The traditional non-invasive method for the early detection of arteriosclerosis is the brachial-ankle pulse wave velocity (PWV); however, this method is significantly influenced by blood pressure (BP) changes. Recently, a new non-invasive method for the arterial stiffness assessment was developed – the cardio-ankle vascular index (CAVI). This method has been shown to be unaffected by BP variations and thus it could be recommended for wide clinical use, including large population studies. The aim of this paper was to evaluate the CAVI in a sample of Czech adult population. A group of 121 healthy subjects (aged from 20 to >70 years) was examined using the newest type of non-invasive monitoring system VaSera® 1500 (Fukuda Denshi Co., Tokyo, Japan). This control group was then compared with 3 groups of patients with selected lifestyle-related diseases: coronary artery disease (CAD; n = 74), diabetes mellitus (DM; n = 36), and hypertension (HT; n = 58). The statistical analysis showed a significant difference in the CAVI parameter between healthy subjects and patients with coronary artery disease, diabetes, and hypertension; the mean CAVI value in the control group (6.9) was significantly lower compared to the patients with CAD (CAVI = 9.2; P < 0.001 vs. control group), diabetes (CAVI = 8.5; P < 0.001 vs. control group), and hypertension (CAVI = 8.9; P < 0.001 vs. control group). These results demonstrate that CAVI should be considered as an important clinical parameter independent of blood pressure changes, and should be recommended as a valuable indicator of the preventive evaluation of the arteriosclerotic risk in healthy subjects and patients with life-style related diseases.
- MeSH
- arteria brachialis fyziologie MeSH
- arteriae carotides fyziologie MeSH
- arterioskleróza diagnóza MeSH
- diabetes mellitus prevence a kontrola MeSH
- diagnostické techniky kardiovaskulární přístrojové vybavení trendy MeSH
- diagnostické vybavení trendy MeSH
- dospělí MeSH
- financování organizované MeSH
- hypertenze komplikace prevence a kontrola MeSH
- kardiovaskulární nemoci diagnóza MeSH
- kotník krevní zásobení MeSH
- krevní tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- měření krevního tlaku mortalita přístrojové vybavení trendy MeSH
- nemoci koronárních tepen diagnóza prevence a kontrola MeSH
- neparametrická statistika MeSH
- oscilometrie přístrojové vybavení využití MeSH
- pulzatilní průtok MeSH
- reprodukovatelnost výsledků MeSH
- rychlost toku krve fyziologie MeSH
- senioři MeSH
- studie případů a kontrol MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- MeSH
- ambulantní monitorování krevního tlaku metody přístrojové vybavení využití MeSH
- dítě MeSH
- domácí ošetřování metody využití MeSH
- dospělí MeSH
- emoce MeSH
- lidé MeSH
- manometrie metody přístrojové vybavení využití MeSH
- měření krevního tlaku metody přístrojové vybavení využití MeSH
- oscilometrie metody přístrojové vybavení využití MeSH
- ošetřovatelská péče metody normy využití MeSH
- stetoskopy využití MeSH
- těhotenství krev MeSH
- zátěžový test metody přístrojové vybavení využití MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- těhotenství krev MeSH
- ženské pohlaví MeSH
Měření krevního tlaku (kazuální krevní tlak) je jedním z nejčastěji prováděných výkonů v ordinaci lékaře. Závažnost hypertenze lépe odráží hodnoty TK měřené v domácím prostředí. Ještě přesnější informaci o profilu TK poskytuje 24hodinové ambulantní monitorování krevního tlaku (ABPM). Standardně měříme TK nepřímou auskultační metodou rtuťovým tonometrem na paži. Systolický krevní tlak odečítáme v 1. a diastolický TK v 5. Korotkovově fázi. V určitých specifických situacích, provázených zvýšeným minutovým výdejem, odečítáme diastolický TK ve fázi 4. (těhotné ženy, děti do 13 roků). Při měření musíme používat vždy správnou velikost manžety, odpovídající objemu paže vyšetřovaného. Pro domácí měření TK jsou vhodnější automatické oscilometrické přístroje. Pacienti by měli používat pouze validizované přístroje a měli by být informováni o správné technice měření.
The blood pressure measurement is one of the most frequently performed procedures in a physician office. It is described as a „causal blood pressure”. The severity of hypertension is better reflected by home blood pressure measurement. 24 hour blood pressure monitoring provides even more precise information about a blood pressure profile. Standard measurement of blood pressure by indirect auscultation method uses a mercury sphygmomanometer on arm. Systolic blood pressure is read in the 1st phase and diastolic in the 5th Korotkoff phase. In specific situations accompanied by increased cardiac output, the diastolic blood pressure is read in the 4th phase (pregnant women, children under 13 years). We should use an appropriate size of a blood pressure cuff reflecting the arm circumference of an examined person. Automated oscilometric devices are more suitable for home blood pressure measurement. Patients should use only validated devices and should be informed about correct blood pressure measurement.
Aims: The goal of this study was to investigate the eff ect of chronic smoking on arterial stiff ness at a peripheralsite using pulse wave analysis. Methods: Forty two non-smokers (17 males, 25 females) of average age 20.2 ± 1.3 year and forty fi ve smokers(19 males, 26 females) of average age 24.3 ± 2.4 year were included in the study. Four parameters, SI (stiff ness index),RI (refl ection index), CT (crest time) and IWD (interwave distance) were evaluated by means of an adapted devicebased on pletysmographic principles that transform volume changes to voltage changes. Results: SI corresponding to pulse wave velocity was 0.64 m/s higher in smokers than in non-smokers (7.25 ±0.53 m/s versus 7.89 ± 0.73 m/s, P < 0.001). RI was signifi cantly higher in smokers (42.49 ± 6.71 %, versus 35.46 ±0.06 %, P < 0.001) than in non-smokers. IWD for non-smokers was 8.01 ± 0.13 %, in smokers we found a 16 % increaseto 9.21 ± 0.83 % (P < 0.001). We detected a small increase in CT in smokers compared to non-smokers (0.09 ± 0.01 sversus 0.10 ± 0.01 s, P < 0.005). Conclusions: Chronic tobacco smoking is associated with endothelial dysfunction. In smokers we found increasedvalues for all assessed parameters. Our results suggest that the negative eff ect of cigarette smoking on the vascularsystem can be found even in young smokers who have been smoking for less than 10 years.
- MeSH
- arteria radialis MeSH
- endoteliální buňky patologie MeSH
- financování organizované MeSH
- kardiovaskulární nemoci diagnóza etiologie MeSH
- kouření škodlivé účinky MeSH
- lidé MeSH
- oscilometrie metody využití MeSH
- oxid dusnatý škodlivé účinky MeSH
- pletysmografie metody využití MeSH
- pulz statistika a číselné údaje MeSH
- statistika jako téma MeSH
- studie případů a kontrol MeSH
- ultrasonografie metody využití MeSH
- Check Tag
- lidé MeSH
- MeSH
- adherence pacienta MeSH
- centralizované nemocniční služby metody využití MeSH
- diagnostické techniky dýchacího ústrojí klasifikace přístrojové vybavení využití MeSH
- dítě MeSH
- lidé MeSH
- oscilometrie metody přístrojové vybavení využití MeSH
- plicní ventilace fyziologie MeSH
- spirometrie metody přístrojové vybavení trendy MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
Měření krevního tlaku (kazuální krevní tlak) je jedním z nejčastěji prováděných výkonů v ordinaci lékaře. Závažnost hypertenze lépe odráží hodnoty TK měřené v domácím prostředí. Ještě přesnější informaci o profilu TK poskytuje 24hodinové ambulantní monitorování krevního tlaku (ABPM). Standardně měříme TK nepřímou auskultační metodou rtuťovým tonometrem na paži. Systolický krevní tlak odečítáme v 1. a diastolický TK v 5. Korotkovově fázi. V určitých specifických situacích, provázených zvýšeným minutovým výdejem, odečítáme diastolický TK ve fázi 4. (těhotné ženy, děti do 13 roků). Při měření musíme používat vždy správnou velikost manžety, odpovídající objemu paže vyšetřovaného. Pro domácí měření TK jsou vhodnější automatické oscilometrické přístroje. Pacienti by měli používat pouze validizované přístroje a měli by být informováni o správné technice měření.
- MeSH
- experimenty na lidech MeSH
- financování organizované MeSH
- fotopletysmografie metody přístrojové vybavení využití MeSH
- lidé MeSH
- manometrie metody přístrojové vybavení využití MeSH
- měření krevního tlaku metody přístrojové vybavení využití MeSH
- oscilometrie metody využití MeSH
- počítačové zpracování signálu MeSH
- pulz MeSH
- statistika jako téma MeSH
- Check Tag
- lidé MeSH