BACKGROUND: Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. METHODS: We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine (Sus Scrofa) and canine (Canis familiaris) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. RESULTS: Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97-164.69, animal-based odds ratio [OR]: .55, 95% CI: .23-61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35-9.55; P = .010). CONCLUSIONS: The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.
- MeSH
- incidence MeSH
- katetrizační ablace metody MeSH
- komorová tachykardie etiologie MeSH
- modely nemocí na zvířatech * MeSH
- perikard chirurgie MeSH
- prasata MeSH
- psi MeSH
- retrospektivní studie MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: The association between chronic obstructive pulmonary disease (COPD) and sudden cardiac death has not been fully elucidated. OBJECTIVE: The purpose of this study was to investigate whether decreased left ventricular ejection fraction (LVEF) can explain the increased rate of ventricular tachycardia (VT) in COPD. METHODS: This retrospective study included consecutive adult patients who underwent pulmonary function testing (PFT), Holter monitoring, and transthoracic echocardiography. COPD was correlated with the frequency of VT in a multivariate analysis that adjusted for known confounders including LVEF. Long-term all-cause mortality of patients with COPD and VT was examined. RESULTS: Of the 6351 patients included in this study (age 66 ± 15 years; 48% woman; 92% Caucasian, LVEF 59% ± 12%), 2800 (44%) had PFT indicative of COPD. VT was nearly twice as likely to occur during Holter monitoring in COPD patients (13% vs 23%; P <.001), and the severity of COPD correlated with the risk of VT (21% vs 28% vs 37% for mild-moderate, severe, and very severe COPD; P <.001). COPD and VT remained independently associated (P <.001) even after adjusting for LVEF, demographics, and comorbidities (age, sex, body mass index, hypertension, chronic kidney disease, coronary artery disease, cancer history, diabetes mellitus). COPD was associated with all-cause mortality independently of LVEF (P <.001). CONCLUSION: COPD patients are at higher risk for VT and mortality. This may not be fully attributed to the confounding effect of systolic heart failure measured by LVEF. Further studies are needed to explore the mechanistic interactions between VT and COPD in order to determine whether antiarrhythmic strategies would apply especially to patients with severe COPD.
- MeSH
- chronická obstrukční plicní nemoc komplikace epidemiologie MeSH
- echokardiografie MeSH
- elektrokardiografie ambulantní MeSH
- funkce levé komory srdeční fyziologie MeSH
- hodnocení rizik metody MeSH
- komorová tachykardie epidemiologie etiologie patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční komory diagnostické zobrazování patofyziologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Research Support, N.I.H., Extramural MeSH
- Geografické názvy
- Minnesota MeSH
PURPOSE: To demonstrate the feasibility of directional percutaneous epicardial ablation using a partially insulated catheter. METHODS: Partially insulated catheter prototypes were tested in 12 (6 canine, 6 porcine) animal studies in two centers. Prototypes had interspersed windows to enable visualization of epicardial structures with ultrasound. Epicardial unipolar ablation and ablation between two electrodes was performed according to protocol (5-60 W power, 0-60 mls/min irrigation, 78 s mean duration). RESULTS: Of 96 epicardial ablation attempts, unipolar ablation was delivered in 53.1%. Electrogram evidence of ablation, when analyzable, occurred in 75 of 79 (94.9%) therapies. Paired pre/post-ablation pacing threshold (N = 74) showed significant increase in pacing threshold post-ablation (0.9 to 2.6 mA, P < .0001). Arrhythmias occurred in 18 (18.8%) therapies (11 ventricular fibrillation, 7 ventricular tachycardia), mainly in pigs (72.2%). Coronary artery visualization was variably successful. No phrenic nerve injury was noted during or after ablation. Furthermore, there were minimal pericardial changes with ablation. CONCLUSIONS: Epicardial ablation using a partially insulated catheter to confer epicardial directionality and protect the phrenic nerve seems feasible. Iterations with ultrasound windows may enable real-time epicardial surface visualization thus identifying coronary arteries at ablation sites. Further improvements, however, are necessary.
- MeSH
- design vybavení * MeSH
- katetrizační ablace přístrojové vybavení metody MeSH
- komorová tachykardie diagnostické zobrazování chirurgie MeSH
- modely nemocí na zvířatech MeSH
- náhodné rozdělení MeSH
- nervus phrenicus zranění MeSH
- peroperační komplikace prevence a kontrola MeSH
- plocha pod křivkou MeSH
- prasata MeSH
- psi MeSH
- senzitivita a specificita MeSH
- srdeční katétry MeSH
- studie proveditelnosti MeSH
- zvířata MeSH
- Check Tag
- psi MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS: We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS: Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION: Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.
- Publikační typ
- časopisecké články MeSH
PURPOSE: The aim of this proof-of-concept study is to introduce new high-dynamic ECG technique with potential to detect temporal-spatial distribution of ventricular electrical depolarization and to assess the level of ventricular dyssynchrony. METHODS: 5-kHz 12-lead ECG data was collected. The amplitude envelopes of the QRS were computed in an ultra-high frequency band of 500-1000 Hz and were averaged (UHFQRS). UHFQRS V lead maps were compiled, and numerical descriptor identifying ventricular dyssynchrony (UHFDYS) was detected. RESULTS: An electrical UHFQRS maps describe the ventricular dyssynchrony distribution in resolution of milliseconds and correlate with strain rate results obtained by speckle tracking echocardiography. The effect of biventricular stimulation is demonstrated by the UHFQRS morphology and by the UHFDYS descriptor in selected examples. CONCLUSIONS: UHFQRS offers a new and simple technique for assessing electrical activation patterns in ventricular dyssynchrony with a temporal-spatial resolution that cannot be obtained by processing standard surface ECG. The main clinical potential of UHFQRS lies in the identification of differences in electrical activation among CRT candidates and detection of improvements in electrical synchrony in patients with biventricular pacing.
- MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory diagnostické zobrazování terapie MeSH
- echokardiografie trojrozměrná metody MeSH
- elektrokardiografie metody MeSH
- interpretace obrazu počítačem * MeSH
- lidé středního věku MeSH
- lidé MeSH
- remodelace komor fyziologie MeSH
- senioři MeSH
- srdeční resynchronizační terapie metody MeSH
- stupeň závažnosti nemoci MeSH
- výsledek terapie MeSH
- vzorkové studie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Although the hallmark of long-QT syndrome (LQTS) is abnormal cardiac repolarization, there are varying degrees of phenotypic expression and arrhythmic risk. Our aim was to evaluate the performance of a morphological T-wave analysis program in defining breakthrough LQTS arrhythmic risk beyond the QTc value. METHODS AND RESULTS: We analyzed 407 genetically confirmed patients with LQT1 (n=246; 43% men) and LQT2 (n=161; 41% men) over the mean follow-up period of 6.4±3.9 years. ECG analysis was conducted using a novel, proprietary T-wave analysis program. Time to a LQTS-associated cardiac event was analyzed using Cox proportional hazards regression methods. Twenty-three patients experienced ≥1 defined breakthrough cardiac arrhythmic events with 5- and 10-year event rates of 4% and 7%. Two independent predictors of future LQTS-associated cardiac events from the surface ECG were identified: left slope of T wave in lead V6 (hazard ratio=0.40 [0.24-0.69]; P<0.001) and T-wave center of gravity x axis (last 25% of wave) in lead I (hazard ratio=1.90 [1.21-2.99]; P=0.005), C statistic of 0.77 (0.65-0.89). When added to the QTc (C statistic 0.68 for QTc alone), discrimination improved to 0.78. Genotype analysis showed weaker association between these T-wave variables and LQT1-triggered events while these features were stronger in patients with LQT2 and significantly outperformed the QTc (C statistic, 0.82 [0.71-0.93]). CONCLUSION: Detailed morphological analysis of the T wave provides novel insights into risk of breakthrough arrhythmic events in LQTS, particularly LQT2. This observation has the potential to guide clinical decision making and further refine risk stratification.
- MeSH
- akční potenciály MeSH
- antiarytmika terapeutické užití MeSH
- časové faktory MeSH
- dítě MeSH
- dospělí MeSH
- elektrokardiografie * MeSH
- fenotyp MeSH
- genetická predispozice k nemoci MeSH
- hodnocení rizik MeSH
- Kaplanův-Meierův odhad MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- prediktivní hodnota testů MeSH
- převodní systém srdeční účinky léků patofyziologie MeSH
- proporcionální rizikové modely MeSH
- rizikové faktory MeSH
- Romanův-Wardův syndrom diagnóza farmakoterapie genetika patofyziologie MeSH
- rozdělení chí kvadrát MeSH
- srdeční frekvence účinky léků MeSH
- syndrom dlouhého QT diagnóza farmakoterapie genetika patofyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Prolongation of the QT on the surface electrocardiogram can be due to either genetic or acquired causes. Distinguishing congenital long QT syndrome (LQTS) from acquired QT prolongation has important prognostic and management implications. We aimed to investigate if quantitative T-wave analysis could provide a tool for the physician to differentiate between congenital and acquired QT prolongation. METHODS: Patients were identified through an institution-wide computer-based QT screening system which alerts the physician if the QTc ≥ 500 ms. ECGs were retrospectively analyzed with an automated T-wave analysis program. Congenital LQTS was compared in a 1:3 ratio to those with an identified acquired etiology for QT prolongation (electrolyte abnormality and/or prescription of known QT prolongation medications). Linear discriminant analysis was performed using 10-fold cross-validation to statistically test the selected features. RESULTS: The 12-lead ECG of 38 patients with congenital LQTS and 114 patients with drug-induced and/or electrolyte-mediated QT prolongation were analyzed. In lead V5 , patients with acquired QT prolongation had a shallower T wave right slope (-2,322 vs. -3,593 mV/s), greater T-peak-Tend interval (109 vs. 92 ms), and smaller T wave center of gravity on the x axis (290 ms vs. 310 ms; p < .001). These features could distinguish congenital from acquired causes in 77% of cases (sensitivity 90%, specificity 58%). CONCLUSION: T-wave morphological analysis on lead V5 of the surface ECG could successfully differentiate congenital from acquired causes of QT prolongation.
- MeSH
- diferenciální diagnóza MeSH
- elektrokardiografie metody MeSH
- lidé MeSH
- mladiství MeSH
- retrospektivní studie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- syndrom dlouhého QT vrozené diagnóza patofyziologie MeSH
- Check Tag
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Congenital long QT syndrome (LQTS) is characterized by QT prolongation. However, the QT interval itself is insufficient for diagnosis, unless the corrected QT interval is repeatedly ≥500 ms without an acquired explanation. Further, the majority of LQTS patients have a corrected QT interval below this threshold, and a significant minority has normal resting corrected QT interval values. Here, we aimed to develop and validate a novel, quantitative T wave morphological analysis program to differentiate LQTS patients from healthy controls. METHODS AND RESULTS: We analyzed a genotyped cohort of 420 patients (22±16 years, 43% male) with either LQT1 (61%) or LQT2 (39%). ECG analysis was conducted using a novel, proprietary T wave analysis program that quantitates subtle changes in T wave morphology. The top 3 discriminating features in each ECG lead were determined and the lead with the best discrimination selected. Classification was performed using a linear discriminant classifier and validated on an untouched cohort. The top 3 features were Tpeak-Tend interval, T wave left slope, and T wave center of gravity x axis (last 25% of the T wave). Lead V6 had the best discrimination. It could distinguish 86.8% of LQTS patients from healthy controls. Moreover, it distinguished 83.33% of patients with concealed LQTS from controls, despite having essentially identical resting corrected QT interval values. CONCLUSIONS: T wave quantitative analysis on the 12-lead surface ECG provides an effective, novel tool to distinguish patients with either LQT1/LQT2 from healthy matched controls. It can provide guidance while mutation-specific genetic testing is in motion for family members.
- MeSH
- elektrokardiografie metody MeSH
- genotyp MeSH
- lidé MeSH
- mladý dospělý MeSH
- počítačové zpracování signálu MeSH
- senzitivita a specificita MeSH
- syndrom dlouhého QT klasifikace diagnóza genetika MeSH
- Check Tag
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Initiation of class III anti-arrhythmic medications requires telemetric monitoring for ventricular arrhythmias and QT prolongation to reduce the risk of torsades de pointes (TdP). Heart rate-corrected QT interval (QTc) is an indicator of risk, however it is imperfect, and subtle abnormalities of repolarization have been linked with arrhythmogenesis. PURPOSE: Identification of electrocardiographic predictors of torsadogenic risk through the application of a novel T wave analysis tool. METHODS: Among all patients admitted to Mayo Clinic for initiation of dofetilide or sotalol, we identified 13 cases who developed drug-induced TdP and 26 age and sex matched controls that did not develop TdP. The immediate pre-TdP ECG of those with TdP was compared to the last ECG performed prior to hospital discharge in controls using a novel T wave program that quantified subtle changes in T wave morphology. RESULTS: The QTc and 12 T wave parameters successfully distinguished TdP cases from controls. The top performing parameters were the QTc in lead V3 (mean case vs control 480 vs 420 msec, p < 0.001, r = 0.72) and T wave right slope in lead I (mean case vs control -840.29 vs -1668.71 mV/s, p = 0.002, r = 0.45). The addition of T wave right slope to QTc improved prediction accuracy from 79 to 88 %. CONCLUSION: Our data demonstrate that, in addition to QTc, the T wave right slope is correlated strongly with TdP risk. This suggests that a computer-based repolarization measurement tool that integrates additional data beyond the QTc may identify patients with the greatest torsadogenic potential.
- MeSH
- antiarytmika škodlivé účinky MeSH
- elektrokardiografie metody MeSH
- fenethylaminy škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- prediktivní hodnota testů * MeSH
- senioři MeSH
- software * MeSH
- sotalol škodlivé účinky MeSH
- studie případů a kontrol MeSH
- sulfonamidy škodlivé účinky MeSH
- torsades de pointes chemicky indukované prevence a kontrola MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVE: To investigate a potential relationship between implantable cardioverter defibrillator (ICD) therapies and daily geomagnetic activity (GMA) recorded in a large database. PATIENTS AND METHODS: The ALTITUDE database, derived from the Boston Scientific LATITUDE remote monitoring system, was retrospectively analyzed for the frequency of ICD therapies. Daily GMA was expressed as the planetary K-index and the integrated A-index and was graded as levels I (quiet), II (unsettled), III (active), and IV (storm). RESULTS: A daily mean ± SD of 59,468±11,397 patients were monitored between January 1, 2009, and May 15, 2012. The distribution of days according to GMA was as follows: level I, 924/1231 (75%); level II, 226/1231 (18%); level III, 60/1231 (5%); and level IV, 21/1231 (2%). The daily mean ± SD numbers of ICD shocks received per 1000 active patients in the database were 1.29±0.47, 1.17±0.46, 1.03±0.37, and 0.94±0.29 on level I, II, III, and IV days, respectively; the daily mean ± SD sums of shocks and antitachycardia pacing therapies were 9.29±2.86, 8.46±2.45, 7.92±1.80, and 7.83±2.28 on quiet, unsettled, active, and storm days, respectively. A significant inverse relationship between GMA and frequency of ICD therapies was identified, with the most pronounced difference between level I and level IV days (P<.001 for shocks; P=.008 for shocks + antitachycardia pacing). CONCLUSION: In a large-scale cohort analysis, ICD therapies were delivered less frequently on days of higher GMA, confirming the previous pilot data and suggesting that higher GMA does not pose an increased risk of arrhythmias using ICD therapies as a surrogate marker. Further studies are needed to gain an in-depth understanding of the underlying mechanisms.
- MeSH
- defibrilátory implantabilní * MeSH
- elektrická defibrilace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetické jevy * MeSH
- monitorování fyziologických funkcí MeSH
- retrospektivní studie MeSH
- senioři MeSH
- srdeční arytmie patofyziologie terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH