Lyme arthritis, one of the possible late manifestations of Lyme borreliosis, predominantly affects the supporting joints and in adults most often occurs in the form of monoarthritis of the knee. Early diagnosis is based on clinical findings and serology. PCR detection of Borrelia in synovial fluid has become an integral part of the laboratory testing algorithm. The clinical presentation and inflammatory markers in Lyme arthritis can resemble septic arthritis. Determining the levels of alpha-defensins (human neutrophil peptide (HNP 1-3)) in synovial fluid by liquid chromatography is a highly sensitive method revealing the presence of inflammatory process. Between 2020 and 2022, we examined eleven patients with Lyme arthritis of the knee. We measured levels of HNP 1-3 from synovial fluid by HPLC in patients, and we compared it with the corresponding C-reactive protein (CRP) levels in paired serum samples. In patients diagnosed with Lyme arthritis, HNP 1-3 levels in synovial fluid ranged from 2.5 to 261 mg/L, with a median of 46.5 mg/L. Average serum CRP was 43 mg/L. The results show that elevated HNP 1-3 can be consistent with not only septic arthritis or systemic disease, but also with Lyme arthritis, especially in patients with negative culture and 16S PCR from synovial fluid. Final diagnosis must be verified by examination for anti-Borrelia antibodies from serum and synovial fluid. The aim of this work is to introduce an HPLC method for the determination of alpha-defensins as one of the possible diagnostic markers.
- MeSH
- alfa-defensiny * metabolismus analýza MeSH
- biologické markery * analýza MeSH
- C-reaktivní protein analýza MeSH
- dospělí MeSH
- infekční artritida mikrobiologie diagnóza imunologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- lymeská nemoc * diagnóza imunologie mikrobiologie MeSH
- senioři MeSH
- synoviální tekutina * chemie imunologie mikrobiologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY: This manuscript aims to identify an indication algorithm for the surgical treatment of radial head fractures associated with elbow dislocation. The study compares the mid-term functional outcomes of patients with multifragment radial head fracture treated by resection with the outcomes of patients treated with radial head replacement. MATERIAL AND METHODS: The cohort of 34 patients who sustained a radial head fracture at the mean age of 42.5 years (age range 20-81 years) was broken down into two groups by type of surgery. The EXT group consists of 20 patients with the radial head fracture treated by radial head resection. The END group includes 14 patients treated with the radial head replacement. In all patients, the radial head fracture was associated with elbow dislocation (type IV fracture according to the Mason-Johnston classification). The modified Kocher's surgical approach was used in all patients of both the groups. In the EXT group, resection of the fragmented radial head was performed. In the END group, the ExploR® Modular Radial Head System (Zimmer, Biomet, USA) was used, consisting of a CoCr (cobalt chromium) alloy head and a titanium stem. The pain and the range of motion of the elbow and forearm were evaluated after the completion of the outpatient rehabilitation (the mean follow-up period was 2.4 years). Simultaneously, the elbow joint stability was assessed. Radiographs were taken to detect heterotopic ossifications, proximalization of the radius, and any signs of prosthesis loosening. The frequency of reoperations was followed-up. The MEPS (Mayo Elbow Performance Score) was calculated. RESULTS: In the EXT group, the mean elbow flexion was 117.5° and the mean pronation/supination was 166.9°. In 50% of patients, the MEPS obtained was greater than 90 points, which means an excellent functional outcome. In 1 patient (5%), recurrent elbow dislocation occurred which was the reason for revision surgery (elbow transfixation with the Kirschner wires and medial collateral ligament suture). Revision surgery was also performed in 2 patients (10%) in whom not all the radial head fragments were removed. Moreover, also observed was elbow joint instability (2 patients) and temporary radial nerve paralysis (1 patient). In 1 case discrete proximalization of the radius developed. The patients in the END group showed the mean elbow flexion of 112° and the mean pronation/supination of 135°. The MEPS obtained from 69% of patients was greater than 90 points, which means an excellent outcome. The pain under load was reported by 3 patients (21%). In 5 patients (35%), the X-rays showed radiolucent zone around the stem of the prosthesis. Neither revision surgery, nor prosthesis removal has been performed yet in any patient. No instability, neurological complications or infections have been reported. In both EXT and END group heterotopic ossifications have developed in 4 patients. CONCLUSIONS: Radial head replacement compared to the radial head resection in the management of multifragment fractures associated with elbow dislocations increase the elbow and forearm stability. The group of patients with an implanted radial head prosthesis shows a higher percentage of patients achieving excellent functional outcome than the group of patients with radial head resection. KEY WORDS: radial head, elbow, fracture, dislocation, resection, prosthesis.
- MeSH
- dislokace kloubu * chirurgie MeSH
- dospělí MeSH
- fraktury hlavice a krčku vřetenní kosti MeSH
- fraktury vřetenní kosti * chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- loketní kloub * chirurgie patofyziologie MeSH
- mladý dospělý MeSH
- nestabilita kloubu * chirurgie etiologie MeSH
- poranění lokte MeSH
- rozsah kloubních pohybů MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tříštivé fraktury * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The diagnosis of joint replacement infection is a difficult clinical challenge that often occurs when the implant cannot be salvaged. We hypothesize that the pH value of synovial fluid could be an important indicator of the inflammatory status of the joint. However, in the literature, there is a lack of data on the pH changes in hip and knee joint replacements and their relation to infection and implant failure. In this study, we aimed to measure the pH levels of synovial fluid in patients with hip and knee joint replacements. We also investigated the potential of pH measurement as a diagnostic tool for joint replacement infection. In this study, we recorded the pH values to be 7.55 and 7.46 in patients where Pseudomonas aeruginosa was identified as the cause of the prosthetic joint infection. We attribute this to the different environments created by this specific bacterium. In other cases where the pH was higher, chronic mitigated infections were diagnosed, caused by strains of Staphylococcus aureus, Streptococcus agalactiase, and coagulase negative staphylococcus. MATERIALS AND METHODS: In our cohort of 155 patients with implanted hip (THA; n = 85) or knee (TKA; n = 70) joint replacements, we conducted a prospective study with a pH measurement. Out of the whole cohort, 44 patients had confirmed joint replacement infection (28.4%) (44/155). In 111 patients, infection was ruled out (71.6%) (111/155). Joint replacement infection was classified according to the criteria of the Musculoskeletal Infection Society (MSIS) from 2018. Based on the measured values, we determined the cut-off level for the probability of ongoing inflammation. We also determined the sensitivity and specificity of the measurement. RESULTS: The group of patients with infection (n = 44) had a significantly lower synovial fluid pH (pH = 6.98 ± 0.48) than the group of patients with no infection (n = 111, pH = 7.82 ± 0.29, p < 0.001). The corresponding median pH values were 7.08 for the patients with infection and 7.83 for the patients with no infection. When we determined the cut-off level of pH 7.4, the sensitivity level of infected replacements was 88.6%, and the specificity level of the measurement was 95.5%. The predictive value of a positive test was 88.6%, and the predictive value of a negative test was 95.5%. CONCLUSIONS: Our results confirm that it is appropriate to include a pH measurement in the diagnostic spectrum of hip and knee replacements. This diagnostic approach has the potential to provide continuous in vivo feedback, facilitated by specialized biosensors. The advantage of this method is the future incorporation of a pH-detecting sensor into intelligent knee and hip replacements that will assess pH levels over time. By integrating these biosensors into intelligent implants, the early detection of joint replacement infections could be achieved, enhancing proactive intervention strategies.
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY Total arthroplasty of the first metatarsophalangeal joint is one of the surgical treatment options for patients with advanced hallux rigidus. This study evaluates the pressure changes in the propulsion phase of the gait cycle using dynamic pedobarography after the total arthroplasty of the first metatarsophalangeal joint by Medin PH-Flex and their comparison with the control groups of patients with hallux rigidus and with asymptomatic patients. MATERIAL AND METHODS Dynamic pedobarograph was used to evaluate 15 first MTP joint replacements by Medin PH-Flex implants in 12 female patients, the average time since joint replacement was 3.5 years (1.5 to 5.5 years). The control group consisted of 13 forefeet in 12 patients with hallux rigidus of Grade 3 and Grade 4 according to the Coughlin classification and 17 healthy patients with no clear foot deformity, i.e. of a total of 34 forefeet. A zone for each metatarsal (M1-M5) and the big toe area (T1) were defined with the use of an integrated software. The difference between the pressure under the big toe area and the first metatarsal bone - hallux stiffness (T1-M1) and the forefoot balance parameter, i.e. the difference between the pressures under the medial and lateral half of the forefoot ((M1+M2)-(M3+M4+M5)), was obtained. The parameters were evaluated for each group during the propulsion phase of the gait, i.e. from 55% to 100% of the stance phase and from 75% to 100% of the stance phase, i.e. that part of propulsion when the greatest pressure is exerted on the big toe. RESULTS For the HS parameter (T1-M1) in 55% to 100% of the stance phase, the median value was -0.66 ± 1.22 (-1.90 to 1.45) in the control group, -0.85 ± 1.94 (-1.40 to 3.80) in patients with hallux rigidus, and -0.10 ± 1.48 (-1.30 to 2.40) in patients after the first MTP joint replacement. The median forefoot balance parameter from 55% of the stance phase was -3.48 ± 2.45 (-6.90 to 0.68) in healthy patients and -4.43 ± 2.72 (-6.98 to 0.23) in hallux rigidus patients. In patients after the joint replacement, the value was -3.00 ± 2.46 (-6.20 to 0.40). The data were statistically analysed by the Dunnett's and Tukey's multiple comparison tests. The hallux stiffness parameter showed a significant improvement after the joint replacement compared to patients with hallux rigidus (p<0.0001). No statistical significance was confirmed when comparing the joint replacement cases and the healthy patients from the control group (p=0.0007 and p=0.0010, respectively). As concerns the forefoot balance parameter, a significant difference was reported in patients with joint replacement compared to healthy patients from the control group and patients with hallux rigidus (p <0.0001). DISCUSSION The published pedobarographic studies differ in terms of the methodology used, the patient population and the parameters examined. The pedobarographic studies after the replacement of the first MTP joint or after its arthrodesis present inconclusive outcomes. According to the available literature, the joint replacement has the potential to improve mediolateral forefoot loading and to partially restore the weight-bearing function of the first ray. Our analysis of the HS parameter suggests that the MTP joint replacement can improve the big toe function compared to patients with hallux rigidus but fails to achieve the functional outcomes of healthy patients. When evaluating the forefoot balance (FB) parameter, we can observe less loading on the lateral half of the forefoot in the propulsion phase compared to hallux rigidus. Nonetheless, the joint replacement is unable to restore the physiological loading of the foot. CONCLUSIONS The first MTP joint replacement has the potential to improve forefoot function and to bring it closer to that of a healthy person, even though achieving physiological loading of the forefoot is unrealistic. Additional studies will be needed to confirm that the indication for the first MTP joint replacement is justified in hallux rigidus in terms of the effect on forefoot biomechanics. Key words: hallux rigidus, total replacement of the first MTP joint, dynamic pedobarography, footscan.
- MeSH
- biomechanika MeSH
- chůze (způsob) MeSH
- hallux rigidus * chirurgie MeSH
- lidé MeSH
- noha (od hlezna dolů) MeSH
- palec nohy * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- MeSH
- akromioklavikulární kloub patologie MeSH
- diferenciální diagnóza MeSH
- lidé MeSH
- lopatka patologie MeSH
- muskuloskeletální nemoci * diagnostické zobrazování klasifikace patologie terapie MeSH
- nemoci kloubů diagnostické zobrazování klasifikace patologie terapie MeSH
- poranění rotátorové manžety diagnostické zobrazování etiologie terapie MeSH
- ramenní kloub diagnostické zobrazování patologie MeSH
- sternoklavikulární kloub patologie MeSH
- tendinopatie diagnostické zobrazování terapie MeSH
- tortikolis chirurgie etiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
Polymethylmethacrylate (PMMA) bone cement mixed with antibiotics is used in orthopedic surgery to cope with implant-related infections which are typically associated with the formation of bacterial biofilms. Taking into account the growing bacterial resistance to current antibiotics, we examined here the efficacy of a selected antimicrobial peptide (AMP) mixed into the bone cement to inhibit bacterial adhesion and the consequent biofilm formation on its surface. In particular, we followed the formation of bacterial biofilms of methicillin-resistant Staphylococcus aureus (MRSA) on implants made from PMMA bone cement loaded with AMP composed of 12 amino acid residues. This was evaluated by CFU counting of bacteria released by sonication from the biofilms formed on their surfaces after these implants were retrieved from the infected murine femoral canals. The AMP loaded in these model implants prevented adhesion of MRSA and the subsequent formation of MRSA biofilm on the surfaces of more than 80% of these implants, whereas biofilms did form on control implants made from the plain cement. The results of our experiments performed in the murine femoral canal indicate the potential for this murine osteomyelitis model to mimic actual operations in orthopedics.
- MeSH
- adenosinmonofosfát MeSH
- aminokyseliny MeSH
- antibakteriální látky farmakologie terapeutické užití MeSH
- antimikrobiální peptidy MeSH
- biofilmy MeSH
- kostní cementy MeSH
- methicilin rezistentní Staphylococcus aureus * MeSH
- modely nemocí na zvířatech MeSH
- myši MeSH
- ortopedické výkony * MeSH
- polymethylmethakrylát chemie MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: The goal of this study was to investigate prevalence and morphometric parameters of pubic ligaments and the interpubic disk and its cavity using imaging methods for use in clinical medicine. METHODS: Pubic symphysis morphology was investigated in 652 patients (348 women and 304 men), from which 449 CT scans and 203 MR scans were available. The average age of men was 48 years and women 39 years. Investigated parameters included dimensions of the interpubic disk, visibility and width of the reinforcing ligaments, and visibility, dimensions, and location of the symphysial cavity. The results were compared with MR scans of 20 healthy volunteers and 21 dissected anatomic specimens. RESULTS: The craniocaudal, ventrodorsal, and mediolateral diameters of the pubic disk were 36 to 37.7, 14.8 to 15.2, and 2.2 to 4.2 mm in women and 42 to 42.3, 18.6 to 19, and 2.4 to 4.5 mm in men, respectively. Higher age correlated with shorter mediolateral diameter and larger craniocaudal and ventrodorsal diameters. The superior pubic ligament was visible in 93.1% of men (1.44 mm thick) and in 100% of women (1.7 mm); the inferior pubic ligament in 89.7% of men (1.74 mm) and 88% of women (1.95 mm), the anterior pubic ligament in 96.6% of men (1.5 mm) and 82% of women (1.34 mm); and the posterior pubic ligament in 65.5% of men (1.18 mm) and 63.7% of women (0.83 mm). A symphysial cavity was found in 24% of men and 22.9% of women, with craniocaudal, ventrodorsal, and mediolateral dimensions of 13, 10.7, and 3.2 mm in men and 9.5, 10.7, and 3 mm in women, respectively. CONCLUSION: The presented morphologic parameters provide an anatomic reference for diagnostics of pathologic conditions of the pubic symphysis. The following anatomic structures should be added to the official anatomic terminology: symphysial cavity (cavitas symphysialis), retropubic eminence (eminentia retropubica), anterior pubic ligament (ligamentum pubicum anterius), and posterior pubic ligament (ligamentum pubicum posterius). LEVEL OF EVIDENCE: II-III.
- MeSH
- kloubní ligamenta anatomie a histologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- os pubis diagnostické zobrazování MeSH
- počítačová rentgenová tomografie MeSH
- symphysis pubica * diagnostické zobrazování MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY Reverse total shoulder arthroplasty (RSA) can be considered a proven method for the treatment of the most severe shoulder joint affections. In this study, we present 14-year experiences of the authors with the LimaCorporate SMR® RSA system in 496 cases. MATERIAL AND METHODS Included in the study are 496 RSAs performed between 2007 and 2020. We successfully followed up 368 shoulders in 358 patients. This was a prospective study with function being evaluated preoperatively and at the last follow-up in 2020. We evaluated the range of motion in active elevation and the classic Constant Score (CS). According to this score, the pain level was also evaluated. Standard statistical methods were used with a paired t-test used for comparisons of values. RESULTS The mean follow-up in our group was 5.5 years (0.7-13.6, SD 3.22, median 4.96). Indications were: primary osteoarthritis (84), acute trauma (69), posttraumatic sequelae (79), cuff tear arthropathy (37), RA (29), chronic dislocations (18), final treatment of infectious complications (7), avascular necrosis (6), tumours (4) and TSA revisions (9). The mean post-operative CS of all patients was 71.9 (2-94, SD 11.26, median 73). The mean post-operative active elevation was 127.35° (30°-180°, SD 28.36, median 130°). The mean pain level at final follow-up was 0.65 (0-3, SD 0.65, median 1). There was a statistically significant improvement In the CS (26.9 to 71) and the final achieved elevation (48.5° to 127.35°) in all groups except acute traumas for obvious reasons. A significant decrease in pain (2.8 to 0.65) was observed in all groups. We saw no implant failures or UHMWPE component wear. DISCUSSION We compared our results with those published by other authors. When considering the functional outcomes, our results are comparable with those published previously. Compared to other studies, an interesting result is the low incidence of scapular notching. In our cohort of patients, it was only present in 10 (2.7%) cases. We attribute this to the design of the SMR® implant which meets the main criterium of a modern shoulder arthroplasty system: modularity of both glenoid components. The glenospheres are available in 36, 40 and 44mm sizes with standard and distalised options. Furthermore, the system also contains the Axioma® revision glenoid component. Humeral stems are available in a range of sizes and lengths including revision stems. The humeral body is also available in two sizes. The short variant is optimal for revision with hemiarthroplasty to reverse conversion. CONCLUSIONS During a period of 14 years, we performed 496 implantations of RSAs using the SMR® system. We evaluated 368 cases with an average follow-up of 5.5 years. During long-term follow-up we experienced no implant failures or complications indicative of any constructional insufficiencies. We saw no signs of UHMWPE liner wear. The SMR® system allows for treatment of even the most complex shoulder affections due to its high modularity. Key words: shoulder joint replacement, reverse shoulder arthroplasty, SMR®, Axioma®, outcomes, ROM, scapular notching, complication, polyethylene wear, UHMWPE.
PURPOSE OF THE STUDY Periprosthetic joint infections in total knee arthroplasty (TKA) represent one of the most limiting factors of implantation. Frequency of this complication is up to 2.5% in primary implantation. Revision TKA with the use of DAIR (Debridement, Antibiotics and Implant Retention) procedure is a widely accepted method in treating infection, but the indication criteria have not been clearly defined as yet. The lack of uniformity prevails also with respect to the surgical technique and the importance of respective techniques for successful treatment. The purpose of this study was to evaluate the factors affecting the twoyear survival of TKA after treating the infection by DAIR. MATERIAL AND METHODS We conducted a monocentric retrospective analysis involving 52 cases of infected TKA managed with DAIR in the period between 2007 and 2016. The evaluation took into account such factors as the sex, age, history of revision surgery for aseptic or septic reasons, and pathogens. The patients were divided into groups based on the McPherson criteria. As to the procedure, we monitored the effect of administered antibiotics, time interval between the manifestation of symptoms of TKA infection and surgery, exchange of modular parts, and use of pulse lavage, continual lavage, local antibiotic carrier, or combination of these techniques. Treatment failure was defined as persistent infection and transition to chronic suppressive antibiotic therapy or need for revision surgery of the respective joint due to recurrent infection of TKA, or death directly associated with the treatment of infected TKA in the follow-up period of 2 years after DAIR. The R software (Team Development Core, 2017) was used to carry out the statistical analysis. The target variable was the failure at two years after surgery. The Generalized Linear Model (GLM) was used for the binary dependent variable - the socalled logistic model with a logit link function. RESULTS 32 of 52 patients (61.5%) were successfully treated, of whom 18 women (62.1%) and 14 men (60.9%). The effect of causative agent, administered antibiotics, polyethylene insert exchange, McPherson score or history of revision surgery of the respective joint for aseptic reasons was not confirmed. The history of revision surgery for infection of the affected joint had a strong negative impact on treatment success, 10 of 13 (76.9%) implants failed as against 10 of 39 (25.6%) implants with negative history of infection. The mean time from surgery to the manifestation of infection was 5.9 weeks (0.5-47.5). When surgery was performed within 2 weeks from the manifestation of infection, 1 of 15 (6.7%) cases failed. In case of a later surgery, 19 of 37 (51.4%) cases failed. As concerns the used surgical technique, 60% (9/15) failure was reported in case of the combination of pulse lavage and continual lavage, 36.4% (4/11) in case of the combination of pulse lavage and local antibiotic carrier, 25% (4/16) in case of separate continual lavage, and 66.7% (2/3) in case of continual lavage with local antibiotic carrier. DISCUSSION The importance of individual factors in revision surgery of periprosthetic joint infections of TKA remains unclear. The world literature indicates as a major negative effect the time factor, the positive history of infection of the affected implant, or other previous revision surgery for aseptic reasons. Ambiguous results are achieved in assessing the effect of the pathogen, administered antibiotics or presence of fistula, the statistical significance of which has not been confirmed in our study. Questionable is also the importance of individual surgical techniques. CONCLUSIONS DAIR is a suitable method in treating infections of stable TKA without the history of revision surgery for infection. The surgery should be performed within 2 weeks from the manifestation of symptoms. Key words: debridement, antibiotics, infection, implant retention, total knee arthroplasty.
- MeSH
- antibakteriální látky terapeutické užití MeSH
- debridement MeSH
- infekce spojené s protézou * chirurgie MeSH
- lidé MeSH
- míra přežití MeSH
- reoperace MeSH
- retrospektivní studie MeSH
- totální endoprotéza kolene * škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ