The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) with the European Society of Gynaecological Oncology (ESGO) jointly developed clinically relevant and evidence-based statements on performing ultrasound-guided biopsies in gynecological oncology. The objective of this Consensus Statement is to assist clinicians, including gynecological sonographers, gynecological oncologists and radiologists, to achieve the best standards of practice in ultrasound-guided biopsy procedures. ISUOG/ESGO nominated a multidisciplinary international group of 16 experts who have demonstrated leadership in the use of ultrasound-guided biopsy in the clinical management of patients with gynecological cancer. In addition, two early-career gynecological fellows were nominated to participate from the European Network of Young Gynae Oncologists (ENYGO) within ESGO and from ISUOG. The group also included a patient representative from the European Network of Gynaecological Cancer Advocacy Groups. The document is divided into six sections: (1) general recommendations; (2) image-guided biopsy (imaging guidance, sampling methods); (3) indications and contraindications; (4) technique; (5) reporting; and (6) training and quality assurance. To ensure that the statements are evidence-based, the current literature was reviewed and critically appraised. Preliminary statements were drafted based on this review of the literature. During a conference call, the whole group discussed each preliminary statement, and a first round of voting was carried out. The group achieved consensus on all 46 preliminary statements without the need for revision. These ISUOG/ESGO statements on ultrasound-guided biopsy in gynecological oncology, together with a summary of the evidence supporting each statement, are presented herein. This Consensus Statement is supplemented by detailed narrated videoclips presenting different approaches and indications for ultrasound-guided biopsy, a patient leaflet, and an extended version which includes a detailed review of the evidence.
- MeSH
- gynekologie normy MeSH
- intervenční ultrasonografie * metody normy MeSH
- konsensus MeSH
- lékařská onkologie normy MeSH
- lidé MeSH
- nádory ženských pohlavních orgánů * patologie diagnostické zobrazování MeSH
- ultrazvukem navigovaná biopsie * metody normy MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- konsensus - konference MeSH
- přehledy MeSH
The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) with the European Society of Gynaecological Oncology (ESGO) jointly developed clinically relevant and evidence-based statements on performing ultrasound-guided biopsies in gynecological oncology. The objective of this Consensus Statement is to assist clinicians, including gynecological sonographers, gynecological oncologists and radiologists, to achieve the best standards of practice in ultrasound-guided biopsy procedures. ISUOG/ESGO nominated a multidisciplinary international group of 16 experts who have demonstrated leadership in the use of ultrasound-guided biopsy in the clinical management of patients with gynecological cancer. In addition, two early-career gynecological fellows were nominated to participate from the European Network of Young Gynae Oncologists (ENYGO) within ESGO and from ISUOG. The group also included a patient representative from the European Network of Gynaecological Cancer Advocacy Groups. The document is divided into six sections: (1) general recommendations; (2) image-guided biopsy (imaging guidance, sampling methods); (3) indications and contraindications; (4) technique; (5) reporting; and (6) training and quality assurance. To ensure that the statements are evidence-based, the current literature was reviewed and critically appraised. Preliminary statements were drafted based on this review of the literature. During a conference call, the whole group discussed each preliminary statement, and a first round of voting was carried out. The group achieved consensus on all 46 preliminary statements without the need for revision. These ISUOG/ESGO statements on ultrasound-guided biopsy in gynecological oncology, together with a summary of the evidence supporting each statement, are presented herein. This Consensus Statement is supplemented by detailed narrated videoclips presenting different approaches and indications for ultrasound-guided biopsy, a patient leaflet, and an extended version which includes a detailed review of the evidence. © 2025 The Authors. Published by John Wiley & Sons Ltd on behalf of The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) and by Elsevier Inc. on behalf of the European Society of Gynaecological Oncology and the International Gynecologic Cancer Society.
- MeSH
- gynekologie * normy MeSH
- intervenční ultrasonografie * metody normy MeSH
- konsensus MeSH
- lékařská onkologie normy MeSH
- lidé MeSH
- nádory ženských pohlavních orgánů * patologie diagnostické zobrazování MeSH
- společnosti lékařské MeSH
- ultrazvukem navigovaná biopsie * metody normy MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- konsensus - konference MeSH
- práce podpořená grantem MeSH
- směrnice pro lékařskou praxi MeSH
BACKGROUND/AIM: To compare the diagnostic reliability, accuracy and safety of ultrasound-guided biopsy (Tru-Cut biopsy) and ascites puncture in patients with a primarily inoperable malignant ovarian tumor. PATIENTS AND METHODS: This is a retrospective analysis of the studied methods in consecutively examined patients and a prospective validation of these methods. 79 women with a suspected primarily inoperable ovarian tumor underwent Tru-Cut biopsies and were included in the ultrasound-guided biopsy group. In addition, 55 patients after ascites puncture were enrolled in the comparison group. Both procedures were performed in 48 patients for the prospective validation. RESULTS: Significant differences in favour of ultrasound-guided biopsy were found in all studied variables (malignancy confirmation 72.9% vs. 95.8%, tumor origin 52.1% vs. 89.6%, histologic subtype 43.8% vs. 85.4% and accuracy, i.e. agreement of preoperative and definitive diagnosis 43.7% vs. 95.4%). CONCLUSION: Ultrasound-guided biopsy is an accurate, reliable, safe and minimally invasive method. Owing to the high reliability and accuracy, it has the capacity to replace ascites puncture with cytologic examination or a more invasive method (laparoscopy, laparotomy) for adequate tumor sampling.
- MeSH
- ascites patologie MeSH
- cytodiagnostika MeSH
- histocytochemie MeSH
- lidé MeSH
- nádory vaječníků diagnóza MeSH
- punkce * metody MeSH
- reprodukovatelnost výsledků MeSH
- retrospektivní studie MeSH
- ultrasonografie * metody MeSH
- ultrazvukem navigovaná biopsie * metody normy MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Software-based MRI/TRUS fusion biopsy depends on the coordination of several steps, and inter-examiner differences could influence the results. The aim of this bicentric prospective study was to compare the detection rates of MRI/TRUS fusion targeted biopsy (TG) and systematic biopsy (SB), and the detection rates of examiners with different levels of previous experience in prostate biopsy. METHODS: A total of 419 patients underwent MRI based on a suspicion of prostate cancer with elevated PSA levels. MRI was positive in 395 patients (221 in the first biopsy group [FB] and 174 in the repeated biopsy group [RB]). A subsequent TG, followed by a SB, was performed on these patients by four different examiners. RESULTS: In the detection of clinically significant prostate cancer, a significant difference was found for TG+SB against SB in the RB group (35.1% vs. 25.3%, P=0.047). In the detection of clinically insignificant prostate cancer, the SB had a significantly higher detection rate than TG in both subgroups (FB: 11.9% vs. 4.7%, P=0.008; RB: 13.8% vs. 6.9%, P=0.034). A significant difference was found between the four examiners in the FB for TG (P=0.028), SB (P=0.036), and TG+SB (P=0.017). CONCLUSION: MRI/TRUS TG in combination with SB had significantly higher detection rates than SB in the RB group only. Differences in detection rates between examiners were dependent on the level of previous experience with TRUS guided biopsy.
- MeSH
- intervenční ultrasonografie metody normy MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody normy MeSH
- nádory prostaty diagnóza patofyziologie MeSH
- palpační vyšetření konečníku metody normy MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- směrnice pro lékařskou praxi jako téma * MeSH
- ultrazvukem navigovaná biopsie metody normy MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
- MeSH
- adjuvantní chemoterapie metody normy MeSH
- chirurgie trávicího traktu metody normy MeSH
- dospělí MeSH
- endosonografie MeSH
- gastrointestinální stromální tumory diagnóza epidemiologie patologie terapie MeSH
- incidence MeSH
- laparoskopie metody normy MeSH
- lékařská onkologie metody normy MeSH
- lidé MeSH
- následná péče metody normy MeSH
- počítačová rentgenová tomografie MeSH
- protokoly protinádorové kombinované chemoterapie normy terapeutické užití MeSH
- resekční okraje MeSH
- společnosti lékařské normy MeSH
- staging nádorů MeSH
- střeva diagnostické zobrazování patologie chirurgie MeSH
- svépomocné skupiny normy MeSH
- ultrazvukem navigovaná biopsie metody normy MeSH
- výsledek terapie MeSH
- žaludek diagnostické zobrazování patologie chirurgie MeSH
- zapojení pacienta * MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- směrnice pro lékařskou praxi MeSH
- Geografické názvy
- Evropa MeSH