optical gap
Dotaz
Zobrazit nápovědu
PURPOSE: To assess the intraday repeatability of macular architecture measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography (SD-OCT) and to evaluate the independence from intraindividual intraocular pressure (IOP) fluctuations. METHODS: In this single-center, time-point comparison study, 88 eyes with glaucoma, 53 eyes with ocular hypertension (OHT), and 253 healthy eyes underwent two standardized SD-OCT and intraocular pressure (IOP) measurements on the same day with a 5-h time gap. Bland-Altman plots, intraclass correlation coefficients (ICC), and random-effects model were used to analyze repeatability of entire retinal thickness, retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, and inner nuclear layer measurements. RESULTS: Intraday measurements were highly reproducible in all 3 groups. ICC were greater than 0.90, respectively. The pairwise comparisons of morphometric parameters showed a statistically significant difference (P < 0.001, respectively) between groups (glaucoma vs. control, glaucoma vs. OHT) and a significant influence of time points. No correlation was found between IOP fluctuations and morphometric parameters (P > 0.05, respectively), except for a weak positive correlation with GCL (rho = 0.109, P = 0.031). CONCLUSIONS: The evaluation of macular morphometric parameters of SD-OCT showed a high intraday repeatability and an excellent degree of agreement in glaucoma, ocular hypertension, and healthy groups. The fixed effects of time points were statistically significant. Except for a weak positive correlation of ganglion cell layer, variability did not appear to be affected by intraday IOP changes. Additional research is required to fully understand the impact of IOP fluctuations on macular morphometric parameters, considering the small observed IOP changes.
- MeSH
- dospělí MeSH
- glaukom * diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- macula lutea * patologie diagnostické zobrazování MeSH
- následné studie MeSH
- nervová vlákna * patologie MeSH
- nitrooční tlak * fyziologie MeSH
- oční hypertenze diagnóza patofyziologie MeSH
- optická koherentní tomografie * metody MeSH
- reprodukovatelnost výsledků MeSH
- retinální gangliové buňky * patologie MeSH
- senioři MeSH
- tonometrie oční MeSH
- zraková pole fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
Leaf area index (LAI) is an essential canopy variable describing the amount of foliage in an ecosystem. The parameter serves as the interface between green components of plants and the atmosphere, and many physiological processes occur there, primarily photosynthetic uptake, respiration, and transpiration. LAI is also an input parameter for many models involving carbon, water, and the energy cycle. Moreover, ground-based in situ measurements serve as the calibration method for LAI obtained from remote sensing products. Therefore, straightforward indirect optical methods are necessary for making precise and rapid LAI estimates. The methodological approach, advantages, controversies, and future perspectives of the newly developed LP 110 optical device based on the relation between radiation transmitted through the vegetation canopy and canopy gaps were discussed in the protocol. Furthermore, the instrument was compared to the world standard LAI-2200 Plant Canopy Analyzer. The LP 110 enables more rapid and more straightforward processing of data acquired in the field, and it is more affordable than the Plant Canopy Analyzer. The new instrument is characterized by its ease of use for both above- and below-canopy readings due to its greater sensor sensitivity, in-built digital inclinometer, and automatic logging of readings at the correct position. Therefore, the hand-held LP 110 device is a suitable gadget for performing LAI estimation in forestry, ecology, horticulture, and agriculture based on the representative results. Moreover, the same device also enables the user to take accurate measurements of incident photosynthetically active radiation (PAR) intensity.
INTRODUCTION: Remodeling of human placental membranes (amniochorionic or fetalmembrane) throughout gestation, a necessity to accommodate increasing uterine volume, involves continuous alterations (replacement of cells and remodeling of extracellular matrix). Methodologic limitations have obscured microscopic determination of cellular and layer-level alterations. This study used a combination of advanced imaging by multiphoton autofluorescence microscopy (MPAM) and second harmonic generation (SHG) microscopy along with tissue optical clearing to characterize the 3Dimensional multilayer organization of placental membranes. METHODS: Placental membranes biopsies (6 mm) collected from term, not-in-labor cesarean deliveries (n = 7) were fixed in 10% formalin (native) or treated with 2,2'-thiodiethanol to render them transparent for deeper imaging. Native and cleared tissues were imaged using MPAM (cellular autofluorescence) and SHG (fibrillar collagen). Depth z-stacks captured the amnion epithelium, underlying matrix layers, and in the cleared biopsies, the decidua layer. RESULTS: MPAM and SHG revealed fetal membrane epithelial topography and collagen organization in multiple matrix layers. Term amnion layers showed epithelial shedding and gaps. Optical clearing provided full-depth imaging with improved visualization of collagen structure, mesenchymal cells in extracellular matrix layers, and decidua morphology. Layer thicknesses measured by imaging corroborated with histology. Mosaic tiling of MPAM/SHG image stacks allowed large area visualization of entire biopsies. CONCLUSION: MPAM-SHG microscopy allowed for study of this multi-layered tissue and revealed shedding, gap formation, and other structural changes. This approach could be used to study structural changes associated with membranes as well as other uterine tissues to better understand events in normal and abnormal parturition.
- MeSH
- extracelulární matrix MeSH
- extraembryonální obaly anatomie a histologie diagnostické zobrazování MeSH
- histocytologické preparační techniky MeSH
- lidé MeSH
- mikroskopie fluorescenční multifotonová * MeSH
- mikroskopie generování druhé harmonické * MeSH
- placenta anatomie a histologie diagnostické zobrazování MeSH
- těhotenství MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
[1st ed.] xii, 300 s., il.
AIMS: The aim of this study was to characterize ventricular activation patterns in normal and connexin40-deficient mice in order to dissect the role of connexin40 in developing the conduction system. METHODS AND RESULTS: We performed optical mapping of epicardial activation between ED9.5-18.5 and analysed ventricular activation patterns and times of left ventricular activation. Mouse embryos deficient for connexin40 were compared with normal and heterozygous littermates. Morphology of the primary interventricular ring (PIR) was delineated with the help of T3-LacZ transgene. Four major types of ventricular activation patterns characterized by primary breakthrough in different parts of the heart were detected during development: PIR, left ventricular apex, right ventricular apex, and dual right and left ventricular apices. Activation through PIR was frequently present at the early stages until ED12.5. From ED14.5, the majority of hearts showed dual left and right apical breakthrough, suggesting functionality of both bundle branches. Connexin40-deficient embryos showed initially a delay in left bundle branch function, but the right bundle branch block, previously described in the adults, was not detected in ED14.5 embryos and appeared only gradually with 80% penetrance at ED18.5. CONCLUSION: The switch of function from the early PIR conduction pathway to the mature apex to base activation is dependent upon upregulation of connexin40 expression in the ventricular trabeculae. The early function of right bundle branch does not depend on connexin40. Quantitative analysis of normal mouse embryonic ventricular conduction patterns will be useful for interpretation of effects of mutations affecting the function of the cardiac conduction system.
- MeSH
- akční potenciály MeSH
- blokáda Tawarova raménka genetika metabolismus MeSH
- gestační stáří MeSH
- Hisův svazek embryologie metabolismus MeSH
- konexiny nedostatek genetika MeSH
- lac operon MeSH
- morfogeneze MeSH
- myši knockoutované MeSH
- myši transgenní MeSH
- myši MeSH
- penetrance MeSH
- převodní systém srdeční embryologie metabolismus MeSH
- srdeční komory embryologie metabolismus MeSH
- vývojová regulace genové exprese MeSH
- zobrazování pomocí barviva citlivého na potenciál MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In this study, we delve into the electronic structure, spectroscopic, and optical properties of five benzo derivatives of pyridine, namely, 5-(4-chlorophenyl)-2-fluoropyridine (1), 2-fluoro-5-(4-fluorophenyl)pyridine (2), 4-(2-fluoropyridin-5-yl)phenol (3), 5-(2,3-dichlorophenyl)-2-fluoropyridine (4), and 5-(5-bromo-2-methoxyphenyl)-2-fluoropyridine (5). Utilizing quantum chemical density functional theory calculations at the B3LYP and Perdew-Burke-Ernzerhof levels of theory combined with the 6-311G(d,p) and 6-311++G(d,p) basis sets, we investigated the electronic and optical characteristics of these compounds. Band structure calculations were conducted for their crystalline structures, revealing a direct band gap varying from 3.018 to 3.558 eV, with the valence band maximum and conduction band minimum located at the G point in the Brillouin zone. The optical properties were analyzed, including the dielectric functions, reflectivity, and refractive index. Notably, reflectivity was found to be minimal in the photon energy range of 0.0-3.0 eV, and the static refractive index, n(0), ranged from 1.55 to 1.70. The research also involved assessing the reactivity of the compounds through calculation of the frontier orbital energy gaps (ΔE), indicating a significant charge transfer and high reactivity. Additionally, we performed frequency analysis to unveil the Fourier-transform infrared spectra of compounds 1-5 at room temperature. Molecular electrostatic potential surfaces of the optimized structures were employed to map the electrophilic and nucleophilic regions of the compounds. This investigation provides a comprehensive understanding of the electronic and optical properties of these pyridine derivatives, shedding light on their potential applications in optoelectronics.
- Publikační typ
- časopisecké články MeSH
The distribution of fluorescence signals measured with flow cytometry can be influenced by several factors, including qualitative and quantitative properties of the used fluorochromes, optical properties of the detection system, as well as the variability within the analyzed cell population itself. Most of the single cell samples prepared from in vitrocultures or clinical specimens contain a variable cell cycle component. Cell cycle, together with changes in the cell size, are two of the factors that alter the functional properties of analyzed cells and thus affect the interpretation of obtained results. Here, we describe the association between cell cycle status and cell size, and the variability in the distribution of fluorescence intensity as determined with flow cytometry, at population scale. We show that variability in the distribution of background and specific fluorescence signals is related to the cell cycle state of the selected population, with the 10% low fluorescence signal fraction enriched mainly in cells in their G0/G1 cell cycle phase, and the 10% high fraction containing cells mostly in the G2/M phase. Therefore we advise using caution and additional experimental validation when comparing populations defined by fractions at both ends of fluorescence signal distribution to avoid biases caused by the effect of cell cycle and cell size.
- MeSH
- buněčné dělení MeSH
- buněčný cyklus fyziologie MeSH
- G2 fáze * MeSH
- průtoková cytometrie metody MeSH
- velikost buňky MeSH
- Publikační typ
- časopisecké články MeSH
- MeSH
- acidobazická rovnováha fyziologie účinky léků MeSH
- anamnéza MeSH
- diagnostické techniky porodnicko-gynekologické klasifikace MeSH
- farmakoterapie metody MeSH
- kandidóza vulvovaginální * diagnóza farmakoterapie terapie MeSH
- kritické cesty MeSH
- kultivační techniky metody MeSH
- lidé MeSH
- mikroskopie metody MeSH
- molekulární biologie metody MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
Methods: The cohort included 65 clear corneal incisions of 49 patients who underwent cataract surgery. Corneal incisions were recorded using a Leica Proveo 8 microscope with an intraoperative OCT EnFocus™ device continuously during the surgery. Corneal incision morphology before and after lateral stromal hydration was analysed. Results: Good adaptation of the corneal incision before hydration was present in 39 cases (60%), in 16 cases (24.6%), the prominence of posterior lip was present, and, in 10 cases (15.4%), the posterior lip tongue was inverted/retracted into the incision. In 38 cases (58.5%), hydration had no effect on the incision architecture; most often, it was primarily a well-adapted corneal incision (46.2%), less often an incision with posterior lip prominence (10.8%), or tongue inversion into the incision (1.6%) prior to hydration. Hydration worsened the incision architecture in 14 cases (21.5%); most often, it induced/worsened posterior lip prominence (15.4%), less often posterior lip retraction (1.6%), tongue inversion into the incision (1.6%), gap development in the peripheral part of the corneal incision (1.6%), or incomplete opening of the corneal incision (1.6%). In 13 cases (20%), hydration improved the incision architecture, especially in cases with inverted or retracted posterior lip tongue (12.3%), less often in cases with posterior lip prominence (7.7%). Conclusion: Lateral stromal hydration seldom affects the condition of the corneal incision. Still, it can cause both deterioration and improvement of the corneal incision architecture. Intraoperative OCT provides real-time monitoring of corneal incision morphology during hydration procedure.
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: Neurofibromatosis von Recklinghausen type 1 (NF1) is an autosomal dominant neurocutaneous disorder affecting one in 3 000-4 000 individuals. Mid-aortic syndrome (MAS) is a rare condition characterized by segmental narrowing of abdominal aorta and stenosis of its major branches - mainly renal arteries, including manifestation of renovascular hypertension. MAS can be caused by different diseases, including NF1. MAIN FINDINGS: A 9 years old girl with primary diagnosis of NF1 combined with renovascular hypertension due to MAS, suffered of bilateral optic and chiasm glioma, pubertas praecox, speech disorder, light mental retardation and scoliosis. We have found a mutation in exone 34 of the NF1 gene (17q11.2). Her father has been also diagnosed with NF1 and hypertension developed at early age. He has the same mutation in exone 34 of NF1 gene. The girl is currently treated with conservative antihypertensive medication with positive effect. Bilateral optic and chiasm glioma are asymptomatic at the time and they had been without progress over period of time. Any vascular surgery, neurosurgical and oncological therapy are not indicated at the present time. CONCLUSION: This article is a summary of clinical findings in patient with NF1 due to NF1 gene mutation in exone 34. It confirms the importance of complex multidisciplinar approach to examination and taking care of NF1 patients and their families.
- MeSH
- aorta abdominalis abnormality patologie MeSH
- arteria renalis patologie MeSH
- chiasma opticum patologie MeSH
- dítě MeSH
- financování organizované MeSH
- gliom genetika komplikace patologie MeSH
- hypertrofie levé komory srdeční genetika komplikace MeSH
- lidé MeSH
- messenger RNA metabolismus MeSH
- mutace MeSH
- nádory zrakového nervu genetika komplikace patologie MeSH
- nemoci aorty genetika komplikace patologie MeSH
- neurofibromatóza 1 MeSH
- neurofibromin 1 genetika metabolismus MeSH
- předškolní dítě MeSH
- proteosyntéza MeSH
- renovaskulární hypertenze genetika komplikace patologie MeSH
- stenóza MeSH
- syndrom MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH