On-line SPE
Dotaz
Zobrazit nápovědu
Advanced solid phase extraction (SPE) fibrous sorbents including polyethylene, polypropylene poly (hydroxybutyrate), and polyamide 6 nanofibers, polycaprolactone microfibers/nanofibers, polycaprolactone microfibers/polyvinylidene difluoride nanofibers, and poly (hydroxybutyrate) microfibers/polypropylene microfibers composites, as well as commercial molecularly imprinted polymers and restricted access media sorbent were compared in terms of bisphenols extraction from milk and their clean-up efficiency. Three on-line SPE-HPLC methods were completely validated for the extraction and detection of bisphenols A, AF, C, A diglycidyl ether, and F diglycidyl ether in bovine milk. Polycaprolactone composite nanofibers compared favorably to restricted access media, enabled excellent clean-up of bisphenols from the proteinaceous matrix, and yielded recoveries 98.0-124.5% and 93.0-115.0%, respectively, with RSD less than 10%. Total analysis time including on-line SPE step lasted only 12 min, which represents a significant reduction in time compared with previously reported as well as official European Union and AOAC methods defined for the determination of bisphenols in various matrices.
- MeSH
- adsorpce MeSH
- ethery MeSH
- extrakce na pevné fázi metody MeSH
- hydroxybutyráty MeSH
- mléko MeSH
- molekulárně imprintované polymery MeSH
- molekulový imprinting * metody MeSH
- nanovlákna * chemie MeSH
- polypropyleny MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques. It mainly focuses on modern techniques such as extraction across supported liquid membrane, electroextraction, single drop microextraction, head space microextraction, and microdialysis with high spatial and temporal resolution. Finally, the design of sequential electrophoretic analysers and fabrication of SPE microcartridges with monolithic and molecularly imprinted polymeric sorbents are discussed. Applications include the monitoring of metabolites, neurotransmitters, peptides and proteins in body fluids and tissues to study processes in living organisms, as well as the monitoring of nutrients, minerals and waste compounds in food, natural and wastewater.
- MeSH
- elektroforéza kapilární metody MeSH
- elektroforéza mikročipová * metody MeSH
- mikrodialýza MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
A double-stage Lab-In-Syringe automated extraction procedure coupled online to HPLC for the determination of four sulfonamides in urine has been developed. Our method is based on homogeneous liquid-liquid extraction at pH 3 using water-miscible acetonitrile with induction of phase separation by the addition of a saturated solution of kosmotropic salts MgSO4 and NaCl. The procedure allowed extraction of the moderately polar model analytes and the use of a solvent that is compatible with the used separation technique. The automated sample preparation system based on the stirring-assisted Lab-In-Syringe approach was coupled on-line with HPLC-UV for the subsequent separation of the sulfonamide antibiotics. To improve both preconcentration factor and extract cleanup, the analytes were trapped at pH 10 in an anion-exchange resin cartridge integrated into the HPLC injection loop thus achieving a double-stage sample clean-up. Analytes were eluted using an acidic HPLC mobile phase in gradient elution mode. Running the analytes separation and the two-step preparation of the following sample in parallel reduced the total time of analysis to mere 13.5 min. Limits of detection ranged from 5.0 to 7.5 μg/L with linear working ranges of 50-5000 μg/L (r2 > 0.9997) and RSD ≤ 5% (n = 6) at a concentration level of 50 μg/L. Average recovery values were 102.7 ± 7.4% after spiking of urine with sulfonamides at concentrations of 2.5 and 5 mg/L followed by 5 times dilution. To the best of our knowledge, the use of Lab-In-Syringe for the automation of coupled homogeneous liquid-liquid extraction and SPE for preparation of the complex matrices suitable for separation techniques is here presented for the first time.
Oxandrolone, a synthetic testosterone analog, is used for the treatment of several diseases associated with weight loss. Unfortunately, oxandrolone is abused by many athletes and bodybuilders due to its strong anabolic effect. We have developed and validated a highly sensitive and rapid on-line SPE-UHPLC-MS/MS method for the determination of oxandrolone and simultaneous identification of its major metabolite 17-epi-oxandrolone in urine matrices. Enrichment of the analytes via an integrated solid-phase extraction was achieved using an Acquity UPLC BEH C18 Column. Subsequently, the chromatographic separation of the on-line preconcentrated sample fraction was achieved using an Acquity HSS T3 C18 Column. For the structural identification of these analytes, a high-resolution mass spectrometer Synapt-G2Si coupled to the Acquity M-class nano-LC system with ionKey source was used. A highly sensitive determination of oxandrolone was achieved using a tandem quadrupole mass spectrometer XEVO TQD. The method was successfully validated in the linear range of oxandrolone from 81.63 pg·mL-1 (limit of quantification, LOQ) to 5000 pg·mL-1 in the human urine matrix. It was applied to the analysis of real urine samples obtained from a healthy volunteer after the oral administration of one dose (10 mg) of oxandrolone. Concentration vs. time dependence was tested in the time interval of 4 h-12 days (after oral administration) to demonstrate the ability of the method to detect the renal elimination of oxandrolone from the human body. Favorable performance parameters along with successful application indicate the usefulness of the proposed method for its routine use in antidoping control labs.
According to the EU legislation, ochratoxin A contamination is controlled in wines. Tokaj wine is a special type of sweet wine produced from botrytized grapes infected by "noble rot" Botrytis cinerea. Although a high contamination was reported in sweet wines and noble rot grapes could be susceptible to coinfection with other fungi, including ochratoxigenic species, no screening of Tokaj wines for mycotoxin contamination has been carried out so far. Therefore, we developed an analytical method for the determination of ochratoxin A (OTA) and ochratoxin B (OTB) involving online SPE coupled to HPLC-FD using column switching to achieve the fast and sensitive control of mycotoxin contamination. The method was validated with recoveries ranging from 91.6% to 99.1% with an RSD less than 2%. The limits of quantification were 0.1 and 0.2 µg L-1 for OTA and OTB, respectively. The total analysis time of the online SPE-HPLC-FD method was a mere 6 min. This high throughput enables routine analysis. Finally, we carried out an extensive investigation of the ochratoxin contamination in 59 Slovak Tokaj wines of 1959-2017 vintage. Only a few positives were detected. The OTA content in most of the checked wines did not exceed the EU maximum tolerable limit of 2 µg L-1, indicating a good quality of winegrowing and storing.
- MeSH
- analýza potravin metody MeSH
- chromatografie kapalinová MeSH
- extrakce na pevné fázi MeSH
- kontaminace potravin analýza MeSH
- ochratoxiny analýza MeSH
- řízení kvality MeSH
- senzitivita a specificita MeSH
- víno analýza MeSH
- Vitis chemie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
On-line SPE HPLC method using nanofibrous sorbents for the extraction and determination of resveratrol in wine was developed and validated. Different types of nanofibrous and microfibrous polymers were tested and compared with commercial monolithic C18 sorbent. Polyamide and polyacrylonitrile nanofibers and composite materials composed of respective polycaprolactone and poly(vinylidene difluoride) nanofibers at microfibrous scaffold were included among tested materials. Two different polycaprolactone-based materials were prepared and their effect on the extraction properties studied. Alternatively, dopamine-coated polycaprolactone fibers were also used. Poly(vinylidene difluoride) nanofibers/polycaprolactone microfibers composite was found as the most effective sorbent and utilized for the method validation. Resveratrol in red wine was determined using our validated on-line SPE HPLC method.
Polycaprolactone composite nanofibers coated with a polydopamine layer are introduced as a new type of absorption material for on-line solid phase extraction (SPE) in chromatographic system. A hybrid technology combining the electrospinning and melt blowing was used for the preparation of 3D-structured microfiber/nanofibrous polycaprolactone composite. The dopamine coating was then applied to functionalize the micro/nanofibers. Polydopamine-coated polycaprolactone fibers were tested as an extraction phase in on-line SPE prior to HPLC separation and UV detection. Four groups of biologically active substances including bisphenols (Bisphenol S, Bisphenol AF, Bisphenol A, Bisphenol C, Bisphenol AP, Bisphenol Z, Bisphenol BP, and Bisphenol M), betablockers (Timolol, Metoprolol, Labetalol, and Propranolol), nonsteroidal antiphlogistic drugs (Salicylic acid, Ketoprofen, Naproxen, Indomethacin, Diclofenac, Ibuprophen, and Meclofenamic acid), and phenolic acids (Chlorogenic acid, Caffeic acid, Sinapic acid, m-Coumaric acid, Benzoic acid, and Cinnamic acid) were used as the model analytes. Neat and coated fibers were compared and applied as sorbents for the on-line extraction set-up. Both materials produced good extraction potential for the determination of bisphenols and nonsteroidal drugs in model biological and environmental samples including river water, human urine, and blood serum. However, the polydopamine layer significantly increased the extraction efficiency of polar drugs. Typical repeatability of on-line extraction procedure on polydopamine coated fibers was in the range 0.12-4.11% for bisphenols, 0.55-1.41% for antiphlogistic drugs, 0.59-2.52% for phenolic acids, and 1.01-1.65% for betablockers. Graphical abstract Schematic representation of polycaprolactone composite nanofibers coated with a polydopamine layer as an advanced absorption material for on-line solid phase extraction in chromatography.
- MeSH
- antiflogistika nesteroidní analýza izolace a purifikace MeSH
- beta blokátory analýza izolace a purifikace MeSH
- chemické látky znečišťující vodu analýza izolace a purifikace MeSH
- cinnamáty analýza izolace a purifikace MeSH
- extrakce na pevné fázi metody MeSH
- fenoly analýza izolace a purifikace MeSH
- indoly chemie MeSH
- nanovlákna chemie MeSH
- polyestery chemie MeSH
- polymerizace MeSH
- polymery chemie MeSH
- řeky chemie MeSH
- reprodukovatelnost výsledků MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Various types of micropollutants, e.g., pharmaceuticals and their metabolites and resistant strains of pathogenic microorganisms, are usually found in hospital wastewaters. The aim of this paper was to study the presence of 74 frequently used pharmaceuticals, legal and illegal drugs, and antibiotic-resistant bacteria in 5 hospital wastewaters in Slovakia and Czechia and to compare the efficiency of several advanced oxidations processes (AOPs) for sanitation and treatment of such highly polluted wastewaters. The occurrence of micropollutants and antibiotic-resistant bacteria was investigated by in-line SPE-LC-MS/MS technique and cultivation on antibiotic and antibiotic-free selective diagnostic media, respectively. The highest maximum concentrations were found for cotinine (6700 ng/L), bisoprolol (5200 ng/L), metoprolol (2600 ng/L), tramadol (2400 ng/L), sulfamethoxazole (1500 ng/L), and ranitidine (1400 ng/L). In the second part of the study, different advanced oxidation processes, modified Fenton reaction, ferrate(VI), and oxidation by boron-doped diamond electrode were tested in order to eliminate the abovementioned pollutants. Obtained results indicate that the modified Fenton reaction and application of boron-doped diamond electrode were able to eliminate almost the whole spectrum of selected micropollutants with efficiency higher than 90%. All studied methods achieved complete removal of the antibiotic-resistant bacteria present in hospital wastewaters.
- MeSH
- bakteriální léková rezistence MeSH
- bor MeSH
- chemické látky znečišťující vodu analýza MeSH
- chromatografie kapalinová MeSH
- diamant MeSH
- elektrody MeSH
- léčivé přípravky analýza MeSH
- nemocnice MeSH
- odpad tekutý - odstraňování přístrojové vybavení metody MeSH
- odpadní voda analýza chemie mikrobiologie MeSH
- oxidace-redukce MeSH
- peroxid vodíku chemie MeSH
- tandemová hmotnostní spektrometrie MeSH
- zakázané drogy analýza MeSH
- zdravotnický odpad MeSH
- železo chemie MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
- Slovenská republika MeSH