICF were compared to those without in terms of age, gender, and treatment received. Characteristics of the ICFs in terms of location and size were assessed. Furthermore, the presence of an ICF in relation to the PM fracture classification according to Haraguchi et al., Bartoníček/Rammelt et al., and Mason et al. was investigated. RESULTS: ICFs presented in 55 (41%) of the 135 patients. Patients with an ICF were younger, and the PM was more often operatively treated when compared to patients without an ICF. A posterolateral approach was used significantly more often in patients with an ICF. Almost all ICFs were found in the posterolateral (58%) and posterocentral (35%) regions. The majority of fragments were found in Bartoníček/Rammelt type 2 fractures, the most common fracture type. Bartoníček/Rammelt type 3 fractures had the highest relative frequency of ICFs. CONCLUSION: ICFs are frequently found in PM fractures; however, they are not incorporated into any of the common classifications. They are generally found in younger patients and associated with more complex PM fractures. As they can complicate reduction of the main fragment and may require direct exposure to restore joint congruency, ICFs should be considered in PM fracture classifications. Due to their location, the majority of ICFs are able to be accessed using a posterolateral approach.
- MeSH
- Ankle Fractures * diagnostic imaging surgery MeSH
- Incidence MeSH
- Middle Aged MeSH
- Humans MeSH
- Tomography, X-Ray Computed MeSH
- Retrospective Studies MeSH
- Tibia MeSH
- Fracture Fixation, Internal MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
PURPOSE OF THE STUDY The study aimed to draw up a diagnosis and treatment guidelines for the management of the most common compression fractures of the thoracolumbar spine in children. MATERIAL AND METHODS Between 2015 and 2017, pediatric patients with a thoracolumbar injury aged 0-12 years were followed up in the University Hospital in Motol and the Thomayer University Hospital. The age and gender of the patient, injury etiology, fracture morphology, number of injured vertebrae, functional outcome (VAS and ODI modified for children), and complications were assessed. An X-ray was performed in all patients, in indicated cases also an MRI scan was done, and in more severe cases a CT scan was obtained as well. RESULTS The average vertebral body kyphosis in patients with one injured vertebra was 7.3° (range 1.1°-12.5°). The average vertebral body kyphosis in patients with two injured vertebrae was 5.5° (range 2.1°-12.2°). The average vertebral body kyphosis in patients with more than two injured vertebrae was 3.8° (range 0.2°-11.5°). All patients were treated conservatively in line with the proposed protocol. No complications were observed, no deterioration of the kyphotic shape of the vertebral body was reported, no instability occurred, and no surgical intervention had to be considered. DISCUSSION Pediatric spine injuries are in most cases treated conservatively. Surgical treatment is opted for in 7.5-18% of cases, in dependence on the evaluated group of patients, age of the patients and philosophy of the department concerned. In our group, all patients were treated conservatively. CONCLUSIONS 1. To diagnose F0 fractures, two unenhanced orthogonal view X-rays are indicated, whereas MRI examination is not routinely performed. In F1 fractures, an X-ray is indicated, and an MRI scan is considered based on the age and extent of injury. In F2 and F3 fractures, an X-ray is indicated and subsequently the diagnosis is confirmed by MRI, in F3 fractures also a CT scan is performed. 2. In young children (under 6 years of age), in whom an MRI procedure would require general anaesthesia, MRI is not routinely performed. 3. In F0 fractures, crutches or a brace are not indicated. In F1 fractures, verticalization using crutches or a brace is considered in dependence on the patient's age and extent of injury. In F2 fractures, verticalization using crutches or a brace is indicated. 4. In F3 fractures, surgical treatment is considered, followed by verticalization using crutches or a brace. In case of conservative treatment, the same procedures as in F2 fractures are applied. 5. Long-term bed rest is contraindicated. 6. Duration of spinal load reduction (restriction of sports activities, or verticalization using crutches or a brace) in F1 injuries is 3-6 weeks based on the age of the patient, it increases with the age, with the minimum being 3 weeks. 7. Duration of spinal load reduction (verticalization using crutches or a brace) in F2 and F3 injuries is 6-12 weeks based on the age of the patient, it increases with the age, with the minimum being 6 weeks. Key words: pediatric spine injury, thoracolumbar compression fractures, children trauma treatment.
- MeSH
- Lumbar Vertebrae diagnostic imaging surgery MeSH
- Child MeSH
- Spinal Fractures * diagnostic imaging etiology MeSH
- Thoracic Vertebrae diagnostic imaging surgery MeSH
- Infant MeSH
- Fractures, Compression * diagnostic imaging etiology MeSH
- Kyphosis * surgery MeSH
- Humans MeSH
- Infant, Newborn MeSH
- Child, Preschool MeSH
- Treatment Outcome MeSH
- Check Tag
- Child MeSH
- Infant MeSH
- Humans MeSH
- Infant, Newborn MeSH
- Child, Preschool MeSH
- Publication type
- English Abstract MeSH
- Journal Article MeSH
OBJECTIVES: To investigate the anatomical feasibility of the infraspinatus branch of the suprascapular nerve (IB-SSN) reconstruction by lower subscapular nerve (LSN) transfer. METHODS: The morphological study was performed on 18 adult human cadavers. The length of the distal stump of the IB-SSN, the length of the LSN available for reconstruction and diameter of both stumps were measured. The feasibility study of the LSN to IB-SSN transfer was performed. RESULTS: The mean length of the IB-SSN to the end of its first branch was 40.9 mm (±4.6). Its mean diameter was 2.3 mm (±0.3). The mean length of the LSN stump, which was mobilized from its original course and transferred to reach the distal stump of the IB-SSN was 66.5 mm (±11.8). Its mean diameter was 2.1 mm (±0.3). The mean ratio between LSN and IB-SSN diameters was 0.9 (±0.1). The nerve transfer was feasible in 17 out of 18 cases (94.4%). CONCLUSION: This study demonstrates that direct LSN to IB-SSN transfer is anatomically feasible in most cases in the adult population. It may be used in cases of complex scapular fractures resulting in severe suprascapular nerve injury.
- MeSH
- Adult MeSH
- Humans MeSH
- Nerve Transfer * methods MeSH
- Brachial Plexus * surgery MeSH
- Nerve Regeneration physiology MeSH
- Rotator Cuff MeSH
- Feasibility Studies MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Publication type
- Journal Article MeSH
This paper introduces a complex novel concept and methodology for the creation of personalized biomedical appliances 3D-printed from certified biocompatible photopolymer resin Dental LT Clear (V2). The explained workflow includes intraoral and CT scanning, patient virtualization, digital appliance design, additive manufacturing, and clinical application with evaluation of the appliance intended for patients with cranio-facial syndromes. The presented concept defines virtual 3D fusion of intraoral optical scan and segmented CT as sufficient and accurate data defining the 3D surface of the face, intraoral and airway morphology necessary for the 3D design of complex personalized intraoral and extraoral parts of the orthopedic appliance. A central aspect of the concept is a feasible utilization of composite resin for biomedical prototyping of the sequence of marginally different appliances necessary to keep the pace with the patient rapid growth. Affordability, noninvasiveness, and practicality of the appliance update process shall be highlighted. The methodology is demonstrated on a particular case of two-year-old infant with Pierre Robin sequence. Materialization by additive manufacturing of this photopolymer provides a highly durable and resistant-to-fracture two-part appliance similar to a Tübingen palatal plate, for example. The paper concludes with the viability of the described method and material upon interdisciplinary clinical evaluation of experts from departments of orthodontics and cleft anomalies, pediatric pneumology and phthisiology, and pediatric otorhinolaryngology.
- Publication type
- Journal Article MeSH