On-line SPE–HPLC Dotaz Zobrazit nápovědu
A new on-line SPE-HPLC method using fused-core columns for on-line solid phase extraction and large volume sample injection for increasing the sensitivity of detection was developed for the determination of insecticides fenoxycarb and cis-, trans-permethrin in surface waters. The separation was carried out on fused-core column Phenyl-Hexyl (100×4.6 mm), particle size 2.7 µm with mobile phase acetonitrile:water in gradient mode at flow rate 1.0 mL min(-1), column temperature 45°C. Large volume sample injection (1500 µL) to the extraction dimension using short precolumn Ascentis Express RP C-18 (5×4.6 mm); fused-core particle size 2.7 µm allowed effective sample preconcentration and efficient ballast sample matrix removal. The washing mobile phase consisting of a mixture of acetonitrile:water; 30:70, (v/v) was pumped at flow rate of 0.5 mL min(-1) through the extraction precolumn to the waste. Time of the valve switch for transferring the preconcentrated sample zone from the extraction to the separation column was set at 3rd min. Elution of preconcentrated insecticides from the extraction precolumn and separation on the analytical column was performed in gradient mode. Linear gradient elution started from 40% of acetonitrile at time of valve switch from SPE column (3rd min) to 95% of acetonitrile at 7th min. Synthetic dye sudan I was chosen as an internal standard. UV detection at wavelength 225 nm was used and the method reached the limits of detection (LOD) at ng mL(-1) levels for both insecticides. The method showing on-line sample pretreatment and preconcentration with highly sensitive determination of insecticides was applied for monitoring of fenoxycarb and both permethrin isomers in different surface water samples in Czech Republic. The time of whole analysis including on-line extraction, interferences removal, chromatography separation and system equilibration was less than 8 min.
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- extrakce na pevné fázi MeSH
- fenylkarbamáty analýza MeSH
- insekticidy analýza MeSH
- jezera analýza MeSH
- monitorování životního prostředí MeSH
- on-line systémy MeSH
- permethrin analýza MeSH
- řeky chemie MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
A new fast and sensitive method based on on-line solid-phase extraction on a fused-core precolumn coupled to liquid chromatography with fluorescence detection has been developed for ochratoxin A (OTA) and citrinin (CIT) determination in lager beer samples. Direct injection of 100 μL filtered beer samples into an on-line SPE-HPLC system enabled fast and effective sample extraction including separation in less than 6 min. Preconcentration of OTA and CIT from beer samples was performed on an Ascentis Express RP C18 guard column (5 × 4.6 mm), particle size 2.7 μm, with a mobile phase of methanol/0.5% aqueous acetic acid pH 2.8 (30:70, v/v) at a flow rate of 2.0 mL min(-1). The flow switch from extraction column to analytical column in back-flush mode was set at 2.0 min and the separation was performed on the fused-core column Ascentis Express Phenyl-Hexyl (100 × 4.6 mm), particle size 2.7 μm, with a mobile phase acetonitrile/0.5% aqueous acetic acid pH 2.8 in a gradient elution at a flow rate of 1.0 mL min(-1) and temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 335/497 nm. The accuracy of the method, defined as the mean recoveries of OTA and CIT from light and dark beer samples, was in the range 98.3-102.1%. The method showed high sensitivity owing to on-line preconcentration; LOQ values were found to be 10 and 20 ng L(-1) for OTA and CIT, respectively. The found values of OTA and CIT in all tested light, dark and wheat beer samples were significantly below the maximum tolerable limits (3.0 μg kg(-1) for OTA and 2000 μg kg(-1) for CIT) set by the European Union.
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
In this work, an on-line SPE-HPLC method with spectrophotometric detection was developed for the determination of coumarins in complex samples. For the on-line cleanup of samples, a molecularly imprinted polymer was packed into the column cartridge and coupled directly with HPLC (MISPE-HPLC) using a column switching system. The separation of coumarins was performed on a C18 core-shell column (100×4.6mm, 5μm) with a mobile phase consisting of 0.3% acetic acid/acetonitrile with gradient elution at a flow-rate of 1mLmin-1. The total time of the whole analytical run, including the extraction step, was 13.25min. The on-line MISPE-HPLC method was optimized and validated. The results showed good linearity (0.10-100μgmL-1) with correlation coefficients higher than 0.99. The LOD values were from 0.03 to 0.15μgmL-1. The proposed method was successfully applied for analysis of real samples (Cassia cinnamon, chamomile tea, and Tokaj specialty wines) and obtained recoveries varied from 78.7% to 112.2% with an RSD less than 9%.
A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 µl sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 µg L(-1), and limits of quantification from 18.4 to 29.7 µg L(-1), while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 µg L(-1) in the river Elbe and up to 34.53 µg L(-1) in the closed lakes samples.
- MeSH
- chemické látky znečišťující vodu analýza MeSH
- chromatografie kapalinová MeSH
- extrakce na pevné fázi metody MeSH
- insekticidy analýza MeSH
- jezera MeSH
- karbamáty analýza MeSH
- monitorování životního prostředí metody MeSH
- on-line systémy MeSH
- organické látky analýza MeSH
- pyrethriny analýza MeSH
- řeky MeSH
- reprodukovatelnost výsledků MeSH
- spektrofotometrie ultrafialová MeSH
- voda chemie MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
Polycaprolactone composite nanofibers coated with a polydopamine layer are introduced as a new type of absorption material for on-line solid phase extraction (SPE) in chromatographic system. A hybrid technology combining the electrospinning and melt blowing was used for the preparation of 3D-structured microfiber/nanofibrous polycaprolactone composite. The dopamine coating was then applied to functionalize the micro/nanofibers. Polydopamine-coated polycaprolactone fibers were tested as an extraction phase in on-line SPE prior to HPLC separation and UV detection. Four groups of biologically active substances including bisphenols (Bisphenol S, Bisphenol AF, Bisphenol A, Bisphenol C, Bisphenol AP, Bisphenol Z, Bisphenol BP, and Bisphenol M), betablockers (Timolol, Metoprolol, Labetalol, and Propranolol), nonsteroidal antiphlogistic drugs (Salicylic acid, Ketoprofen, Naproxen, Indomethacin, Diclofenac, Ibuprophen, and Meclofenamic acid), and phenolic acids (Chlorogenic acid, Caffeic acid, Sinapic acid, m-Coumaric acid, Benzoic acid, and Cinnamic acid) were used as the model analytes. Neat and coated fibers were compared and applied as sorbents for the on-line extraction set-up. Both materials produced good extraction potential for the determination of bisphenols and nonsteroidal drugs in model biological and environmental samples including river water, human urine, and blood serum. However, the polydopamine layer significantly increased the extraction efficiency of polar drugs. Typical repeatability of on-line extraction procedure on polydopamine coated fibers was in the range 0.12-4.11% for bisphenols, 0.55-1.41% for antiphlogistic drugs, 0.59-2.52% for phenolic acids, and 1.01-1.65% for betablockers. Graphical abstract Schematic representation of polycaprolactone composite nanofibers coated with a polydopamine layer as an advanced absorption material for on-line solid phase extraction in chromatography.
- MeSH
- antiflogistika nesteroidní analýza izolace a purifikace MeSH
- beta blokátory analýza izolace a purifikace MeSH
- chemické látky znečišťující vodu analýza izolace a purifikace MeSH
- cinnamáty analýza izolace a purifikace MeSH
- extrakce na pevné fázi metody MeSH
- fenoly analýza izolace a purifikace MeSH
- indoly chemie MeSH
- nanovlákna chemie MeSH
- polyestery chemie MeSH
- polymerizace MeSH
- polymery chemie MeSH
- řeky chemie MeSH
- reprodukovatelnost výsledků MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
According to the EU legislation, ochratoxin A contamination is controlled in wines. Tokaj wine is a special type of sweet wine produced from botrytized grapes infected by "noble rot" Botrytis cinerea. Although a high contamination was reported in sweet wines and noble rot grapes could be susceptible to coinfection with other fungi, including ochratoxigenic species, no screening of Tokaj wines for mycotoxin contamination has been carried out so far. Therefore, we developed an analytical method for the determination of ochratoxin A (OTA) and ochratoxin B (OTB) involving online SPE coupled to HPLC-FD using column switching to achieve the fast and sensitive control of mycotoxin contamination. The method was validated with recoveries ranging from 91.6% to 99.1% with an RSD less than 2%. The limits of quantification were 0.1 and 0.2 µg L-1 for OTA and OTB, respectively. The total analysis time of the online SPE-HPLC-FD method was a mere 6 min. This high throughput enables routine analysis. Finally, we carried out an extensive investigation of the ochratoxin contamination in 59 Slovak Tokaj wines of 1959-2017 vintage. Only a few positives were detected. The OTA content in most of the checked wines did not exceed the EU maximum tolerable limit of 2 µg L-1, indicating a good quality of winegrowing and storing.
- MeSH
- analýza potravin metody MeSH
- chromatografie kapalinová MeSH
- extrakce na pevné fázi MeSH
- kontaminace potravin analýza MeSH
- ochratoxiny analýza MeSH
- řízení kvality MeSH
- senzitivita a specificita MeSH
- víno analýza MeSH
- Vitis chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH