BACKGROUND: The optimal method to identify the arrhythmogenic substrate of scar-related ventricular tachycardia (VT) is unknown. Sites of activation slowing during sinus rhythm (SR) often colocalize with the VT circuit. However, the utility and limitations of such approach for guiding ablation are unknown. METHODS: We conducted a multicenter study in patients with infarct-related VT. The left ventricular (LV) was mapped during activation from 3 directions: SR (or atrial pacing), right ventricular, and LV pacing at 600 ms. Ablation was applied selectively to the cumulative area of slow activation, defined as the sum of all regions with activation times of ≥40 ms per 10 mm. Hemodynamically tolerated VTs were mapped with activation or entrainment. The primary outcome was a composite of appropriate implanted cardioverter-defibrillator therapies and cardiovascular death. RESULTS: In 85 patients, the LV was mapped during activation from 2.4±0.6 directions. The direction of LV activation influenced the location and magnitude of activation slowing. The spatial overlap of activation slowing between SR and right ventricular pacing was 84.2±7.1%, between SR and LV pacing was 61.4±8.8%, and between right ventricular and LV pacing was 71.3±9.6% (P<0.05 between all comparisons). Mapping during SR identified only 66.2±8.2% of the entire area of activation slowing and 58% critical isthmus sites. Activation from other directions by right ventricular and LV stimulation unmasked an additional 33% of slowly conducting zones and 25% critical isthmus sites. The area of maximal activation slowing often corresponded to the site where the wavefront first interacted with the infarct. During a follow-up period of 3.6 years, the primary end point occurred in 14 out of 85 (16.5%) patients. CONCLUSIONS: The spatial distribution of activation slowing is dependent on the direction of LV activation with the area of maximal slowing corresponding to the site where the wavefront first interacts with the infarct. This data may have implications for VT substrate mapping strategies.
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- elektrofyziologické techniky kardiologické MeSH
- katetrizační ablace * škodlivé účinky mortalita MeSH
- komorová tachykardie diagnóza mortalita patofyziologie chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční frekvence MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Research Support, N.I.H., Extramural MeSH
- Geografické názvy
- Evropa MeSH
- Korejská republika MeSH
- Spojené státy americké MeSH
Aims: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an ion channelopathy characterized by ventricular arrhythmia during exertion or stress. Mutations in RYR2-coded Ryanodine Receptor-2 (RyR2) and CASQ2-coded Calsequestrin-2 (CASQ2) genes underlie CPVT1 and CPVT2, respectively. However, prognostic markers are scarce. We sought to better characterize the phenotypic and genotypic spectrum of CPVT, and utilize molecular modelling to help account for clinical phenotypes. Methods and results: This is a Pediatric and Congenital Electrophysiology Society multicentre, retrospective cohort study of CPVT patients diagnosed at <19 years of age and their first-degree relatives. Genetic testing was undertaken in 194 of 236 subjects (82%) during 3.5 (1.4-5.3) years of follow-up. The majority (60%) had RyR2-associated CPVT1. Variant locations were predicted based on a 3D structural model of RyR2. Specific residues appear to have key structural importance, supported by an association between cardiac arrest and mutations in the intersubunit interface of the N-terminus, and the S4-S5 linker and helices S5 and S6 of the RyR2 C-terminus. In approximately one quarter of symptomatic patients, cardiac events were precipitated by only normal wakeful activities. Conclusion: This large, multicentre study identifies contemporary challenges related to the diagnosis and prognostication of CPVT patients. Structural modelling of RyR2 can improve our understanding severe CPVT phenotypes. Wakeful rest, rather than exertion, often precipitated life-threatening cardiac events.
- MeSH
- dědičnost MeSH
- dítě MeSH
- fenotyp MeSH
- genetická predispozice k nemoci MeSH
- genetické markery MeSH
- kalsekvestrin genetika MeSH
- komorová tachykardie diagnóza genetika mortalita patofyziologie MeSH
- konformace proteinů MeSH
- lidé MeSH
- mladiství MeSH
- molekulární modely MeSH
- mutace * MeSH
- mutační analýza DNA MeSH
- náhlá srdeční smrt epidemiologie MeSH
- prognóza MeSH
- registrace MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- rodokmen MeSH
- ryanodinový receptor vápníkového kanálu chemie genetika metabolismus MeSH
- vztahy mezi strukturou a aktivitou MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
BACKGROUND: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP) patients with left ventricular dysfunction. OBJECTIVE: The analyses in the present study were designed to compare clinical outcomes for PP patients with and without a reduced ejection fraction (EF) and secondary prevention (SP) patients implanted with the S-ICD. METHODS: All patients 18 years and older from the S-ICD IDE study and the EFFORTLESS Registry with available data as of November 18, 2013, were included (n = 856; mean follow-up duration 644 days). Outcomes were evaluated in 2 analyses: (1) comparing all PP patients (n = 603, 70.4%) with all SP patients (n = 253, 29.6%) and (2) comparing all PP patients with an EF ≤35% (n = 379) with those with an EF >35% (n = 149, 17.4%). RESULTS: No differences were observed in mortality, complications, inappropriate therapy, or ability to convert ventricular tachyarrhythmias between SP and PP patients. However, SP patients had a higher incidence of appropriate therapy than did PP patients (11.9% vs 5.0%; P = .0004). In the PP subanalysis, the cohort with an EF ≤35% had significantly older patients with more comorbidities and higher mortality (3.0% annually vs 0.0%). Despite these differences, device-related complications, conversion efficacy, and incidence of inappropriate shock therapies were not significantly different between PP subgroups. CONCLUSION: The S-ICD performs well in protecting patients with either PP or SP implant indications from sudden cardiac death. Within PP patients, device performance was independent of EF.
- MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory * diagnóza patofyziologie MeSH
- elektrická defibrilace * škodlivé účinky přístrojové vybavení metody MeSH
- Kaplanův-Meierův odhad MeSH
- komorová tachykardie * mortalita terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- primární prevence metody statistika a číselné údaje MeSH
- protetické vybavení MeSH
- registrace MeSH
- sekundární prevence metody statistika a číselné údaje MeSH
- senioři MeSH
- tepový objem MeSH
- výsledky a postupy - zhodnocení (zdravotní péče) MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: The implantable cardioverter-defibrillator (ICD) is the standard therapy to prevent sudden cardiac death in patients with coronary artery disease and unstable ventricular tachyarrhythmias. The prospective multinational SMS (Substrate Modification Study) was designed to assess whether prophylactic ablation of the arrhythmogenic substrate reduces or prevents the recurrence of ventricular tachycardia/ventricular fibrillation in such patients. METHODS AND RESULTS: Of 111 patients included in an intention-to-treat analysis, 54 were randomly assigned catheter ablation plus ICD implantation (ablation group: 68±8 years; 47 men), whereas 57 were assigned ICD implantation without catheter ablation (ICD-only group: 66±8 years; 46 men). Primary study end point was the time to first recurrence of ventricular tachycardia/ventricular fibrillation. ICD episodes were assessed and verified by an independent board. Patients were followed up for 2.3±1.1 years. The primary end point was reached by 25 ablation patients and 26 ICD-only patients. Two-year event-free survival was estimated at 49.0% (95% confidence interval, 33.3%-62.9%) in the former and 52.4% (36.7%-65.9%) in the latter groups. Comparison of episode incidence revealed no significant difference in the primary end point (P=0.84). In an Andersen-Gill regression model with multiple end point recurrences, the difference between the study arms significantly favored catheter ablation for both the primary end point and all but one of the predefined subgroups of detected arrhythmia events. CONCLUSIONS: SMS failed to meet the primary end point of time to first ventricular tachycardia/ventricular fibrillation recurrence. However, catheter ablation did reduce the total number of ICD interventions during the duration of follow-up. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov. Unique identifier: NCT00170287.
- MeSH
- analýza přežití MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- fibrilace komor diagnóza mortalita chirurgie MeSH
- hodnocení rizik MeSH
- Kaplanův-Meierův odhad MeSH
- katetrizační ablace metody mortalita MeSH
- komorová tachykardie diagnóza mortalita chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mapování potenciálů tělesného povrchu MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- nemoci koronárních tepen diagnóza mortalita chirurgie MeSH
- neparametrická statistika MeSH
- prognóza MeSH
- proporcionální rizikové modely MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
OBJECTIVES: To describe the incidence, onset, predictors and outcome of ventricular tachyarrhythmia (VTA) in pregnant women with heart disease. BACKGROUND: VTA during pregnancy will cause maternal morbidity and even mortality and will have impact on fetal outcome. Insufficient data exist on the incidence and outcome of VTA in pregnancy. METHODS AND RESULTS: From January 2007 up to October 2013, 99 hospitals in 39 countries enrolled 2966 pregnancies in women with structural heart disease. Forty-two women (1.4%) developed clinically relevant VTA during pregnancy, which occurred mainly in the third trimester (48%). NYHA class >1 before pregnancy was an independent predictor for VTA. Heart failure during pregnancy was more common in women with VTA than in women without VTA (24% vs. 12%, p=0.03) and maternal mortality was respectively 2.4% and 0.3% (p=0.15). More women with VTA delivered by Cesarean section than women without VTA (68% vs. 47%, p=0.01). Neonatal death, preterm birth (<37weeks), low birthweight (<2500g) and Apgar score <7 occurred more often in women with VTA (4.8% vs. 0.3%, p=0.01; 36% vs. 16%, p=0.001; 33% vs. 15%, p=0.001 and 25% vs. 7.3%, p=0.001, respectively). CONCLUSIONS: VTA occurred in 1.4% of pregnant women with cardiovascular disease, mainly in the third trimester, and was associated with heart failure during pregnancy. NYHA class before pregnancy was predictive. VTA during pregnancy had clear impact on fetal outcome.
- MeSH
- císařský řez statistika a číselné údaje MeSH
- dospělí MeSH
- hodnocení rizik MeSH
- kardiovaskulární komplikace v těhotenství * diagnóza mortalita MeSH
- komorová tachykardie * diagnóza etiologie mortalita MeSH
- lidé MeSH
- mezinárodní spolupráce MeSH
- novorozenec MeSH
- předčasný porod epidemiologie etiologie MeSH
- registrace statistika a číselné údaje MeSH
- rizikové faktory MeSH
- srdeční selhání * komplikace diagnóza epidemiologie MeSH
- stupeň závažnosti nemoci MeSH
- těhotenství MeSH
- třetí trimestr těhotenství MeSH
- výsledek těhotenství epidemiologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- novorozenec MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa epidemiologie MeSH
BACKGROUND: Pacing in the right ventricle can cause a variety of detrimental effects, including atrial tachyarrhythmias (atrial tachycardia [AT]/atrial fibrillation [AF]). OBJECTIVE: The purpose of this study was to evaluate the incidence and predictors of persistent AT/AF in patients with long-term exposure to ventricular pacing. METHODS: In a multicenter international trial, 605 patients (age 75 ± 11 years, 240 women) referred for replacement of an implanted pacemaker or implantable cardioverter-defibrillator (ICD), with a history of high-percentage (>40%) ventricular pacing, were randomly allocated to standard dual-chamber pacing or managed ventricular pacing (MVP), a pacing modality that minimizes ventricular pacing. The main end-point of this secondary analysis of the PreFER MVP randomized study was persistent AT/AF, defined as ≥7 consecutive days with AT/AF or AT/AF interrupted by atrial cardioversion or AT/AF present during 2 consecutive follow-up visits. RESULTS: Persistent AT/AF was observed in 71 patients (11.7%) after 2 years of follow-up. At multivariable Cox regression analysis, prior AT/AF (hazard ratio [HR] 2.85, 95% confidence interval [CI] 1.20-6.22, P = .017) and ventricular pacing percentage, estimated in the first 3 months, ≥10% (HR 3.24, 95% 95% CI 1.13-9.31, P = .029) were independent predictors for persistent AT/AF. MVP was associated with persistent AT/AF risk (HR 3.41, 95% 95% CI 1.10-10.6, P = .024) in the subgroup of patients with baseline long PR interval (PR >230 ms) but not in the whole population. CONCLUSION: In pacemaker and ICD replacement patients, a high percentage of ventricular pacing is associated with higher risk of persistent AT/AF. Use of algorithms that minimize right ventricular pacing may benefit patients with normal spontaneous AV conduction but should be evaluated with caution in patients with long PR interval.
- MeSH
- defibrilátory implantabilní škodlivé účinky MeSH
- elektivní chirurgické výkony metody MeSH
- elektrokardiografie metody MeSH
- fibrilace síní diagnóza mortalita terapie MeSH
- hodnocení rizik MeSH
- interval spolehlivosti MeSH
- jednoduchá slepá metoda MeSH
- Kaplanův-Meierův odhad MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- komorová tachykardie diagnóza mortalita terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- míra přežití MeSH
- multivariační analýza MeSH
- odstranění implantátu metody MeSH
- opakovaná terapie MeSH
- prognóza MeSH
- proporcionální rizikové modely MeSH
- prospektivní studie MeSH
- reoperace metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sexuální faktory MeSH
- stupeň závažnosti nemoci MeSH
- věkové faktory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: Left ventricular assist devices (LVADs) are increasingly used as a bridge to cardiac transplantation or as destination therapy. Patients with LVADs are at high risk for ventricular arrhythmias. This study describes ventricular arrhythmia characteristics and ablation in patients implanted with a Heart Mate II device. METHODS AND RESULTS: All patients with a Heart Mate II device who underwent ventricular arrhythmia catheter ablation at 9 tertiary centers were included. Thirty-four patients (30 male, age 58±10 years) underwent 39 ablation procedures. The underlying cardiomyopathy pathogenesis was ischemic in 21 and nonischemic in 13 patients with a mean left ventricular ejection fraction of 17%±5% before LVAD implantation. One hundred and ten ventricular tachycardias (VTs; cycle lengths, 230-740 ms, arrhythmic storm n=28) and 2 ventricular fibrillation triggers were targeted (25 transseptal, 14 retrograde aortic approaches). Nine patients required VT ablation <1 month after LVAD implantation because of intractable VT. Only 10/110 (9%) of the targeted VTs were related to the Heart Mate II cannula. During follow-up, 7 patients were transplanted and 10 died. Of the remaining 17 patients, 13 were arrhythmia-free at 25±15 months. In 1 patient with VT recurrence, change of turbine speed from 9400 to 9000 rpm extinguished VT. CONCLUSIONS: Catheter ablation of VT among LVAD recipients is feasible and reasonably safe even soon after LVAD implantation. Intrinsic myocardial scar, rather than the apical cannula, seems to be the dominant substrate.
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- centra terciární péče MeSH
- elektrofyziologické techniky kardiologické MeSH
- funkce levé komory srdeční * MeSH
- katetrizační ablace * MeSH
- komorová tachykardie diagnóza mortalita patofyziologie chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- recidiva MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční selhání diagnóza mortalita patofyziologie terapie MeSH
- studie proveditelnosti MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Geografické názvy
- Evropa MeSH
- Spojené státy americké MeSH
INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P < 0.001 for all comparisons). Occurrence of total inappropriate and appropriate ICD therapies was significantly reduced by high-rate cut-off ICD programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. CONCLUSION: High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy.
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- design vybavení MeSH
- elektrická defibrilace škodlivé účinky přístrojové vybavení mortalita MeSH
- elektrofyziologické techniky kardiologické MeSH
- ischemická choroba srdeční komplikace diagnóza mortalita MeSH
- Kaplanův-Meierův odhad MeSH
- kardiomyopatie diagnóza etiologie mortalita patofyziologie MeSH
- komorová tachykardie diagnóza etiologie mortalita patofyziologie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- náhlá srdeční smrt etiologie prevence a kontrola MeSH
- počítačové zpracování signálu MeSH
- prediktivní hodnota testů MeSH
- proporcionální rizikové modely MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- selhání zařízení * MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Evropa MeSH
- Izrael MeSH
- Spojené státy americké MeSH
BACKGROUND: The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focus on ICD therapy and programming in the MADIT-RIT population. METHODS AND RESULTS: In MADIT-RIT, 1500 patients with a primary prophylactic indication for ICD or cardiac resynchronization therapy with defibrillator were randomized to 1 of 3 different ICD programming arms: conventional programming (ventricular tachycardia zone ≥170 beats per minute), high-rate programming (ventricular tachycardia zone ≥200 beats per minute), and delayed programming (60-second delay before therapy ≥170 beats per minute). Multivariate Cox models were used to assess the influence of time-dependent appropriate and inappropriate ICD therapy (shock and antitachycardia pacing) and randomized programming arm on all-cause mortality. During an average follow-up of 1.4±0.6 years, 71 of 1500 (5%) patients died: cardiac in 40 patients (56.3%), noncardiac in 23 patients (32.4%), and unknown in 8 patients (11.3%). Appropriate shocks (hazard ratio, 6.32; 95% confidence interval, 3.13-12.75; P<0.001) and inappropriate therapy (hazard ratio, 2.61; 95% confidence interval, 1.28-5.31; P=0.01) were significantly associated with an increased mortality risk. There was no evidence of increased mortality risk in patients who experienced appropriate antitachycardia pacing only (hazard ratio, 1.02; 95% confidence interval, 0.36-2.88; P=0.98). Randomization to conventional programming was identified as an independent predictor of death when compared with patients randomized to high-rate programming (hazard ratio, 2.0; 95% confidence interval, 1.06-3.71; P=0.03). CONCLUSIONS: In MADIT-RIT, appropriate shocks, inappropriate ICD therapy, and randomization to conventional ICD programming were independently associated with an increased mortality risk. Appropriate antitachycardia pacing was not related to an adverse outcome. CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov Unique identifier: NCT00947310.
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- elektrická defibrilace škodlivé účinky přístrojové vybavení mortalita MeSH
- Kaplanův-Meierův odhad MeSH
- komorová tachykardie diagnóza mortalita patofyziologie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- proporcionální rizikové modely MeSH
- protézy - design * MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- selhání protézy * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční frekvence MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Evropa MeSH
- Izrael MeSH
- Japonsko MeSH
- Kanada MeSH
- Spojené státy americké MeSH
BACKGROUND: Catheter ablation has become an established treatment modality for a broad spectrum of ventricular tachycardias (VTs). We analyzed incidence and predictors of major complications of VT ablation procedures in a high-volume expert center. METHODS AND RESULTS: We evaluated 548 consecutive patients who underwent 722 ablation procedures, 473 (65.5%) for structural heart disease VT in the period 2006 to 2012. There were 45 (6.2%) major complications observed in 44 patients. Access site vascular complications were the most frequent (3.6%). Three patients (0.4%) had cardiac tamponade/hemopericardium, and 5 patients (0.7%) had a thromboembolic event. No procedural deaths occurred. Procedures for structural heart disease VT versus idiopathic VT had a significantly higher complication rate (8.0% versus 2.8%; P=0.006). Similarly, patients with electrical storm (10.1% versus 5.3%; P=0.04) and nonelective procedures (8.4% versus 3.5%; P=0.007) were at higher risk of complications. On multivariate analysis, age >70 years (P=0.01), serum creatinine >115 μmol/L (P=0.0003), and individual operator (P=0.0001) were the only independent predictors of complications. Overall 30-day mortality in the structural heart disease VT group reached 5.0% (patients) and 3.6% (procedures). Death was associated with early recurrence of VT/ventricular fibrillation (P=0.003) and ablation for electrical storm (P=0.02). CONCLUSIONS: Complication rates for VT ablation are significantly lower in idiopathic VT or in elective procedures. Independent predictors of complications include age, renal insufficiency, and individual operator. Postprocedural mortality is predicted by early recurrence of VT/ventricular fibrillation and ablation for electrical storm.
- MeSH
- časové faktory MeSH
- dospělí MeSH
- hodnocení rizik MeSH
- incidence MeSH
- katetrizační ablace škodlivé účinky mortalita MeSH
- klinické kompetence MeSH
- komorová tachykardie diagnóza mortalita chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- pooperační komplikace diagnóza epidemiologie mortalita terapie MeSH
- renální insuficience epidemiologie MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- senioři MeSH
- specializovaná centra se zvyšujícím se počtem výkonů a tím zvyšující se kvalitou léčby MeSH
- věkové faktory MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH