3D ED Dotaz Zobrazit nápovědu
Článok prináša pohľad do oblasti skenovania tváre v ortodoncii ako aj fúzie takéhoto 3D záznamu s celohlavovým CBCT iCAT™ skenom. Autor popisuje vlastné skúsenosti s 3D tlačou takéhoto kombinovaného modelu a orientačne posudzuje presnosi reprodukcie medzi reálnym modelom, virtuálnym 3D modelom a vytlačeným modelom. Vysvetľuje tiež princípy a rozdiely medzi aktívnou a pasívnou stereofotogrametriou a tiež porovnáva skúsenosti medzi jednotlivými stereoskopickými kamerami: 3DMD TM, 3D-Shape™ a D/3D™. Článok tiež venuje pozornosí perspektívam klinického využitia uvedených technologických postupov.
The article reviews the face-scanning procedures and technologies in orthodontics, as well as the fusion of such face-scans with CBCT iCAT TM scans. The author gives his own experience with 3D print of the fused face-CBCT model, and evaluates in brief the accuracy of a reproduction in vivo, a virtual 3D model, and a printed 3D model. The basic principles and differences between active and passive stereophotogrammetry are explained, and the experience with different stereoscopic cameras 3DMD TM, 3D-Shape TM, and Dl3D TM is discussed. The article also gives the current view on perspectives and the use of the technologies described in clinical orthodontics.
3D modely umožnily obrovský pokrok v rekonstrukční chirurgii. Byl proveden průzkum literatury s cílem zjistit současnou použitelnost 3D modelování kombinovaného s volnými laloky, které volné laloky se v těchto případech nejčastěji používají a bylo-li již popsáno použití 3D modelování u prelaminovaných volných laloků. Byli také vybráni dva pacienti s výrazným defektem obličeje, kteří podstoupili operační výkony zahrnující 3D modelování a prelaminační techniky. 3D modelování se nejčastěji používá při korekci mandibulárních defektů volnými fibulárními laloky. Žádný literární odkaz nevzpomíná kombinované použití 3D modelování a prelaminace, ale zde bylo demonstrováno použití těchto dvou technik společně. Byly získány dva custome-made a trojrozměrné prelaminované volné laloky, díky kterým dva vybraní pacienti dosáhli významného estetického a morfologického zlepšení. Nejsou-li k dispozici žádné místní štěpy nebo laloky a je zamýšlena trojrozměrná rekonstrukce obličeje, je třeba zvážit využití prelaminační techniky. Složitost rekonstrukce může být usnadněna použitím 3D modelů, které umožňují získat personalizovaný lalok při zkrácení operačního času. Prelaminace dohromady s 3D modelováním může být výkonným nástrojem pro korekci složitých deformit obličeje.
3D models allowed a huge advance of reconstructive surgery. A literature review was performed in order to ascertain the current applicability of 3D modeling combined with free flaps, the most commonly used free flaps, and whether the use of 3D models alongside prelaminated free flaps has already been described. Also, two patients with significant facial disfiguration scheduled for surgeries that included 3D modeling and prelamination techniques were selected. 3D modeling is mostly used for the correction of mandibular defects with fibular free flaps. No literature reports the combined use of 3D models and prelamination, but we have demonstrated its applicability: two costume-made prelaminated free flaps were obtained and the patients achieved an important aesthetic and morphological improvement. When no local grafts or flaps are available, and a three-dimensional facial reconstruction is intended, prelamination is a complex option to be considered. This complexity can be reduced by the use of 3D models, being a personalized flap obtained in a decreased operating time. Prelamination used alongside 3D modeling can be a powerful tool in the correction of complex facial deformities.
- MeSH
- dospělí MeSH
- lidé MeSH
- obličej chirurgie MeSH
- poranění obličeje chirurgie MeSH
- výsledek terapie MeSH
- zákroky plastické chirurgie * metody MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
- přehledy MeSH
Úvod: Vaskularizovaný transfer lymfatických uzlin (vascularized lymph node transfer – VLNT) představuje již relativně zavedenou mikrochirurgickou techniku v léčbě lymfedému. Její užití je vhodné zejména u pokročilých stádií lymfedému, kdy již není lymfovenózní anastomóza (LVA) indikována pro pokročilou sklerotizaci lymfatických cév. Pokud je transfer uzlin prováděn izolovaně bez kožního ostrovu, jsou možnosti pooperačního monitoringu omezené. Cílem studie bylo vyhodnocení užití vysokofrekvenčního ultrazvuku s barevným dopplerem k monitoringu stopkovaných lymfatických laloků. Metody: Celkem 15 laloků bylo elevováno na stopce a. et v. thoracica lateralis u potkanů kmene Wistar. Axilární svazek byl šetřen pro zachování mobility a komfortu zvířat. Vzorek byl rovnoměrně rozdělen do 3 následujících skupin: skupina A, arteriální ischemie; skupina B, žilní okluze; skupina C, zdravá skupina. Výsledky: Ultrazvukové snímky a trojrozměrné rekonstrukce z dopplerovského ultrazvuku poskytly potřebné informace o morfologii laloků a o případných patologických změnách. Překvapivě jsme nalezli žilní průtok u skupiny A. Toto zjištění podporuje teorii pumpy a koncept venózního VLNT. Závěr: Použití trojrozměrného barevného ultrazvukového doppleru je efektivní metodou pro monitoring lymfatických laloků bez kožního ostrovu. Trojrozměrná rekonstrukce usnadňuje vizualizaci morfologie laloku a případnou detekci patologie. Tuto metodu není těžké si osvojit. Námi použité vybavení bylo uživatelsky přívětivé i v nezkušených rukách rezidenta a nálezy je možné kdykoli analyzovat zpětně, je-li to třeba. Použití trojrozměrné rekonstrukce stírá problémy spojené se subjektivním hodnocením v monitoringu VLNT.
Background: Vascularized lymph node transfer (VLNT) is a relatively well-established microsurgical treatment for lymphedema that is especially beneficial for advanced cases in which lymphovenous anastomosis is not indicated due to lymphatic vessel sclerosis. When VLNT is performed without a skin paddle, such as a buried flap, the possibilities for postoperative monitoring are limited. The aim of our study was to evaluate the use of ultra-high-frequency color Doppler ultrasound with 3D reconstruction in a pedicled axillary lymph node flap. Methods: Flaps were elevated in 15 Wistar rats based on the lateral thoracic vessels. We preserved the axillary vessels to maintain the rats’ mobility and comfort. The rats were divided into three groups as follows: Group A, arterial ischemia; group B, venous occlusion; and group C, healthy. Results: Ultrasound and color Doppler scan images revealed clear information on flap morphology changes and pathology if it was present. Surprisingly, we detected venous flow in group A rats, supporting the pump theory and venous lymph node flap concept. Conclusion: We conclude that 3D color Doppler ultrasound is an effective method for monitoring buried lymph node flaps. 3D reconstruction makes it easier to visualize the flap anatomy and detect pathology if it is present. Moreover, the learning curve for the technique is short. Our setup is user-friendly even in the inexperienced hands of a surgical resident, and images can be reevaluated at any time if necessary. The use of 3D reconstruction removes the complications associated with observer-dependent monitoring of VLNT.
- MeSH
- chirurgické laloky transplantace MeSH
- lymfatické cévy chirurgie diagnostické zobrazování MeSH
- lymfatické uzliny * diagnostické zobrazování transplantace MeSH
- lymfedém terapie MeSH
- mikrochirurgie metody MeSH
- modely u zvířat MeSH
- potkani Wistar MeSH
- ultrasonografie dopplerovská barevná * metody MeSH
- výzkum MeSH
- zobrazování trojrozměrné MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- práce podpořená grantem MeSH
[1st ed.]
- MeSH
- lidé MeSH
- nádory obličeje chirurgie MeSH
- obličej * chirurgie MeSH
- zákroky plastické chirurgie MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- abstrakt z konference MeSH
Studies in health technology and informatics ; Vol. 19
216 s.
1st ed. 116 s. : il.
- MeSH
- echokardiografie transezofageální MeSH
- perioperační období MeSH
- Publikační typ
- monografie MeSH
1st ed. ix, 350 s. + 1 elektronický optický disk (CD-ROM) a 1 pár 3-D skel
- MeSH
- neuroanatomie MeSH
- Publikační typ
- atlasy MeSH
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- neurologie
- anatomie
Within the framework of a research project concerning hard palate morphometry in facial clefts, optical non-contact 3D profilometry based on the Fourier transform method was applied. The article discusses the principle of Fourier transform profilometry, the procedure for image acquisition and processing, as well as the merits of this method in the study of palate morphology.
Cílem této studie bylo porovnat rozdíl v postavení pánve vzniklý vlivem svalových dysbalancí u skupiny dětí ve věku 11-13 let ze sportovních klubů se zaměřením na karate, s kontrolní skupinou dětí stejného věku. V rámci studie proběhlo měření somatometrických charakteristik a tělesného složení (% BF) dětí středního školního věku, vyšetření technikami manuální medicíny pro zjištění postavení pánve a bederní lordózy (Lewit, 2003). Hlavní použitou metodou byla 3D analýza pohybu pro zjištění rozsahu pohybu pánve z maximální retroverze do maximální anteverze. Byl hodnocen pohyb pánve v prostoru (pohyb segmentu pánve vůči souřadnicovému systému laboratoře - LSS) a pohyb bederní páteře vůči pánvi (neboli pohyb segmentu bederní páteře vůči segmentu pánve). Výsledky z 3 D analýzy pohybu ukázaly, že velikost rozsahu pohybu (ať byla porovnávána mediány či průměry) se při porovnání karatistů a ne-karatistů významně nelišila. Významné rozdíly byly zjištěny pouze v hodnotách výběrových směrodatných odchylek pohybu (p=0,03). Lze tedy konstatovat, že i přes malé počty probandů se podařilo prokázat rozdíl mezi karatisty a ne-karatisty alespoň ve variabilitě rozsahů pohybu.
The aim of this study was to compare the difference in the position of the pelvis due to muscle imbalances resulting in a group of children aged 11-13 years from sports clubs to focus on karate, with a control group of children of the same age. The study concentrated on somatometric measurement characteristics and body composition (% BF) of children in middle school age, examination manual medicine techniques to determine the position of the pelvis and lumbar lordosis (Lewit, 2003). The main method used was a 3D motion analysis to determine the range of motion of the pelvis from the maximum to the maximum retroversion anteversion. There were evaluated pelvic movement in space (motion of pelvis segment against laboratory coordinate system - LCS) and lumbar spine movement towards pelvis (or motion of lumbar spine segment to pelvis segment). Results from 3-D motion analysis showed, that the range of movement (either compared the medians or averages), if compared karate with non-karate practising pupils, was not significantly different. Significant differences were found only in the values of sample standard deviations of motion (p=0.03). It can be said that despite the small numbers of subjects the data are able to demonstrate the difference between karate practising and karate nonpractising pupils at least in the variability of ranges of movement.
- Klíčová slova
- svalová nerovnováha, 3D analýza pohybu, manuální medicína, pohyb pánve, karate,
- MeSH
- bojové sporty * fyziologie statistika a číselné údaje MeSH
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- pánev * fyziologie MeSH
- pohybová aktivita * MeSH
- svaly MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH