BACKGROUND: Noninvasive diagnostic methods utilizing pulse wave measurements on the surface of the head are an important tool in diagnosing various types of cerebrovascular disease. The measurement of extraorbital pressure fluctuations reflects intraocular and intracranial pressure changes and can be used to estimate pressure changes in intracranial arteries and the collateral circulation. NEW METHOD: In this paper, we describe our patented (CZ 305757) digital device for noninvasive measuring and monitoring of orbital movements using pressure detection. We conducted preclinical tests (126 measurements on 42 volunteers) to evaluate the practical capabilities of our device. Two human experts visually assessed the quality of the pressure pulsation and discriminability among various test conditions (specifically, subject lying, sitting, and the Matas carotid occlusion test). RESULTS: The results showed that our device provided clinically relevant outcomes with a sufficient level of detail of the pulse wave and a high reliability (not less than 85%) in all clinically relevant situations. It was possible to record the effect of the Matas carotid occlusion test. COMPARISON WITH EXISTING METHOD(S): Our fully noninvasive, lightweight (185 g), portable, and wireless device provides a considerably cheaper alternative to the current diagnostic methods (e.g., transcranial ultrasound, X-ray, or MRI angiography) for specific assessment of cerebral circulation. Within a minute, it can detect the Willis circle integrity and thus eliminate the potential risks associated with the Matas test using standard EEG. CONCLUSIONS: Our device represents an improvement and a valid alternative to the current methods diagnosing regional cerebral circulation.
- MeSH
- circulus arteriosus Willisi fyziologie MeSH
- design vybavení * MeSH
- lidé MeSH
- mozkový krevní oběh fyziologie MeSH
- orbita * krevní zásobení MeSH
- pletysmografie přístrojové vybavení normy MeSH
- pulzatilní průtok fyziologie MeSH
- regionální krevní průtok fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.
Skin and membrane permeation experiments comprise an important step in the development of a transdermal or topical formulation or toxicological risk assessment. The standard method for analyzing these data relies on the linear part of a permeation profile. However, it is difficult to objectively determine when the profile becomes linear, or the experiment duration may be insufficient to reach a maximum or steady state. Here, we present a software tool for Skin And Membrane Permeation data Analysis, SAMPA, that is easy to use and overcomes several of these difficulties. The SAMPA method and software have been validated on in vitro and in vivo permeation data on human, pig and rat skin and model stratum corneum lipid membranes using compounds that range from highly lipophilic polycyclic aromatic hydrocarbons to highly hydrophilic antiviral drug, with and without two permeation enhancers. The SAMPA performance was compared with the standard method using a linear part of the permeation profile and a complex mathematical model. SAMPA is a user-friendly, open-source software tool for analyzing the data obtained from skin and membrane permeation experiments. It runs on a Microsoft Windows platform and is freely available as a Supporting file to this article.
INTRODUCTION: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. METHODS: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. RESULTS: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. CONCLUSIONS: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any preactivation, and they might cause persistently high loads and possibly overloading. Only springs with minor hysteresis, low temperature dependence of force, and a clinically useful plateau have the following clinical advantages: reduced chair time, optimal rates of tooth movement, reproducible clinical results, and conservation of anchorage.
- MeSH
- analýza zatížení zubů přístrojové vybavení MeSH
- lidé MeSH
- mechanické jevy MeSH
- mechanický stres MeSH
- nikl chemie MeSH
- nízká teplota MeSH
- ortodontické dráty * MeSH
- pružnost MeSH
- termodynamika MeSH
- testování materiálů MeSH
- titan chemie MeSH
- torze mechanická MeSH
- vysoká teplota MeSH
- zubní slitiny chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
INTRODUCTION: The aim of this study was to find out the impact of degradation and regeneration of force over time at NiTi springs on the value and course of the final acting force and to verify the possibility of using these phenomena for a directed transition to the reverse plateau and its maintaining. METHODS: Static and cyclic mechanical loadings were performed. At first unused springs were tested. Afterwards the springs were mechanically stabilized by stress cycling and finally tested again. The difference in shape of the working curves was assessed. For simulation and description of the force degradation the modified Voight model was used. RESULTS: New springs, mainly those with large hysteresis, showed a significant stress-strain curve movement and shape changes during the cycling. The effect of the stress-strain curve course change disappeared fully in the stabilized springs. Multiple loading led to an overall decrease of force value during the measurement. The effect of force degradation and regeneration over time by simple static loading varies in the range of percentage of the nominal force in the plateau area. The transition between stress-strain curve phases caused by the degradation or regeneration of the force wasn't observed in case of mechanically stabilized springs. CONCLUSIONS: Springs should be mechanically stabilized before their application. The degree of force degradation over time is insignificant for mechanically stabilized springs. Degradation or regeneration of force over time, mechanical stabilization or micromovements in the mouth don't cause any transition between individual stress-strain curve phases.
- MeSH
- časové faktory MeSH
- lidé MeSH
- nikl * MeSH
- ortodontické aparáty * MeSH
- pevnost v tahu MeSH
- pevnost v tlaku MeSH
- pružnost * MeSH
- testování materiálů MeSH
- titan * MeSH
- viskozita * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH