PURPOSE OF THE STUDY Periprosthetic distal femoral fractures (PDFF) constitute an unpleasant complication in patients with a total knee replacement (TKR). The incidence reported in literature is 0.3-2.5 %. The number of periprosthetic knee fractures has been increasing due to the ageing of population, a growing number of implants, a longer life expectancy of patients, a more intensive physical activity of patients, and osteoporosis. Most of these fractures are treated surgically, non-surgical treatment is reserved solely for patients unable to undergo a surgery for general health conditions. MATERIAL AND METHODS Our retrospective study evaluated the group of patients with PDFF who were treated at out department in the period 2007- 2016 and 2,975 primary TKR were performed. The total number of patients with PDFF was 56. The mean age of patients with PDFF was 77 years (56-94 years) and at the time of fracture the mean age was 71 years in men and 78 years in women. The average time from the TKR to periprosthetic fracture was 8.2 years (0-20 years). The fractures were assessed using the Su classification modified by Krbec. RESULTS A primary TKR was performed in 46 cases for gonarthrosis, in 6 cases for rheumatoid arthritis and in 4 cases for secondary, post-traumatic gonarthrosis. The average incidence of periprosthetic distal femoral fractures was 5-6 cases per year. Women represented 86 %, men 14 %. Su Type I fracture was diagnosed in 25 % of cases, Su Type II fractures in 71 %, and Su Type III fractures 4 %. 52 patients with PDFF were treated surgically, in 4 cases conservative treatment was opted for. The average treatment time of PDFF to healing by callus formation was 6.6 months (3-12 months). Mortality during the first 3 months after osteosynthesis of PDFF was 9 %. A failure of osteosynthesis of PDFF was reported in 4 cases. DISCUSSION Multiple classification systems were developed to assess these fractures. The most appropriate we consider the classification of Su et al. classifying the PDFF into 3 groups, namely based on the height of the fracture line relative to the femoral component. Osteosynthesis by retrograde femoral nail is indicated for periprosthetic fractures, with sufficient bone mass in distal femur, which allows stable distal fixation. The new generation of anatomically shaped angular stable implants gives us yet another option for osteosynthesis of PDFF. Many studies point at the advantages of these implants in osteoporotic bone as against the conventional plates. CONCLUSIONS The number of PDFF has been increasing. The main methods of internal osteosynthesis continue to be the angular stable plates and the retrograde femoral nail. Preoperative planning is important to determine the type and dimensions of the existing femoral component and to distinguish whether or not it has come loose. The choice of the implant may depend on the bone mass available for distal fixation. The retrograde femoral nail is usually the most suitable method of treatment for proximal PDFF (Su Type I). The angular stable plates can be used for PDFF originating at the femoral component (Su Type II and Type III). Very distal fractures classified as Su Type III with a loose femoral component require a revision surgery with a TKR with stems. The surgeon should be prepared for a revision surgery if the intraoperative finding is more complicated than anticipated based on the preoperative radiograph. Key words:total knee arthroplasty, periprosthetic fracture, osteosynthesis.
- MeSH
- fraktury femuru etiologie chirurgie terapie MeSH
- kostní destičky MeSH
- lidé středního věku MeSH
- lidé MeSH
- osteoporotické fraktury etiologie chirurgie terapie MeSH
- periprotetické fraktury etiologie chirurgie terapie MeSH
- reoperace MeSH
- retrospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- totální endoprotéza kolene škodlivé účinky MeSH
- vnitřní fixace fraktury škodlivé účinky metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
1st edition 541 stran : ilustrace (převážně barevné), portréty, tabulky ; 24 cm
- Konspekt
- Ortopedie. Chirurgie. Oftalmologie
- NLK Obory
- chirurgie
- experimentální medicína
- NLK Publikační typ
- kolektivní monografie
PURPOSE OF THE STUDY: A comparison of radiological and clinical results between dorsal pelvic segment stabilization with a transiliac internal fixator (TIFI) and that with two iliosacral screws (IS). MATERIAL AND METHODS: In this prospective study, both the TIFI and the IS group had 32 patients. The majority of injuries were assessed as type C1.3 because only patients with a high-energy mechanism of injury were included. Radiological results were evaluated according to the Matta scoring system and clinical outcome using the Majeed score and the Pelvic Outcome Score. Categorical data were evaluated by the two-sided Fisher's exact test or Pearson's χ2 test and continuous data by Student's t-test. A test result with p<0.05 was considered statistically significant. RESULTS: In the TIFI group, the mean posterior displacement was 2.2 mm, in the IS group it was 1.9 mm (p=0.58542). The pelvic outcome scores in the TIFI group were: excellent, 28%; good, 12%; fair, 48.0%; and poor, 4 %; in the IS group they were: excellent, 11.1%; good, 22.2%; fair, 66.7%; and poor, 0.0% (p=0.51731). The Majeed scores were as follows: excellent, 56.0%; good, 16.0%; fair, 20.0%; poor 8.0 % for the TIFI group and excellent, 50.0%; good, 27.8%; fair, 11.1%; and poor, 11.1% for the IS group (p=0.70187). Within the total, average Majeed score was 80.64 points in TIFI, 80.67 in IS (p=0.99654). In a sub-analysis of unilateral transforaminal fractures (Pohlemann type II), the average score for TIFI was 82.8 points and only 53.5 points for IS; the differences were statistically significant (p=0.04517). No intraoperative complications were associated with TIFI and one injury to the superior gluteal artery (3.1%) and two iatrogenic neurological injuries with IS (6.3%; p=0.23810). In the TIFI group, the fixator was removed without complications. In the IS group, post-operative wound bleeding following screw removal occurred in three patients (20.0%; p=0.22414), complete extraction of screws and washers was successful only in seven patients (46.7%), washers were left in situ in six patients (40.0 %) and IS removal was not possible in two patients (13.3%). The difference in complications between the groups was highly significant (p=0.00220). DISCUSSION: The results of our study are in agreement with those of the relevant studies published recently as well as with the outcomes of transiliac plate fixation reported in the literature. TIFI implantation is preferred in transforaminal and central sacral fractures because, unlike iliosacral screws, it carries a low risk of excessive compression of the sacral foramina and iatrogenic neurological injury. There were no significant differences in clinical and radiological findings between TIFI and IS procedures. Only in unilateral transforaminal fracture the TIFI stabilization had better outcome, as shown by the Majeed score. The IS fixation was associated with a higher rate of complications not only in primary implantation, but also at implant removal. CONCLUSIONS: The TIFI technique is superior to the IS procedure in fixation of unilateral transforaminal fractures and provides a reasonable alternative to the existing types of minimally invasive fixation.
- MeSH
- fraktury kostí radiografie chirurgie MeSH
- interní fixátory * MeSH
- kostní šrouby * MeSH
- lidé MeSH
- miniinvazivní chirurgické výkony přístrojové vybavení metody MeSH
- os ilium chirurgie MeSH
- pánevní kosti zranění radiografie chirurgie MeSH
- prospektivní studie MeSH
- vnitřní fixace fraktury přístrojové vybavení metody MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- hodnotící studie MeSH
- srovnávací studie MeSH
PURPOSE: Vertically unstable sacral transforaminal fractures can be stabilized with a transiliac internal fixator (TIFI) or two iliosacral screws (IS). This study was designed to compare stiffness between TIFI and IS. METHODS: Using CT images finite element model of the pelvis was developed. Denis II type fracture was simulated and fixed either with TIFI or two IS. The sacral base was loaded vertically (250-500 N), displacement magnitudes on medial and lateral fracture surface and the maximum bone stress were calculated. The intact pelvis was used as a reference. Stiffness was determined by linear regression of load and displacement, computed stiffness ratio %. The von Mises stress was expressed as % ratio, evaluation of colour mapping was made. RESULTS: The mean stiffness ratio medially in TIFI was 75.22%, in IS 46.54% (p = 0.00005), laterally in TIFI 57.88%, in IS 44.74% ( p = 0.03996). The von Mises stress ratio of TIFI was 139.27%, of IS 565.35% ( p < 0.00001). CONCLUSIONS: Significantly higher stiffness and lower stress were found in TIFI model. TIFI provides a lower risk of over-compression of the fracture line in comparison with IS. TIFI thus exhibits superiority for fixation of trans- foraminal fractures, particularly with comminutive zone.
- MeSH
- analýza metodou konečných prvků MeSH
- biomechanika MeSH
- dopravní nehody MeSH
- fraktury kostí chirurgie MeSH
- fraktury páteře chirurgie MeSH
- interní fixátory * MeSH
- kostní šrouby * MeSH
- křížová kost chirurgie MeSH
- lidé MeSH
- lineární modely MeSH
- os ilium chirurgie MeSH
- pevnost v tlaku MeSH
- počítačová rentgenová tomografie MeSH
- regresní analýza MeSH
- statistické modely MeSH
- testování materiálů MeSH
- vnitřní fixace fraktury přístrojové vybavení metody MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
OBJECTIVE: To evaluate the incidence and extent of vaginal and perineal trauma among primiparous women after mediolateral and lateral episiotomy. METHODS: In a prospective randomized study at University Hospital Pilsen, Czech Republic, 790 consecutive primiparous women were enrolled between April 2010 and April 2012. Mediolateral episiotomy (MLE) followed an angle of at least 60° from the midline. Lateral episiotomy (LE) started 1-2 cm laterally from the midline and was directed toward the ischial tuberosity. A rectal examination was performed before episiotomy repair. RESULTS: MLE was performed for 390 women, and LE for 400. The groups did not differ in maternal or neonatal characteristics. No difference was found in incidence or extent of vaginal and perineal trauma; or in additional perineal (1.8% vs 1.5%, P=0.6) or vaginal (8.5% vs 10.6%, P=0.2) trauma continuing along the episiotomy incision. The incidence of anal sphincter injury did not differ between MLE and LE (1.5% vs 1.3%, P=0.7). MLE was associated with shorter repair times (P<0.05), less suturing material (P<0.05), and shorter distances from the anus (P<0.001). CONCLUSION: Risk of additional vaginal and perineal trauma, and anal sphincter injury after adequately performed mediolateral episiotomy is relatively low and corresponds to that of lateral episiotomy.
- MeSH
- anální kanál zranění MeSH
- délka operace MeSH
- dospělí MeSH
- epiziotomie škodlivé účinky metody MeSH
- krvácení při operaci statistika a číselné údaje MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- perineum zranění MeSH
- těhotenství MeSH
- vagina zranění MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
OBJECTIVE: To evaluate short-term perineal pain among primiparous women after mediolateral episiotomy (MLE) and lateral episiotomy (LE). METHODS: The prospective randomized study was conducted in the Czech Republic during 2010-2012. Consecutive primiparous women who gave birth at or after 37 weeks of pregnancy and had indications for an episiotomy were enrolled and randomly assigned to undergo MLE or LE. Patients were unaware of the episiotomy type performed. The primary outcomes were pain at 24 hours, 72 hours, and 10 days post partum, measured by a visual analog scale, verbal rating scale, interference with activities of daily living, and amount of analgesic use. RESULTS: The analysis included 266 women who underwent MLE and 297 women who underwent LE. Complete relief of pain was observed in 6 (2.3%) of 266 women after 24 hours, 21 (8.0%) of 264 after 72 hours, and 77 (29.1%) of 265 after 10 days in the MLE group, and in 11 (3.9%) of 285, 23 (7.7%) of 297, and 78 (26.4%) of 295 in the LE group, respectively (P=0.36). There were no significant differences in overall pain scores from any rating system or in the amount of analgesics used. CONCLUSION: Incidence and extent of pain in the first 10 days after LE correspond to those after adequately performed MLE.
- MeSH
- analgetika terapeutické užití MeSH
- bolest farmakoterapie etiologie MeSH
- epiziotomie škodlivé účinky metody MeSH
- lidé MeSH
- měření bolesti MeSH
- poporodní období MeSH
- průzkumy a dotazníky MeSH
- těhotenství MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
INTRODUCTION AND HYPOTHESIS: Comparison of the modifications of the Viennese method of manual perineal protection (VMPP) and hands-off delivery techniques by applying basic principles of mechanics with assessments of tensions within perineal structures using a novel biomechanical model of the perineum. Evaluation of the role of the precise placements of the accoucheur's posterior (dominant) thumb and index finger in perineal tissue tension when performing a modified Viennese method of MPP. METHODS: We carried out an experimental study on a biomechanical model of the perineum at NTIS (New Technologies for Information Society, Pilsen, Czech Republic). Hands-off and 38 variations of VMPP were simulated during vaginal delivery with the finite element model imitating a clinical lithotomy position. RESULTS: The main outcome measures were quantity and extent of strain/tension throughout the perineal body during vaginal delivery. Stress distribution between modifications of VMPP showed a wide variation in peak perineal tension from 72 to 102 % compared with 100 % for the "hands-off" technique. Extent of reduction depended on the extent of finger movement across a horizontal, transverse x-axis, and on final finger position on a vertical, antero-posterior y-axis. The most effective modification of VMPP was initial position of fingers 12 cm apart (x = ±6) on the x-axis, 2 cm anteriorly from the posterior fourchette (y = +2) on the y-axis with 1cm movement of both finger and thumb toward the midline on the x-axis (Δx = 1) with no movement on the y-axis (Δy = 0). CONCLUSIONS: In a biomechanical assessment with simulation of vaginal delivery, exact placement of fingertips on the perineal skin, together with their co-ordinated movement, plays an important role in the extent of reduction of perineal tension.
- MeSH
- biologické modely MeSH
- biomechanika MeSH
- lidé MeSH
- perineum zranění MeSH
- počítačová simulace MeSH
- porod MeSH
- prsty ruky * MeSH
- rány a poranění prevence a kontrola MeSH
- vedení porodu metody MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH