Symmetry index
Dotaz
Zobrazit nápovědu
OBJECTIVE: To evaluate the correlation between symmetry of the craniofacial skeleton and aesthetics of the nose and upper lip in children with complete unilateral cleft lip and palate (CUCLP). MATERIAL AND METHODS: Craniofacial symmetry was evaluated on postero-anterior (PA) cephalograms of 54 children (37 boys and 17 girls; mean age = 11.0 years, SD 1.6) with CUCLP repaired with a one-stage closure (Cleft group). Treated subjects were age- and gender-matched with 54 untreated subjects taken from the University of Michigan Growth Study (Control group). Fourteen coefficients of asymmetry (CAs) were calculated and four angles were measured. Four raters assessed the nasolabial appearance on cropped facial and profile photographs with the 5-grade aesthetic index of Asher-McDade (grade 1 means the most aesthetic and grade 5 the least aesthetical outcome) in the Cleft group only. Independent t-tests were used to evaluate the inter-group differences for CAs. Pearson's correlation coefficients were calculated to examine a relationship between particular components of the aesthetical index and CAs. Multiple regression analyses were carried out to explain the nasolabial aesthetics on the basis of craniofacial symmetry. RESULTS: In the Cleft group, most cephalometric variables demonstrated asymmetry not exceeding 10%. The Cleft and Control groups differed regarding three angular measurements (Se, Ism, and ANS) and 1 CA (Mo-V). Three of the four nasolabial components demonstrated correlation with some cephalometric variables. However, the correlation coefficients were low (range: -0.309 to 0.305). CONCLUSIONS: There is a weak correlation between craniofacial skeletal symmetry and aesthetics of the nose and upper lip in children with CUCLP.
- MeSH
- asymetrie obličeje vrozené MeSH
- dítě MeSH
- estetika * MeSH
- kefalometrie MeSH
- lidé MeSH
- neparametrická statistika MeSH
- nos patologie chirurgie MeSH
- obličejové kosti anatomie a histologie MeSH
- ret patologie chirurgie MeSH
- rozštěp patra patologie chirurgie MeSH
- rozštěp rtu patologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Although a leg length inequality (LLI) has the effect on the performed movement, more complex indices for the evaluation of kinematic variables of postural stability and a symmetry of a muscle activity during standing in subjects with the LLI were never used before. OBJECTIVE: The objective is to present appropriate parameters for an evaluation of kinematic variables of postural stability and muscle activity during standing, i.e. to consider EMG signals, in patients with LLI. METHODS: New indices are offered, such as a sway velocity (i.e. the mCTSIB method) and a modified symmetry index (SI), for a quantitative evaluation of EMG signals. The set of data for evaluating the effect of a heel lift was measured on patients with the LLI and healthy volunteers. RESULTS: Prior to the heel lift application, significant statistic differences were found between the mCTSIB of patients and the CG. These differences were no longer statistically significant after the heel lift was applied. As for the SI, the lowest values were found in the CG, while the greatest values were collected among patients before applying the heel lift. CONCLUSIONS: The results point out the benefits of using the newly applied indices in patients with the LLI. Both methods may become useful tools for the evaluation of the physical state of patients with the LLI in a medical practice.
- MeSH
- biomechanika MeSH
- dospělí MeSH
- kosterní svaly patofyziologie MeSH
- lidé MeSH
- mladý dospělý MeSH
- nestejná délka dolních končetin patofyziologie MeSH
- pata patofyziologie MeSH
- pohyb fyziologie MeSH
- postura těla fyziologie MeSH
- posturální rovnováha fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Príspevok prezentuje kvalitu aktívnej hmoty (netuková hmota, svalová hmota) a segmentálnu distribúciu tekutín v tele ako predpoklad výkonu u vrcholových basketbalistiek, strieborných medailistiek Majstrovstiev sveta 2010. Získané dáta preukázali úroveň netukovej hmoty (60,96±5,35 kg) a svalovej hmoty (57,07±5,0 kg) na úrovni elitných športovcov. Tuková hmota preukázala nižšie percentuálne zastúpenie ako je dostupnou literatúrou prezentované (14,34±2,37 %). Na základe získaných dát nie je možné jednoznačne vyjadriť trend pri zastúpení u jednotlivých hráčskych postov. Segmentálne rozloženie tekutín preukázalo asymetriu v prospech dominantnej končatiny pri horných končatinách (p <0,01), čo indikuje nevyhnutnosť realizácie cvičení pre kompenzáciu zisteného bilaterálneho deficitu. V závere autori diskutujú o potrebe kontinuálneho sledovania zmien kvality telesného zloženia v zmysle pozorovania jednotlivých zložiek vody resp. priamo a nepriamo merateľných parametrov pri bioimpedančnom meraní.
The article presents active mass quality (fat free mass, muscle mass) and segmental distribution of body fluids as a prerequisite of performance in elite female basketball players, silvermedallists at 2010 World Championship. The collected data indicated the level of fat free mass (60.96±5.35 kg) and muscle mass (57.07±5.0 kg) at the level of elite athletes. Fat mass showed lower percentage proportion than it is presented by available literature (14.34±2.37 %). Based on the gained data, it is not possible to definitely express a trend in proportion for individual playing positions. Segmental distribution of body fluids revealed a symmetry in favour of a dominant upper limb (p < 0.01), whichindicatetheneed to perform exercises in order to compensate the detected bilateral deficit. In conclusion, the authors discuss the necessity of continual monitoring changes in body composition quality in terms of monitoring individual components of water or directly and indirectly measurable parameters in bioimpedance measurement, respectively.
- MeSH
- antropometrie metody MeSH
- basketbal MeSH
- distribuce tělesného tuku * metody MeSH
- dospělí MeSH
- index tělesné hmotnosti MeSH
- intracelulární tekutina * fyziologie MeSH
- lidé MeSH
- složení těla * fyziologie MeSH
- tělesná konstituce * fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- práce podpořená grantem MeSH
In patients who are prone to impaired swallowing, dysphagia screening has been advocated. However, most dysphagia screening tests are lacking gold-standard validation and nurse screeners. The purpose of this study was to develop a nursing dysphagia screening test to determine the penetration or aspiration risk in patients with neurological and ear, nose, and throat conditions. Eighty-seven Czech patients underwent a bedside assessment by nurse screeners. A comparison of the results to the gold standard, flexible endoscopic examination of swallowing, identified eight "important" or "marginal" assessment items, which were combined into one test, called the Brief Bedside Dysphagia Screening Test: "ability to clench the teeth"; "symmetry/strength of the tongue"; "symmetry/strength of the facial muscles"; "symmetry/strength of the shoulder shrug"; "dysarthria"; "thick liquid: choking"; "thick liquid: dripping from the mouth"; and "thick liquid: cough". The sensitivity, specificity, and negative predictive value of the Brief Bedside Dysphagia Screening Test were: 87.1%, 30.4%, and 81%, respectively, in all patients; 95.2%, 27.5%, and 93.3%, respectively, in patients with neurological conditions; and 60%, 60%, and 42.9%, respectively, in patients with ear, nose, and throat conditions. The test is more suitable for patients with neurological conditions than for more heterogeneous patient populations.
- MeSH
- audiovizuální záznam přístrojové vybavení MeSH
- fluoroskopie přístrojové vybavení metody MeSH
- hodnocení rizik metody MeSH
- interval spolehlivosti MeSH
- lidé MeSH
- polykání MeSH
- poruchy polykání diagnóza ošetřování MeSH
- prediktivní hodnota testů MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- ukazatele zdravotního stavu MeSH
- vyšetření u lůžka MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
- validační studie MeSH
- Geografické názvy
- Česká republika MeSH
... SYMMETRY -- 4.1. Introduction 71 -- 4.2. Symmetry Elements 71 -- 4.3. Symmetry Operators. ... ... Symmetry Point Groups 74 -- Contents vii d. Density and Racemate Type 165 e. Melting Point 167 f. ... ... Boiling Point, Refractive Index, and Density 638 d. Infrared Spectra 639 e. ... ... Symmetry-Based Methods 669 c. Methods Based on Physical and Chemical Properties 671 d. ... ... Cyclostereoisomerism 1176 References 1181 -- GLOSSARY -- 1119 -- 1191 -- INDEX -- 1211 ...
1267 s.
Úvod: Epicondylitis humeri je závažným posudkovým problémem, kde uznanou příčinou vzniku nemoci musí být pracovní podmínky. Diagnóza je stanovena na základě subjektivních údajů pacienta, ortopedických vyšetření a zobrazovacích metod. Kvantitativní třífázová scintigrafie loktů umožňuje objektivizovat diagnostiku metabolických změn v kostní tkáni na subcelulární úrovni. Soubor a metodika:47 jedinců průměrného věku 55 let (26 žen (31–60 let), 21 mužů (26–64 let)) s bolestmi loktů. Třífázová scintigrafie cílená na oblast loktů byla provedena vsedě s horními končetinami na kolimátoru v supinační paralelní poloze s označením oblastí epikondylů humeru obou končetin. 10 MBq/kg 99mTc-HDP bylo aplikováno do povrchových žil dorsa pedis. Hodnocení bylo provedeno vizuálně z hlediska symetrie krevního zásobení, u 2. a 3. fáze i kvantitativně s výpočtem indexů (podíl počtu impulsů/pixel z oblastí zájmu radiálního, ulnárního epikondylu obou horních končetin k průměrné hodnotě impulsů/pixel pravého a levého předloktí (referenční oblast) a souhrnným indexem (součin indexů 2. a 3. fáze), označeného jako index lokální metabolické aktivity (ILMA). Hodnocení dvěma hodnotiteli se uskutečnilo nezávisle. Výsledky: Průměrné hodnoty ILMA u 19 jedinců se scintigrafickým nálezem negativním činil Dxrad 1,7 ± 0,4; Dxuln 1,8 ± 0,5; Sinrad 1,4 ± 0,3; Sinuln 1,9 ± 0,4; u 28 jedinců s nálezem pozitivním Dxrad 4,5 ± 1,6; Dxuln 4,0 ± 1,1; Sinrad 4,4 ± 1,1; Sinuln 4,4 ± 1,5. Dosud u 3 pacientů byla uznána NzP s hodnotami ILMA: 1. Sinrad 5,1; 2. Sinrad 3,9; 3. Dxrad 4,7. V rámci intraindividuálního šetření rozdíl hodnot indexů u opakovaného vyšetření č-nil 0–0,9; interpersonální variabilita byla v rozmezí 0–1,2.Závěr: Metoda kvantitativní třífázové scintigrafie loktů umožňuje objektivizovat metabolické změny v oblasti epikondylů při posuzování nemoci z povolání.
Introduction: Epicondylitis humeri is a serious problem as a professional disease, where working conditions are a recognized cause of illness. The diagnosis is based on subjective patient data, orthopedic examinations and imaging methods. The quantitative three-phase elbow scintigraphy allows for the objective diagnosis of metabolic changes in bone tissue at the subcellular level. Material and methods: 47 individuals with an average age of 55 years (26 women (31-60 years) 21 men (26-64 years)) with elbow pains. Elbow elongated three-phase scintigraphy was performed sitting down with the upper extremities on the collimator in the supine parallel position, marked epicondyles of humerus of both limbs. 10 MBq/kg 99mTc-HDP (hydroxymethylene diphosphonate) was applied to the foot superficial vein. The evaluation was performed visually in terms of blood supply symmetry, phase 2 and 3 as well as quantitatively with index calculations (number of impulses/pixel from areas of interest of radial, ulnar epicondyle of both upper extremities to mean value of impulses/pixel of right and left forearms (reference region) and the aggregate index (multiple of phase 2 and 3 indices), referred to as the Local Metabolic Activity Index (ILMA). The evaluation by the two evaluators took place independently. Results: Mean ILMA values in 19 subjects with negative scintigraphic findings were Dxrad 1.7± 0.4; Dxuln 1.8± 0.5; Sinrad1.4± 0.3; Sinuln 1.9± 0.4; in 28 subjects with positive findings Dxrad 4.5± 1.6; Dxuln 4.0± 1.1; Sinrad 4.4± 1.1; Sinuln 4.4± 1.5. So far, 3 patients have been recognized occupational disease with ILMA values: 1. Sinrad 5.1; 2. Sinrad 3.9; 3. Dxrad 4.7. In the intraindividual investigation the difference between the indices of the re-examination was 0-0,9; interpersonal variability ranged from 0-1,2. Conclusion: The method of quantitative three-phase elbow scintigraphy enables to objectify metabolic changes in the area of epicondyles in the assessment of occupational disease.
- Klíčová slova
- kvantitativní třífázová scintigrafie loktů,
- MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- loket diagnostické zobrazování MeSH
- nemoci z povolání MeSH
- radioisotopová scintigrafie * metody MeSH
- retrospektivní studie MeSH
- senioři MeSH
- zánět šlach lokte * diagnostické zobrazování MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
Nowadays, bipedal walking is undergoing extensive study. Several methods can be used in physiotherapeutic research for identifying defects in bipedal walking as a result of pathology of the musculoskeletal or nervous system. Our work focuses on studying asymmetry of walking based on synchronized bilateral knee-knee cyclograms. Participants presenting with peroneal nerve palsy and foot drop were included in the study. The bilateral cyclograms, also called angle-angle diagrams, were created to quantify gait asymmetry before and immediately after application of a brace. In order to quantify the asymmetry of human walking, we have described and tested the application of the method based on the inclination angle of the synchronized bilateral cyclograms. The symmetry index (SI) was used as a comparative method to evaluate the symmetry of bipedal walking. The method based on the orientation of the cyclograms can be used as an additional method for determining the gait asymmetry. The new technique has never been applied before to study the gait asymmetry in patients with peroneal nerve palsy or patients with leg brace.
- MeSH
- algoritmy MeSH
- biomechanika * MeSH
- chůze (způsob) fyziologie MeSH
- dospělí MeSH
- koleno patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- neuropatie nervus peroneus patofyziologie MeSH
- paralýza MeSH
- potraviny MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
... Bivariate Discrete Distributions 264 -- 7.2 Square Tables 270 -- 7.2.1 Quasi-Independence 270 -- 7.2.2 Symmetry ... ... 270 -- 7.2.3 Quasi-Symmetry 273 -- 7.2.4 Tables with Ordered Categories 276 -- 7.2.5 Matched Pairs Data ... ... Background Material 448 -- 10.4 Exercises 449 -- A Some Basics of Matrix Algebra 455 -- References 459 -- Index ...
Springer texts in statistics
1st ed. xiii, 496 s.
Úvod: Epicondylitis humeri je častým onemocněním u běžných činností s nedostatečnou adaptací tkání na fyzickou zátěž. Závažným posudkovým problémem je profesionální onemocnění, kde uznanou příčinou vzniku nemoci musí být pracovní podmínky. Diagnóza je stanovena na základě subjektivních údajů pacienta, ortopedických vyšetření a zobrazovacích metod. Objektivizaci diagnostiky metabolických změn v kostní tkáni na subcelulární úrovni umožňuje kvantitativní třífázová scintigrafie loktů. Soubor a metodika: 47 jedinců průměrného věku 55 let (26 žen (31–60 let), 21 mužů (26–64 let)) s bolestmi loktů. Pracovní expozice v době vyšetření byla u žen 1–13, u mužů v rozmezí 1–18 let, pracovní neschopnost u žen 3–12, u mužů 0–12 měsíců. Třífázová scintigrafie cílená na oblast loktů byla provedena vsedě s horními končetinami na kolimátoru v supinační paralelní poloze s označením oblastí epikondylů humeru obou končetin. 10 MBq/kg 99mTc-HDP bylo aplikováno do povrchových žil dorsa pedis. Hodnocení bylo provedeno vizuálně z hlediska symetrie krevního zásobení, u 2. a 3. fáze i kvantitativně s výpočtem indexů (podíl počtu impulsů/pixel z oblastí zájmu radiálního, ulnárního epikondylu obou horních končetin k průměrné hodnotě impulsů/pixel pravého a levého předloktí (referenční oblast) a souhrnným indexem (součin indexů 2. a 3. fáze), označeného jako index lokální metabolické aktivity (ILMA). Hodnocení dvěma hodnotiteli proběhlo nezávisle. Výsledky: Průměrné hodnoty ILMA u 19 jedinců se scintigrafickým nálezem negativním činil Dxrad 1,7 ± 0,4; Dxuln 1,8 ± 0,5; Sinrad 1,4 ± 0,3; Sinuln 1,9 ± 0,4; u 28 jedinců s nálezem pozitivním Dxrad 4,5 ± 1,6; Dxuln 4,0 ± 1,1; Sinrad 4,4 ± 1,1; Sinuln 4,4 ± 1,5. Dosud u 3 pacientů byla uznána NzP s hodnotami ILMA: 1. Sinrad 5,1; 2. Sinrad 3,9; 3. Dxrad 4,7. V průběhu intraindividuálního šetření rozdíl hodnot indexů u opakovaného vyšetření činil 0–0,9; interpersonální variabilita byla v rozmezí 0–1,2. Závěr: Kvantitativní třífázová scintigrafie loktů je pomocnou metodou k objektivizaci metabolických změn při posuzování nemoci z povolání u chronické epikondylitidy.
Introduction: Epicondylitis humeri is a common disease in activities with insufficient adaptation of tissues to physical stress. Aim of this study is to help assess it as a professional disease, where working conditions must be a recognized cause of the disease. The diagnosis is based on symptoms of the patient, orthopedic examinations and imaging methods. The quantitative three-phase bone scintigraphy of the elbows allows for the objective diagnosis of metabolic changes in bone tissue at the subcellular level. Material and Methods: 47 individuals with an average age of 55 years (26 women (31-60 years) 21 men (26-64 years)) with elbow pains. Elbow three-phase bone scintigraphy was performed with patients sitting down with their upper extremities on the collimator in the supine parallel position, marked epicondyles of humerus of both limbs. 10 MBq/kg 99mTc-HDP (hydroxymethylene diphosphonate) was applied to the foot superficial vein. Visual evaluation of the blood supply symmetry (phase 1.), blood pool (phase 2.) and bone accumulation (phase 3.), was performed. In addition quantification of the phase 2. and phase 3. was performed using index calculations (number of impulses/pixel from areas of interest of radial, ulnar epicondyle of both upper extremities to mean value of impulses/pixel of right and left forearms (reference region) and the aggregate index (multiple of phase 2 and 3 indices), refer-red to as the Local Metabolic Activity Index (ILMA). The evaluation by the two evaluators took place independently. Results: Mean ILMA values in 19 subjects with negative scintigraphic findings were Dxrad 1.7 ± 0.4; Dxuln 1.8 ± 0.5; Sinrad 1.4 ± 0.3; Sinuln 1.9 ± 0.4; in 28 subjects with positive findings Dxrad 4.5 ± 1.6; Dxuln 4.0 ± 1.1; Sinrad 4.4 ± 1.1; Sinuln 4.4 ± 1.5. So far, 3 patients have been recognized occupational disease with ILMA values: 1. Sinrad 5.1; 2. Sinrad 3.9; 3. Dxrad 4.7. In the intraindividual investigation the difference between the indices of the re-examination was 0-0,9; interpersonal variability ranged from 0-1,2. Conclusion: The method of quantitative three-phase elbow scintigraphy enables to objectify metabolic changes in the area of epicondyles in the assessment of occupational disease.
- Klíčová slova
- kvantitativní třífázová scintigrafie loktů,
- MeSH
- dospělí MeSH
- entezopatie diagnóza MeSH
- klinická studie jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- loket diagnostické zobrazování MeSH
- nemoci z povolání MeSH
- radioisotopová scintigrafie metody MeSH
- senioři MeSH
- tenisový loket * diagnóza MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
Refractometric sensors utilizing surface plasmon resonance (SPR) should satisfy a series of performance metrics, bulk sensitivity, thin-film sensitivity, refractive-index resolution, and high-Q-factor resonance, as well as practical requirements such as manufacturability and the ability to separate optical and fluidic paths via reflection-mode sensing. While many geometries such as nanohole, nanoslit, and nanoparticles have been employed, it is nontrivial to engineer nanostructures to satisfy all of the aforementioned requirements. We combine gold nanohole arrays with a water-index-matched Cytop film to demonstrate reflection-mode, high-Q-factor (Qexp = 143) symmetric plasmonic sensor architecture. Using template stripping with a Cytop film, we can replicate a large number of index-symmetric nanohole arrays, which support sharp plasmonic resonances that can be probed by light reflected from their backside with a high extinction amplitude. The reflection geometry separates the optical and microfluidic paths without sacrificing sensor performance as is the case of standard (index-asymmetric) nanohole arrays. Furthermore, plasmon hybridization caused by the array refractive-index symmetry enables dual-mode detection that allows distinction of refractive-index changes occurring at different distances from the surface, making it possible to identify SPR response from differently sized particles or to distinguish binding events near the surface from bulk index changes. Due to the unique combination of a dual-mode reflection-configuration sensing, high-Q plasmonic modes, and template-stripping nanofabrication, this platform can extend the utility of nanohole SPR for sensing applications involving biomolecules, polymers, nanovesicles, and biomembranes.
- MeSH
- biosenzitivní techniky metody MeSH
- fosfatidylcholiny chemie MeSH
- limita detekce MeSH
- liposomy analýza chemie MeSH
- nanopóry * MeSH
- oxid hlinitý chemie MeSH
- povrchová plasmonová rezonance metody MeSH
- sérový albumin hovězí analýza MeSH
- skot MeSH
- zlato chemie MeSH
- zvířata MeSH
- Check Tag
- skot MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, U.S. Gov't, Non-P.H.S. MeSH