parametrical functions
Dotaz
Zobrazit nápovědu
OBJECTIVE: An extension of single- and multi-channel blind deconvolution is presented to improve the estimation of the arterial input function (AIF) in quantitative dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). METHODS: The Lucy-Richardson expectation-maximization algorithm is used to obtain estimates of the AIF and the tissue residue function (TRF). In the first part of the algorithm, nonparametric estimates of the AIF and TRF are obtained. In the second part, the decaying part of the AIF is approximated by three decaying exponential functions with the same delay, giving an almost noise free semi-parametric AIF. Simultaneously, the TRF is approximated using the adiabatic approximation of the Johnson-Wilson (aaJW) pharmacokinetic model. RESULTS: In simulations and tests on real data, use of this AIF gave perfusion values close to those obtained with the corresponding previously published nonparametric AIF, and are more noise robust. CONCLUSION: When used subsequently in voxelwise perfusion analysis, these semi-parametric AIFs should give more correct perfusion analysis maps less affected by recording noise than the corresponding nonparametric AIFs, and AIFs obtained from arteries. SIGNIFICANCE: This paper presents a method to increase the noise robustness in the estimation of the perfusion parameter values in DCE-MRI.
- MeSH
- algoritmy MeSH
- arterie patologie MeSH
- kontrastní látky chemie farmakokinetika MeSH
- magnetická rezonanční tomografie * MeSH
- myši inbrední C57BL MeSH
- myši MeSH
- perfuze MeSH
- počítačová simulace MeSH
- počítačové zpracování obrazu * MeSH
- reprodukovatelnost výsledků MeSH
- vylepšení obrazu * MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The occurrence of the local generators of P3-like potentials elicited by a noise-compatibility flanker test was used to study the processing of executive functions, particularly in the frontal and temporal cortices. The test performed with arrows comprised a simpler congruent and a more difficult incongruent task. The two tasks activated the attention and several particular executive functions, i.e., working memory, time perception, initiation, and motor control of executed task. The incongruent task increased demand on executive functions, and besides the functions common for both tasks, an inhibition of automatic responses, the reversal of incorrect response tendency, the internal ordering of the correct response, and the initiation of the target-induced correct response were involved. In seven epilepsy surgery candidates (four men and three women), ranging in age from 26 to 38 years, multicontact depth electrodes were implanted in 590 cortical sites. In the two tasks, the P3-like potential sources were displayed in the mesial temporal structures, the lateral temporal neocortex, the anterior and posterior cingulate, the orbitofrontal cortex, and dorsolateral prefrontal cortex. The P3-like potentials occurred more frequently with the incongruent than with congruent stimuli in all these areas. This more frequent occurrence of P3 sources elicited by the incongruent task appeared significant in temporal lateral neocortex and orbitofrontal cortex. The executive functions are processed in a widespread frontotemporal neurocognitive network. This study confirms the involvement of the temporal neocortex in the executive functions.
- MeSH
- dospělí MeSH
- elektroencefalografie metody MeSH
- epilepsie komplikace patologie MeSH
- exekutivní funkce fyziologie MeSH
- kognitivní evokované potenciály P300 fyziologie MeSH
- kognitivní poruchy etiologie MeSH
- lidé MeSH
- mapování mozku MeSH
- neparametrická statistika MeSH
- neuropsychologické testy MeSH
- pravděpodobnost MeSH
- spánkový lalok patofyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Depresivní porucha je spojena s určitým typem kognitivního deficitu. Kognitivní deficit u deprese je charakterizován zejména narušenou pamětí, pozorností, deficitem exekutivních funkcí a sníženou slovní plynulostí. Repetitivní transkraniální magnetická stimulace (rTMS) je neinvazivní technika a ukazuje se jako potencionálně vhodný nástroj pro léčbu depresivní poruchy v jejích nejrůznějších podobách. Přesto však je potřeba zdokonalit naše znalosti o optimálních parametrech aplikace rTMS a časovém rámci pro udržení léčby. Kromě toho trvání zisků z aplikace rTMS a efektivita a bezpečnost udržovací terapie jsou stále ještě do značné míry neprozkoumány. Tato práce podává komplexní přehled dostupných informací z odborné literatury, ze které vyplývá, že rTMS lze považovat za bezpečnou metodu léčby depresivní poruchy, ale možnost uplatnění rTMS v ovlivnění jednotlivých parametrů kognitivních funkcí stále ještě představuje do značné míry neprobádanou oblast a žádá si další výzkumy.
Depression is associated with a certain kind of cognitive deficit. Cognitive deficit in depression is characterized especially by impaired memory, impaired attention, executive functions deficit and diminished verbal fluency. Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive brain technique and turns out as a pottentionally suitable tool for treatment of depression in all sorts of this disorder. In špite of that is necessary to improve our knowledge about optimal parametres of rTMS application and its time frame for maintenance of treatment. On the top of this, continuation of rTMS effect and safeness of sequel therapy are not explored very well. This study pointed to that comprehensive review of reasonable professional literatuře, which shows that rTMS is a safe method for treatment of depression, but possibilities in use rTMS in influencing of some characteristics of cognitive functionar is still not very well known and it is important to execute more research work.
- MeSH
- depresivní poruchy terapie MeSH
- finanční podpora výzkumu jako téma MeSH
- kognitivní poruchy klasifikace terapie MeSH
- lidé MeSH
- transkraniální magnetická stimulace metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
PURPOSE: The composite vascular transport function of a brain voxel consists of one convolutional component for the arteries, one for the capillaries and one for the veins in the voxel of interest. Here, the goal is to find each of these three convolutional components and the associated arterial input function. PHARMACOKINETIC MODELLING: The single voxel vascular transport functions for arteries, capillaries and veins were all modelled as causal exponential functions. Each observed multipass tissue contrast function was as a first approximation modelled as the resulting parametric composite vascular transport function convolved with a nonparametric and voxel specific multipass arterial input function. Subsequently, the residue function was used in the true perfusion equation to optimize the three parameters of the exponential functions. DECONVOLUTION METHODS: For each voxel, the parameters of the three exponential functions were estimated by successive iterative blind deconvolutions using versions of the Lucy-Richardson algorithm. The final multipass arterial input function was then computed by nonblind deconvolution using the Lucy-Richardson algorithm and the estimated composite vascular transport function. RESULTS: Simulations showed that the algorithm worked. The estimated mean transit time of arteries, capillaries and veins of the simulated data agreed with the known input values. For real data, the estimated capillary mean transit times agreed with known values for this parameter. The nonparametric multipass arterial input functions were used to derive the associated map of the arrival time. The arrival time map of a healthy volunteer agreed with known arterial anatomy and physiology. CONCLUSION: Clinically important new voxelwise hemodynamic information for arteries, capillaries and veins separately can be estimated using multipass tissue contrast functions and the iterative blind Lucy-Richardson deconvolution algorithm.
- MeSH
- algoritmy MeSH
- arterie patologie MeSH
- kapiláry * diagnostické zobrazování MeSH
- kontrastní látky * farmakokinetika MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie MeSH
- magnetická rezonanční tomografie metody MeSH
- mozek diagnostické zobrazování MeSH
- mozkový krevní oběh MeSH
- perfuzní zobrazování MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
1st ed. vii, 647 s. : il. ; 29 cm
- MeSH
- mapování mozku MeSH
- Publikační typ
- monografie MeSH
- Konspekt
- Statistika
- NLK Obory
- statistika, zdravotnická statistika
Words like yeah, okay and (al)right are fairly unspecific in their lexical semantics, and not least for this reason there is a general tendency for them to occur with highly varied and expressive prosodic patterns across languages. Here we examine in depth the prosodic forms that express eight pragmatic functions of the Czech discourse marker jasně, including resignation, reassurance, surprise, indifference or impatience. Using a collection of 172 tokens from a corpus of scripted dialogues by 30 native speakers, we performed acoustic analyses, applied classification algorithms and solicited judgments from native listeners in a perceptual experiment. There appeared to be multi-parametric differences between jasně realizations in terms of their F0, timing and intensity patterns, which gave rise to generally consistent form-function mappings. For example, resignation seems to be realized with a falling intonation contour, relatively slow tempo, long wordinitial consonant and a short word-final vowel. Although the most significant prosodic parameters used for clustering analysis involved segment durations, all pragmatic functions were expressed by patterns of multiple features.
- MeSH
- akustika řeči * MeSH
- fonace fyziologie MeSH
- jazyk (prostředek komunikace) * MeSH
- komunikace MeSH
- lidé MeSH
- percepce řeči fyziologie MeSH
- sémantika * MeSH
- verbální chování fyziologie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
Multiparametrické zobrazení pomocí 3T magnetické rezonance dovoluje lépe pochopit mechanismy změny struktury, mikrostruktury látkové výměny i perfuze tkání v souvislosti s vývojem nádorového onemocnění. Kombinací morfologického zobrazení s analýzou farmakokinetiky difuzně váženým zobrazením a spektroskopií lze blíže specifikovat tkáně a přispět tak k diferenciální diagnóze nádorů, odhadnutí jejich biologického chování i předpovědi odpovědi na terapii, případně odpovědi posoudit.
Multi-parametric imaging using 3T magnetic resonance enables to improve knowledges about mechanisms of the structural, microstructural, metabolic and perfusion changes under conditions of oncogenesis. Such as combination of morphological imaging with an analysis of pharmacokinetics, diffusion weighted imaging and spectrosco-py allows to specify tissues in detail and to support to differential diagnosis of tumours, to estimate their behaviour, and to estimate the prognosis of therapy response or to assess it.
Cieľ: Zistiť vzťahy medzi funkciou respiračných svalov objektivizovanej metódou merania oklúznych tlakov a klasickými funkčnými spirometrickými parametrami. Súbor: 51 pacientov spĺňajúci kritéria diagnózy silicosis pulmonum. Metodika: Parametre hodnotenia sily dýchacích svalov na základe hodnotenia oklúznych tlakov: ústny oklúzny tlak za 0,1 s inspíria (P0,1), respiračná kapacita (P0,1/PImax), parametre štandardného spirometrického vyšetrenia. Výsledky: Zistili sme signifikantné vzťahy medzi parametrami ústneho oklúzneho tlaku za 0,1 s inspíria (P0,1), respiračnou kapacitou (P0,1/PImax) a parametrami spirometrického vyšetrenia % VC , FEV1 a % FEV1. Záver: Na základe týchto zistení predpokladáme širšie využitie metódy merania oklúznych tlakov vo všetkých oblastiach medicíny, kde je potrebná objektivizácia funkcie respiračných svalov, vrátane rehabilitačnej medicíny. Kľúčové slová: ústny oklúzny tlak, funkčné vyšetrenie pľúc, pľúcna rehabilitácia
Objective: To assess the relationship between respiratory muscle function the occlusion pressure measuring and standard functional spirometric parameters. Group of patients: Fifty one patients fulfilling the criteria for the diagnosis of pulmonary silicosis. Methods: The evaluation of respiratory muscle strength based on occlusion the pressure measurement. Mouth occlusion pressure at 0.1 s inspiration (P0.1), respiratory capacity (P0.1 /Pimax) and standard spirometric parameters has been measured. Results: We found significant relationships between parameters of mouth occlusion pressure 0.1 s after the onset of inspiration (P0.1), respiratory capacity (P0.1/PImax) and spirometric parameters such as % VC, FEV1 and FEV1%. Conclusion: Based on our findings we suggest a wider use of measurement the occlusion pressure in all areas of clinical medicine where it is needed the objectification of respiratory muscles function including rehabilitation medicine. Keywords: mouth occlusion pressure, pulmonary function tests, pulmonary rehabilitation
- Klíčová slova
- ústní okluzní tlak dýchacích svalů,
- MeSH
- dýchací svaly * fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- neparametrická statistika MeSH
- plicní ventilace fyziologie MeSH
- respirační funkční testy * metody statistika a číselné údaje MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- silikóza diagnóza MeSH
- spirometrie statistika a číselné údaje MeSH
- ústa * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
[1st ed.] xiii, 528 s., obr.