BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.
- MeSH
- elektrokardiografie MeSH
- fibrilace komor epidemiologie etiologie terapie MeSH
- funkce levé komory srdeční MeSH
- komorová tachykardie * epidemiologie etiologie terapie MeSH
- lidé MeSH
- srdeční resynchronizační terapie * škodlivé účinky MeSH
- srdeční selhání * epidemiologie terapie MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure. Although these devices effectively improve survival, atrial and ventricular arrhythmias are common with a prevalence of 20-50% at one year after LVAD implantation. Arrhythmias predispose these patients to additional risk and are associated with considerable morbidity from recurrent implantable cardioverter-defibrillator shocks, progressive failure of the unsupported right ventricle, and herald an increased risk of mortality. Management of patients with arrhythmias and LVAD differs in many aspects from the general population heart failure patients. These include ruling out the reversible causes of arrhythmias that in LVAD patients may include mechanical irritation from the inflow cannula and suction events. For patients with symptomatic arrhythmias refractory to medical treatment, catheter ablation might be relevant. There are specific technical and procedural challenges perceived to be unique to LVAD-related ventricular tachycardia (VT) ablation such as vascular and LV access, signal filtering, catheter manoeuvrability within decompressed chambers, and electroanatomic mapping system interference. In some patients, the arrhythmogenic substrate might not be readily accessible by catheter ablation after LVAD implantation. In this regard, the peri-implantation period offers a unique opportunity to surgically address arrhythmogenic substrate and suppress future VT recurrences. This document aims to address specific aspects of the management of arrhythmias in LVAD patients focusing on anti-arrhythmic drug therapy and ablations.
- MeSH
- antiarytmika * terapeutické užití MeSH
- funkce levé komory srdeční MeSH
- katetrizační ablace * metody MeSH
- komorová tachykardie terapie chirurgie patofyziologie MeSH
- konsensus MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- rizikové faktory MeSH
- srdeční arytmie * terapie patofyziologie diagnóza MeSH
- srdeční selhání * terapie patofyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- směrnice pro lékařskou praxi MeSH
- Geografické názvy
- Evropa MeSH
AIMS: Wearable cardioverter-defibrillators (WCDs) are indicated in patients at risk of sudden cardiac arrest who are not immediate candidates for implantable defibrillator therapy. Limitations of existing WCDs include poor compliance and high false alarm rates. The Jewel is a novel patch-WCD (P-WCD) that addresses these limitations with an adhesive-based design for near-continuous wear and a machine learning algorithm designed to minimize inappropriate detections. This was a first-in-human study of the Jewel P-WCD conducted in an electrophysiology (EP) lab to determine the safety and effectiveness of the device in terminating ventricular tachycardia/ventricular fibrillation (VT/VF) with a single shock. The aim was to evaluate the safety and effectiveness of terminating VT/VF with a single shock using the Jewel P-WCD. METHODS AND RESULTS: This was a first-in-human, prospective, single-arm, single-centre study in patients scheduled for an EP procedure in which VT/VF was expected to either spontaneously occur or be induced. The Jewel P-WCD was placed on consented patients; upon confirmation of VT/VF, a single shock (150 J) was delivered via the device. A group sequential design and Pocock alpha spending function was used to measure the observed proportion of successful VT/VF single-shock terminations. The endpoint was achieved if the lower confidence limit exceeded the performance goal of 62%, using a one-sided lower 97.4% exact confidence bound. Of 18 eligible subjects, 16 (88.9%, 97.4% confidence bound: 65.4%) were successfully defibrillated with a single shock, exceeding the primary endpoint performance goal with no adverse events. CONCLUSION: This first-in-human evaluation of the Jewel P-WCD demonstrated the safety and effectiveness of terminating VT/VF. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/; Unique identifier: NCT05490459.
- MeSH
- defibrilátory * MeSH
- design vybavení MeSH
- dospělí MeSH
- elektrická defibrilace * přístrojové vybavení škodlivé účinky MeSH
- fibrilace komor * terapie diagnóza MeSH
- komorová tachykardie * terapie diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- nositelná elektronika * MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) may cause sudden cardiac death (SCD) despite medical therapy. Therefore, implantable cardioverter-defibrillators (ICDs) are commonly advised. However, there is limited data on the outcomes of ICD use in children. OBJECTIVE: The purpose of this study was to compare the risk of arrhythmic events in pediatric patients with CPVT with and without an ICD. METHODS: We compared the risk of SCD in patients with RYR2 (ryanodine receptor 2) variants and phenotype-positive symptomatic CPVT patients with and without an ICD who were younger than 19 years and had no history of sudden cardiac arrest at phenotype diagnosis. The primary outcome was SCD; secondary outcomes were composite end points of SCD, sudden cardiac arrest, or appropriate ICD shocks with or without arrhythmic syncope. RESULTS: The study included 235 patients, 73 with an ICD (31.1%) and 162 without an ICD (68.9%). Over a median follow-up of 8.0 years (interquartile range 4.3-13.4 years), SCD occurred in 7 patients (3.0%), of whom 4 (57.1%) were noncompliant with medications and none had an ICD. Patients with ICD had a higher risk of both secondary composite outcomes (without syncope: hazard ratio 5.85; 95% confidence interval 3.40-10.09; P < .0001; with syncope: hazard ratio 2.55; 95% confidence interval 1.50-4.34; P = .0005). Thirty-one patients with ICD (42.5%) experienced appropriate shocks, 18 (24.7%) inappropriate shocks, and 21 (28.8%) device-related complications. CONCLUSION: SCD events occurred only in patients without an ICD and mostly in those not on optimal medical therapy. Patients with an ICD had a high risk of appropriate and inappropriate shocks, which may be reduced with appropriate device programming. Severe ICD complications were common, and risks vs benefits of ICDs need to be considered.
- MeSH
- defibrilátory implantabilní * MeSH
- dítě MeSH
- komorová tachykardie * terapie patofyziologie MeSH
- lidé MeSH
- mladiství MeSH
- náhlá srdeční smrt * prevence a kontrola etiologie MeSH
- následné studie MeSH
- předškolní dítě MeSH
- retrospektivní studie MeSH
- ryanodinový receptor vápníkového kanálu genetika MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.
- MeSH
- defibrilátory implantabilní * MeSH
- incidence MeSH
- komorová tachykardie * diagnóza terapie komplikace MeSH
- lidé MeSH
- rizikové faktory MeSH
- srdeční arytmie diagnóza terapie MeSH
- srdeční selhání * komplikace MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Asie MeSH
BACKGROUND: Ventricular tachycardia (VT) and ventricular fibrillation (VF) are life-threatening conditions and can be refractory to conventional drug and device interventions. Stellate ganglion blockade (SGB) has been described as an adjunct, temporizing intervention in patients with refractory ventricular arrhythmia. We examined the association of SGB with VT/VF in a multicenter registry. OBJECTIVES: This study examined the efficacy of SGB for treatment/temporization of refractory VT/VF. METHODS: The authors present the first analysis from a multicenter registry of patients treated for refractory ventricular arrhythmia at a clinical site in the Czech Republic and the United States. Data were collected between 2016 and 2022. SGB was performed at the bedside by anesthesiologists and/or cardiologists. Outcomes of interest were VT/VF burden and defibrillations at 24 hours before and after SGB. RESULTS: In total, there were 117 patients with refractory ventricular arrhythmias treated with SGB at Duke (n = 49) and the Institute for Clinical and Experimental Medicine (n = 68). The majority of patients were male (94.0%), were White (87.2%), and had an implantable cardioverter-defibrillator (70.1%). The most common etiology of heart disease was ischemic cardiomyopathy (52.1%), and monomorphic VT was the most common morphology (70.1%). Within 24 hours before SGB (0-24 hours), the median episodes of VT/VF were 7.5 (Q1-Q3: 3.0-27.0), and 24 hours after SGB, the median decreased to 1.0 (Q1-Q3: 0.0-4.5; P < 0.001). At 24 hours before SGB, the median defibrillation events were 2.0 (Q1-Q3: 0.0-8.0), and 24 hours after SGB, the median decreased to 0.0 (Q1-Q3: 0.0-1.0; P < 0.001). CONCLUSIONS: In the largest cohort of patients with treatment-refractory ventricular arrhythmia, we demonstrate that SGB use was associated with a reduction in the ventricular arrhythmia burden and need for defibrillation therapy.
- MeSH
- blokáda autonomních nervů * metody MeSH
- defibrilátory implantabilní MeSH
- dospělí MeSH
- fibrilace komor * terapie MeSH
- ganglion stellatum * MeSH
- komorová tachykardie * terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- registrace MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika MeSH
- Spojené státy americké MeSH
AIMS: To predict worsening heart failure hospitalizations (WHFHs) in patients with implantable defibrillators and remote monitoring, the HeartInsight algorithm (Biotronik, Berlin, Germany) calculates a heart failure (HF) score combining seven physiologic parameters: 24 h heart rate (HR), nocturnal HR, HR variability, atrial tachyarrhythmia, ventricular extrasystoles, patient activity, and thoracic impedance. We compared temporal trends of the HF score and its components 12 weeks before a WHFH with 12-week trends in patients without WHFH, to assess whether trends indicate deteriorating HF regardless of alert status. METHODS AND RESULTS: Data from nine clinical trials were pooled, including 2050 patients with a defibrillator capable of atrial sensing, ejection fraction ≤ 35%, NYHA class II/III, no long-standing atrial fibrillation, and 369 WHFH from 259 patients. The mean HF score was higher in the WHFH group than in the no WHFH group (42.3 ± 26.1 vs. 30.7 ± 20.6, P < 0.001) already at the beginning of 12 weeks. The mean HF score further increased to 51.6 ± 26.8 until WHFH (+22% vs. no WHFH group, P = 0.003). As compared to the no WHFH group, the algorithm components either were already higher 12 weeks before WHFH (24 h HR, HR variability, thoracic impedance) or significantly increased until WHFH (nocturnal HR, atrial tachyarrhythmia, ventricular extrasystoles, patient activity). CONCLUSION: The HF score was significantly higher at, and further increased during 12 weeks before WHFH, as compared to the no WHFH group, with seven components showing different behaviour and contribution. Temporal trends of HF score may serve as a quantitative estimate of HF condition and evolution prior to WHFH.
- MeSH
- defibrilátory implantabilní * MeSH
- extrasystoly MeSH
- hospitalizace MeSH
- komorová tachykardie * diagnóza terapie MeSH
- lidé MeSH
- srdeční selhání * diagnóza terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- MeSH
- defibrilátory implantabilní MeSH
- hypertenze farmakoterapie komplikace MeSH
- komorová tachykardie terapie MeSH
- lidé MeSH
- senioři MeSH
- zástava srdce mimo nemocnici * terapie MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
BACKGROUND: Primary preventive implantation of implantable defibrillator (ICD) is according to current guidelines indicated in patients with heart failure NYHA (New York Heart Association) class II/III and LVEF <35%. Thanks to advances in heart failure pharmacotherapy, a decrease in mortality could render a benefit of ICD insufficient to justify its implantation in some patients. METHODS: Study design: multicenter, prospective, randomized, controlled trial evaluating the benefit of implantation of Cardiac Resynchronization and Defibrillator Therapy (CRT-D) or CRT Alone (CRT-P) in non-ischemic patients with reduced left ventricle ejection fraction (LVEF) and optimal pharmacotherapy without significant mid-wall myocardial fibrosis detected by cardiac magnetic resonance (CMR). The primary end-point: Re-hospitalization for heart failure, ventricular tachycardia, major adverse cardiac events (MACE). The secondary end-points: Sudden cardiac death, cardiovascular death, resuscitated cardiac arrest or sustained ventricular tachycardia, device-related complications, and change in quality of life. Course of the study: After a pharmacotherapy is optimized and significant mid-wall myocardial fibrosis excluded, patients will be randomized 1:1 to CRT-P or CRT-D implantation. DISCUSSION: If our hypothesis is confirmed, this could provide evidence for the management of these patients with a significant impact on common daily praxis and health care expenditures. TRIAL REGISTRATION: CLINICALTRIALS: gov, NCT04139460.
- MeSH
- defibrilátory implantabilní * MeSH
- dilatační kardiomyopatie * komplikace diagnostické zobrazování terapie MeSH
- fibróza MeSH
- gadolinium MeSH
- kardiomyopatie * terapie MeSH
- komorová tachykardie * terapie MeSH
- kontrastní látky MeSH
- kvalita života MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- prospektivní studie MeSH
- srdeční resynchronizační terapie * MeSH
- srdeční selhání * MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH