AIMS: Cardiac resynchronization therapy (CRT) is guideline recommended for the treatment of symptomatic heart failure (HF) with reduced left ventricular ejection fraction and prolonged QRS. However, patients with common comorbidities, such as persistent/permanent atrial fibrillation (AF), are often under-represented in clinical trials. METHODS: The Strategic Management to Optimize Response to Cardiac Resynchronization Therapy (SMART) registry (NCT03075215) was a global, multicentre, registry that enrolled de novo CRT implants, or upgrade from pacemaker or implantable cardioverter defibrillator to CRT-defibrillator (CRT-D), using a quadripolar left ventricular lead in real-world clinical practice. The primary endpoint was CRT response between baseline and 12 month follow-up defined as a clinical composite score (CCS) consisting of all-cause mortality, HF-associated hospitalization, New York Heart Association (NYHA) class and quality of life global assessment. RESULTS: The registry enrolled 2035 patients, of which 1558 had completed CCS outcomes at 12 months. The patient cohort was 33.0% female, mean age at enrolment was 67.5 ± 10.4 years and the mean left ventricular ejection fraction was 29.6 ± 7.9%. Notably, there was a high prevalence of mildly symptomatic patients (NYHA class I/II 51.3%), non-left bundle branch block (LBBB) morphology (38.0%), AF (37.2%) and diabetes mellitus (34.7%) at baseline. CCS at 12 months improved in 58.9% (n = 917) of patients; 20.1% (n = 313) of patients stabilized and 21.0% (n = 328) worsened. Several patient characteristics were associated with a lower likelihood of response to CRT including older age, ischaemic aetiology, renal dysfunction, AF, non-LBBB morphology and diabetes. Higher HF hospitalization (P < 0.001) and all-cause mortality (P < 0.001) were observed in patients with AF. These patients also had lower percentages of ventricular pacing than patients in sinus rhythm at baseline and follow-up (P < 0.001, both). A further association between AF and non-LBBB was observed with 81.4% of AF non-LBBB patients experiencing an HF hospitalization compared with 92.5% of non-AF LBBB patients (P < 0.001). Mortality between subgroups was also statistically significant (P = 0.019). CONCLUSIONS: This large, global registry enrolled a CRT-D population with higher incidence of comorbidities that have been historically underrepresented in clinical trials and provides new insight into factors influencing response to CRT. As defined by CCS, 58.9% of patients improved and 20.1% stabilized. Patients with AF had particularly worse clinical outcomes, higher HF hospitalization and mortality rates and lower percentages of ventricular pacing. High incidence of HF hospitalization in patients with AF and non-LBBB in this real-world cohort suggests that ablation may play an important role in increasing future CRT response rates.
- MeSH
- celosvětové zdraví MeSH
- funkce levé komory srdeční * fyziologie MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- registrace * MeSH
- senioři MeSH
- srdeční resynchronizační terapie * metody MeSH
- srdeční selhání * terapie patofyziologie mortalita MeSH
- tepový objem * fyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: Cardiac resynchronization therapy (CRT) is a guideline-recommended therapy in patients with heart failure with mildly reduced ejection fraction (HFmrEF, 36%-50%) and left bundle branch block or indication for ventricular pacing. Conduction system pacing (CSP) using left bundle branch area pacing or His bundle pacing has been shown to be a safe and physiologic alternative to biventricular pacing (BVP). OBJECTIVE: The aim of this study was to compare the clinical outcomes between BVP and CSP for patients with HFmrEF undergoing CRT. METHODS: Consecutive patients who underwent BVP or CSP with HFmrEF between January 2018 and June 2023 at 16 international centers were included. The primary outcome was the composite end point of time to death or heart failure hospitalization (HFH). Secondary end points included change in left ventricular ejection fraction (LVEF) and individual end points of death and HFH. RESULTS: A total of 1004 patients met inclusion criteria: BVP, 178; CSP, 826 (His bundle pacing, 154; left bundle branch area pacing, 672). Mean age was 73 ± 13 years; female, 34%; and LVEF, 42% ± 5%. Paced QRS duration in CSP was significantly narrower compared with BVP (129 ± 21 ms vs 144 ± 19 ms; P < .001). LVEF improved during follow-up in both groups (49% ± 10% vs 48% ± 10%; P = .32). CSP was independently associated with significant reduction in the primary end point of time to death or HFH compared with BVP (22% vs 34%; hazard ratio, 0.64; 95% confidence interval, 0.43-0.94; P = .025). CONCLUSION: CSP was associated with improved clinical outcomes compared with BVP in this large cohort of patients with HFmrEF undergoing CRT. Randomized controlled trials comparing CSP with BVP will be necessary to confirm these results.
- MeSH
- blokáda Tawarova raménka terapie patofyziologie MeSH
- funkce levé komory srdeční * fyziologie MeSH
- Hisův svazek patofyziologie MeSH
- lidé MeSH
- následné studie MeSH
- převodní systém srdeční * patofyziologie MeSH
- retrospektivní studie MeSH
- senioři MeSH
- srdeční resynchronizační terapie * metody MeSH
- srdeční selhání * terapie patofyziologie MeSH
- studie případů a kontrol MeSH
- tepový objem * fyziologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- srovnávací studie MeSH
BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has been associated with greater clinical improvement in women than men. Recently, left bundle branch area pacing (LBBAP) has been shown to be an alternative form of CRT. OBJECTIVES: The purpose of this study was to investigate sex-specific outcomes for death and heart failure events in a large, international, multicenter, cohort of patients undergoing CRT with BVP or LBBAP. METHODS: In this international study of 1,778 patients (575 female and 1203 male), sex-specific survival analysis was performed to compare the effect of LBBAP-CRT relative to BVP-CRT on the combined endpoint of death or heart failure hospitalization (HFH), and secondary endpoints of HFH only, and death alone. RESULTS: Female patients were more likely to have nonischemic cardiomyopathy and left bundle branch block (LBBB) and less likely to have hypertension, diabetes, or coronary artery disease than were male patients. Overall, female patients had a better result with LBBAP compared with BVP than did male patients, with a significant 36% reduction in death or HFH (HR: 0.64; 95% CI: 0.43 to 0.97; P = 0.03) and a significant 60% reduction in HFH alone (HR: 0.4; 95% CI: 0.24 to 0.69, P < 0.01). Women had a greater reduction in death or HFH among those with nonischemic cardiomyopathy (HR: 0.45 95% CI: 0.26 to 0.79; P < 0.01) and LBBB (HR: 0.49; 95% CI: 0.27 to 0.87; P < 0.01). Sex-specific echocardiographic outcomes were better in women than in men. CONCLUSIONS: Women obtained significantly greater reductions in the combined endpoint of death or HFH (primarily driven by reduction in HFH) with LBBAP compared with BVP among patients requiring CRT than did men.
BACKGROUND: The effect of left ventricular septal myocardial pacing (LVSP) and left bundle branch pacing (LBBP) on ventricular synchrony and left ventricular (LV) hemodynamic status is poorly understood. OBJECTIVES: The aim of this study was to investigate the impact of LVSP and LBBP vs biventricular pacing (BVP) on ventricular electrical synchrony and hemodynamic status in cardiac resynchronization therapy patients. METHODS: In cardiac resynchronization therapy candidates with LV conduction disease, ventricular synchrony was assessed by measuring QRS duration (QRSd) and using ultra-high-frequency electrocardiography. LV electrical dyssynchrony was assessed as the difference between the first activation in leads V1 to V8 to the last from leads V4 to V8. LV hemodynamic status was estimated using invasive systolic blood pressure measurement during multiple transitions between LBBP, LVSP, and BVP. RESULTS: A total of 35 patients with a mean LV ejection fraction of 29% and a mean QRSd of 168 ± 24 ms were included. Thirteen had ischemic cardiomyopathy. QRSd during BVP, LVSP, and LBBP was the same, but LBBP provided shorter LV electrical dyssynchrony than BVP (-10 ms; 95% CI: -16 to -4 ms; P = 0.001); the difference between LVSP and BVP was not significant (-5 ms; 95% CI: -12 to 1 ms; P = 0.10). LBBP was associated with higher systolic blood pressure than BVP (4%; 95% CI: 2%-5%; P < 0.001), whereas LVSP was not (1%; 95% CI: 0%-2%; P = 0.10). Hemodynamic differences during LBBP and LVSP vs BVP were more pronounced in nonischemic than ischemic patients. CONCLUSIONS: Ultra-high-frequency electrocardiography allowed the documentation of differences in LV synchrony between LBBP, LVSP, and BVP, which were not observed by measuring QRSd. LVSP provided the same LV synchrony and hemodynamic status as BVP, while LBBP was better than BVP in both.
- MeSH
- dysfunkce levé srdeční komory patofyziologie terapie MeSH
- elektrokardiografie * MeSH
- funkce levé komory srdeční fyziologie MeSH
- hemodynamika * fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mezikomorová přepážka patofyziologie MeSH
- senioři MeSH
- srdeční resynchronizační terapie * metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: Biventricular pacing (BVP) from multiple left ventricular (LV) sites could enhance the efficacy of cardiac resynchronization therapy (CRT) by engaging a greater myocardial mass. OBJECTIVES: The goal of this study was to evaluate the acute hemodynamic effect of various multisite pacing (MSP) configurations against conventional BVP. METHODS: Twenty patients with nonischemic dilated cardiomyopathy and left bundle branch block (mean age: 59 ± 14 years; LV ejection fraction: 27% ± 6%; native QRS: 171 ± 16 milliseconds) were investigated during a routine CRT implant procedure. In addition to conventional right atrial and right ventricular leads, 2 quadripolar leads were placed in the distant coronary venous branches. LV hemodynamics was evaluated by using a micromanometer-tipped catheter during atrioventricular BVP with 4 LV lead configurations: single-lead conventional BVP; single-lead multipoint pacing; triventricular pacing from distal dipoles of 2 LV leads; and maximum MSP (MSP-Max) from 4 dipoles of 2 LV leads. RESULTS: Compared with right atrial pacing, any BVP configuration produced a significant increase in the maximal LV diastolic pressure rise (LVdP/dTMax) (a median relative increase of 28% [IQR: 8%-45%], 25% [IQR: 18%-46%], 36% [IQR: 18%-54%], and 38% [IQR: 28%-58%], respectively; all, P < 0.001). MSP-Max but no other multisite BVP generated a significant increase of the maximal LVdP/dTMax than conventional BVP (P = 0.041). Increased LVdP/dTMax during MSP-Max was associated with greater LV diameter and lower LV ejection fraction, independently of the QRS width. CONCLUSIONS: The study shows the hemodynamic advantage of a novel dual-vein MSP-Max configuration that could be useful for CRT in patients with advanced LV remodeling.
- MeSH
- blokáda Tawarova raménka komplikace terapie MeSH
- defibrilátory implantabilní MeSH
- elektrokardiografie metody MeSH
- fibrilace síní terapie MeSH
- infekce spojené se zdravotní péčí etiologie MeSH
- kardiostimulátor MeSH
- lidé MeSH
- srdeční resynchronizační terapie * metody škodlivé účinky MeSH
- srdeční selhání * chirurgie terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
AIMS: The standard deviation of activation time (SDAT) derived from body surface maps (BSMs) has been proposed as an optimal measure of electrical dyssynchrony in patients with cardiac resynchronization therapy (CRT). The goal of this study was two-fold: (i) to compare the values of SDAT in individual CRT patients with reconstructed myocardial metrics of depolarization heterogeneity using an inverse solution algorithm and (ii) to compare SDAT calculated from 96-lead BSM with a clinically easily applicable 12-lead electrocardiogram (ECG). METHODS AND RESULTS: Cardiac resynchronization therapy patients with sinus rhythm and left bundle branch block at baseline (n = 19, 58% males, age 60 ± 11 years, New York Heart Association Classes II and III, QRS 167 ± 16) were studied using a 96-lead BSM. The activation time (AT) was automatically detected for each ECG lead, and SDAT was calculated using either 96 leads or standard 12 leads. Standard deviation of activation time was assessed in sinus rhythm and during six different pacing modes, including atrial pacing, sequential left or right ventricular, and biventricular pacing. Changes in SDAT calculated both from BSM and from 12-lead ECG corresponded to changes in reconstructed myocardial ATs. A high degree of reliability was found between SDAT values obtained from 12-lead ECG and BSM for different pacing modes, and the intraclass correlation coefficient varied between 0.78 and 0.96 (P < 0.001). CONCLUSION: Standard deviation of activation time measurement from BSM correlated with reconstructed myocardial ATs, supporting its utility in the assessment of electrical dyssynchrony in CRT. Importantly, 12-lead ECG provided similar information as BSM. Further prospective studies are necessary to verify the clinical utility of SDAT from 12-lead ECG in larger patient cohorts, including those with ischaemic cardiomyopathy.
- MeSH
- elektrokardiografie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- prostředky srdeční resynchronizační terapie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- srdeční arytmie terapie MeSH
- srdeční resynchronizační terapie * metody MeSH
- srdeční selhání * diagnóza terapie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.
- MeSH
- blokáda Tawarova raménka MeSH
- echokardiografie MeSH
- elektrokardiografie metody MeSH
- funkce levé komory srdeční fyziologie MeSH
- jizva MeSH
- lidé MeSH
- srdeční resynchronizační terapie * škodlivé účinky metody MeSH
- srdeční selhání * diagnóza terapie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Left bundle branch area pacing (LBBAP) is an emerging technique to achieve cardiac resynchronization therapy (CRT), but its feasibility and safety in elderly patients with heart failure with reduced ejection fraction and left bundle branch block is hardly investigated. METHODS: We enrolled consecutive patients with an indication for CRT comparing pacing parameters and complication rates of LBBAP-CRT in elderly patients (≥ 75 years) versus younger patients (< 75 years) over a 6-month follow-up. RESULTS: LBBAP was successful in 55/60 enrolled patients (92%), among which 25(45%) were elderly. In both groups, LBBAP significantly reduced the QRS duration (elderly group: 168 ± 15 ms to 136 ± 12 ms, p < 0.0001; younger group: 166 ± 14 ms to 134 ± 11 ms, p < 0.0001) and improved LVEF (elderly group: 28 ± 5% to 40 ± 7%, p < 0.0001; younger group: 29 ± 5% to 41 ± 8%, p < 0.0001). The pacing threshold was 0.9 ± 0.8 V in the elderly group vs. 0.7 ± 0.5 V in the younger group (p = 0.350). The R wave was 9.5 ± 3.9 mV in elderly patients vs. 10.7 ± 2.7 mV in younger patients (p = 0.341). The fluoroscopic (elderly: 13 ± 7 min vs. younger: 11 ± 7 min, p = 0.153) and procedural time (elderly: 80 ± 20 min vs. younger: 78 ± 16 min, p = 0.749) were comparable between groups. Lead dislodgement occurred in 2(4%) patients, 1 in each group (p = 1.000). Intraprocedural septal perforation occurred in three patients (5%), 2(8%) in the elderly group (p = 0.585). One patient (2%) in the elderly group had a pocket infection. CONCLUSIONS: LBBAP is a feasible and safe technique for delivering physiological pacing in elderly patients who are candidates for CRT with suitable pacing parameters and low complication rates.
- MeSH
- elektrokardiografie metody MeSH
- Hisův svazek MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- lidé MeSH
- senioři MeSH
- srdeční resynchronizační terapie * metody MeSH
- studie proveditelnosti MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Device-based algorithms offer the potential for automated optimization of cardiac resynchronization therapy (CRT), but the process for accepting them into clinical use is currently still ad-hoc, rather than based on pre-clinical and clinical testing of specific features of validity. We investigated how the QuickOpt-guided VV delay (VVD) programming performs against the clinical and engineering heuristic of QRS complex shortening by CRT. METHODS: A prospective, 2-center study enrolled 37 consecutive patients with CRT. QRS complex duration (QRSd) was assessed during intrinsic atrioventricular conduction, synchronous biventricular pacing, and biventricular pacing with QuickOpt-proposed VVD. The measurements were done manually by electronic calipers in signal-averaged and magnified 12-lead QRS complexes. RESULTS: Native QRSd was 174 ± 22 ms. Biventricular pacing with empiric AVD and synchronous VVD resulted in QRSd 156 ± 20 ms, a significant narrowing from the baseline QRSd by 17 ± 27 ms, P = 0.0003. In 36 of 37 patients, the QuickOpt algorithm recommended left ventricular preexcitation with VVD of 42 ± 18 ms (median 40 ms; interquartile range 30-55 ms, P <0.00001). QRSd in biventricular pacing with QuickOpt-based VVD was significantly longer compared with synchronous biventricular pacing (168 ± 25 ms vs. 156 ± 20 ms; difference 12 ± 11ms; P <0.00001). This prolongation correlated with the absolute VVD value (R = 0.66, P <0.00001). CONCLUSIONS: QuickOpt algorithm systematically favours a left-preexcitation VVD which translates into a significant prolongation of the QRSd compared to synchronous biventricular pacing. There is no reason to believe that a manipulation that systematically widens QRSd should be considered to optimize physiology. Device-based CRT optimization algorithms should undergo systematic mechanistic pre-clinical evaluation in various scenarios before they are tested in large clinical studies.