FPGA
Dotaz
Zobrazit nápovědu
This work describes the temperature measuring methods for patients and environment. Th e body temperature is measured by the resistance thermistor. Its analog output has to be suitably processed. Th e signal is modifi ed and digitalized. Th e signal is evaluated in the FPGA and used for the patient's diagnosis. For the temperature measuring of the environment is used a digital thermometer, which communicates with the FPGA.
- MeSH
- ambulantní monitorování metody přístrojové vybavení využití MeSH
- lidé MeSH
- počítačové zpracování signálu přístrojové vybavení MeSH
- služby domácí péče trendy využití MeSH
- telemedicína metody přístrojové vybavení trendy MeSH
- telemetrie metody přístrojové vybavení trendy MeSH
- tělesná teplota fyziologie MeSH
- teploměry využití MeSH
- teplota MeSH
- Check Tag
- lidé MeSH
... charakteristika 74 -- 4.2 Programovatelné součástky PLA a CPLD 76 -- 4.3 Programovatelné součástky FPGA ... ... 77 -- 4.3.1 Struktura obvodů FPGA 77 -- 4.3.2 Konfigurace obvodů FPGA 79 -- 4.3.3 Xilinx XC6200 (Algotronix ... ... CAL1024) 80 -- 4.3.4 Rodina obvodů Xilinx Virtex 81 -- 4.4 Návrh číslicových obvodů v FPGA 85 -- 4.4.1 ... ... 4.4.3 Použití dynamické rekonfigurace 88 -- 4.5 Případová studie: Implementace obrazového filtru v FPGA ... ... 191 -- 9.1 Možnosti využití FPGA 191 -- 9.1.1 FPGA pouze pro evaluaci kandidátních řešení 191 -- 9.1.2 ...
Gerstner ; sv. 4
Vyd. 1. 321 s. : il., tab. ; 24 cm
Nástup průmyslové revoluce umožnil, aby stroje za člověka převzaly značnou část fyzicky namáhavé práce. S rozvojem počítačů začínají stroje přebírat i intelektuálně náročnější činnosti. V tomto procesu hraje významnou roli umělá inteligence. Jednou z jejich nejdynamičtěji rozvíjejících se oblastí jsou evoluční algoritmy, které se inspirují biologickým fenoménem evoluce.
- MeSH
- algoritmy MeSH
- matematické pojmy MeSH
- počítačové metodologie MeSH
- Publikační typ
- monografie MeSH
- Konspekt
- Umělá inteligence
- NLK Obory
- knihovnictví, informační věda a muzeologie
We designed a simple, portable, low-cost and low-weight nondispersive infrared (NDIR) spectroscopy-based system for continuous remote sensing of atmospheric methane (CH4) with rapidly pulsed near-infrared light emitting diodes (NIR LED) at 1.65 μm. The use of a microcontroller with a field programmable gate array (μC-FPGA) enables on-the-fly and wireless streaming and processing of large data streams (~2 Gbit/s). The investigated NIR LED detection system offers favourable limits of detection (LOD) of 300 ppm (±5%) CH4,. All the generated raw data were processed automatically on-the-fly in the μC-FPGA and transferred wirelessly via a network connection. The sensing device was deployed for the portable sensing of atmospheric CH4 at a local landfill, resulting in quantified concentrations within the sampling area (ca 400 m2) in the range of 0.5%-3.35% CH4. This NIR LED-based sensor system offers a simple low-cost solution for continuous real-time, quantitative, and direct measurement of CH4 concentrations in indoor and outdoor environments, yet with the flexibility provided by the custom programmable software. It possesses future potential for remote monitoring of gases directly from mobile platforms such as smartphones and unmanned aerial vehicles (UAV).
- Publikační typ
- časopisecké články MeSH
... Cajal a Barricelliho vesmíry 126 -- Dvě vlastnosti čipu FPGA 127 -- První podobnost 127 -- Druhá podobnost ...
224 s. ; 20 cm
Společným rysem tématicky různorodých textů (např. homo erectus, lidský mozek, genetika, sexuální život) je snaha přiblížit problematiku přírodních věd prostřednictvím literárních metod. Vzájemným propojením vědeckého výzkumu s humanitními obory vznikne tzv. třetí kultura.
- MeSH
- biologická evoluce MeSH
- inteligence MeSH
- kulturní evoluce MeSH
- Publikační typ
- populární práce MeSH
- Konspekt
- Filozofie
- NLK Obory
- věda a výzkum
- zdravotní výchova
DNA glykosylasy jsou důležité enzymy sloužící k rozpoznání a odstranění poškození DNA, vzniklého samovolně nebo působením environmentálních činidel. Do Fpg/Nei rodiny patří proteiny schopny rozpoznávat a přispět k opravě oxidované báze, abazického místa nebo kovalentního příčného spojení řetězců DNA pomocí zatím neobjasněné opravné dráhy. Bez opravy tohoto poškození nemůže docházet k replikaci a může vést k mutacím a rakovině. Tato práce se snaží přispět k objasnění molekulárních mechanismů interakce NEIL3 (Endonukleasa VIII – like 3) z rodiny proteinů Fpg/Nei se substrátem – kovalentní spojení opačných řetězců DNA.
DNA glycosylases are important enzymes responsible for the recognition and removal of base DNA damage. These DNA lesions are formed spontaneously or as an effect of environmental agents. NEIL3 (Endonuklease VIII – like 3) enzyme belongs to a Fpg/Nei family of glycosylases implicated in the DNA repair of oxidative bases, abasic sites. Recently, it has been shown that these enzymes are capable of removal of one type of interstrand crosslink by so unknown repair pathway. Unrepaired DNA crosslinks block DNA replication and may lead to cell death or sever chromosomal damage and later even cancer. This thesis is focused on revealing molecular mechanisms of the interstrand DNA -DNA cross -link repair by NEIL3 glycosylase.
... Cytogenetická analýza lidských periferních lymfocyt ů FPG technika, Výměny sesterských chromatid - SCE ...
Acta hygienica, epidemiologica et microbiologica, ISSN 0862-5956 č. 3/2003
180 s., [9] s. obr. příl. : il. ; 21 cm
- MeSH
- látky znečišťující životní prostředí analýza MeSH
- monitorování životního prostředí MeSH
- testy genotoxicity MeSH
- Publikační typ
- směrnice MeSH
- Konspekt
- Životní prostředí a jeho ochrana
- NLK Obory
- environmentální vědy
Cílem studie bylo zhodnotit klinickou účinnost inzulinu glargin 300 U/ml (Gla-300) v léčbě pacientů s diabetem 2. typu (DM2) nedostatečně kompenzovaných bazálním inzulinem v podmínkách běžné klinické praxe v České republice (studie TOPAZ). TOPAZ byla prospektivní multicentrická neintervenční studie trvající 6 měsíců. Z 312 pacientů zapojených do studie bylo po 6 měsících hodnoceno 289. Primárním sledovaným parametrem byla změna HbA1c po 6 měsících. Jako sekundární cíle byly hodnoceny podíl pacientů s HbA1c < 7 % (< 53 mmol/mol), podíl pacientů s poklesem HbA1c nejméně o 0,5 % po 6 měsících, změna glykemie nalačno (FPG), tělesná hmotnost a dávka inzulinu po 3 a 6 měsících. Vyhodnocen byl také výskyt hypoglykemií, nežádoucích událostí a spokojenost pacientů s léčbou. HbA1c významně poklesl po 6 měsících (průměrná změna 0,9 ± 1,1 % [–9,9 ± 11,6 mmol/mol]; p < 0,0001). Cílový HbA1c < 7 % byl dosažen u 17,6 % pacientů, 66 % pacientů vykazovalo průměrný pokles HbA1c o 0,5 ± 0,8 %. Po 6 měsících klesla FPG (průměrná změna od počátku –1,8 ± 3,1 mmol/l), stejně jako výskyt hypoglykemií o 49 % (p < 0,0001), a to bez nárůstu tělesné hmotnosti. Nebyly pozorovány žádné významné bezpečnostní signály. V podmínkách běžné klinické praxe byla změna léčby pacientů s DM2 nedostatečně kompenzovaných při léčbě jiným bazálním inzulinem na Gla-300 spojena se zlepšením kompenzace diabetu a snížením rizika hypoglykemie, a to bez nárůstu tělesné hmotnosti a se zvýšením spokojenosti pacientů s léčbou.
The aim of the study was to evaluate the clinical efficacy of insulin glargine 300 U/ml (Gla-300) in the treatment of patients with type 2 diabetes (DM2) insufficiently compensated by basal insulin in the conditions of routine clinical practice in the Czech Republic (TOPAZ study). TOPAZ was a prospective multicenter, non-interventional, 6-month study. Of the 312 patients enrolled in the study, 289 were evaluated at 6 months. The primary endpoint was the change in HbA1c at 6 months. The secondary endpoints were the proportion of patients with HbA1c < 7% (< 53 mmol/mol), the proportion of patients with a decrease in HbA1c of at least 0.5% after 6 months, the change in fasting glucose (FPG), body weight and insulin dose after 3 and 6 months. The incidence of hypoglycaemia, adverse events and patient satisfaction with treatment was also evaluated. HbA1c decreased significantly after 6 months (mean change 0.9 ± 1.1% [–9.9 ± 11.6 mmol/mol]; p < 0.0001). Target HbA1c < 7% was achieved in 17.6% of patients, 66% of patients showed a mean decrease in HbA1c of 0.5 ± 0.8%. After 6 months, FPG (mean change from baseline –1.8 ± 3.1 mmol/l) as well as the incidence of hypoglycaemia decreased by 49 % (p < 0.0001), without weight gain. No significant safety signals were observed. In routine clinical practice, a change in the treatment of patients with DM2 undercompensated with other basal insulin to Gla-300 was associated with improved diabetes compensation and a reduced risk of hypoglycaemia, without weight gain and increased patient satisfaction with treatment.
Cieľ: Porovnať dávky bazálnych analógov, inzulínu Lantus® verzus Levemir®, potrebné na dosiahnutie porovnateľnej glykemickej kontroly. Materiál a metódy: Retrospektívna analýza porovnávajúca dávky bazálnych analógov inzulínu Lantus® verzus Levemir® u n = 1000 náhodne vybratých pacientov liečených týmito inzulínmi v bežnej ambulantnej praxi z celého Slovenska s diabetom mellitom 1. typu (DM 1) a 2. typu (DM 2) na kompletnej substitučnej liečbe inzulínom (bazálny analóg + prandiálny), rozdelených na podskupiny. Podskupina 1. Pacienti po vylúčení pacientov s HbA1c > 10 % a tých, ktorí boli predtým liečení iným porovnávaným bazálnym analógom (napr. pacienti v čase sledovania liečení inzulínom Levemir®, predtým však inzulínom Lantus®). Podskupina 2. Pacienti z podskupiny 1 po vylúčení pacientov s FPG > 10 mmol/l pri dávke bazálneho inzulínu večer < 0,3 U/kg TH pri DM 1 alebo < 0,5 U/kg TH pri DM 2. Podskupina 3. Pacienti z podskupiny 2 s HbA1c < 8,5 % a FPG < 8 mmol/l. Podskupina 4. Pacienti z podskupiny 3, u ktorých bol bazálny analóg podávaný raz denne. Výsledky: Obidva bazálne analógy inzulínu (inzulín Lantus® aj inzulín Levemir®) pri porovnateľnej glykemickej kontrole vyžadovali porovnateľné dávky, a to tak samotných bazálnych analógov, ako aj súvisiacich prandiálnych inzulínov a celodenných dávok inzulínu. Niektoré rozdiely u pacientov s DM 1, ktoré nadobudli v rámci celej skupiny a podskupiny 1 signifikantný rozdiel s nižšími dávkami bazálnych inzulínov u pacientov na inzulíne Lantus® (asi do 8 %) vymizli po homogenizácii pacientov s ohľadom na glykemickú kontrolu a adekvátnosť titrácie. U pacientov s DM 2 dávky oboch bazálnych inzulínov boli vo všetkých porovnávaných skupinách porovnateľné. Podiel pacientov s podaním bazálneho inzulínu 2-krát denne bol takmer vo všetkých podskupinách v ramene pacientov na inzulíne Levemir® signifikantne vyšší než v ramene Lantus®. Súhrn: Výsledky našej analýzy nepotvrdili zásadné rozdiely medzi dávkami porovnávaných bazálnych inzulínov (Lantus® verzus Levemir®). Oba bazálne inzulíny pri porovnateľnej glykemickej kontrole vyžadovali porovnateľné dávky bazálneho aj súvisiaceho prandiálneho inzulínu, a to tak u pacientov s DM 1, ako aj u pacientov s DM 2.
Aim: To compare doses of basal analogues, insulin Lantus versus Levemir, necessary for obtaining comparable glycemic control. Materials and Methods: Retrospective analysis comparing doses of basal analogues of insulin Lantus versus Levemir in n = 1000 randomly selected patients treated with these insulins in ambulatory practice from whole Slovakia, with diabetes mellitus type1 (DM-1) and type 2 (DM-2) in complete substitution treatment with insulin (basal analogue + prandial), divided to subgroups. Subgroup 1. Patients after excluding patients with HbA1c > 10 %, and those before treated with other compared basal analogue (e.g. patients at the time of monitoring treated with insulin Levemir, before with insulin Lantus). Subgroup 2. Patients from the subgroup 1 after excluding patients with FPG > 10 mmol/l in dose of basal insulin in the evening < 0.3 U/kg TH u DM-1 or < 0.5 U/kg TH in DM-2. Subgroup 3. Patients from subgroup 2, with HbA1c < 8.5 % and FPG < 8 mmol/l. Subgroup 4. Patients from subgroup 3 given the basal analogue once a day. Results: both basal analogues of insulin (insulin Lantus and insulin Levemir) in comparable glycemic control required comparable doses of single basal analogies as well as in related prandial insulins and whole day doses of insulin. Some differences in patients with DM-1, obtained within the whole group and subgroup 1 disappeared after homogenization if patients regarding glycemic control and adequate titration. In patients with DM-2 doses of both basal insulins were in all comparable groups comparable. The rate of patients with administration of basal insulin twice a day was almost in all subgroups in the branch of patients on insulin Levemir significantly higher than in the branch Lantus. Summary: Results of our analysis did not prove essential differences between doses of compared basal insulins (Lantus versus Levemir). Both basal insulins in comparable glycemic control required comparable doses of basal and related prandial insulin in patients with DM-1 as well as in patients with DM-2.
... 87 -- 7.1.3 Glykovaný hemoglobin (HbAk) 87 -- 7.1.4 Vyšetření koncentrace glukózy v plazmě nalačno - FPG ...
1. elektronické vydání 1 online zdroj (212 stran)
Ošetřovatelská péče je u osoby s diabetem zaměřena zejména na udržení a podporu zdraví a na rozvoj soběstačnosti a významně se podílí na prevenci, diagnostice a terapii diabetu.
- Klíčová slova
- Ošetřovatelství - postupy, první pomoc,
- MeSH
- diabetes mellitus diagnóza epidemiologie etiologie klasifikace patofyziologie terapie MeSH
- diabetická dieta MeSH
- hypoglykemika terapeutické užití MeSH
- komplikace diabetu klasifikace MeSH
- ošetřovatelská diagnóza metody MeSH
- ošetřovatelská péče klasifikace metody MeSH
- pohybová aktivita MeSH
- riziko MeSH
- selfmonitoring glykemie MeSH
- NLK Obory
- diabetologie
- ošetřovatelství
... 87 -- 7.1.3 Glykovaný hemoglobin (HbAk) 87 -- 7.1.4 Vyšetření koncentrace glukózy v plazmě nalačno - FPG ...
Sestra
1. vydání 204 stran, iv stran obrazové přílohy : : ilustrace ; ; 21 cm
Ošetřovatelská péče je u osoby s diabetem zaměřena zejména na udržení a podporu zdraví a na rozvoj soběstačnosti a významně se podílí na prevenci, diagnostice a terapii diabetu.
- Publikační typ
- monografie MeSH
- učebnice MeSH