- MeSH
- alkoholické nemoci jater * diagnostické zobrazování MeSH
- játra diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- magnetické pole MeSH
- modely nemocí na zvířatech MeSH
- myši MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- komentáře MeSH
- úvodníky MeSH
- MeSH
- funkce levé komory srdeční MeSH
- kardiovaskulární systém * MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie MeSH
- magnetická rezonanční tomografie MeSH
- srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- dopisy MeSH
Preoperative clinical MRI protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this second part, we review magnetic resonance spectroscopy (MRS), chemical exchange saturation transfer (CEST), susceptibility-weighted imaging (SWI), MRI-PET, MR elastography (MRE), and MR-based radiomics applications. The first part of this review addresses dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) MRI, arterial spin labeling (ASL), diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting (MRF). EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.
- MeSH
- gliom * diagnostické zobrazování chirurgie patologie MeSH
- kontrastní látky MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie metody MeSH
- magnetická rezonanční tomografie * metody MeSH
- nádory mozku * diagnostické zobrazování chirurgie patologie MeSH
- předoperační období MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH
Preoperative clinical magnetic resonance imaging (MRI) protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation or lack thereof. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this first part, we discuss dynamic susceptibility contrast and dynamic contrast-enhanced MRI, arterial spin labeling, diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting. The second part of this review addresses magnetic resonance spectroscopy, chemical exchange saturation transfer, susceptibility-weighted imaging, MRI-PET, MR elastography, and MR-based radiomics applications. Evidence Level: 3 Technical Efficacy: Stage 2.
- MeSH
- difuzní magnetická rezonance MeSH
- gliom * diagnostické zobrazování chirurgie patologie MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie metody MeSH
- magnetická rezonanční tomografie metody MeSH
- nádory mozku * diagnostické zobrazování chirurgie patologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND: Ultra-high field magnetic resonance imaging (MRI) has obvious advantages in acquiring high-resolution images. 7 T MRI has been clinically approved and 21.1 T MRI has also been tested on rodents. PURPOSE: To examine the effects of ultra-high field on mice behavior and neuron activity. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: Ninety-eight healthy C57BL/6 mice and 18 depression model mice. FIELD STRENGTH: 11.1-33.0 T SMF (static magnetic field) for 1 hour and 7 T for 8 hours. Gradients were not on and no imaging sequence was used. ASSESSMENT: Open field test, elevated plus maze, three-chambered social test, Morris water maze, tail suspension test, sucrose preference test, blood routine, biochemistry examinations, enzyme-linked immunosorbent assay, immunofluorescent assay. STATISTICAL TESTS: The normality of the data was assessed by Shapiro-Wilk test, followed by Student's t test or the Mann-Whitney U test for statistical significance. The statistical cut-off line is P < 0.05. RESULTS: Compared to the sham group, healthy C57/6 mice spent more time in the center area (35.12 ± 4.034, increased by 47.19%) in open field test and improved novel index (0.6201 ± 0.02522, increased by 16.76%) in three-chambered social test a few weeks after 1 hour 11.1-33.0 T SMF exposure. 7 T SMF exposure for 8 hours alleviated the depression state of depression mice, including less immobile time in tail suspension test (58.32% reduction) and higher sucrose preference (increased by 8.80%). Brain tissue analysis shows that 11.1-33.0 T and 7 T SMFs can increase oxytocin by 164.65% and 36.03%, respectively. Moreover, the c-Fos level in hippocampus region was increased by 14.79%. DATA CONCLUSION: 11.1-33.0 T SMFs exposure for 1 hour or 7 T SMF exposure for 8 hours did not have detrimental effects on healthy or depressed mice. Instead, these ultra-high field SMFs have anti-depressive potentials. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.
BACKGROUND: The SIOP-Renal Tumor Study Group (RTSG) does not advocate invasive procedures to determine histology before the start of therapy. This may induce misdiagnosis-based treatment initiation, but only for a relatively small percentage of approximately 10% of non-Wilms tumors (non-WTs). MRI could be useful for reducing misdiagnosis, but there is no global consensus on differentiating characteristics. PURPOSE: To identify MRI characteristics that may be used for discrimination of newly diagnosed pediatric renal tumors. STUDY TYPE: Consensus process using a Delphi method. POPULATION: Not applicable. FIELD STRENGTH/SEQUENCE: Abdominal MRI including T1- and T2-weighted imaging, contrast-enhanced MRI, and diffusion-weighted imaging at 1.5 or 3 T. ASSESSMENT: Twenty-three radiologists from the SIOP-RTSG radiology panel with ≥5 years of experience in MRI of pediatric renal tumors and/or who had assessed ≥50 MRI scans of pediatric renal tumors in the past 5 years identified potentially discriminatory characteristics in the first questionnaire. These characteristics were scored in the subsequent second round, consisting of 5-point Likert scales, ranking- and multiple choice questions. STATISTICAL TESTS: The cut-off value for consensus and agreement among the majority was ≥75% and ≥60%, respectively, with a median of ≥4 on the Likert scale. RESULTS: Consensus on specific characteristics mainly concerned the discrimination between WTs and non-WTs, and WTs and nephrogenic rest(s) (NR)/nephroblastomatosis. The presence of bilateral lesions (75.0%) and NR/nephroblastomatosis (65.0%) were MRI characteristics indicated as specific for the diagnosis of a WT, and 91.3% of the participants agreed that MRI is useful to distinguish NR/nephroblastomatosis from WT. Furthermore, all participants agreed that age influenced their prediction in the discrimination of pediatric renal tumors. DATA CONCLUSION: Although the discrimination of pediatric renal tumors based on MRI remains challenging, this study identified some specific characteristics for tumor subtypes, based on the shared opinion of experts. These results may guide future validation studies and innovative efforts. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3.
BACKGROUND: Concerns over gadolinium (Gd) retention encourage the use of lower Gd doses. However, lower Gd doses may compromise imaging performance. Higher relaxivity gadobenate may be suited to reduced dose protocols. PURPOSE: To compare 0.05 mmol/kg and 0.1 mmol/kg gadobenate in patients undergoing enhanced MRI of the central nervous system (CNS). STUDY TYPE: Retrospective, multicenter. POPULATION: Three hundred and fifty-two patients receiving 0.05 (n = 181) or 0.1 (n = 171) mmol/kg gadobenate. FIELD STRENGTH/SEQUENCES: 1.5 T and 3.0 T/precontrast and postcontrast T1-weighted spin echo/fast spin echo (SE/FSE) and/or gradient echo/fast field echo (GRE/FFE); precontrast T2-weighted FSE and T2-FLAIR. ASSESSMENT: Images of patients with extra-axial lesions at 1.5 T or any CNS lesion at 3.0 T were reviewed by three blinded, independent neuroradiologists for qualitative (lesion border delineation, internal morphology visualization, contrast enhancement; scores from 1 = poor to 4 = excellent) and quantitative (lesion-to-brain ratio [LBR], contrast-to-noise ratio [CNR]; SI measurements at regions-of-interest on lesion and normal parenchyma) enhancement measures. Noninferiority of 0.05 mmol/kg gadobenate was determined for each qualitative endpoint if the lower limit of the 95% confidence interval (CI) for the difference in precontrast + postcontrast means was above a noninferiority margin of -0.4. STATISTICAL TESTS: Student's t-test for comparison of mean qualitative endpoint scores, Wilcoxon signed rank test for comparison of LBR and CNR values; Wilcoxon rank sum test for comparison of SI changes. Tests were significant for P < 0.05. RESULTS: The mean change from precontrast to precontrast + postcontrast was significant for all endpoints. Readers 1, 2, and 3 evaluated 304, 225, and 249 lesions for 0.05 mmol/kg gadobenate, and 382, 309, and 298 lesions for 0.1 mmol/kg gadobenate. The lower limit of the 95% CI was above -0.4 for all comparisons. Significantly, higher LBR and CNR was observed with the higher dose. DATA CONCLUSION: 0.05 mmol/kg gadobenate was noninferior to 0.1 mmol/kg gadobenate for lesion visualization. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.
- MeSH
- diethylentriaminpentaacetát gadolinia MeSH
- kontrastní látky MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- meglumin analogy a deriváty MeSH
- mozek diagnostické zobrazování MeSH
- nádory mozku * MeSH
- organokovové sloučeniny * MeSH
- retrospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: In Wilson's disease (WD), demyelination, rarefaction, gliosis, and iron accumulation in the deep gray matter cause opposing effects on T2 -weighted MR signal. However, the degree and interplay of these changes in chronically treated WD patients has not been quantitatively studied. PURPOSE: To compare differences in brain multiparametric mapping between controls and chronically treated WD patients with neurological (neuro-WD) and hepatic (hep-WD) forms to infer the nature of residual WD neuropathology. STUDY TYPE: Cross-sectional. POPULATION/SUBJECTS: Thirty-eight WD patients (28 neuro-WD, 10 hep-WD); 26 healthy controls. FIELD STRENGTH/SEQUENCE: 3.0T: susceptibility, T2 *, T2 , T1 relaxometry; 1.5T: T2 , T1 relaxometry. ASSESSMENT: The following 3D regions of interest (ROIs) were manually segmented: globus pallidus, putamen, caudate nucleus, and thalamus. Mean bulk magnetic susceptibility, T2 *, T2 , and T1 relaxation times were calculated for each ROI. STATISTICAL TESTS: The effect of group (neuro-WD, hep-WD, controls) and age was assessed using a generalized least squares model with different variance for each ROI and quantitative parameter. A general linear hypothesis test with Tukey adjustment was used for post-hoc between-group analysis; P < 0.05 was considered significant. RESULTS: Susceptibility values were higher in all ROIs in neuro-WD compared to controls and hep-WD (P < 0.001). In basal ganglia, lower T2 and T2 * were found in neuro-WD compared to controls (P < 0.01) and hep-WD (P < 0.05) at 3.0T. Much smaller intergroup differences for T2 in basal ganglia were observed at 1.5T compared to 3.0T. In the thalamus, increased susceptibility in neuro-WD was accompanied by increased T1 at both field strengths (P < 0.001 to both groups), and an increased T2 at 1.5T only (P < 0.001 to both groups). DATA CONCLUSION: We observed significant residual brain MRI abnormalities in neuro-WD but not in hep-WD patients on chronic anticopper treatment. Patterns of changes were suggestive of iron accumulation in the basal ganglia and demyelination in the thalamus; 3.0T was more sensitive for detection of the former and 1.5T of the latter abnormality. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;51:1829-1835.
BACKGROUND: Omega-3 (n-3) fatty acids (FA) play and important role in neural development and other metabolic diseases such as obesity and diabetes. The knowledge about the in vivo content and distribution of n-3 FA in human body tissues is not well established and the standard quantification of FA is invasive and costly. PURPOSE: To detect omega-3 (n-3 CH3 ) and non-omega-3 (CH3 ) methyl group resonance lines with echo times up to 1200 msec, in oils, for the assessment of n-3 FA content, and the n-3 FA fraction in adipose tissue in vivo. STUDY TYPE: Prospective technical development. POPULATION: Three oils with different n-3 FA content and 24 healthy subjects. FIELD STRENGTH/SEQUENCE: Single-voxel MR spectroscopy (SVS) with a point-resolved spectroscopy (PRESS) sequence with an echo time (TE) of 1000 msec at 7 T. ASSESSMENT: Knowledge about the J-coupling evolution of both CH3 resonances was used for the optimal detection of the n-3 CH3 resonance line at a TE of 1000 msec. The accuracy of the method in oils and in vivo was validated from a biopsy sample with gas chromatography analysis. STATISTICAL TESTS: SVS data were compared to gas chromatography with the Pearson correlation coefficient. RESULTS: T2 relaxation times in oils were assessed as follows: CH2 , 65 ± 22 msec; CH3 , 325 ± 7 msec; and n-3 CH3 , 628 ± 34 msec. The n-3 FA fractions from oil phantom experiments (n = 3) were in agreement with chromatography analysis and the comparison of in vivo obtained data with the results of chromatography analysis (n = 5) yielded a significant correlation (P = 0.029). DATA CONCLUSION: PRESS with ultralong-TE can detect and quantify the n-3 CH3 signal in vivo at 7 T. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:71-82.
- MeSH
- dospělí MeSH
- fantomy radiodiagnostické MeSH
- kyseliny mastné omega-3 chemie MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční spektroskopie * MeSH
- plynová chromatografie s hmotnostně spektrometrickou detekcí MeSH
- počítačová simulace MeSH
- podkožní tuk diagnostické zobrazování MeSH
- poměr signál - šum MeSH
- prospektivní studie MeSH
- senioři MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH