optical fiber sensor
Dotaz
Zobrazit nápovědu
Remote detection of hydrogen, without the utilization of electronic component or elevated temperature, is one of the hot topics in the hydrogen technology and safety. In this work, the design and realization of the optical fiber-based hydrogen sensor with unique characteristics are proposed. The proposed sensor is based on the gold-coated multimode fiber, providing the plasmon properties, decorated by the IRMOF-20 layer with high selectivity and affinity toward hydrogen. The IRMOF-20 layer was grown by a surface-assisted technique, and its formation and properties were studied using X-ray photoelectron spectroscopy, Raman, X-ray diffraction, and Brunauer-Emmett-Teller techniques. Simultaneous ellipsometry results indicate the apparent changes of the refractive index of the IRMOF-20 layer due to hydrogen sorption. As results, the presence of hydrogen led to the pronounced changes of plasmon band wavelength position as well as its intensity increase. The proposed hydrogen sensors were favorably distinguished by a high response/recovery rate, excellent selectivity toward the hydrogen, very low temperature dependency, functionality at room or lower temperature, insensitivity toward the humidity, and the presence of CO2, CO, or NO2. Additionally, the proposed hydrogen sensor showed good reversibility, reproducibility, and long-term stability.
In this article, we briefly describe the design, construction, and functional verification of a hybrid multichannel fiber-optic sensor system for basic vital sign monitoring. This sensor uses a novel non-invasive measurement probe based on the fiber Bragg grating (FBG). The probe is composed of two FBGs encapsulated inside a polydimethylsiloxane polymer (PDMS). The PDMS is non-reactive to human skin and resistant to electromagnetic waves, UV absorption, and radiation. We emphasize the construction of the probe to be specifically used for basic vital sign monitoring such as body temperature, respiratory rate and heart rate. The proposed sensor system can continuously process incoming signals from up to 128 individuals. We first present the overall design of this novel multichannel sensor and then elaborate on how it has the potential to simplify vital sign monitoring and consequently improve the comfort level of patients in long-term health care facilities, hospitals and clinics. The reference ECG signal was acquired with the use of standard gel electrodes fixed to the monitored person's chest using a real-time monitoring system for ECG signals with virtual instrumentation. The outcomes of these experiments have unambiguously proved the functionality of the sensor system and will be used to inform our future research in this fast developing and emerging field.
- MeSH
- dechová frekvence MeSH
- lidé MeSH
- monitorování fyziologických funkcí MeSH
- optická vlákna MeSH
- srdeční frekvence MeSH
- technologie optických vláken * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
In this work we discuss a new label-free biosensing device based on indium tin oxide (ITO) overlaid section of a multimode optical fiber fused silica core. The sensor has been used to optical measurements also simultaneously interrogated electrochemically (EC). Due to optimized thickness and optical properties of ITO film, a lossy-mode resonance (LMR) could be observed in the optical domain, where electrical properties of the film allowed for application of the sensor as a working electrode in an EC setup. It has been confirmed that the LMR response depends on optical properties of the external medium, as well as potential applied to the electrode during cyclic voltammetry. After the ITO surface functionalization with amine groups and covalently attached biotin, the device has been applied for label-free biosensing of avidin in both the domains simultaneously. On the example of biotin-avidin detection system it was demonstrated that when avidin concentration increases a decrease in current and increase in LMR wavelength shift were recorded in EC and optical domain, respectively. Both optical and EC responses follow the protein interaction process, and thus can be used as cross-verification of the readouts. Moreover, an extended information has been achieved comparing to solely EC interrogation, i.e., the grafting process of biotin and avidin was directly monitored optically displaying individual steps of an incubation procedure.
Functional plasmonic fiber for detection and on-line monitoring of organophosphorus pesticides in water or model soil samples is described. The appearance of the plasmon absorption band was realized through the deposition of a thin gold layer on the naked core of multimode optical fiber. The metalorganic frameworks (MOF-5) layer was deposited on the gold surface for the introduction of a high affinity towards the target pesticides. The MOF-5 layer affords the extraction of pesticides and their concentration primarily in the "plasmon evanescent wave" space, allowing the detection by the shift of plasmon absorption band. The growth of MOF-5 layer was confirmed using the Raman, XPS and XRD measurements. The entrapping of pesticides was checked using the Raman spectroscopy and ellipsometry, which also indicate the corresponding changes of MOF-5 refractive index. The series of further experiments demonstrate the applicability of proposed fiber sensor for detection of pesticides in soil without the false signals from surrounding media. The main advantages of proposed sensor can be attributed to simplicity, high sensitivity, low cost and the absence of organic solvents for the probe treatment.
- Publikační typ
- časopisecké články MeSH
Design and development of scale-down approaches, such as microbioreactor (μBR) technologies with integrated sensors, are an adequate solution for rapid, high-throughput and cost-effective screening of valuable reactions and/or production strains, with considerably reduced use of reagents and generation of waste. A significant challenge in the successful and widespread application of μBRs in biotechnology remains the lack of appropriate software and automated data interpretation of μBR experiments. Here, it is demonstrated how mathematical models can be usedas helpful tools, not only to exploit the capabilities of microfluidic platforms, but also to reveal the critical experimental conditions when monitoring cascade enzymatic reactions. A simplified mechanistic model was developed to describe the enzymatic reaction of glucose oxidase and glucose in the presence of catalase inside a commercial microfluidic platform with integrated oxygen sensor spots. The proposed model allowed an easy and rapid identification of the reaction mechanism, kinetics and limiting factors. The effect of fluid flow and enzyme adsorption inside the microfluidic chip on the optical sensor response and overall monitoring capabilities of the presented platform was evaluated via computational fluid dynamics (CFD) simulations. Remarkably, the model predictions were independently confirmed for μL- and mL- scale experiments. It is expected that the mechanistic models will significantly contribute to the further promotion of μBRs in biocatalysis research and that the overall study will create a framework for screening and evaluation of critical system parameters, including sensor response, operating conditions, experimental and microbioreactor designs.
Recent advances in optical sensing technologies underpin the development of high-performance, surface-sensitive analytical tools capable of reliable and precise detection of molecular targets in complex biological media in non-laboratory settings. Optical fibre sensors guide light to and from a region of interest, enabling sensitive measurements of localized environments. This positions optical fibre sensors as a highly promising technology for a wide range of biochemical and healthcare applications. However, their performance in real-world biological media is often limited by the absence of robust post-modification strategies that provide both high biorecognition and antifouling capabilities. In this study, we present the proof-of-concept antifouling and biorecognition performance of a polymer brush nano-coating synthesized at the sensing region of optical fibre long-period grating (LPG) sensors. Using a newly developed antifouling terpolymer brush (ATB) composed of carboxybetaine methacrylamide, sulfobetaine methacrylamide, and N-(2-hydroxypropyl)methacrylamide, we achieve state-of-the-art antifouling properties. The successful on-fibre ATB synthesis is confirmed through scanning electron microscopy (SEM), fluorescence microscopy, and label-free bio-detection experiments based on antibody-functionalized ATB-coated LPG optical fibres. Despite the challenges in handling optical fibres during polymerization, the resulting nano-coating retains its remarkable antifouling properties upon exposure to blood plasma and enables biorecognition element functionalization. These capabilities are demonstrated through the detection of IgG in buffer and diluted blood plasma using anti-IgG-functionalized ATB-coated sensing regions of LPG fibres in both label-based (fluorescence) and label-free real-time detection experiments. The results show the potential of ATB-coated LPG fibres for use in analytical biosensing applications.
This article presents a solution for continuous monitoring of both respiratory rate (RR) and heart rate (HR) inside Magnetic Resonance Imaging (MRI) environments by a novel ballistocardiography (BCG) fiber-optic sensor. We designed and created a sensor based on the Fiber Bragg Grating (FBG) probe encapsulated inside fiberglass (fiberglass is a composite material made up of glass fiber, fabric, and cured synthetic resin). Due to this, the encapsulation sensor is characterized by very small dimensions (30 × 10 × 0.8 mm) and low weight (2 g). We present original results of real MRI measurements (conventionally most used 1.5 T MR scanner) involving ten volunteers (six men and four women) by performing conventional electrocardiography (ECG) to measure the HR and using a Pneumatic Respiratory Transducer (PRT) for RR monitoring. The acquired sensor data were compared against real measurements using the objective Bland⁻Altman method, and the functionality of the sensor was validated (95.36% of the sensed values were within the ±1.96 SD range for the RR determination and 95.13% of the values were within the ±1.96 SD range for the HR determination) by this means. The accuracy of this sensor was further characterized by a relative error below 5% (4.64% for RR and 4.87% for HR measurements). The tests carried out in an MRI environment demonstrated that the presence of the FBG sensor in the MRI scanner does not affect the quality of this imaging modality. The results also confirmed the possibility of using the sensor for cardiac triggering at 1.5 T (for synchronization and gating of cardiovascular magnetic resonance) and for cardiac triggering when a Diffusion Weighted Imaging (DWI) is used.
- MeSH
- balistokardiografie metody MeSH
- dechová frekvence fyziologie MeSH
- elektrokardiografie MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- srdce fyziologie MeSH
- srdeční frekvence fyziologie MeSH
- technologie optických vláken metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
A practical demonstration of pH measurement in real biological samples with an in-house developed fiber-optic pH sensor system is presented. The sensor uses 8-hydroxypyrene-1,3,6-trisulfonate (HPTS) fluorescent dye as the opto-chemical transducer. The dye is immobilized in a hybrid sol-gel matrix at the tip of a tapered optical fiber. We used 405 nm and 450 nm laser diodes for the dye excitation and a photomultiplier tube as a detector. The sensor was used for the measurement of pH in human aqueous humor samples during cataract surgery. Two groups of patients were tested, one underwent conventional phacoemulsification removal of the lens while the other was subjected to femtosecond laser assisted cataract surgery (FLACS). The precision of the measurement was ±0.04 pH units. The average pH of the aqueous humor of patients subjected to FLACS and those subjected to phacoemulsification were 7.24 ± 0.17 and 7.31 ± 0.20 respectively.
- MeSH
- fakoemulzifikace * MeSH
- komorová voda MeSH
- koncentrace vodíkových iontů MeSH
- laserová terapie * MeSH
- lidé MeSH
- prospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
... Optical platforms for SPR sensors 6 -- 3.2. ... ... Theory of SPR sensors 10 -- 5.2. ... ... Long-range surface plasmons for high-performance SPR sensors 14 -- 5.5. ... ... Optical platforms for SPR sensors 15 -- 6.1. Fiber optic SPR sensors 15 -- 6.2. ... ... Integrated-optical SPR sensors 16 -- 6.3. SPR sensors for high-throughput screening 17 -- 7. ...
32 s. : il. ; 21 cm
- MeSH
- biofyzika MeSH
- biosenzitivní techniky MeSH
- mikrochemie MeSH
- optické jevy MeSH
- povrchová plasmonová rezonance MeSH
- Publikační typ
- vysokoškolské kvalifikační práce MeSH
- Konspekt
- Biochemie. Molekulární biologie. Biofyzika
- NLK Obory