Flow-based analytical systems Dotaz Zobrazit nápovědu
A fully automated spectrophotometric method based on flow-batch analysis has been developed for the determination of clenbuterol including an on-line solid phase extraction using a molecularly imprinted polymer (MIP) as the sorbent. The molecularly imprinted solid phase extraction (MISPE) procedure allowed analyte extraction from complex matrices at low concentration levels and with high selectivity towards the analyte. The MISPE procedure was performed using a commercial MIP cartridge that was introduced into a guard column holder and integrated in the analyzer system. Optimized parameters included the volume of the sample, the type and volume of the conditioning and washing solutions, and the type and volume of the eluent. Quantification of clenbuterol was carried out by spectrophotometry after in-system post-elution analyte derivatization based on azo-coupling using N- (1-Naphthyl) ethylenediamine as the coupling agent to yield a red-colored compound with maximum absorbance at 500nm. Both the chromogenic reaction and spectrophotometric detection were performed in a lab-made flow-batch mixing chamber that replaced the cuvette holder of the spectrophotometer. The calibration curve was linear in the 0.075-0.500mgL-1 range with a correlation coefficient of 0.998. The precision of the proposed method was evaluated in terms of the relative standard deviation obtaining 1.1% and 3.0% for intra-day precision and inter-day precision, respectively. The detection limit was 0.021mgL-1 and the sample throughput for the entire process was 3.4h-1. The proposed method was applied for the determination of CLB in human urine and milk substitute samples obtaining recoveries values within a range of 94.0-100.0%.
- MeSH
- analýza moči metody MeSH
- barva MeSH
- klenbuterol analýza izolace a purifikace moč MeSH
- kolorimetrie MeSH
- lidé MeSH
- limita detekce MeSH
- metody pro přípravu analytických vzorků MeSH
- molekulový imprinting * MeSH
- náhražky mléka chemie MeSH
- polymery klasifikace MeSH
- rozpouštědla chemie MeSH
- teplota MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
An automatic flow-based system as a front end to liquid chromatography (LC) for on-line dynamic leaching of microplastic materials (polyethylene of medium density and poly(vinyl chloride)) with incurred phthalates and bisphenol A is herein presented. The microplastic particles were packed in a metal column holder, through which seawater was pumped continuously by resorting to advanced flow methodology. Each milliliter of the leachable (bioaccessible) fraction of chemical additives was preconcentrated on-line using a 10 mm-long octadecyl monolithic silica column placed in the sampling loop of the injection valve of a HPLC system that served concomitantly for analyte uptake and removal of the seawater matrix. After loading of the leachate fraction, the LC valve was switched to the inject position and the analytes were eluted and separated by a monolithic column (Onyx C18HD 100 × 4.6 mm) using an optimized acetonitrile/water gradient with UV detection at 240 nm. The automatic flow method including dynamic flow-through extraction, on-line sorptive preconcentration, and matrix clean-up was synchronized with the HPLC separation, which lasted ca. 9 min. The only two currently available multi-component certified reference materials (CRM) of microplastics (CRM-PE002 and CRM-PVC001) were used for method development and validation. Out of the eight regulated phthalates contained in the two CRMs, only the 2 most polar species, namely, dimethyl phthalate and diethyl phthalate as well as bisphenol A, were leached significantly by the seawater in less than 2 h, with bioaccessibility percentages of 51-100%. The leaching profiles were monitored and modeled with a first-order kinetic equation so as to determine the rate constants for desorption in a risk assessment scenario. Intermediate precision values of bioaccessibility data for three batches of CRMs were for the suite of targeted compounds ≤22%. This work for the first time reports a fully automatic flow method with infinite sink capacity (i.e., using a surplus of extracting solution) for the target species able to mimic the leaching of additives from plastic debris across the water body in marine settings under worst-case extraction conditions.
Para Red (PR) and Sudan dyes have been illegally used as colorants to adulterate certain foods by enhancing their red/orange colour. In addition, they are toxic and carcinogenic. This work presents the development of a simple flow injection chromatographic method combined with chemometric tools to perform the determination of PR, Sudan I (SI) and Sudan II (SII) in food samples. The flow chromatographic system consisted of a low-pressure manifold coupled to a reverse phase monolithic column. A Partial Least Square (PLS) model was applied to resolve overlapped absorption spectra registered for each dye at the corresponding retention time. The relative errors of calibration (RMSECV, %) were 0.49, 0.85 and 0.23, and the relative errors of prediction (RMSEP, %) were 1.12, 0.75 and 0.33 for PR, SI and SII, respectively. The residual predictive deviation (RPD) values obtained were higher than 3.00 for all analytes. The method was successfully applied to quantify the dyes in six different commercial spices samples. The results were compared with the HPLC reference method concluding that there were no significant differences at the studied confidence level (α = 0.05). The proposed method can be used to rapidly determine the analytes in a simple, reliable, low-cost and environmentally-friendly manner.Supplementary Information: The online version contains supplementary material available at 10.1007/s13197-021-05299-8.
- Publikační typ
- časopisecké články MeSH
Short-chain fatty acids (SCFAs) are the main metabolites produced by bacterial fermentation of non-digestible carbohydrates in the gastrointestinal tract. They can be seen as the major flow of carbon from the diet, through the microbiome to the host. SCFAs have been reported as important molecules responsible for the regulation of intestinal homeostasis. Moreover, these molecules have a significant impact on the immune system and are able to affect inflammation, cardiovascular diseases, diabetes type II, or oncological diseases. For this purpose, SCFAs could be used as putative biomarkers of various diseases, including cancer. A potential diagnostic value may be offered by analyzing SCFAs with the use of advanced analytical approaches such as gas chromatography (GC), liquid chromatography (LC), or capillary electrophoresis (CE) coupled with mass spectrometry (MS). The presented review summarizes the importance of analyzing SCFAs from clinical and analytical perspective. Current advances in the analysis of SCFAs focused on sample pretreatment, separation strategy, and detection methods are highlighted. Additionally, it also shows potential areas for the development of future diagnostic tools in oncology and other varieties of diseases based on targeted metabolite profiling.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
About eight years ago, a new automation approach and flow technique called "Lab-In-Syringe" was proposed. It was derived from previous flow techniques, all based on handling reagent and sample solutions in a flow manifold. To date Lab-In-Syringe has evidently gained the interest of researchers in many countries, with new modifications, operation modes, and technical improvements still popping up. It has proven to be a versatile tool for the automation of sample preparation, particularly, liquid-phase microextraction approaches. This article aims to assist newcomers to this technique in system planning and setup by overviewing the different options for configurations, limitations, and feasible operations. This includes syringe orientation, in-syringe stirring modes, in-syringe detection, additional inlets, and addable features. The authors give also a chronological overview of technical milestones and a critical explanation on the potentials and shortcomings of this technique, calculations of characteristics, and tips and tricks on method development. Moreover, a comprehensive overview of the different operation modes of Lab-In-Syringe automated sample pretreatment is given focusing on the technical aspects and challenges of the related operations. We further deal with possibilities on how to fabricate required or useful system components, in particular by 3D printing technology, with over 20 different elements exemplarily shown. Finally, a short discussion on shortcomings and required improvements is given.
Affinity-based biosensing systems have become an important analytical tool for the detection and study of numerous biomolecules. The merging of these sensing technologies with microfluidic flow cells allows for faster detection times, increased sensitivities, and lower required sample volumes. In order to obtain a higher degree of performance from the sensor, it is important to know the effects of the flow cell geometry on the sensor sensitivity. In these sensors, the sensor sensitivity is related to the overall diffusive flux of analyte to the sensing surface; therefore increases in the analyte flux will be manifested as an increase in sensitivity, resulting in a lower limit of detection (LOD). Here we present a study pertaining to the effects of the flow cell height H on the analyte flux J, where for a common biosensor design we predict that the analyte flux will scale as J ≈ H(-2/3). We verify this scaling behavior via both numerical simulations as well as an experimental surface plasmon resonance (SPR) biosensor. We show the reduction of the flow cell height can have drastic effects on the sensor performance, where the LOD of our experimental system concerning the detection of ssDNA decreases by a factor of 4 when H is reduced from 47 μm to 7 μm. We utilize these results to discuss the applicability of this scaling behavior with respect to a generalized affinity-based biosensor.
Data Base and Knowledge-Based Systems Integration -- Computerized Knowledge Bases in Primary Health Care Based Systems -- H. Medical Case Based Reasoning Systems -- S. Brantigan 1116 -- Computer-based Diagnostic Support Systems in Histopathology: What Should They Do? Schuurman: REGIONAL HEALTH CARE NETWORKS BASED 1344 -- ON LOCAL ATTACHED MINI-COMPUTER SYSTEMS.
IFIP world conference series on medical informatics Studies in health technology and informatics
sv. ; 27 cm
- MeSH
- informační systémy MeSH
- lékařská informatika MeSH
- lékařství MeSH
- Publikační typ
- kongresy MeSH
- sborníky MeSH
- Konspekt
- Lékařské vědy. Lékařství
- NLK Obory
- lékařská informatika
Based Sensors Design 5 -- 1.1.4 Composite Polymers Based Sensors Design 8 -- 1.1.5 Sol-Gel Based Sensors Sol-Gel Based Biosensors 125 -- 6.56.7 Carbon Paste Based Biosensors 127 -- 6.56.8 Graphite Rod Based SYSTEMS WITH ELECTROCHEMICAL SENSORS -- AS DETECTORS 241 -- 13.1 Flow Injection Analysis (FIA) 241 - Systems 242 -- 13.4 Coated Tubular Electrodes in Flow Systems 247 -- 13.4.1 Applications of Coated Tubular Electrodes in Flow Systems 248 -- 13.5 Applications of Electrochemical Sensor/FIA Systems in -- Bioanalysis
288 s.
- Konspekt
- Biotechnologie. Genetické inženýrství
- NLK Obory
- biomedicínské inženýrství
This article aims to provide an overview on the transition from earlier laboratory automation using analytical flow approaches toward today's applications of flow methodologies, recent developments, and future trends. The article is directed to flow practitioners while serving as a valuable reference to newcomers in the field in providing insight into flow techniques and conceptual differences in operation across the distinct flow generations. In the focus are the recently developed and complementary techniques Lab-On-Valve and Lab-In-Syringe. In the following, a brief comparison of the different application niches and contributions of flow techniques to past and modern analytical chemistry is given, including (i) the development of sample pretreatment approaches, (ii) the potential applicability for in-situ/on-site monitoring of environmental compartments or technical processes, (iii) the ability of miniaturization of laboratory chemistry, (iv) the unique advantages for implementation of kinetic assays, and finally (v) the beneficial online coupling with scanning or separation analytical techniques. We also give a critical comparison to alternative approaches for automation based on autosamplers and robotic systems. Finally, an outlook on future applications and developments including 3D prototyping and specific needs for further improvements is given. Graphical abstract ᅟ.
- Publikační typ
- časopisecké články MeSH
In the rapidly evolving field of primary immunodeficiencies (PID), the EuroFlow consortium decided to develop a PID orientation and screening tube that facilitates fast, standardized, and validated immunophenotypic diagnosis of lymphoid PID, and allows full exchange of data between centers. Our aim was to develop a tool that would be universal for all lymphoid PIDs and offer high sensitivity to identify a lymphoid PID (without a need for specificity to diagnose particular PID) and to guide and prioritize further diagnostic modalities and clinical management. The tube composition has been defined in a stepwise manner through several cycles of design-testing-evaluation-redesign in a multicenter setting. Equally important appeared to be the standardized pre-analytical procedures (sample preparation and instrument setup), analytical procedures (immunostaining and data acquisition), the software analysis (a multidimensional view based on a reference database in Infinicyt software), and data interpretation. This standardized EuroFlow concept has been tested on 250 healthy controls and 99 PID patients with defined genetic defects. In addition, an application of new EuroFlow software tools with multidimensional pattern recognition was designed with inclusion of maturation pathways in multidimensional patterns (APS plots). The major advantage of the EuroFlow approach is that data can be fully exchanged between different laboratories in any country of the world, which is especially of interest for the PID field, with generally low numbers of cases per center.
- MeSH
- dítě MeSH
- dospělí MeSH
- imunitní systém patologie MeSH
- imunofenotypizace metody MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- předškolní dítě MeSH
- primární imunodeficience diagnóza MeSH
- průtoková cytometrie metody MeSH
- referenční standardy MeSH
- senioři MeSH
- studie případů a kontrol MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH